Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

A measurement of the vibrational band strength for the upsilon sub 3 band of the HO2 radical

The HO2 radicals generated in a discharge-flow system were observed with tunable diode laser absorption in the P-branch of the nu(3) vibrationall band at 1080/cm. The observed line positions agree with those calculated from the molecular constants for the nu(3) bland obtained from a previous study using laser magnetic resonance spectroscopy. The band strength was determined by observing line center absoptions when HO2 is produced in the reaction F + H2O2 yields HO2 + HF (k1) with a measured concentration of atomic fluorine and excess hydrogen peroxide. F-atom concentrations are measured by diode laser absorption of the spin-orbit transition at 404/cm. The analysis accounts for HO2 losses due to the reactions of HO2 + HO2 yields H2O2 + O2 (k3) and F + HO2 yields HF + O2 (k4). The line strength for the 6(15) 7(16) F(1) transition is 2.9 x 10 to the 21st power sq cm/molecule/cm which corresponds to a nu(3) band strength of 34 +/- 9 sq/cm(STP atm). This value is a factor of 6 lower than previous ab initio calculations. These results will be useful in assessing the feasibility of atmospheric measurements of HO2 using infrared absorption techniques.

Zahniser, M. S.↗

Characterization of Synthetic and Natural Manganese Oxides as Martian Analogues

Recent discoveries of highly concentrated manganese oxides in Gale Crater and on the rim of Endeavour Crater by the Mars Science Laboratory Curiosity and Mars Exploration Rover Opportunity, respectively, imply more highly oxidizing aqueous conditions than previously recognized. Manganese oxides are a significant environmental indicator about ancient aqueous conditions, provided the phases can be characterized reliably. Manganese oxides are typically fine-grained and poorly crystalline, making the mineral structures difficult to determine, and they generally have very low visible reflectance with few distinctive spectral features in the visible to near infrared, making them a challenge for interpretation from remote sensing data. Therefore, these recent discoveries motivate better characterization using methods available on Mars, particularly visible to near infrared (VNIR) spectroscopy, X-ray diffractometry (XRD), and compositional measurements. Both rovers have complementary instruments in this regard. Opportunity is equipped with its multispectral visible imager, Pancam, and an Alpha Particle X-ray Spectrometer (APXS), and Curiosity has the multispectral Mastcam, ChemCam (laser-induced breakdown spectroscopy and passive spectroscopy), and APXS for in situ characterization, and ChemMin (XRD) for collected samples.

Fox, V. K.↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Applied Spectra, Inc.

Groundwater resources can be contaminated by a variety of surface and subsurface sources. For instance, metals can be leached from surface dumps (e.g. landfills, etc.) and reach groundwater supplies by percolation though the soil. Additionally, subsurface activities such as geologic carbon storage (GCS) could result in contamination. In the event of CO2 leakage, freshwater above the injection site can potentially be contaminated with metals either originating from the formation fluids or leached from formation rocks by CO2 acidification. Detection of these contaminating metals is critical for maintaining water safety and providing an early warning of a containment breach. Therefore, a compact, subsurface capable laser induced breakdown spectroscopy (LIBS) based sensor has been developed for groundwater quality monitoring applications. LIBS sensor technology has been advanced from benchtop feasibility studies to a custom fabricated, watertight prototype. The all optical sensor head is built using a low cost passively Q-switched (PQSW) laser, which is fiber coupled to a control unit containing the pump laser and a gated spectrometer. Separating the LIBS excitation laser from the pump and spectrometer allows the expensive and fragile components to remain in a safe, central location while only the sensor head needs to enter the subsurface. Testing of the prototype sensors show Limits of Detection (LODs) comparable to benchtop, actively Q-switched systems and has verified that the fiber coupling and triggering schemes perform as desired.

McIntyre, Dustin↗

Tree-ring growth and wood chemistry response to manipulated precipitation variation for two temperate Quercus species

We examined the relationship among ambient and manipulated precipitation, wood chemistry, and their relationship with radial growth for two oak species in eastern Tennessee. The study took place on the Walker Branch Throughfall Displacement Experiment (TDE) site, located at the Oak Ridge National Laboratory in Oak Ridge, TN. Two dominant species, white oak (Quercus alba) and chestnut oak (Quercus prinus), were selected for study from a 13-year experiment of whole-stand precipitation manipulation (wet, ambient and dry). The relationships between tree-ring width and climate were compared for both species to determine the impact of precipitation manipulations on ring width index. This study used experimental spectroscopy techniques to measure the sensitivity of tree-ring responses to directional changes in precipitation over 13 years, and the results suggest that oaks at this study site are resilient to imposed changes, but sensitive to inter-annual variations in climate. Laser-induced breakdown spectroscopy (LIBS) allowed us to measure nutrient intensities (similar to element concentrations) at 0.5-1.0 mm spacing along the radial growth axis of trees growing in the wet, ambient, and dry treatment sites. A difference in stemwood nutrient levels was observed between the two oak species and among the three treatments. Significant variation in element intensity was observed across treatments for some elements (Ca, K, Mg, Na, N and P) suggesting the potential for long-term impacts on growth under a changing climate regimes for southeastern oaks.

09 BIOMASS FUELS↗

A Study of Eu and Yb in aqueous solution by underwater laser-induced breakdown spectroscope

We present the use of under water laser induced breakdown spectroscopy (LIBS) to detect two rare earth elements; Eu and Yb dissolved in bulk aqueous solutions at ambient and high-pressure conditions. Strong emission lines of Eu and Yb were identified in the underwater LIBS spectra. Temporal evolution of plasma, the effect of laser pulse energy, and the effect of pressure on the spectral emission were studied. Calibration curves were developed to demonstrate the possibility of using LIBS technique for their quantification and limits of detection were estimated.

Bhatt, Chet R.↗

Analytical characterization of laser induced plasmas towards uranium isotopic analysis in gaseous uranium hexafluoride

To perform direct enrichment assay on gaseous uranium hexafluoride (UF 6 ) with laser induced breakdown spectroscopy (LIBS), the dominant spectral-line features, evolution of the signal and background of the U II 424.437 nm line, and its Stark width and shift, were studied as a function of UF 6 gas pressure and pulse energy of a nanosecond Nd:YAG laser. In this work, vapor pressure of UF 6 was found to be the most important parameter for LIBS analysis of gaseous UF 6 . Spectral congestion with numerous U lines of high excitation potential was observed and signal-to-background ratio (SBR) was low for measurements with 80 Torr UF 6 . Only when both UF 6 vapor pressure and laser pulse energy were low, for example, less than 20 Torr pressure and 30 mJ pulse energy, the resultant LIBS spectra from gaseous UF 6 resembled those obtained from solid U samples. The experimental data also suggest that U and F atoms recombine back to UF 6 after the laser pulse. The U emission was found to decay fast with a persistent background signal, degrading SBR with delay time. Systematic positive biases were found for UF 6 enrichment assays performed with the 235 U– 238 U line pair at 424.412–424.437 nm, which was confirmed to be caused by self-absorption. Even with optimization of experimental parameters and incorporation of a self-absorption term into the spectral-fitting algorithm, to reduce and compensate for self-absorption, self-absorption is still a main factor limiting accurate UF 6 enrichment assay. The use of another spectral window which contains no resonance lines is a prospective solution for the self-absorption issue.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Photovoltaic detector based on type II heterostructure with deep AlSb/InAsSb/AlSb quantum well in the active region for the midinfrared spectral range

Photodetectors for the spectral range 2-4 {mu}m, based on an asymmetric type-II heterostructure p-InAs/AlSb/InAsSb/AlSb/(p, n)GaSb with a single deep quantum well (QW) or three deep QWs at the heterointerface, have been grown by metal-organic vapor phase epitaxy and analyzed. The transport, luminescent, photoelectric, current-voltage, and capacitance-voltage characteristics of these structures have been examined. A high-intensity positive and negative luminescence was observed in the spectral range 3-4 {mu}m at high temperatures (300-400 K). The photosensitivity spectra were in the range 1.2-3.6 {mu}m (T = 77 K). Large values of the quantum yield ({eta} = 0.6-0.7), responsivity (S{sub {lambda}} = 0.9-1.4 A W{sup -1}), and detectivity (D*{sub {lambda}} = 3.5 Multiplication-Sign 10{sup 11} to 10{sup 10} cm Hz{sup 1/2} W{sup -1}) were obtained at T = 77-200 K. The small capacitance of the structures (C = 7.5 pF at V = -1 V and T = 300 K) enabled an estimate of the response time of the photodetector at {tau} = 75 ps, which corresponds to a bandwidth of about 6 GHz. Photodetectors of this kind are promising for heterodyne detection of the emission of quantum-cascade lasers and IR spectroscopy.

36 MATERIALS SCIENCE↗

Optimization of Picosecond Laser Parameters for Surface Treatment of Composites Using a Design of Experiments (DOE) Approach

Based on guidelines from the Federal Aviation Administration, research supported by the NASA Advanced Composites Project is investigating methods to improve process control for surface preparation and pre-bond surface characterization on aerospace composite structures. The overall goal is to identify high fidelity, rapid, and reproducible surface treatments and surface characterization methods to reduce the uncertainty associated with the bonding process. The desired outcome is a more reliable bonded airframe structure, and to reduce time to achieve certification. In this work, a design of experiments (DoE) approach was conducted to determine optimum laser ablation conditions using a pulsed laser source with a nominal pulse width of 10 picoseconds. The laser power, frequency, scan speed, and number of passes (1 or 2) were varied within the laser system operating boundaries. Aerospace structural carbon fiber reinforced composites (Torayca® 3900-2/T800H) were laser treated, then characterized for contamination, and finally bonded for mechanical testing. Pre-bond characterization included water contact angle (WCA) using a handheld device, ablation depth measurement using scanning electron microscopy (SEM), and silicone contamination measurement using laser induced breakdown spectroscopy (LIBS). In order to accommodate the large number of specimens in the DoE, a rapid-screening, double cantilever beam (DCB) test specimen configuration was devised based on modifications to ASTM D5528. Specimens were tested to assess the failure modes observed under the various laser surface treatment parameters. The models obtained from this DoE indicated that results were most sensitive to variation in the average laser power. Excellent bond performance was observed with nearly 100% cohesive failure for a wide range of laser parameters. Below about 200 mW, adhesive failure was observed because contamination was left on the surface. For laser powers greater than about 600 mW, large amounts of fiber were exposed, and the failure mode was predominately fiber tear.

Palmieri, Frank L.↗

Dating Igneous Rocks Using the Potassium–Argon Laser Experiment (KArLE) Instrument: A Case Study for ~380 Ma Basaltic Rocks

We report new K–Ar isochron data for two ~380 Ma basaltic rocks, using an updated version of the Potassium–Argon Laser Experiment (KArLE), which is being developed for future in situ dating of planetary materials. These basalts have K contents comparable with those of lunar KREEP basalts or igneous lithologies found by Mars rovers, whereas previous proof‐of‐concept studies focused primarily on more K‐rich rocks. We aim to measure these analogous samples to show the advancing capability of in situ K–Ar geochronology. Combining laser‐induced breakdown spectroscopy (LIBS), mass spectrometry (MS), and microscopic analyses, we measured the abundance of K and 40Ar from 23 spots on the basalt samples. We then constructed K–Ar isochron plots from these rocks. The breadboard instrument consists of flight‐equivalent devices including a 30‐mJ Nd:YAG laser and a quadrupole mass spectrometer. Despite much lower K abundances than in previous studies, the isochron slopes yielded 380 ± 44 Ma and 398 ± 50 Ma for 380.7‐Ma and 373.5‐Ma rocks, respectively, indicating that accuracy better than 25 Ma (<7%) is achievable with our instrument. The isochron intercepts both yielded trapped 40Ar approximately 1 × 10−6 cm3 STP/g. Our experimental results demonstrate that accurate and precise measurements are possible using the KArLE approach on basaltic rocks, which are ubiquitous on planetary surfaces, and are useful in addressing a wide range of questions in planetary science.

Yuichiro Cho↗

Isotope shifts and hyperfine structure of the Fe I 372-nm resonance line

We report measurements of the isotope shifts of the 3d{sup 6}4s{sup 2} a {sup 5}D{sub 4}-3d{sup 6}4s4p z {sup 5}F{sub 5}{sup o} Fe I resonance line at 372 nm between all four stable isotopes {sup 54}Fe, {sup 56}Fe, {sup 57}Fe, and {sup 58}Fe, as well as the complete hyperfine structure of that line for {sup 57}Fe, the only stable isotope having a nonzero nuclear spin. The field and specific mass shift coefficients of the transition have been derived from the data, as well as the experimental value for the hyperfine structure magnetic dipole coupling constant A of the excited state of the transition in {sup 57}Fe: A(3d{sup 6}4s4p z {sup 5}F{sub 5}{sup o})=81.69(86) MHz. The measurements were carried out by means of high-resolution Doppler-free laser saturated absorption spectroscopy in a Fe-Ar hollow cathode discharge cell using both natural and enriched iron samples. The measured isotope shifts and hyperfine constants are reported with uncertainties at the percent level.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimization of La{sub 0.7}Ba{sub 0.3}MnO{sub 3-{delta}} complex oxide laser ablation conditions by plume imaging and optical emission spectroscopy

The properties of thin films of complex oxides, such as La{sub 1-x}D{sub x}MnO{sub 3-{delta}} (D=Ba, Ca, Sr, etc.), produced by pulsed laser deposition depend critically on the experimental parameters in which laser ablation is carried out. Here, we report a comparative analysis of the pulsed laser ablation process of La{sub 0.7}Ba{sub 0.3}MnO{sub 3-{delta}}, in oxygen background, in the ambient pressure range from 10{sup -2} to 1 mbar, typically employed in pulsed laser deposition of manganites. The laser ablation plume was studied by using time-gated imaging and optical emission spectroscopy techniques. It was found that at a pressure of {approx_equal}10{sup -2} mbar, the plume species arriving at the substrate are characterized by hyperthermal kinetic energy ({approx_equal}10 eV), and high degree of excitation. On the contrary, at larger oxygen pressure (0.1-1 mbar), the velocity of plume species reaching the substrate, and their degree of excitation are much reduced by the confining effects of the background gas. These features explain why an appropriate choice of the experimental conditions in which the deposition process is carried out leads to better quality films, providing helpful indications to improve control over the growth process of both La{sub 1-x}D{sub x}MnO{sub 3-{delta}} and other perovskitic oxides.

36 MATERIALS SCIENCE↗

Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

environmental monitoring↗

Streaked x-ray spectrometer having a discrete selection of Bragg geometries for Omega

The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO/QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler-Free Saturation Spectroscopy (DFSS) for Magnetic and Electric Field Measurements in an FRC plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on a feasibility study of Doppler-free saturation spectroscopy (DFSS) as a diagnostic strategy to measure the internal magnetic and electric fields of TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic and electric fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening linewidths and reveal Zeeman/Stark split hyperfine structures of target emission lines. The collaboration involved the use of ORNL’s suite of experimentally validated quantum mechanical modelling codes to simulate theoretical atomic spectra for a variety of machine parameters and laser beam configurations. TAE’s expertise was heavily used to provide measurements/models of the required machine parameters needed as inputs to the simulations. Results of an all-encompassing error analysis demonstrate the favourable capabilities of the diagnostic and provided invaluable insights as to how DFSS can be best used to accurately measure internal B/E-fields in C-2W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphoton Double Ionization of Ar in Intense Extreme Ultraviolet Laser Fields Studied by Shot-by-Shot Photoelectron Spectroscopy

Photoelectron spectroscopy has been performed to study the multiphoton double ionization of Ar in an intense extreme ultraviolet laser field (h{nu}{approx}21 eV, {approx}5 TW/cm{sup 2}), by using a free electron laser (FEL). Three distinct peaks identified in the observed photoelectron spectra clearly show that the double ionization proceeds sequentially via the formation of Ar{sup +}: Ar+h{nu}{yields}Ar{sup +}+e{sup -} and Ar{sup +}+2h{nu}{yields}Ar{sup 2+}+e{sup -}. Shot-by-shot recording of the photoelectron spectra allows simultaneous monitoring of FEL spectrum and the multiphoton process for each FEL pulse, revealing that the two-photon ionization from Ar{sup +} is significantly enhanced by intermediate resonances in Ar{sup +}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental station for laser-based picosecond time-resolved x-ray absorption near-edge spectroscopy

We present an experimental station designed for time-resolved X-ray Absorption Near-Edge Spectroscopy (XANES). It is based on ultrashort laser-plasma x-ray pulses generated from a table-top 100 mJ-class laser at 10 Hz repetition rate. A high transmission (10%–20%) x-ray beam line transport using polycapillary optics allows us to set the sample in an independent vacuum chamber, providing high flexibility over a wide spectral range from 0.5 up to 4 keV. Some XANES spectra are presented, demonstrating 1% noise level in only ∼1 mn and ∼100 cumulated laser shots. Time-resolved measurements are reported, indicating that the time resolution of the entire experimental station is 3.3 ± 0.6 ps rms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Variable and Multivariate Analysis of Remote Laser-Induced Breakdown Spectra for Prediction of Rb, Sr, Cr, Ba, and V in Igneous Rocks

Laser-induced breakdown spectroscopy (LIBS) will be employed by the ChemCam instrument on the Mars Science Laboratory rover Curiosity to obtain UV, VIS, and VNIR atomic emission spectra of surface rocks and soils. LIBS quantitative analysis is complicated by chemical matrix effects related to abundances of neutral and ionized species in the resultant plasma, collisional interactions within plasma, laser-to-sample coupling efficiency, and self-absorption. Atmospheric composition and pressure also influence the intensity of LIBS plasma. These chemical matrix effects influence the ratio of intensity or area of a given emission line to the abundance of the element producing that line. To compensate for these complications, multivariate techniques, specifically partial least-squares regression (PLS), have been utilized to predict major element compositions (>1 wt.% oxide) of rocks, PLS methods regress one or multiple response variables (elemental concentrations) against multiple explanatory variables (intensity at each pixel of the spectrometers). Because PLS utilizes all available explanatory variable and eliminates multicollinearity, it generally performs better than univariate methods for prediction of major elements. However, peaks arising from emissions from trace elements may be masked by peaks of higher intensities from major elements. Thus in PLS regression, wherein a correlation coefficient is determined for each elemental concentration at each spectrometer pixel, trace elements may show high correlation with more intense lines resulting from optical emissions of other elements. This could result in error in predictions of trace element concentrations. Here, results of simple linear regression (SLR) and multivariate PLS-2 regression for determination of trace Rb, Sr, Cr, Ba, and V in igneous rock samples are compared. This study focuses on comparisons using only line intensities rather than peak areas to highlight differences between SLR and PLS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ATOMIC Simulations and Experimental Data for CaCO3 Mixtures

This data consists of simulations and experimental measurements of laser-induced breakdown spectroscopy (LIBS). The simulations are produced by ATOMIC, a general purpose plasma modeling and kinetics code that has been designed to compute emission (or absorption) spectra from plasmas [1] and are used to develop a statistical characterization of matrix effects. Our overall suite of simulations includes contains several sets of simulations: training and validation sets of simulations for three and four element mixtures of calcium, carbon, oxygen, and nitrogen (included to account for atmosphere) along with simulations of the individual elements. The 4-element simulations include the mixture of all four elements mentioned and for each of the four individual elements. The 3-element simulations include output for the mixture of calcium, carbon, oxygen and for these three individual elements. The training data were produced using a 600-run design, shown in Figure 1, that varies input parameters temperature (T), electron density (Ne), and proportion of the elements calcium, carbon, oxygen, and nitrogen (Ca; C; O; N) for the 4 element output. The 3-element output includes all parameters except for the proportion of nitrogen. The element proportions (all the variables but T and Ne) sum to one and are unused in the single-element simulations. The validation data was produced with a 80-run design shown in Figure 2. The training and validation simulation outputs for the 4-element simulations for the mixture and for the single element calcium are shown as sample simulations in Figures 3 and 4 respectively. The simulations produce spectra over a range of 190nm - 950nm that roughly mimics the range collected by the SciAps Z-300 LIBS instrument that was used for the experimental data. The measured spectra for a CaCO3 (which may include contribution from Earth's atmosphere) in the experiment is shown in in Figure 5. All files are kept in directories whose names indicate the elemental composition (CaCO3, Ca, C, O, or N), number of elements (3 or 4), and purpose (training, which is not labeled in the file name, or validation) with file names numbered to indicate the line in the design files used to produce the simulation. The designs are provided as text files with names indicating their purpose. The experimental data is provided as a CSV file. [1] J Colgan, EJ Judge, DP Kilcrease, and JE Barefield II. Ab-initio modeling of an iron laser-induced plasma: Comparison between theoretical and experimental atomic emission spectra. Spectrochimica Acta Part B: Atomic Spectroscopy, 97:65{73}, 2014.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗