Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laboratory analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Analytical control test plan and microbiological methods for the water recovery test

Qualitative and quantitative laboratory results are important to the decision-making process. In some cases, they may represent the only basis for deciding between two or more given options or processes. Therefore, it is essential that handling of laboratory samples and analytical operations employed are performed at a deliberate level of conscientious effort. Reporting erroneous results can lead to faulty interpretations and result in misinformed decisions. This document provides analytical control specifications which will govern future test procedures related to all Water Recovery Test (WRT) Phase 3 activities to be conducted at the National Aeronautics and Space Administration/Marshall Space Flight Center (NASA/MSFC). This document addresses the process which will be used to verify analytical data generated throughout the test period, and to identify responsibilities of key personnel and participating laboratories, the chains of communication to be followed, and ensure that approved methodology and procedures are used during WRT activities. This document does not outline specifics, but provides a minimum guideline by which sampling protocols, analysis methodologies, test site operations, and laboratory operations should be developed.

Traweek, M. S.↗

Developing a GUM Compliant Uncertainty Approach for NDA Gamma Analysis Using FRAM

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory (LANL) to analyze gamma-ray spectra for the isotopic composition of plutonium or uranium. This software provides means to easily process gamma-ray spectra to obtain isotopic information and is used globally for international safeguards applications. In a recent review of the FRAM code for the use in nuclear forensics applications, it was determined that a more complete understanding and definition of the various sources of uncertainty that contribute to the overall uncertainty of the FRAM measurement process is required. As one of the ISO 17025 accredited Bulk Special Nuclear Materials Analysis Program (BSAP) laboratories, LANL is required to perform an accurate and transparent uncertainty calculation on every analysis it performs. This paper describes a new approach to calculate a Guide to the Expression of Uncertainty in Measurement (GUM) compliant FRAM uncertainty to support nuclear forensics applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

AUTOMATED RADIOANALYTICAL CHEMISTRY: APPLICATIONS FOR THE LABORATORY AND INDUSTRIAL PROCESS MONITORING

The identification and quantification of targeted α- and β-emitting radionuclides via destructive analysis in complex radioactive liquid matrices is highly challenging. Analyses are typically accomplished at on- or off-site laboratories through laborious sample preparation steps and extensive chemical separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, alpha energy spectroscopy, mass spectrometry). Analytical results may take days or weeks to report. When an industrial-scale plant requires periodic or continuous monitoring of radionuclides as an indication of the composition of its feed stream, diversion of safeguarded nuclides, or of plant operational conditions (for example), radiochemical measurements should be rapid, but not at the expense of precision and accuracy. Scientists at Pacific Northwest National Laboratory have developed and characterized a host of automated radioanalytical systems designed to perform reproducible and rapid radioanalytical processes. Platforms have been assembled for 1) automation and acceleration of sample analysis in the laboratory and 2) automated monitors for monitoring industrial scale nuclear processes on-line with near-real time results. These methods have been applied to the analysis of environmental-level actinides and fission products to high-level nuclear process fluids. Systems have been designed to integrate a number of discrete sample handling steps, including sample pretreatment (e.g., digestion and valence state adjustment) and chemical separations. The systems have either utilized on-line analyte detection or have collected the purified analyte fractions for off-line measurement applications. One PNNL system of particular note is a fully automated prototype on-line radioanalytical system designed for the Waste Treatment Plant at Hanford, WA, USA. This system demonstrated nearly continuous destructive analysis of the soft β-emitting radionuclide 99Tc in nuclear tank waste feed solutions. The system is compact, fully self-calibrating, and analytical results can be immediately transmitted to on- or off-site locations. This platform exemplifies how automation can be integrated into reprocessing facilities to support the needs of international nuclear safeguards and reprocessing plant operational monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy Storage and Decarbonization Analysis for Energy Regulators: Technical Analysis for the Illinois Commerce Commission

Jurisdictions around the world are enacting and enforcing an increasing number of policies to fight climate change, leading to higher penetration of variable renewable energy (VRE) and energy storage systems (ESSs) in the power grid. One of the biggest challenges associated with this process is the evaluation of the appropriate amount of ESS required to mitigate the variability of the VREs and achieve decarbonization goals of a particular jurisdiction. This report presents methodologies developed and results obtained for determining the minimum amount of ESS required to adequately serve load in a system where fossil fueled generators are being replaced by VREs over the next two decades. This technical analysis is performed by Sandia National Laboratories for the DOE Office of Electricity Energy Storage Program in collaboration with the Illinois Commerce Commission (ICC). The Illinois MISO Zone 4 is used as a case study. Several boundary conditions are investigated in this analysis including capacity adequacy and energy adequacy to determine the quantity of ESS required for MISO Zone 4. Multiple scenarios are designed and evaluated to incorporate the impact of varying capacity values of VREs and on the resource adequacy of the system. Several retirement scenarios involving fossil-fueled assets are also considered. Based on the current plans of new additions and retirements of generating assets, the results of the technical analysis indicate that Illinois MISO Zone 4 will require a significant quantity of ESS to satisfy their electricity demand over the next two decades.

25 ENERGY STORAGE↗

Independent Analyses of Antares R1 Core Design

This report summarizes the reactor analysis work performed by Oak Ridge National Laboratory (ORNL) for Antares Nuclear Incorporated's R1 Mark-1 heat pipe reactor design. The work was performed under a collaboration through the Department of Energy GAIN Nuclear Energy Voucher program. The purpose of this work is to perform an independent reactor analysis of the Antares reactor design and, where possible, compare ORNL's results with the results obtained by Antares. The overarching goal is to provide Antares with an independent review and calculation of their design, thereby contributing to Antares' mission to further their reactor design concept. A report with all ORNL technical results and proprietary details was provided to Antares Nuclear Incorporated separately; the present report provides a summary of the work completed, and all proprietary information is omitted. The independent reactor analysis was performed using both the SCALE code system for neutronics analysis and Flownex for thermal hydraulics analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration of the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite

The SAM suite of instruments on the "Curiosity" Rover of the Mars Science Laboratory (MSL) is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The mission of the MSL investigations is to advance beyond the successful search for aqueous transformation in surface environments at Mars toward a quantitative assessment of habitability and preservation through a series of chemical and geological measurements. The SAM suite was delivered in December 2010 (Figure 1) to the Jet Propulsion Laboratory for integration into the Curiosity Rover. We previously outlined the range of SAM solid and gas calibrations implemented or planned and here we discuss a specific set of calibration experiments to establish the response of the SAM Quadrupole Mass Spectrometer (QMS) to the four most abundant gases in the Martian atmosphere CO2, N2, Ar, and O2, A full SAM instrument description and calibration report is presently in preparation.

Mahaffy, P. R.↗

NONLINEAR SOIL-STRUCTURE INTERACTION ANALYSIS USING CO-SIMULATION

Nonlinear soil-structure interaction (NLSSI) analysis methods are currently being developed at Idaho National Laboratory. Appendix B in ASCE (2016) includes a framework for performing NLSSI analysis. For NLSSI analysis to be widely implemented in industry, it is important to demonstrate that accurate response in dynamically loaded, nonlinear models can be achieved in an efficient manner. Both explicit and implicit dynamic solvers are applicable to NLSSI. When considering cpu time, an explicit dynamic solver is often desirable for large models with no features (e.g. small elements, stiff elements, or stiffness damping) that can drive the time step unreasonably small. An implicit dynamic solver may be desirable in models not well suited for an explicit solver. A further option is co-simulation where a portion of the model is run with an explicit dynamic solver and the rest of the model is run with an implicit dynamic solver. This study explores NLSSI examples where co-simulation could be the most cpu efficient modelling strategy.

99 GENERAL AND MISCELLANEOUS↗

Microfluidic In-Situ Spectrophotometric Approaches to Tackle Actinides Analysis in Multiple Oxidation States

The study and development of present and future processes for the treatment/recycling of spent nuclear fuels require many steps, from design in the laboratory to setting up on an industrial scale. In all of these steps, analysis and instrumentation are key points. For scientific reasons (small-scale studies, control of phenomena, etc.) but also with regard to minimizing costs, risks, and waste, such developments are increasingly carried out on milli- or microfluidic devices. The logic is the same for the chemical analyses associated with their follow-up and interpretation. Due to this, over the last few years, opto–microfluidic analysis devices adapted to the monitoring of different processes (dissolution, liquid–liquid extraction, precipitation, etc.) have been increasingly designed and developed. In this work, we prove that photonic lab-on-a-chip (PhLoC) technology is fully suitable for all actinides concentration monitoring along the plutonium uranium refining extraction (plutonium, uranium, reduction, extraction, or Purex) process. Several PhLoC microfluidic platforms were specifically designed and used in different nuclear research and development (R&D) laboratories, to tackle actinides analysis in multiple oxidation states even in mixtures. The detection limits reached (tens of µmol·L −1 ) are fully compliant with on-line process monitoring, whereas a range of analyzable concentrations of three orders of magnitude can be covered with less than 150 µL of analyte. Finally, this work confirms the possibility and the potential of coupling Raman and ultraviolet–visible (UV–Vis) spectroscopies at the microfluidic scale, opening the perspective of measuring very complex mixtures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty Analysis of Sonic Boom Levels Measured in a Simulator at NASA Langley

A sonic boom simulator has been constructed at NASA Langley Research Center for testing the human response to sonic booms heard indoors. Like all measured quantities, sonic boom levels in the simulator are subject to systematic and random errors. To quantify these errors, and their net influence on the measurement result, a formal uncertainty analysis is conducted. Knowledge of the measurement uncertainty, or range of values attributable to the quantity being measured, enables reliable comparisons among measurements at different locations in the simulator as well as comparisons with field data or laboratory data from other simulators. The analysis reported here accounts for acoustic excitation from two sets of loudspeakers: one loudspeaker set at the facility exterior that reproduces the exterior sonic boom waveform and a second set of interior loudspeakers for reproducing indoor rattle sounds. The analysis also addresses the effect of pressure fluctuations generated when exterior doors of the building housing the simulator are opened. An uncertainty budget is assembled to document each uncertainty component, its sensitivity coefficient, and the combined standard uncertainty. The latter quantity will be reported alongside measurement results in future research reports to indicate data reliability.

Rathsam, Jonathan↗

Measurement Results from Los Alamos National Laboratory to Support Certification of a New High Purity 244 Pu Isotope Dilution Tracer

A 244 Pu material was identified that contains a minimum quantity of impurity Pu isotopes that will be suitable for low-level coupled Pu concentration and isotopic composition measurements. Measurement effort s have been initiated in several international laboratories that possess mature Pu isotopic analysis capabilities to determine the concentration of Pu in the 244 Pu material and to determine its isotopic composition with high degrees of quality. Preparation of isotope dilution mixes were prepared and distributed to LANL and other participating laboratories by Lawrence Livermore National Laboratory in 2017.

07 ISOTOPE AND RADIATION SOURCES↗

Preprocessing Analysis of the Multi Isotope Process Monitor

The Multi-Isotope Process (MIP) Monitor is a nondestructive monitoring methodology to detect diversion and tampering of nuclear material at a reprocessing facility. The system measures the gamma-emitting isotopes in different stages of the reprocessing cycle through passive gamma spectroscopy. The indicators of isotopic distributions are measured and evaluated in near-real time by comparing measured spectra to expected, normal process spectra through multivariate analysis. The MIP monitor framework is compatible with medium resolution gamma detectors that can be easily deployed in an existing facility. In FY15, the MIP monitor was deployed at the H-Canyon Facility at Savannah River National Laboratory (SRNL) to develop and evaluate analysis algorithms for future in situ deployment. This paper discusses recent results from analysis of the data collected at SRNL. New results examine the preprocessing step of spectral alignment that is associated with the MIP monitor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Tank 5F Final Characterization Samples-2011 (U)

The Savannah River National Laboratory (SRNL) was requested by SRR to provide sample preparation and analysis of the Tank 5F final characterization samples to determine the residual tank inventory prior to grouting. Two types of samples were collected and delivered to SRNL: floor samples across the tank and subsurface samples from mounds near risers 1 and 5 of Tank 5F. These samples were taken from Tank 5F between January and March 2011. These samples from individual locations in the tank (nine floor samples and six mound Tank 5F samples) were each homogenized and combined in a given proportion into 3 distinct composite samples to mimic the average composition in the entire tank. These Tank 5F composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 5F composite samples include bulk density and water leaching of the solids to account for water soluble species. With analyses for certain challenging radionuclides as the exception, all composite Tank 5F samples were analyzed and reported in triplicate. The target detection limits for isotopes analyzed were based on customer desired detection limits as specified in the technical task request documents. SRNL developed new methodologies to meet these target detection limits and provide data for the extensive suite of components. While many of the target detection limits were met for the species characterized for Tank 5F, as specified in the technical task request, some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The Technical Task Request allows that while the analyses of these isotopes is needed, meeting the detection limits for these isotopes is a lower priority than meeting detection limits for the other specified isotopes. The isotopes whose detection limits were not met in all cases included the following: Al-26, Sn-126, Sb-126, Sb-126m, Eu-152 and Cf-249. SRNL, in conjunction with the plant customer, reviewed all these cases and determined that the impacts were negligible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Tank 5F Final Characterization Samples-2011 (U)

The Savannah River National Laboratory (SRNL) was requested by SRR to provide sample preparation and analysis of the Tank 5F final characterization samples to determine the residual tank inventory prior to grouting. Two types of samples were collected and delivered to SRNL: floor samples across the tank and subsurface samples from mounds near risers 1 and 5 of Tank 5F. These samples were taken from Tank 5F between January and March 2011. These samples from individual locations in the tank (nine floor samples and six mound Tank 5F samples) were each homogenized and combined in a given proportion into 3 distinct composite samples to mimic the average composition in the entire tank. These Tank 5F composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 5F composite samples include bulk density and water leaching of the solids to account for water soluble species. With analyses for certain challenging radionuclides as the exception, all composite Tank 5F samples were analyzed and reported in triplicate. The target detection limits for isotopes analyzed were based on customer desired detection limits as specified in the technical task request documents. SRNL developed new methodologies to meet these target detection limits and provide data for the extensive suite of components. While many of the target detection limits were met for the species characterized for Tank 5F, as specified in the technical task request, some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The Technical Task Request allows that while the analyses of these isotopes is needed, meeting the detection limits for these isotopes is a lower priority than meeting detection limits for the other specified isotopes. The isotopes whose detection limits were not met in all cases included the following: Al-26, Sn-126, Sb-126, Sb-126m, Eu-152 and Cf-249. SRNL, in conjunction with the plant customer, reviewed all these cases and determined that the impacts were negligible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Design & Analysis Code, CACTUS, for Predicting Crossflow Hydrokinetic Turbine Performance

CACTUS, developed by Sandia National Laboratories, is an open-source code for the design and analysis of wind and hydrokinetic turbines. While it has undergone extensive validation for both vertical axis and horizontal axis wind turbines, and it has been demonstrated to accurately predict the performance of horizontal (axial-flow) hydrokinetic turbines, its ability to predict the performance of crossflow hydrokinetic turbines has yet to be tested. The present study addresses this problem by comparing the predicted performance curves derived from CACTUS simulations of the U.S. Department of Energy’s 1:6 scale reference model crossflow turbine to those derived by experimental measurements in a tow tank using the same model turbine at the University of New Hampshire. It shows that CACTUS cannot accurately predict the performance of this crossflow turbine, raising concerns on its application to crossflow hydrokinetic turbines generally. The lack of quality data on NACA 0021 foil aerodynamic (hydrodynamic) characteristics over the wide range of angles of attack (AoA) and Reynolds numbers is identified as the main cause for poor model prediction. A comparison of several different NACA 0021 foil data sources, derived using both physical and numerical modeling experiments, indicates significant discrepancies at the high AoA experienced by foils on crossflow turbines. Users of CACTUS for crossflow hydrokinetic turbines are, therefore, advised to limit its application to higher tip speed ratios (lower AoA), and to carefully verify the reliability and accuracy of their foil data. Accurate empirical data on the aerodynamic characteristics of the foil is the greatest limitation to predicting performance for crossflow turbines with semi-empirical models like CACTUS. Future improvements of CACTUS for crossflow turbine performance prediction will require the development of accurate foil aerodynamic characteristic data sets within the appropriate ranges of Reynolds numbers and AoA.

13 HYDRO ENERGY↗