Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOAD TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Flight simulation testing equipment for composite material systems

A test program is discussed which aims at establishing the time-temperature-stress characteristics of several classes of high-temperature composite materials in order to determine their suitability for applications in supersonic cruise aircraft. Five advanced composite materials (a boron epoxy, a boron polyimide, a graphite epoxy, a graphite polyimide, and diffusion-bonded boron aluminum) are being evaluated using a flight-test simulator capable of long-term automatic testing based on random loading and realistic flight temperature profiles. The design, construction, and checkout of this simulator are described along with the digital load programmer, load magnitude controllers, the hydraulic pumping system, the heating and cooling systems, the control console, and the data recording system. Typical results for short-term tests performed at constant temperatures and accelerated load rates are presented in terms of a random-load spectrum and a wearout model.

Haskins, J. F.↗

Advanced Natural Gas Reciprocating Engine(s)

Energy independence and fuel savings are hallmarks of the nation’s energy strategy. The advancement of natural gas reciprocating engine power generation technology is critical to the nation’s future. A new engine platform that meets the efficiency, emissions, fuel flexibility, cost and reliability/maintainability targets will enable American manufacturers to have highly competitive products that provide substantial environmental and economic benefits in the US and in international markets. Along with Cummins and Waukesha, Caterpillar participated in a multiyear cooperative agreement with the Department of Energy to create a 50% efficiency natural gas powered reciprocating engine system with a 95% reduction in NOx emissions by the year 2013. This platform developed under this agreement will be a significant contributor to the US energy strategy and will enable gas engine technology to remain a highly competitive choice, meeting customer cost of electricity targets, and regulatory environmental standard. Engine development under the Advanced Reciprocating Engine System (ARES) program was divided into phases, with the ultimate goal being approached in a series of incremental steps. This incremental approach would promote the commercialization of ARES technologies as soon as they emerged from development and would provide a technical and commercial foundation of later-developing technologies. Demonstrations of the Phase I and Phase II technology were completed in 2004 and 2008, respectively. Program tasks in Phase III included component and system development and testing from 2009-2012. Two advanced ignition technology evaluations were investigated under the ARES program: laser ignition and distributed ignition (DIGN). In collaboration with Colorado State University (CSU), a laser ignition system was developed to provide ignition at lean burn and high boost conditions. Much work has been performed in Caterpillar’s DIGN program under the ARES program. This work has consisted of both modeling and single cylinder engine experiments to quantify DIGN performance. The air handling systems of natural gas engines dissipate a percentage of available energy as a result of both flow losses and turbomachinery inefficiencies. An analytical study was initiated to increase compressor efficiency by employing a 2-stage inter-cooled compressor. Caterpillar also studied a turbo-compound system that employs a power turbine to recover energy from the exhaust gases for improved engine efficiency. Several other component and system investigations were undertaken during the final phase of the program to reach the ultimate ARES goals. An intake valve actuation system was developed and tested to improve engine efficiency, durability and load acceptance. Analytical modeling and materials testing were performed to evaluate the performance of steel pistons and compacted graphite iron cylinder head. Effort was made to improve the detonation sensing system by studying and comparing the performance of different pressure sensors. To reduce unburned hydrocarbon emissions, different camshafts were designed and built to investigate the effect of exhaust valve opening timing and value overlap. 1-D & 3-D coupled simulation was used to study intake and exhaust manifold dynamics with the goal of reducing load in-balance between cylinders. Selective catalytic reduction with on-board reductant generation to reduce NOx emissions was also engine tested. An effective mean to successfully deploy ARES technologies into the energy markets is to deploy demonstration projects in the field. In 2010, NETL and Caterpillar agreed to include a new “opportunity fuel” deliverable and two field demonstrations in the ARES program. An Organic Rankine Cycle system was designed with production intent incorporating lessons learned from the Phase II demonstration. Unfortunately, business conditions caused Caterpillar to cancel this demonstration in 2011. Nonetheless, Caterpillar partnered with a local dealer to deploy an ARES class engine using syngas from a biomass gasifier as the DE-FC26-01CH11079 primary combustion fuel in Gleason, TN. Upon the successful start-up and commissioning of the demonstration unit, ownership of the system was transferred to the dealer. In order to further our understanding of syngas combustion, a fundamental combustion study on syngas combustion at high pressure and lean condition was conducted through the collaboration with University of Southern California. A Methane program was also developed to rate engine performance for various compositions of syngas using empirical data obtained at CSU. While much work remains in terms of extending and integrating these developments into commercial products, it is evident that engine manufacturers on our own or through private consortium efforts could not have overcome the financial hurdles to drive these improvements into reciprocating engine and system capabilities, helping maintain the natural gas reciprocating engine power generation technology as a strong option for electric power markets, both in the United States and worldwide.

20 FOSSIL-FUELED POWER PLANTS↗

Scale-Up Testing-Foam as a Remedial Amendment Carrier

This paper describes results from intermediate-scale, two-dimensional testing of foam injection into sedimentary materials collected from the U.S. Department of Energy (DOE) Hanford Site. The testing was performed to evaluate the effects of delivery pressure, injection rate, foam stability, foam quality, and formation heterogeneities on the migration of foam, water, remediation amendment, and contaminants within a sedimentary volume. Testing was accomplished in a test bed that is configured in the form of two thin rectangular boxes. Each of the boxes holds approximately 135 liters (255 kilograms) of sediment. Foam was injected into each box through a segment of polyvinyl chloride slotted well casing, and air was extracted from the boxes through a similar system. Four sets of tests were conducted. During Test 1, both of the boxes were loaded in a homogeneous manner, while in Tests 2, 3, and 4, both of the boxes were loaded so as to contain two rectangular zones of heterogeneity. In addition, a zone of the sediment contained in the test bed used for Test 4 was augmented with uranium-rich calcite to produce a known concentration of uranium. The injection rate varied between the boxes during the Test 1 but was the same for each box during the final three tests. The foam generation formula for Tests 1 and 2 consisted of an aqueous solution of anionic surfactant. The foam generation formula used in Test 3 consisted of an aqueous solution of anionic surfactant and contained 25,000 milligrams per liter (mg/L) of phosphate in the form of a 9:1 mixture of sodium phosphate and sodium tripolyphosphate. The foam generating formula used in Test 4 consisted of an aqueous solution of an anionic surfactant and a nonionic surfactant and also contained 5,000 mg/L of phosphate as the aforementioned mixture. Subsequent to each of the four tests, the test beds were disassembled, and samples of the sediments were taken and analyzed for a number of parameters, depending on the specific test. This paper presents the results of the intermediate-scale testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fatigue testing a plurality of test specimens and method

Described is a fatigue testing apparatus for simultaneously subjecting a plurality of material test specimens to cyclical tension loading to determine the fatigue strength of the material. The fatigue testing apparatus includes a pulling head having cylinders defined therein which carry reciprocating pistons. The reciprocation of the pistons is determined by cyclical supplies of pressurized fluid to the cylinders. Piston rods extend from the pistons through the pulling head and are attachable to one end of the test specimens, the other end of the test specimens being attachable to a fixed base, causing test specimens attached between the piston rods and the base to be subjected to cyclical tension loading. Because all the cylinders share a common pressurized fluid supply, the breaking of a test specimen does not substantially affect the pressure of the fluid supplied to the other cylinders nor the tension applied to the other test specimens.

Hodo, James D.↗

Edge delamination of composite laminates subject to combined tension and torsional loading

Delamination is a common failure mode of laminated composite materials. Edge delamination is important since it results in reduced stiffness and strength of the laminate. The tension/torsion load condition is of particular significance to the structural integrity of composite helicopter rotor systems. Material coupons can easily be tested under this type of loading in servo-hydraulic tension/torsion test stands using techniques very similar to those used for the Edge Delamination Tensile Test (EDT) delamination specimen. Edge delamination of specimens loaded in tension was successfully analyzed by several investigators using both classical laminate theory and quasi-three dimensional (Q3D) finite element techniques. The former analysis technique can be used to predict the total strain energy release rate, while the latter technique enables the calculation of the mixed-mode strain energy release rates. The Q3D analysis is very efficient since it produces a three-dimensional solution to a two-dimensional domain. A computer program was developed which generates PATRAN commands to generate the finite element model. PATRAN is a pre- and post-processor which is commonly used with a variety of finite element programs such as MCS/NASTRAN. The program creates a sufficiently dense mesh at the delamination crack tips to support a mixed-mode fracture mechanics analysis. The program creates a coarse mesh in those regions where the gradients in the stress field are low (away from the delamination regions). A transition mesh is defined between these regions. This program is capable of generating a mesh for an arbitrarily oriented matrix crack. This program significantly reduces the modeling time required to generate these finite element meshes, thus providing a realistic tool with which to investigate the tension torsion problem.

Hooper, Steven J.↗

Tank Closure Cesium Removal Project CST Simulant Cesium Batch Contact Kinetics Test Results and Column Performance Predictions

To evaluate the cesium removal capabilities of the caustic-washed R9120-B version of crystalline silicotitanate (CST) ion exchange media from Savannah River Site (SRS) waste during Tank Closure Cesium Removal (TCCR) column processing, batch contact kinetics tests were performed at 23 °C in SRS Average simulant. Cesium loading kinetics data was also collected (in current and previous testing; King, et al., 2018a) using the same simulant for an older CST sample (IE- 911) which was caustic-washed by the vendor many years ago and was recently retrieved from drums stored at SRS. (Note that R9120-B and IE-911 are believed to be identical materials, after the R9120-B was caustic washed by SRNL, and differ only by particle size and manufacturing date, and thus can be considered different batches). Although cesium loading kinetics testing can be conducted more rigorously using dynamic column tests, the batch contact method requires less simulant and considerably less experimental effort. Average percent removal data for batch contact samples for the two CST batches are provided in Table ES-1. Faster cesium uptake was observed with IE-911, although the loading rates for the two media batches were similar. After 5.5 hours of CST contact, 81% cesium removal was observed with R9120-B versus 86% removal with IE-911. Although these differences are small, the trend is consistent across the timed results, with the larger bead material always loading slower. These seemingly small differences in percent removal are believed to have a large impact on the column performance. Cesium loading curves for the two CST batches are provided in Figure ES-1 below. Faster cesium loading with IE-911 CST is presumed to be associated with the smaller average particle diameter (408 μm mean volume diameter) versus R9120-B (572 μm diameter). Cesium loading kinetic data was needed to conduct column performance comparisons (i.e., model predictions) for the two CST batches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fatigue failure load indicator

An indicator for recording the load at which a fatigue specimen breaks during the last cycle of a fatigue test is described. A load cell is attached to the specimen which is alternately subjected to tension and compression loads. The output of the load cell which is proportional to the load on the specimen is applied to the input of a peak detector. Each time the specimen is subjected to a compression load, means are provided for applying a positive voltage to the rest of the peak detector to reset it. During the last cycle of the tension load the peak detector measures the maximum load on the specimen. Means are provided for disconnecting the load cell from the peak detector when there is a failure in the specimen.

Imig, L. A.↗

Instrumentation applications to Space Shuttle models and thermal protection system tiles tested in NASA-AMES wind tunnels

The highlights of the many wind-tunnel tests conducted in the course of the Space Shuttle development program are presented with emphasis on instrumentation applications. The examples of tests discussed include airframe aerodynamics, aerodynamic heating, aerodynamic noise, tile dynamic response, and tile loads. Many of the tests were conducted with standard wind-tunnel instrumentation. Most of the more unusual instrumentation requirements were related to the thermal protection system, where some pressure-sensor concepts were adapted to measure airloads on tiles. These measurements provided the only quantitative data that could be used to confirm the airload analysis procedure. Limited applications of computers to experimental control, in conjunction with data taken during Shuttle tests, have resulted in substantial benefits in overall test efficiency.

Coe, C. F.↗

Investigation of Low-temperature Solders for Cryogenic Wind Tunnel Models

The advent of high Reynolds number cryogenic wind tunnels has forced alteration of manufacturing and assembly techniques and eliminated usage of many materials associated with conventional wind tunnel models. One of the techniques affected is soldering. Solder alloys commonly used for wind tunnel models are susceptible to low-temperature embrittlement and phase transformation. The low-temperature performance of several solder alloys is being examined during research and development activities being conducted in support of design and fabrication of cryogenic wind tunnel models. Among the properties examined during these tests are shear strength, surface quality, joint stability, and durability when subjected to dynamic loading. Results of these tests and experiences with recent models are summarized.

Firth, G. C.↗

Characterization and modeling of tensile behavior of ceramic woven fabric composites

This paper examines the tensile behavior of SiC/SiC fabric composites. In the characterization effort, the stress-strain relation and damage evolution are studied with a series of loading and unloading tensile test experiments. The stress-strain relation is linear in response to the initial loading and becomes nonlinear when loading exceeds the proportional limit. Transverse cracking has been observed to be a dominant damage mode governing the nonlinear deformation. The damage is initiated at the inter-tow pores where fiber yarns cross over each other. In the modeling work, the analysis is based upon a fiber bundle model, in which fiber undulation in the warp and fill directions and gaps among fiber yarns have been taken into account. Two limiting cases of fabric stacking arrangements are studied. Closed form solutions are obtained for the composite stiffness and Poisson's ratio. Transverse cracking in the composite is discussed by applying a constant failure strain criterion.

Kuo, Wen-Shyong↗

Tank Tests of NACA Model 40 Series of Hulls for Small Flying Boats and Amphibians

The NACA model 40 series of flying-boat hull models consists of 2 forebodies and 3 afterbodies combined to provide several forms suitable for use in small marine aircraft. One forebody is the usual form with hollow bow sections and the other has a bottom surface that is completely developable from bow to step. The afterbodies include a short pointed afterbody with an extension for the tail surfaces, a long afterbody similar to that of a seaplane float but long enough to carry the tail surfaces, and a third obtained by fitting a second step in the latter afterbody. The various combinations were tested in the NACA Tank by the general method over a suitable range of loadings. Fixed-trim tests were made for all speeds likely to be used and free-to-trim tests were made at low speeds to slightly beyond the hump speed. The characteristics of the hulls at best trim angles have been deduced from the data of the tests at fixed trim angles and are given in the form of nondimensional coefficients applicable to any size hull.

Parkinson, John B↗

Estimation of the Unsteady Aerodynamic Load on Space Shuttle External Tank Protuberances from a Component Wind Tunnel Test

At the wake of the Columbia (STS-107) accident it was decided to remove the Protuberance Aerodynamic Load (PAL) Ramp that was originally intended to protect various protuberances outside of the Space Shuttle External Tank from high buffet load induced by cross-flows at transonic speed. In order to establish the buffet load without the PAL ramp, a wind tunnel test was conducted where segments of the protuberances were instrumented with dynamic pressure transducers; and power-spectra of sectional lift and drag forces at various span-wise locations between two adjacent support brackets were measured under different cross flow angles, Mach number and other conditions. Additionally, frequency-dependent spatial correlations between the sectional forces were also established. The sectional forces were then adjusted by the correlation length to establish span-averaged spectra of normal and lateral forces that can be suitably "added" to various other unsteady forces encountered by the protuberance. This paper describes the methodology used for calculating the correlation-adjusted power spectrum of the buffet load. A second part of the paper describes wind-tunnel results on the difference in the buffet load on the protuberances with and without the PAL ramp. In general when the ramp height is the same as that of the protuberance height, such as that found on the liquid Oxygen part of the tank, the ramp is found to cause significant reduction of the unsteady aerodynamic load. However, on the liquid Hydrogen part of the tank, where the Oxygen feed-line is far larger in diameter than the height of the PAL ramp, little protection is found to be available to all but the Cable Tray.

Panda, J.↗

Estimation of the Unsteady Aerodynamic Load on Space Shuttle External Tank Protuberances from a Component Wind Tunnel Test

At the wake of the Columbia (STS-107) accident it was decided to remove the Protuberance Aerodynamic Load (PAL) Ramp that was originally intended to protect various protuberances outside of the Space Shuttle External Tank from high buffet load induced by cross-flows at transonic speed. In order to establish the buffet load without the PAL ramp, a wind tunnel test was conducted where segments of the protuberances were instrumented with dynamic pressure transducers; and power-spectra of sectional lift and drag forces at various span-wise locations between two adjacent support brackets were measured under different cross flow angles, Mach number and other conditions. Additionally, frequency-dependent spatial correlations between the sectional forces were also established. The sectional forces were then adjusted by the correlation length to establish span-averaged spectra of normal and lateral forces that can be suitably "added" to various other unsteady forces encountered by the protuberance. This paper describes the methodology used for calculating the correlation-adjusted power spectrum of the buffet load. A second part of the paper describes wind-tunnel results on the difference in the buffet load on the protuberances with and without the PAL ramp. In general when the ramp height is the same as that of the protuberance height, such as that found on the liquid Oxygen part of the tank, the ramp is found to cause significant reduction of the unsteady aerodynamic load. However, on the liquid Hydrogen part of the tank, where the Oxygen feed-line is far larger in diameter than the height of the PAL ramp, little protection is found to be available to all but the Cable Tray.

Panda, Jayatana↗

Wear Behavior of an Ultra-High-Strength Eutectoid Steel

Wear behavior of an ultra-high-strength AISI 1080 steel developed through incomplete austenitization-based combined cyclic heat treatment is investigated in comparison with annealed and conventional hardened and tempered conditions against an alumina disk (sliding speed = 1 m s{sup −1}) using a pin-on-disk tribometer at a load range of 7.35-14.7 N. On a gross scale, the mechanism of surface damage involves adhesive wear coupled with abrasive wear (microcutting effects in particular) at lower loads. At higher loads, mainly the abrasive wear (both microcutting and microploughing mechanisms) and evolution of adherent oxide are observed. Besides, microhardness of matrix increases with load indicating substantial strain hardening during wear test. The rate of overall wear is found to increase with load. As-received annealed steel with the lowest initial hardness suffers from severe abrasive wear, thereby exhibiting the highest wear loss. Such a severe wear loss is not observed in conventional hardened and tempered and combined cyclic heat treatment conditions. Combined cyclic heat-treated steel exhibits the greatest wear resistance (lowest wear loss) due to its initial high hardness and evolution of hard abrasion-resistant tribolayer during wear test at higher load.

36 MATERIALS SCIENCE↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geometrically Necessary Dislocation Analysis of Deformation Mechanism for Magnesium under Fatigue Loading at 0 °C

This study focused on the analysis of geometrically necessary dislocation (GND) densities for five selected fine-grained magnesium samples. Among the samples, three were tested under different fatigue-loading conditions at 0 °C, one experienced quasi-static tensile loading at 0 °C, and one represented the as-rolled state. The fatigue-tested samples were chosen according to the relationship between the maximum loading stress of a test and the material’s yield strength. This study provides new insights on the deformation mechanism of fine-grained magnesium at 0 °C. It is observed that the average GND densities were increased by 95~111% for the tested samples when compared with the as-rolled sample. It is especially interesting that there is a significant increase in the average GND density for the sample that experienced the fatigue loading with a low-maximum applied stress, and the maximum applied stress was lower than the material’s yield strength. This observation implies that the grain boundary mediated the dislocation-emission mechanism.

Li, Qizhen↗

Thermal-structural panel buckling tests

A titanium-matrix-composite (TMC) hat-stiffened panel of 61 cm sq area and 3.175 cm thick was nondestructively tested to 649 C to examine its buckling characteristics. Compressive loads were applied to the panel in a 978.6 kN uniaxial load frame system. High-temperature testing was performed using quartz lamp heating. A single-strain-age force/stiffness buckling prediction technique was developed to predict panel buckling loads. For the monolithic panel, these test predictions correlated within 10 percent with a finite-element buckling analyses performed elsewhere. Comparisons between force/stiffness predictions and analyses for the TMC panel are in progress.

Thompson, Randolph C.↗