Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Multilevel learning-based segmentation of ill-defined and spiculated masses in mammograms

Purpose: A learning-based approach integrating the use of pixel-level statistical modeling and spiculation detection is presented for the segmentation of mammographic masses with ill-defined margins and spiculations. Methods: The algorithm involves a multiphase pixel-level classification, using a comprehensive group of features computed from regional intensity, shape, and textures, to generate a mass-conditional probability map (PM). Then, the mass candidate, along with the background clutters consisting of breast fibroglandular and other nonmass tissues, is extracted from the PM by integrating the prior knowledge of shape and location of masses. A multiscale steerable ridge detection algorithm is employed to detect spiculations. Finally, all the object-level findings, including mass candidate, detected spiculations, and clutters, along with the PM, are integrated by graph cuts to generate the final segmentation mask. Results: The method was tested on 54 masses (51 malignant and 3 benign), all with ill-defined margins and irregular shape or spiculations. The ground truth delineations were provided by five experienced radiologists. Area overlapping ratio of 0.689 ({+-}0.160) and 0.540 ({+-}0.164) were obtained for segmenting entire mass and margin portion only, respectively. Williams index of area and contour based measurements indicated that the segmentation results of the algorithm agreed well with the radiologists' delineation. Conclusions: The proposed approach could closely delineate the mass body. Most importantly, it is capable of including mass margin and its spicule extensions which are considered as key features for breast lesion analyses.

60 APPLIED LIFE SCIENCES↗

Evaluating Image Classification Deep Convolutional Neural Network Architectures for Remaining Useful Life Estimation of Turbofan Engines

Accurate estimation of the remaining useful life (RUL) is a key component of condition-based maintenance (CBM) and prognosis and health management (PHM). Data-based models for the estimation of RUL are of particular interest because expert knowledge of systems is not always available, and physical modeling is often not feasible. Additionally, using data-based models, which make decisions based on raw sensor data, allow features to be learned instead of manually determined. In this work, deep convolutional neural network (CNN) architectures are investigated for their ability to estimate the RUL of turbofan engines. To improve the accuracy of the models, CNN architectures, which have proven successful in image classification, are implemented and tested. Specifically, the blocks used in the Visual Geometry Group (VGG) architecture, inception modules used in the GoogLeNet architecture, and residual blocks used in the ResNet architecture are incorporated. To account for varying flight lengths, the input to the models is a window of time series data collected from the engine under test. Window locations at the climb, cruise, and descent stages are considered. To further improve the RUL estimations, multiple overlapping windows at each location are used. This increases the amount of training data available and is found to increase the accuracy of the resulting RUL estimations by averaging the estimates from all overlapping segments. The model is trained and tested using the new Commercial Modular Aero-Propulsion System Simulation (N-CMAPSS) data set, and high prognosis accuracy was achieved. Furthermore, this work expands on the model developed and used in the 2021 PHM Society Data Challenge, which received second place.

convolutional neural networks↗

TU-F-18A-03: Improving Tissue Segmentation for Monte Carlo Dose Calculation Using DECT Data

Purpose: To develop a new segmentation technique using dual energy CT (DECT) to overcome limitations related to segmentation from a standard Hounsfield unit (HU) to electron density (ED) calibration curve. Both methods are compared with a Monte Carlo analysis of dose distribution. Methods: DECT allows a direct calculation of both ED and effective atomic number (EAN) within a given voxel. The EAN is here defined as a function of the total electron cross-section of a medium. These values can be effectively acquired using a calibrated method from scans at two different energies. A prior stoichiometric calibration on a Gammex RMI phantom allows us to find the parameters to calculate EAN and ED within a voxel. Scans from a Siemens SOMATOM Definition Flash dual source system provided the data for our study. A Monte Carlo analysis compares dose distribution simulated by dosxyz-nrc, considering a head phantom defined by both segmentation techniques. Results: Results from depth dose and dose profile calculations show that materials with different atomic compositions but similar EAN present differences of less than 1%. Therefore, it is possible to define a short list of basis materials from which density can be adapted to imitate interaction behavior of any tissue. Comparison of the dose distributions on both segmentations shows a difference of 50% in dose in areas surrounding bone at low energy. Conclusion: The presented segmentation technique allows a more accurate medium definition in each voxel, especially in areas of tissue transition. Since the behavior of human tissues is highly sensitive at low energies, this reduces the errors on calculated dose distribution. This method could be further developed to optimize the tissue characterization based on anatomic site.

60 APPLIED LIFE SCIENCES↗

Correction to: The effect of beta blocker withdrawal on adenosine myocardial perfusion imaging

Regrettably the original version of the above article contained errors in Table 2 and wrong values in the text. The corrected table is presented here and the values which have been corrected now appear in bold text. Page 1223 abstract Global MBF showed an increase from 180.2 ± 59.9 to 193.6 ± 60.8 mL minute/100 g (P = .002) after beta blocker withdrawal. Page 1225 Mean systolic and mean diastolic blood pressure during adenosine were nearly identical (P = .77 and P = .79) with and without beta blocker. Mean heart rate and mean RPP during adenosine significantly increased after beta blocker withdrawal by 15.2% ± 17% (P = .001) and 16.2% ± 23% (P = .004), respectively. Page 1226 The data are listed in Table 2, lower third. Global MBF showed a significant increase by 7.4% ± 10% (P = .002) after beta blocker withdrawal. The individual data are depicted in Figure 1. All but three patients had a lower global MBF without beta blocker than with. The segmental MBF values (Figure 2) demonstrated a strong correlation over the entire range of perfusion values. The average effect was a slight perfusion shift of about 1015 mL minute-1/100 g in the range of 100-300 mL minute-1/100 g. The mCR under adenosine declined by 8.1% ± 11% (P = .038) and the normalized RPP by 16.2% ± 21% (P = .004) after betablocker discontinuation. Table 2 Hemodynamic response under adenosine, perfusion, and left-ventricular function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-BRD-07: Three-Dimensional Dose Reconstruction in the Presence of Inhomogeneities Using Fast EPID-Based Back-Projection Method

Purpose: Three-dimensional dose verification can detect errors introduced by the treatment planning system (TPS) or differences between planned and delivered dose distribution during the treatment. The aim of the study is to extend a previous in-house developed three-dimensional dose reconstructed model in homogeneous phantom to situtions in which tissue inhomogeneities are present. Methods: The method was based on the portal grey images from an electronic portal imaging device (EPID) and the relationship between beamlets and grey-scoring voxels at the position of the EPID. The relationship was expressed in the form of grey response matrix that was quantified using thickness-dependence scatter kernels determined by series of experiments. From the portal grey-value distribution information measured by the EPID the two-dimensional incident fluence distribution was reconstructed based on the grey response matrix using a fast iterative algorithm. The accuracy of this approach was verified using a four-field intensity-modulated radiotherapy (IMRT) plan for the treatment of lung cancer in anthopomorphic phantom. Each field had between twenty and twenty-eight segments and was evaluated by comparing the reconstructed dose distribution with the measured dose. Results: The gamma-evaluation method was used with various evaluation criteria of dose difference and distance-to-agreement: 3%/3mm and 2%/2 mm. The dose comparison for all irradiated fields showed a pass rate of 100% with the criterion of 3%/3mm, and a pass rate of higher than 92% with the criterion of 2%/2mm. Conclusion: Our experimental results demonstrate that our method is capable of accurately reconstructing three-dimensional dose distribution in the presence of inhomogeneities. Using the method, the combined planning and treatment delivery process is verified, offing an easy-to-use tool for the verification of complex treatments.

60 APPLIED LIFE SCIENCES↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

The Large Area Telescope on the Fermi Gamma-ray Space Telescope Mission

The Large Area Telescope (Fermi/LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view (FoV), high-energy {gamma}-ray telescope, covering the energy range from below 20 MeV to more than 300 GeV. The LAT was built by an international collaboration with contributions from space agencies, high-energy particle physics institutes, and universities in France, Italy, Japan, Sweden, and the United States. This paper describes the LAT, its preflight expected performance, and summarizes the key science objectives that will be addressed. On-orbit performance will be presented in detail in a subsequent paper. The LAT is a pair-conversion telescope with a precision tracker and calorimeter, each consisting of a 4 x 4 array of 16 modules, a segmented anticoincidence detector that covers the tracker array, and a programmable trigger and data acquisition system. Each tracker module has a vertical stack of 18 (x, y) tracking planes, including two layers (x and y) of single-sided silicon strip detectors and high-Z converter material (tungsten) per tray. Every calorimeter module has 96 CsI(Tl) crystals, arranged in an eight-layer hodoscopic configuration with a total depth of 8.6 radiation lengths, giving both longitudinal and transverse information about the energy deposition pattern. The calorimeter's depth and segmentation enable the high-energy reach of the LAT and contribute significantly to background rejection. The aspect ratio of the tracker (height/width) is 0.4, allowing a large FoV (2.4 sr) and ensuring that most pair-conversion showers initiated in the tracker will pass into the calorimeter for energy measurement. Data obtained with the LAT are intended to (1) permit rapid notification of high-energy {gamma}-ray bursts and transients and facilitate monitoring of variable sources, (2) yield an extensive catalog of several thousand high-energy sources obtained from an all-sky survey, (3) measure spectra from 20 MeV to more than 50 GeV for several hundred sources, (4) localize point sources to 0.3-2 arcmin, (5) map and obtain spectra of extended sources such as SNRs, molecular clouds, and nearby galaxies, (6) measure the diffuse isotropic {gamma}-ray background up to TeV energies, and (7) explore the discovery space for dark matter.

Astrophysics,ASTRO↗

Automated noninvasive classification of renal cancer on multiphase CT

Purpose: To explore the added value of the shape of renal lesions for classifying renal neoplasms. To investigate the potential of computer-aided analysis of contrast-enhanced computed-tomography (CT) to quantify and classify renal lesions. Methods: A computer-aided clinical tool based on adaptive level sets was employed to analyze 125 renal lesions from contrast-enhanced abdominal CT studies of 43 patients. There were 47 cysts and 78 neoplasms: 22 Von Hippel-Lindau (VHL), 16 Birt-Hogg-Dube (BHD), 19 hereditary papillary renal carcinomas (HPRC), and 21 hereditary leiomyomatosis and renal cell cancers (HLRCC). The technique quantified the three-dimensional size and enhancement of lesions. Intrapatient and interphase registration facilitated the study of lesion serial enhancement. The histograms of curvature-related features were used to classify the lesion types. The areas under the curve (AUC) were calculated for receiver operating characteristic curves. Results: Tumors were robustly segmented with 0.80 overlap (0.98 correlation) between manual and semi-automated quantifications. The method further identified morphological discrepancies between the types of lesions. The classification based on lesion appearance, enhancement and morphology between cysts and cancers showed AUC = 0.98; for BHD + VHL (solid cancers) vs. HPRC + HLRCC AUC = 0.99; for VHL vs. BHD AUC = 0.82; and for HPRC vs. HLRCC AUC = 0.84. All semi-automated classifications were statistically significant (p < 0.05) and superior to the analyses based solely on serial enhancement. Conclusions: The computer-aided clinical tool allowed the accurate quantification of cystic, solid, and mixed renal tumors. Cancer types were classified into four categories using their shape and enhancement. Comprehensive imaging biomarkers of renal neoplasms on abdominal CT may facilitate their noninvasive classification, guide clinical management, and monitor responses to drugs or interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards resolving protein structures at the atomic scale using atom probe tomography

In the field of Structural Biology, Atom Probe Tomography (APT) is in the nascent stages of development wherein coarse-grained visuals of proteins have been captured. The characterization of organic samples or biomolecules through the technique is currently limited to the detection of a few dominant signatures. The problem of indecipherable characterization can inherently be traced back to multiple forms of technique-specific responses to organic samples and consequent triggers leading to organic-sample and sample-medium interactions. While it is possible for captured manifestations of protein reconstructions to seemingly appear intact from a basic visual purview, the parameter-protein associative responses throughout the structure as a direct consequence of the inherent workings of the technique (until harmonized with organic sample complexity and behavior) and field evaporation-based factors make non-aberrative atomic associations infeasible. The work focused on identifying and theorizing the (above stated and other) fundamental mechanisms that stronghold the study of intricate atomic to higher order associations in proteins through APT. Attempts at structure elucidation of the cryogenic sample under study, through indirect associations (and methods) based on other imaging techniques, further revealed the distinct and highly distortive nature at the atomic scale deterring structural tunability and thus characterization of APT based cryogenic samples under analysis. As a direct counter to the atomic scale characterization problem, by taking the experiment-specific uncertainties, and probable APT-centric organic sample-based variabilities into account, a basic result is extracted and presented. Through mass-spectrometric and computational analysis, specific individual amino acids (Sulfur-containing protein-bound amino acids) in proteins and aspects of protein structure (probable backbone fragments, partial sequence - partial backbone portions) have been identified and characterized. Under analysis considerations, a few of the simplest known and easily inferable segments that favor structural deteriorations in the reconstructions are stated. Additionally, to overcome technique-specific deterrents to the characterization of biomolecules in cryogenic sample medium, the development of a protein-labeling strategy tailored to APT is suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Peripheral Stent Thrombosis Leading to Acute Limb Ischemia and Major Amputation: Incidence and Risk Factors in the Aortoiliac and Femoropopliteal Arteries

PurposeTo report the real-world incidence and risk factors of stent thrombosis in the aortoiliac and femoropopliteal arteries in case of bare nitinol stent (BNS) or covered nitinol stent (CNS) placement from a single-centre retrospective audit.Materials and MethodsMedical records of consecutive patients treated with peripheral stent placement for claudication or critical limb ischemia were audited for definite stent thrombosis defined as imaging confirmed stent thrombosis that presented as acute limb-threatening ischemia. Cases were stratified between aortoiliac and femoropopliteal anatomy. Cox regression analysis was employed to adjust for baseline clinical and procedural confounders and identify predictors of stent thrombosis and major limb loss.Results256 patients (n = 277 limbs) were analysed over a 5-year period (2009–2014) including 117 aortoiliac stents (34 CNS; 12.8 ± 5.0 cm and 83 BNS; 7.8 ± 4.0 cm) and 160 femoropopliteal ones (60 CNS; 21.1 ± 11.0 cm and 100 BNS; 17.5 ± 11.9 cm). Median follow-up was 1 year. Overall stent thrombosis rate was 6.1% (17/277) after a median of 43 days (range 2–192 days) and affected almost exclusively the femoropopliteal segment (12/60 in the CNS cohort vs. 4/100 in the BNS; p = 0.001). Annualized stent thrombosis rates (per 100 person-years) were 12.5% in case of CNS and 1.4% in case of BNS (HR 6.3, 95% CI 2.4–17.9; p = 0.0002). Corresponding major amputations rates were 8.7 and 2.5%, respectively (HR 4.5, 95% CI 2.7–27.9; p = 0.0006). On multivariable analysis, critical leg ischemia and CNS placement were the only predictors of stent thrombosis. Diabetes, critical leg ischemia, femoropopliteal anatomy, long stents and CNS were independent predictors of major amputations.ConclusionsPlacement of long femoropopliteal covered nitinol stents is associated with an increased incidence of acute stent thrombosis and ensuing major amputation. Risks are significantly lower in the aortoiliac vessels and with use of bare nitinol stents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Visualization and prediction of supercritical CO 2 distribution in sandstones during drainage: An in situ synchrotron X-ray micro-computed tomography study

Pore-scale distribution of supercritical CO 2 (scCO 2 ) exerts significant control on a variety of key hydrologic as well as geochemical processes, including residual trapping and dissolution. Despite such importance, only a small number of experiments have directly characterized the three-dimensional distribution of scCO 2 in geologic materials during the invasion (drainage) process. Here, we present a study which couples dynamic high-resolution synchrotron X-ray micro-computed tomography imaging of a scCO 2 /brine system at in situ pressure/temperature conditions with quantitative pore-scale modeling to allow direct validation of a pore-scale description of scCO2 distribution. The experiment combines high-speed synchrotron radiography with tomography to characterize the brine saturated sample, the scCO 2 breakthrough process, and the partially saturated state of a sandstone sample from the Domengine Formation, a regionally extensive unit within the Sacramento Basin (California, USA). The availability of a 3D dataset allowed us to examine correlations between grains and pores morphometric parameters and the actual distribution of scCO 2 in the sample, including the examination of the role of small-scale sedimentary structure on CO2 distribution. The segmented scCO 2 /brine volume was also used to validate a simple computational model based on the local thickness concept, able to accurately simulate the distribution of scCO 2 after drainage. The same method was also used to simulate Hg capillary pressure curves with satisfactory results when compared to the measured ones. Finally, this predictive approach, requiring only a tomographic scan of the dry sample, proved to be an effective route for studying processes related to CO 2 invasion structure in geological samples at the pore scale.

3D quantitative morphometric analysis↗

Pan-arctic river bank erosion and accretion, and planform metrics measured over intervals ranging from 1973 to 2016

This dataset provides the tabular summary of analysis of 17 reaches of 15 Arctic rivers for river bank erosion and accretion rates, as well as, river channel properties such as channel width, bank curvature, and the aspect/orientation of the river banks. These rivers include the: Chandalar River, Alaska, Colville River, Alaska; Indigirka River, Russia; Kolyma River, Russia; Koyukuk River, Alaska; Lena River, Alaska; Noatak River, Alaska; Ob River, Russia; Pechora River, Russia; Tanana River, Alaska, Selawik River, Alaska; Taz River, Russia; Yana River, Russia; Yenisei River, Russia; and the Yukon River, Alaska. The dataset was generated from a total of 129 images including: Landsat, higher resolution satellite imagery, and aerial photography over time periods ranging from the 1970s and 2016. A full list of the image dates, row and path (for Landsat), and pixel resolutions is provided in the dataset. Masks for the Chandalar River, Tanana River, and Yukon at Holy Cross were obtained from Brown et al. (2020). The masks were analyzed using the Spatially Continuous Riverbank Erosion and Accretion Measurements (SCREAM) software detailed in Rowland et al. 2016. The masks used in this analysis can be found an accompanying dataset (doi:10.15485/1571527).In files with “summary” in the name, the data is provided at a pixel level, where each mapped bank pixel has an associated erosion or accretion value, a channel width, a curvature value, and an aspect each river and time period will have an individual file. Files with “Segments” in name provide data that is averaged along segments of the rivers. These data are consolidated into a single file each for the erosion and accretion measurements. These segments are approximately 10 channel widths in length. In addition to erosion and accretion rates, the segment-based results include area measurements of erosion and accretion, islands, and channels. Revisions 2023:-Data added for the Koyukuk River for time periods of 1978-2012, 1978-2018, and 2012-2018. ---Data added from the Chandalar River, Tanana River, and Yukon River at Holy Cross based on masks obtained from Brown et al. (2020).-Updated the values for Drainage area and river slope, see methods below-Added values for meant topographic slope for upstream contributing area, long term averaged annual maximum monthly flow, average annual maximum monthly flow for the time period of erosion record, and added the river slope extracted from the Lin et al. (2020) data product.-Add field for River Planform Multi threaded (M) or Single threaded-Added ‘ConsolidatedErosionSegments.csv’ which provides the same data as AllRiversErosionSegments.csv rebinned with averages along river segments based on upstream drainage area instead of channel segments based on lengths set to approximately 10 channel widths.

54 ENVIRONMENTAL SCIENCES↗

A new Devonian euthycarcinoid reveals the use of different respiratory strategies during the marine-to-terrestrial transition in the myriapod lineage

Myriapods were, together with arachnids, the earliest animals to occupy terrestrial ecosystems, by at least the Silurian. The origin of myriapods and their land colonization have long remained puzzling until euthycarcinoids, an extinct group of aquatic arthropods considered amphibious, were shown to be stem-group myriapods, extending the lineage to the Cambrian and evidencing a marine-to-terrestrial transition. Although possible respiratory structures comparable to the air-breathing tracheal system of myriapods are visible in several euthycarcinoids, little is known about the mechanism by which they respired. Here, we describe a new euthycarcinoid from Upper Devonian alluvio-lagoonal deposits of Belgium. Synchrotron-based elemental X-ray analyses were used to extract all available information from the only known specimen. Sulfur X-ray fluorescence (XRF) mapping and spectroscopy unveil sulfate evaporation stains, spread over the entire slab, suggestive of a very shallow-water to the terrestrial environment prior to burial consistent with an amphibious lifestyle. Trace metal XRF mapping reveals a pair of ventral spherical cavities or chambers on the second post-abdominal segment that do not compare to any known feature in aquatic arthropods, but might well play a part in air-breathing. Our data provide additional support for amphibious lifestyle in euthycarcinoids and show that different respiratory strategies were used during the marine-to-terrestrial transition in the myriapod lineage.

59 BASIC BIOLOGICAL SCIENCES↗

Disentangling Rotational Dynamics and Ordering Transitions in a System of Self-Organizing Protein Nanorods via Rotationally Invariant Latent Representations

The dynamics of complex ordering systems with active rotational degrees of freedom exemplified by protein self-assembly is explored using a machine learning workflow that combines deep learning-based semantic segmentation and rotationally invariant variational autoencoder-based analysis of orientation and shape evolution. The latter allows for disentanglement of the particle orientation from other degrees of freedom and compensates for lateral shifts. The disentangled representations in the latent space encode the rich spectrum of local transitions that can now be visualized and explored via continuous variables. The time dependence of ensemble averages allows insight into the time dynamics of the system and, in particular, illustrates the presence of the potential ordering transition. Finally, analysis of the latent variables along the single-particle trajectory allows tracing these parameters on a single-particle level. The proposed approach is expected to be universally applicable for the description of the imaging data in optical, scanning probe, and electron microscopy seeking to understand the dynamics of complex systems where rotations are a significant part of the process.

representation learning↗

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Versatile Synthesis of Amine-Reactive Microgels by Self-Assembly of Azlactone-Containing Block Copolymers

Relations between molecular design, chemical functionality, and stimulus-triggered response are important for a variety of applications of polymeric systems. In this paper, reactive amphiphilic block copolymers (BCPs) of poly(2-vinylpyridine)-block-poly(2-vinyl-4,4-dimethylazlactone) (PVP-b-PVDMA) were synthesized and assembled into microgels capable of incorporating functional amines. The composition of the PVP-b-PVDMA BCPs was varied to control the number of reactive sites in the spherical aggregates created by self-assembly of PVP-b-PVDMA BCPs in a 2-propanol/THF (v:v = 19:1) solvent mixture, which is selective for PVP. PVDMA and PVP segments were selectively cross-linked by 1,4-diaminobutane (DAB) or 1,4-diiodobutane (DIB) to fabricate core- and corona-cross-linked azlactone-containing microgels, respectively. Non-cross-linked aggregates of PVP-b-PVDMA and DIB-cross-linked microgels dissociate when exposed to THF, which is a good solvent for both blocks. However, the DAB-cross-linked BCP microgels swell in THF, suggesting the formation of a stable, three-dimensional network structure. Finally, because of their ability to be reactively modified in ways that allows their stability or disassembly characteristics to be tailored, these azlactone-containing BCP microgels provide an attractive platform for applications in a wide range of fields, including catalysis, imaging, molecule separation, and guest loading for targeted delivery.

36 MATERIALS SCIENCE↗

COMBINED MULTIPOINT REMOTE AND IN SITU OBSERVATIONS OF THE ASYMMETRIC EVOLUTION OF A FAST SOLAR CORONAL MASS EJECTION

We present an analysis of the fast coronal mass ejection (CME) of 2012 March 7, which was imaged by both STEREO spacecraft and observed in situ by MESSENGER, Venus Express, Wind, and Mars Express. Based on detected arrivals at four different positions in interplanetary space, it was possible to strongly constrain the kinematics and the shape of the ejection. Using the white-light heliospheric imagery from STEREO-A and B, we derived two different kinematical profiles for the CME by applying the novel constrained self-similar expansion method. In addition, we used a drag-based model to investigate the influence of the ambient solar wind on the CME's propagation. We found that two preceding CMEs heading in different directions disturbed the overall shape of the CME and influenced its propagation behavior. While the Venus-directed segment underwent a gradual deceleration (from ∼2700 km s{sup –1} at 15 R {sub ☉} to ∼1500 km s{sup –1} at 154 R {sub ☉}), the Earth-directed part showed an abrupt retardation below 35 R {sub ☉} (from ∼1700 to ∼900 km s{sup –1}). After that, it was propagating with a quasi-constant speed in the wake of a preceding event. Our results highlight the importance of studies concerning the unequal evolution of CMEs. Forecasting can only be improved if conditions in the solar wind are properly taken into account and if attention is also paid to large events preceding the one being studied.

79 ASTRONOMY AND ASTROPHYSICS↗