Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

HOW THE LEED VENTILATION CREDIT IMPACTS ENERGY CONSUMPTION OF GSHP SYSTEMS A CASE STUDY FOR PRIMARY SCHOOLS

This paper presents a study on the impacts of increased outdoor air (OA) ventilation on the performance of ground-source heat pump (GSHP) systems that heat and cool typical primary schools. Four locations Phoenix, Miami, Seattle, and Chicago are selected in this study to represent different climate zones in the United States. eQUEST, an integrated building and HVAC system energy analysis program, is used to simulate a typical primary school and the GSHP system at the four locations with minimum and 30% more than minimum OA ventilation. The simulation results show that, without an energy recovery ventilator, the 30% more OA ventilation results in an 8.0 13.3% increase in total GSHP system energy consumption at the four locations. The peak heating and cooling loads increase by 20.2 30% and 14.9 18.4%, respectively, at the four locations. The load imbalance of the ground heat exchanger is increased in hot climates but reduced in mild and cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A historical perspective of the YF-12A thermal loads and structures program

Around 1970, the Y-F-12A loads and structures efforts focused on numerous technological issues that needed defining with regard to aircraft that incorporate hot structures in the design. Laboratory structural heating test technology with infrared systems was largely created during this program. The program demonstrated the ability to duplicate the complex flight temperatures of an advanced supersonic airplane in a ground-based laboratory. The ability to heat and load an advanced operational aircraft in a laboratory at high temperatures and return it to flight status without adverse effects was demonstrated. The technology associated with measuring loads with strain gages on a hot structure was demonstrated with a thermal calibration concept. The results demonstrated that the thermal stresses were significant although the airplane was designed to reduce thermal stresses. Considerable modeling detail was required to predict the heat transfer and the corresponding structural characteristics. The overall YF-12A research effort was particularly productive, and a great deal of flight, laboratory, test and computational data were produced and cross-correlated.

Jenkins, Jerald M.↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. In this work, the load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. The load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic and environmental impacts of a non-traditional combined heat and power system for a discrete manufacturing facility

Combined heat and power (CHP) is an electricity generation strategy that benefits all sides with a vested interest in the nations’ energy future. The technology allows for the efficient production of electricity and heat, which in turn reduces the carbon footprint and energy costs of a facility with significant heat and electricity loads. This paper investigates, through a detailed dynamic simulation, how a highly non-traditional CHP facility can leverage those forces to economically and environmentally benefit. Four system configurations of a composites manufacturing facility, one existing and three proposed systems, including two CHP configurations and one combined cooling, heating, and power (CCHP) configuration are evaluated from both economic and environmental views. The three proposed configurations are based on a 600 kW microturbine as the primary mover. The dynamic model showed great potential to capture the dynamics of the system configurations including the dynamics of temperature, oven exhaust fraction, electrical efficiency, and overall efficiency of the system configurations. All 3 CHP systems have a payback period between 8.03 and 8.33 years. The proposed system configurations reduce up to 22.7% of the CO 2 emission compared to the existing facility, supplying the demands in a cleaner manner.

42 ENGINEERING↗

Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase-Change Heat-Storage Module

Heat-storage module accommodates momentary heating or cooling overload in pumped-liquid heat-transfer system. Large heat-storage capacity of module provided by heat of fusion of material that freezes at or near temperature desired to maintain object to be heated or cooled. Module involves relatively small penalties in weight, cost, and size and more than compensates by enabling design of rest of system to handle only average load. Latent heat of fusion of phase-change material provides large heat-storage capacity in small volume.

Mulligan, James C.↗

U.S. Building Stock Characterization Study: A National Typology for Decarbonizing U.S. Buildings

To support the U.S. Department of Energy's (DOE's) Advanced Building Construction (ABC) Collaborative, the National Renewable Energy Laboratory (NREL) has been tasked with characterizing the U.S. building stock and developing a national typology of buildings. The potential use cases of such a typology are flexible and evolving, but in this initial phase, the primary intention is to help identify technology requirements and engineering solutions for moving the U.S. building stock toward a zero-carbon future by mid-century. This typology will also support the development of appropriate ABC research goals for existing buildings, such as cost targets for new technology development, and in a later phase, the typology can be used to support the implementation of ABC solutions by informing market aggregation and business model development. The ABC Initiative invests in new technologies that enable high building performance, can be deployed quickly with minimal onsite construction time, and are affordable and appealing to building owners, investors, and occupants. Funding awardees use many innovations, including new building materials, 3D printing, offsite manufacturing, robotics, and digital art-to-part. Although the goals of ABC cover a broad range of objectives around energy, comfort, and health, the primary ABC-related application of this national building characterization study is the development of retrofit packages that can be applied to reduce thermal loads in buildings. Retrofit packages will be determined collaboratively by the DOE and the ABC Collaborative. We anticipate a range of upgrade measures covering envelope-, HVAC-, and water-heating-related loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermochromic Halide Perovskite Windows with Ideal Transition Temperatures

Abstract Urban centers across the globe are responsible for a significant fraction of energy consumption and CO 2 emission. As urban centers continue to grow, the popularity of glass as cladding material in urban buildings is an alarming trend. Dynamic windows reduce heating and cooling loads in buildings by passive heating in cold seasons and mitigating solar heat gain in hot seasons. Here, reduced energy consumption in highly glazed buildings in a mesoscopic building energy model is demonstrated when thermochromic windows are employed. Savings are realized across eight disparate climate zones of the United States. The model is used to determine ideal critical transition temperatures of 20–27.5 °C for thermochromic windows based on metal halide perovskite materials. Ideal transition temperatures are realized experimentally in composite metal halide perovskite films composed of perovskite crystals and an adjacent reservoir phase. The transition temperature is controlled by cointercalating methanol, instead of water, with methylammonium iodide and tailoring the hydrogen‐bonding chemistry of the reservoir phase. Thermochromic windows based on metal halide perovskites represent a clear opportunity to mitigate the effects of energy‐hungry buildings.

14 SOLAR ENERGY↗

Novel Applications of Focused Ion Beam Technique for Planetary Sample Analyses

We are using innovative FIB techniques to prepare samples of planetary materials for different types of coordinated analyses using ion microprobes, synchrotron beamlines, and specialized transmission electron microscopy (TEM) techniques. In these cases, the FIB sample preparation is the critical step in enabling these specialized analyses. We discuss several examples below utilizing the FEI Quanta3D instrument at the NASA Johnson Space Center. Trace element analyses utilizing synchrotron x-ray fluorescence. The trace element content of mineral grains in comet dust provides important clues on their formation and processing in the early solar system. We preformed coordinated analyses of a comet dust particle that had been prepared using ultramicrotomy for TEM analysis. Following the TEM analyses, we extracted a 70 nm thick section from a region of the carbon (C) film of the TEM grid, for additional analyses. A carbon ring ~2-3 μm thick was deposited on top of the C film using the FIB. The C film on the outer rim of the ring was milled away using various patterns to uniformly release the stresses on the film, preventing rupture and collapse, and was attached to the micromanipulator needle. We then isolated the ring completely and transferred the section to a silicon sample holder for analysis using the HXN (hard X-ray nanoprobe) beamline at NSLSII at Brookhaven National Lab. Coordinated Analyses of Presolar Grains. Rare sub-m presolar grains that originate in evolved stars and supernovae, occur in primitive astromaterials and are identified by their exotic isotopic compositions. Coordinated analyses of these grains using NanoSIMS, TEM, and other techniques on the same grain is enabled by innovative FIB sample preparation. In order to obtain subsequent isotopic analyses of Mg and Fe, contributions from surrounding grains were minimized. We precisely deposited a protective cap of Pt on top of the grain to preserve the grain of interest and then milled away about 5 μm diameter of the surrounding material. Following the isotopic analyses, the spindle was extracted and thinned to electron transparency for TEM microstructural analyses. In situ heating TEM experiments on lunar samples. We extracted a FIB thin section from Apollo 17 lunar rock 76015. To avoid ion-beam damage, e-beam deposition was used to deposit the first 500 nm of the C strap, followed by ion beam-assisted deposition of ~3 μm carbon. We performed an ex situ lift-out of the section and placed the section on one of the elements of a microelectromechanical systems (MEMS) - specialized heating substrate and attached the section to the substrate by depositing small C straps with the FIB. The heating chips utilize silicon nitride windows to support the samples and provide uniform heating while enabling TEM imaging. The heating chip was loaded into a Hitachi “Blaze” heating holder and analyzed using a Hitachi HF5000 at the University of Arizona.

Rahman, Z.↗

Fatigue-Testing Apparatus for Metal Matrix Composites

Thermal and mechanical load cycling simulated in realistic fatigue tests. Efficient joining of metal matrix composite components to supporting structures is major concern facing users of these materials. Lewis Research Center designed and developed two thermal/mechancical fatigue test facilities, one to test metal matrix composite specimens and another to test compostite/metal attachment bond joints. Thermal/mechanical fatigue facility designed for testing metal matrix composites permits specimen-temperature excursions with controlled heating and loading rates. Second facility designed to test composite/metal attachment bond joints and to permit heating to maximum temperature of 1,400oC (760oC) within 10 min and cooling to 300oF (150oC) within 3 min. Facility has unique capabilities not found in other laboratories.

Westfall, Leonard J.↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyses to Verify and Improve the Accuracy of the Manufactured Home Energy Audit (MHEA)

A series of analyses were performed to determine the reasons that the Manufactured Home Energy Audit (MHEA) over predicted space-heating energy savings as measured in a recent field test and to develop appropriate corrections to improve its performance. The study used the Home Energy Rating System (HERS) Building Energy Simulation Test (BESTEST) to verify that MHEA accurately calculates the UA-values of mobile home envelope components and space-heating energy loads as compared with other, well-accepted hourly energy simulation programs. The study also used the Procedures for Verification of RESNET Accredited HERS Software Tools to determine that MHEA accurately calculates space-heating energy consumptions for gas furnaces, heat pumps, and electric-resistance furnaces. Even though MHEA's calculations were shown to be correct from an engineering point of view, three modifications to MHEA's algorithms and use of a 0.6 correction factor were incorporated into MHEA to true-up its predicted savings to values measured in a recent field test. A simulated use of the revised version of MHEA in a weatherization program revealed that MHEA would likely still recommend a significant number of cost-effective weatherization measures in mobile homes (including ceiling, floor, and even wall insulation and far fewer storm windows). Based on the findings from this study, it was recommended that a revised version of MHEA with all the changes and modifications outlined in this report should be finalized and made available to the weatherization community as soon as possible, preferably in time for use within the 2009 Program Year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Planetary Geophysics and Tectonics

Research supported by grant NAGW-1928 has addressed a variety of problems related to planetary evolution. One important focus has been on questions related to the role of chemical buoyancy in planetary evolution with application to both Venus and the Moon. We have developed a model for the evolution of the Moon (Hess and Parmentier, 1995) in which dense, highly radioactive, late stage magma ocean cumulates sink forming a core. This core heats the overlying, chemically layered mantle giving rise to a heated, chemically well-mixed layer that thickens with time. This Mixed layer eventually becomes hot enough and thick enough that its top begins to melt at a pressure low enough that melt is buoyant, thus creating mare basalts from a high pressure source of the correct composition and at an appropriate time in lunar evolution. In work completed during the last year, numerical experiments on convection in a chemically stably stratified fluid layer heated from below have been completed. These results show us how to calculate the evolution of a mixed layer in the Moon, depending on the heat production in the ilmenite- cumulate core and the chemical stratification of the overlying mantle. Chemical stratification of the mantle after its initial differentiation is would trap heat in the deep interior and prevent the rapid rise of plumes with accompanying volcanism. This trapping of heat in the interior can explain the thickness of the lunar lithosphere as a function of time as well as the magmatic evolution. We show that heat transported to the base of the lithosphere at a rate determined by current estimates of radioactivity in the Moon would not satisfy constraints on elastic lithosphere thickness from tectonic feature associated with basin loading. Trapping heat at depth by a chemically stratified mantle may also explain the absence of global compressional features on the surface that previous models predict for an initially hot lunar interior. For Venus, we developed a model in which the chemical buoyancy of crust and a depleted mantle layer stabilizes the lithosphere for long periods of time and provides a mechanism of episodic planetary evolution (Parmentier and Hess, 1992). Continued thickening of a residual depleted mantle layer eventually suppresses pressure release melting and the creation of depleted mantle. Continued cooling then allows the lithosphere to become heavier than the underlying hotter, undepleted mantle. This repeated instability can occur on time scales appropriate for episodic global resurfacing on Venus. We have also examined the role of the gabbro-eclogite phase transformation on crust and lithosphere stability and as a mechanism of crustal recycling in the absence of plate tectonics. Our work thus far concentrates on the scale of instability that would occur due to cooling or crustal thickening associated with horizontal shortening. Whether repeated overturn can explain the evolution of Venus depends in part on whether sufficient heat transfer can occur between overturns and on constraints provided by understanding observed surface features and evolution.

Parmentier, E. M.↗

Modeling the effect of laser heating on the strength and failure of 7075-T6 aluminum

The effect of rapid laser heating on the response of 7075-T6 aluminum has been characterized using 3-D digital image correlation and a series of thermocouples. The experimental results indicate that as the samples are held under a constant load, the heating from the laser profile causes non-uniform temperature and strain fields, and the strain-rate increases dramatically as the sample nears failure. Simulations have been conducted using the LLNL multi-physics code ALE3D, and compared to the experiments. The strength and failure of the material was modeled using the Johnson–Cook strength and damage models. Here, in order to capture the response, a dual-condition criterion was utilized which calibrated one set of parameters to low temperature quasi-static strain rate data, while the other parameter set is calibrated to high temperature high strain rate data. The thermal effects were captured using temperature dependent thermal constants and invoking thermal transport with conduction, convection, and thermal radiation.

36 MATERIALS SCIENCE↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Results for the Aboveground Configuration of the Boiling Water Reactor Dry Cask Simulator

The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full-sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask, in part by increasing the efficiency of internal conduction pathways, and also by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above- and below-ground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of above-ground and below-ground canistered dry cask systems. The purpose of the current investigation was to produce data sets that can be used to test the validity of the assumptions associated with the calculations used to determine steady-state cladding temperatures in modern dry casks that utilize elevated helium pressure in the sealed canister in an above-ground configuration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗