Deriving Simulation Parameters From Rating Data for Stratified Storage Tank Water Heaters
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
This paper describes the integrated energy optimization process for buildings and building clusters and demonstrates this process for new construction projects and building retrofits. An explanation is given of how mission critical building loads affect possible site and source energy use reduction in Army buildings.
This article discusses the new offerings of residential air conditioning systems with very high Seasonal Energy Efficiency Ratio (SEER) ratings, the two regional areas dictating operations standards ("hot, humid" and "hot, dry"), and the potential energy savings these new systems can provide. The article concludes with a brief review of current market potential.
In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.
A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low-grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling-up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.
Plug and process load power requirements are frequently overestimated because designers often use estimates based on 'nameplate' data, or design assumptions are high because information is not available. This generally results in oversized heating, ventilation, and air-conditioning systems; increased initial construction costs; and increased energy use caused by inefficiencies at low, part-load operation. Rightsizing of chillers in two buildings reduced whole-building energy use by 3%-4%. If an integrated design approach could enable 3% whole-building energy savings in all U.S. office buildings stock, it could save 34 TBtu of site energy per year.
A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction.This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The combined space and water heating systems (combi) uses a high efficiency direct vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that utilizing condensing water heaters or boilers with hydronic air handlers can provide both space and water heating with efficiencies of 90% or greater. Improved controls have the potential to reduce some of this complexity and boost the measured performance.
Explore the source record for details and available documents.
?Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.
This brochure details the energy efficient and sustainable aspects of the LEED Platinum-designed SunChips Business Incubator in Greensburg, Kansas.
This document showcases the LEED-Platinum designed Greensburg City Hall, which was rebuilt green, after a massive tornado destroyed Greensburg, Kansas in May 2007.