Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Synchrotron micro-X-ray fluorescence analysis of natural diamonds: First steps in identification of mineral inclusions in situ

Diamond inclusions are of particular research interest in mantle petrology and diamond exploration as they provide direct information about the chemical composition of upper and lower mantle and about the petrogenetic sources of diamonds in a given deposit. The objective of the present work is to develop semi-quantitative analytical tools for non-destructive in situ identification and characterization of mineral inclusions in diamonds using synchrotron micro-X-ray Fluorescence ({mu}SXRF) spectroscopy and micro-X-ray Absorption Near Edge Structure ({mu}XANES) spectroscopy at a focused spot size of 4 to 5 micrometers. The data were collected at the Pacific Northwest Consortium (PNC-CAT) 20-ID microprobe beamline at the Advanced Photon Source, located at the Argonne National Laboratory, and yielded the first high-resolution maps of Ti, Cr, Fe, Ni, Cu, and Zn for natural diamond grains, along with quantitative {mu}SXRF analysis of select chemical elements in exposed kimberlite indicator mineral grains. The distribution of diamond inclusions inside the natural diamond host, both visible and invisible using optical transmitted-light microscopy, can be mapped using synchrotron {mu}XRF analysis. Overall, the relative abundances of chemical elements determined by {mu}SXRF elemental analyses are broadly similar to their expected ratios in the mineral and therefore can be used to identify inclusions in diamonds in situ. Synchrotron {mu}XRF quantitative analysis provides accurate estimates of Cr contents of exposed polished minerals when calibrated using the concentration of Fe as a standard. Corresponding Cr K-edge {mu}XANES analyses on selected inclusions yield unique information regarding the formal oxidation state and local coordination of Cr.

43 PARTICLE ACCELERATORS↗

Atomic Force Microscopy, Electron Paramagnetic Resonance and X-ray Fluorescence Investigations of Self-Assembled Lines from Colloidal Solutions of Lamella MnOx

In this article, we report AFM, EPR, and X-ray fluorescence studies of well-ordered linear patterns of manganese oxide deposited onto glass and quartz surfaces. The patterns reported here were generated from newly described colloidal solutions of manganese oxide nanoparticles of composition [N(CH{sub 3}){sub 4}]{sup +}{sub 0.93}Mn{sup 4+}{sub 2.1}Mn{sup 3+}{sub 1.9}O{sub 7}(OH){sub 1.03} {center_dot} 5H{sub 2}O. Qualitative studies, and quantitative analysis of the concentration dependence of the width, frequency, and height of the ordered lines of MnO{sub x} (average Mn oxidation state of 3.52) were performed. These results provide information about the morphology of the patterns, the distribution of Mn within the lines, and the nature of free-radicals detected in this material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases

We have performed a measurement of the absolute yield of fluorescence photons at the Fermilab Test Beam. A systematic uncertainty at 5% level was achieved by the use of Cherenkov radiation as a reference calibration light source. A cross-check was performed by an independent calibration using a laser light source. A significant improvement on the energy scale uncertainty of Ultra-High Energy Cosmic Rays is expected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Raman Spectroscopy of Lithium Hydride Corrosion: Selection of an Appropriate Excitation Wavelength to Minimize Fluorescence

The recent interest in a hydrogen-based fuel economy has renewed research into metal hydride chemistry. Many of these compounds react readily with water to release hydrogen gas and form a caustic. Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFT) has been used to study the hydrolysis reaction. The LiOH stretch appears at 3670 cm{sup -1}. Raman spectroscopy is a complementary technique that employs monochromatic excitation (laser) allowing access to the low energy region of the vibrational spectrum (<600 cm{sup -1}). Weak scattering and fluorescence typically prevent Raman from being used for many compounds. The role of Li{sub 2}O in the moisture reaction has not been fully studied for LiH. Li{sub 2}O can be observed by Raman while being hidden in the Infrared spectrum.

08 HYDROGEN↗

Two-dimensional mapping of electron densities and temperatures using laser-collision induced fluorescence.

We discuss the application of the laser-collision induced fluorescence technique to produce two-dimensional maps of both electron densities and electron temperatures in a helium plasma. A collisional-radiative model is used to describe the evolution of electronic states after laser excitation. We discuss generalizations to the time dependant results that are used to simplify data acquisition and analysis. Calibration of the predictions made by the model is achieved using an cw rf discharge that is periodically perturbed via a high voltage pulse. We then demonstrate the capability of the technique by producing images of electron density and temperature of the sheath region formed around a biased electrode.

99 GENERAL AND MISCELLANEOUS↗

Monochromatic wavelength dispersive x-ray fluorescence providing sensitive and selective detection of uranium

Monochromatic wavelength dispersive X-ray fluorescence (MWDXRF) is a sensitive and selective method for elemental compositional analyses. The basis for this instrumental advance is the doubly curved crystal (DCC) optic. Previous work has demonstrated the feasibility of sensitive trace element detection for yttrium as a surrogate for curium in aqueous solutions. Additional measurements have demonstrated similar sensitivity in several different matrix environments which attests to the selectivity of the DCC optic as well as the capabilities of the MWDXRF concept. The objective of this effort is to develop an improved Pu characterization method for nuclear fuel reprocessing plants. The MWDXRF prototype instrument is the second step in a multi-year effort to achieve an improved Pu assay. This work will describe a prototype MWDXRF instrument designed for uranium detection and characterization. The prototype consists of an X-ray tube with a rhodium anode and a DCC excitation optic incorporated into the source. The DCC optic passes the RhK{alpha} line at 20.214 keV for monochromatic excitation of the sample. The source is capable of 50 W power at 50 kV and 1.0 mA operation. The x-ray emission from the sample is collected by a DCC optic set at the UL{alpha} line of 13.613 keV. The collection optic transmits the UL{alpha} x-rays to the silicon drift detector. The x-ray source, sample, collection optic and detector are all mounted on motion controlled stages for the critical alignment of these components. The sensitivity and selectivity of the instrument is obtained through the monochromatic excitation and the monochromatic detection. The prototype instrument performance has a demonstrated for sensitivity for uranium detection of around 2 ppm at the current state of development. Further improvement in sensitivity is expected with more detailed alignment.

47 OTHER INSTRUMENTATION↗

3D Fluorescent and Reflective Imaging of Whole Stardust Tracks in Aerogel

The NASA Stardust mission returned to earth in 2006 with the cometary collector having captured over 1,000 particles in an aerogel medium at a relative velocity of 6.1 km/s. Particles captured in aerogel were heated, disaggregated and dispersed along 'tracks' or cavities in aerogel, singular tracks representing a history of one capture event. It has been our focus to chemically and morphologically characterize whole tracks in 3-dimensions, utilizing solely non-destructive methods. To this end, we have used a variety of methods: 3D Laser Scanning Confocal Microscopy (LSCM), synchrotron X-ray fluorescence (SXRF), and synchrotron X-ray diffraction (SXRD). In the past months we have developed two new techniques to aid in data collection. (1) We have received a new confocal microscope which has enabled autofluorescent and spectral imaging of aerogel samples. (2) We have developed a stereo-SXRF technique to chemically identify large grains in SXRF maps in 3-space. The addition of both of these methods to our analytic abilities provides a greater understanding of the mechanisms and results of track formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility of x ray fluorescence for spent fuel safeguards

Quantifying the Pu content in spent nuclear fuel is necessary for many reasons, in particular to verify that diversion or other illicit activities have not occurred. Therefore, safeguarding the world's nuclear fuel is paramount to responsible nuclear regulation and public acceptance, but achieving this goal presents many difficulties from both a technical and economic perspective. The Next Generation Safeguards Initiative (NGSI) of NA-24 is funding a large collaborative effort between multiple laboratories and universities to improve spent nuclear fuel safeguards methods and equipment. This effort involves the current work of modeling several different nondestructive assay (NDA) techniques. Several are being researched, because no single NDA technique, in isolation, has the potential to properly characterize fuel assemblies and offer a robust safeguards measure. The insights gained from this research, will be used to down-select from the original set a few of the most promising techniques that complement each other. The goal is to integrate the selected instruments to create an accurate measurement system for fuel verification that is also robust enough to detect diversions. These instruments will be fabricated and tested under realistic conditions. This work examines one of the NDA techniques; the feasibility of using x ray emission peaks from Pu and U to gather information about their relative quantities in the spent fuel. X Ray Fluorescence (XRF), is unique compared to the investigated techniques in that it is the only one able to give the elemental ratio of Pu to U, allowing the possibility of a Pu gram quantity for the assembly to be calculated. XRF also presents many challenges, mainly its low penetration, since the low energy x rays of interest are effectively shielded by the first few millimeters of a fuel pin. This paper will explore the results of Monte Carlo N-Particle eXtended (MCNPX) transport code calculations of spent fuel x ray peaks. The MCNPX simulations will be benchmarked against measurements taken at Oak Ridge. Analysis of the feasibility of XRFs role in spent nuclear fuel safeguards efforts, particularly in the context of the overall NGSI effort will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase-resolved x-ray ferromagnetic resonance measurements in fluorescence yield

Phase-resolved x-ray ferromagnetic resonance (XFMR) has been measured in fluorescence yield, extending the application of XFMR to opaque samples on opaque substrates. Magnetization dynamics were excited in a Co{sub 50}Fe{sub 50}(0.7)/Ni{sub 90}Fe{sub 10}(5) bilayer by means of a continuous wave microwave excitation, while x-ray magnetic circular dichroism (XMCD) spectra were measured stroboscopically at different points in the precession cycle. By tuning the x-ray energy to the L{sub 3} edges of Ni and Fe, the dependence of the real and imaginary components of the element specific magnetic susceptibility on the strength of an externally applied static bias field was determined. First results from measurements on a Co{sub 50}Fe{sub 50}(0.7)/Ni{sub 90}Fe{sub 10}(5)/Dy(1) sample confirm that enhanced damping results from the addition of the Dy cap.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Best Practices for Upgrading Fluorescent Troffers to LED

This fact sheet provides guidance on the various factors to consider when deciding on an LED upgrade for a fluorescent system, such as installation costs, operating costs, desired lighting levels, and performance criteria.

lighting, LED, troffer, retrofit, fluorescent, lum↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

Preparation and up-conversion fluorescence of rare earth (Er{sup 3+} or Yb{sup 3+}/Er{sup 3+})-doped TiO{sub 2} nanobelts

Anatase TiO{sub 2} nanobelts doped with rare earth (RE) ions Yb{sup 3+}, Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} have been prepared using layered titanate nanobelts (LTO NBs) with RE ions as the precursor obtained by ion-exchange between LTO NBs and RE ions under hydrothermal process. Various measurement results demonstrate that the RE ions have doped into the lattice of TiO{sub 2}, and the Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} doped nanobelts show strong visible up-conversion (UC) fluorescence under 980 nm excitation. The UC emission intensity of LTO NBs embedded with Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} is slightly higher than that of the corresponding TiO{sub 2} nanobelts doped with RE ions, whereas higher RE doping content leads to the decrease of UC emission intensity due to the concentration-quenching effect. - Graphical abstract: Anatase TiO{sub 2} nanobelts doped with Er{sup 3+} or Yb{sup 3+}/Er{sup 3+} cations were simply synthesized using two-step preparation proceedings of ion-exchange and hydrothermal treatment, and their upconversion emissions were also investigated. SEM images of TiO{sub 2} nanobelts (NBs) doped with Er{sup 3+} (the left) and codoped with Yb{sup 3+}/Er{sup 3+} (the right).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Modified diglycol-amides for actinide separation: solvent extraction and time-resolved laser fluorescence spectroscopy complexation studies

In this work, the back-bone of the diglycolamide-structure of the TODGA extractant was modified by adding one or two methyl groups to the central methylene carbon-atoms. The influence of these structural modifications on the extraction behavior of trivalent actinides and lanthanides and other fission products was studied in solvent extraction experiments. The addition of methyl groups to the central methylene carbon atoms leads to reduced distribution ratios, also for Sr(II). This reduced extraction efficiency for Sr(II) is beneficial for process applications, as the co-extraction of Sr(II) can be avoided, resulting in an easier process design. The use of these modified diglycol-amides in solvent extraction processes is discussed. Furthermore, the complexation of Cm(III) and Eu(III) to the ligands was studied using Time-Resolved-Laser-Fluorescence-Spectroscopy (TRLFS). The complexes were characterized by slope analysis and conditional stability constants were determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plasma/Wall interaction of an insulated material by laser-induced fluorescence diagnostic

We present Argon Ion Velocity Distribution Function (IVDF) in the vicinity of an insulated BNSiO{sub 2} ceramic and a glass plate in a non magnetized plasma by laser-induced fluorescence diagnostic. Results show the rather surprising self-consistent formation of a positive or inverse sheath in the two cases. The positive plasma potential repels ions from the insulated wall and is not explained by any sheath theory. Electron secondary emission of the ceramic can be a good candidate to explain these results. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Resonance Fluorescence Measurements of High Explosives

Pacific Northwest National Laboratory and Passport Systems have collaborated to perform Nuclear Resonance Fluorescence experiments using several high quality high-explosive simulant samples. These measurements were conducted to determine the feasibility of finding and characterizing high explosive material by NRF interrogation. Electron beams of 5.1, 5.3, 8, and 10 MeV were used to produce bremsstrahlung photon beams, which irradiated the samples. The gamma-ray spectra were collected using high-purity germanium detectors. Nitrogen-to-carbon ratios of the high-explosive simulants were extracted from the 5.1 and 5.3 MeV data and compare favorably with accepted values. Analysis of the 8 and 10 MeV data is in progress; preliminary isotopic comparisons within the samples are consistent with the expected results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Nuclear Resonance Fluorescence in Geant4

Abstract– Ongoing research at Pacific Northwest National Laboratory (PNNL) is assessing the utility of exploiting nuclear resonance fluorescence (NRF) to detect bulk samples of special nuclear materials, high explosives, and related illicit cargo constituents in a variety of cargo inspection scenarios. PNNL has developed a Monte Carlo radiation transport simulation capability for studying the NRF signal response in order to facilitate computational studies of these inspection scenarios. The simulation framework implements NRF as a new physics process, “G4NRF,” in the Geant4 modeling toolkit, and leverages the Evaluated Nuclear Structure Data File (ENSDF) database of nuclear level properties to determine isotope-specific parameters of the NRF response model in general cargo constituents. The G4NRF package has been benchmarked against bremsstrahlung photon-beam data collected at the University of California at Santa Barbara’s 5.3 MeV accelerator. A series of cargo-inspection scenario studies utilizing the NRF simulation package is currently in progress.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature-dependent fluorescence decay lifetimes of the phosphor Y3(Al0.5Ga0.5)5O12:Ce 1%

The decay time of the phosphor YAG:Ce is temperature dependent. Selective incorporation of gallium into the YAG:Ce matrix permits tuning the temperature at which quenching begins. Also, the size of the phosphor particle and processing method affect this characteristic. We describe one such situation in which quenching of the combustion synthesized nanophosphor Y3(Al0.5Ga0.5)5O12:Ce 1% was observed from ambient to 125 C. By signal averaging of laser excited fluorescence, temperature uncertainties ranged from 0.05 to 0.15 C. The single shot temperature uncertainty at 115 C was 3 C, indicating the feasibility for transient thermometry with response rate exceeding 1 MHz.

36 MATERIALS SCIENCE↗