Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Finite Element Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Monitoring of corrosion effects in pipes with multi-mode acoustic signals

Current commercial long-range guided wave inspection and monitoring technologies for pipes usually require establishment of certain specific acoustic modes for wave propagation and use a large number of sensors in a certain geometric arrangement (for example, uniformly-spaced arrays of sensors on a collar, placed around a pipe). This paper, in contrast, presents a long-range corrosion detection method in pipes based on multi-mode guided acoustic waves, generated and received using simple, single-element sensors. In this technique, available guided wave modes in any interrogated zone of the structure are automatically down-selected by the medium, and changes in energy distribution over the selected modes are analyzed through signal processing to monitor material loss or addition. Here, to investigate the feasibility of the proposed method, we have performed both experimental and numerical simulation studies on 50.8-mm (2-in)-diameter schedule-40 carbon steel pipes. In these studies, a linear chirp signal is injected in compression mode, perpendicular to the surface of the pipe, generating multi-mode, multi-directional guided waves that travel within the pipe wall. Corrosion effects in the pipes are simulated numerically and experimentally. To reduce errors in the measurement technique due to changes in the local or global temperature of the measured media, a universal temperature compensation algorithm is introduced. The experimental results show good agreement with simulation results, indicating that the proposed multi-mode wave generation and detection in a pipe could be used for long-range detection and monitoring of corrosion effects, such as pipe wall losses or solid material deposits.

36 MATERIALS SCIENCE↗

Numerical Approximation of a Transport Equation with a Time-Dependent Dispersion Flux

The objective of this work is to discuss a more general one-dimensional diffusion equation that accounts for certain aspects such as the variation of a parameter that describes the relaxation time of the mass flux and also the presence of a potential field. The equation will have properties similar to a an hyperbolic equation or parabolic equation according to which values of the relaxation parameter or the potential field we consider. In the hyperbolic case we deal with some discontinuities. We apply a numerical scheme to solve this equation, which consists of using an inverse Laplace transform algorithm. The Laplace method is used to remove the time-dependent terms in the governing equation and boundary conditions. For a constant potential field general solutions can be determined. On the other hand for a non-constant potential field, a spatial discretisation must be considered. We will study the convergence of the numerical scheme based on the inverse of Laplace transform and present some test problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contact resonances of U-shaped atomic force microscope probes

Recent approaches used to characterize the elastic or viscoelastic properties of materials with nanoscale resolution have focused on the contact resonances of atomic force microscope (CR-AFM) probes. The experiments for these CR-AFM methods involve measurement of several contact resonances from which the resonant frequency and peak width are found. The contact resonance values are then compared with the noncontact values in order for the sample properties to be evaluated. The data analysis requires vibration models associated with the probe during contact in order for the beam response to be deconvolved from the measured spectra. To date, the majority of CR-AFM research has used rectangular probes that have a relatively simple vibration response. Recently, U-shaped AFM probes have created much interest because they allow local sample heating. However, the vibration response of these probes is much more complex such that CR-AFM is still in its infancy. In this article, a simplified analytical model of U-shaped probes is evaluated for contact resonance applications relative to a more complex finite element (FE) computational model. The tip-sample contact is modeled using three orthogonal Kelvin-Voigt elements such that the resonant frequency and peak width of each mode are functions of the contact conditions. For the purely elastic case, the frequency results of the simple model are within 8% of the FE model for the lowest six modes over a wide range of contact stiffness values. Results for the viscoelastic contact problem for which the quality factor of the lowest six modes is compared show agreement to within 13%. These results suggest that this simple model can be used effectively to evaluate CR-AFM experimental results during AFM scanning such that quantitative mapping of viscoelastic properties may be possible using U-shaped probes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FY 2016 Status Report: Documentation of All CIRFT Data including Hydride Reorientation Tests (Draft M2)

The first portion of this report provides a detailed description of fiscal year (FY) 2015 test result corrections and analysis updates based on FY 2016 updates to the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) program methodology, which is used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal conditions of transport (NCT). The CIRFT consists of a U-frame test setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages connecting to a universal testing machine. The curvature SNF rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are clamped to the side connecting plates of the U-frame and used to capture deformation of the rod. The second portion of this report provides the latest CIRFT data, including data for the hydride reorientation test. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The equivalent stress plot collapsed the data points from all of the SNF samples into a single zone. A detailed examination revealed that, at the same stress level, fatigue lives display a descending order as follows: H. B. Robinson Nuclear Power Station (HBR), LMK, and mixed uranium-plutonium oxide (MOX). Just looking at the strain, LMK fuel has a slightly longer fatigue life than HBR fuel, but the difference is subtle. The third portion of this report provides finite element analysis (FEA) dynamic deformation simulation of SNF assemblies . In a horizontal layout under NCT, the fuel assembly’s skeleton, which is formed by guide tubes and spacer grids, is the primary load bearing apparatus carrying and transferring vibration loads within an SNF assembly. These vibration loads include interaction forces between the SNF assembly and the canister basket walls. Therefore, the integrity of the guide tubes and spacer grids critically affects the vibration intensity of the fuel assembly during transport and must be considered when developing the multipurpose purpose canister (MPC) design for safe SNF transport.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MO-E-17A-12: Direct Realization of the CT Dose to Phantom: Energy to Heat Conversion in Polyethylene Using Calorimetry

Purpose: To develop a primary reference standard for absorbed dose to phantom for medical CT dosimetry. CT dosimetry relies on the implementation of the CTDI standard based on air kerma. We are taking a step toward an absorbed dose to water standard by first investigating the dose in a solid phantom. By directly measuring the heat converted from the incident radiation, the absorbed dose in the phantom at a point can be assessed with primary methods without relying on indirect conversions. Methods: The calorimeter contains two small thermistors embedded in a removable PE “core” inserted into the cylindrical HDPE phantom. A core made with polystyrene (PS) was also tested because of its purportedly negligible heat defect. Measurements were made using the two cores and with a calibrated ionization chamber in a CT beam. The air chamber values were converted to the dose to medium using appropriate stopping-power ratios from the literature, and then compared to the thermal data. Results: The PS core data yielded a dose of 1.3 times (4-run average, 3% std. dev.) higher than the converted chamber value, whereas the PE core data were inexplicably higher. The possible systematic errors include 1) excess heat from the thermistors, 2) in PE the exothermic chemical reactions, 3) uncertainties of the specific heat capacities of the materials, 4) thermal drift, and 5) theoretical conversion of chamber values. Monte Carlo simulations and finite element heat transfer calculations were performed to address some of these issues. The general validity was assessed in a 6 MV photon beam with an entirely different calibration scheme. Conclusion: This study demonstrates the feasibility but also revealed the difficulty in developing a new primary reference standard for absorbed dose to material for CT. Additional experimental and theoretical work is planned to achieve our goal.

07 ISOTOPE AND RADIATION SOURCES↗

Damage detection technique by measuring laser-based mechanical impedance

This study proposes a method for measurement of mechanical impedance using noncontact laser ultrasound. The measurement of mechanical impedance has been of great interest in nondestructive testing (NDT) or structural health monitoring (SHM) since mechanical impedance is sensitive even to small-sized structural defects. Conventional impedance measurements, however, have been based on electromechanical impedance (EMI) using contact-type piezoelectric transducers, which show deteriorated performances induced by the effects of a) Curie temperature limitations, b) electromagnetic interference (EMI), c) bonding layers and etc. This study aims to tackle the limitations of conventional EMI measurement by utilizing laser-based mechanical impedance (LMI) measurement. The LMI response, which is equivalent to a steady-state ultrasound response, is generated by shooting the pulse laser beam to the target structure, and is acquired by measuring the out-of-plane velocity using a laser vibrometer. The formation of the LMI response is observed through the thermo-mechanical finite element analysis. The feasibility of applying the LMI technique for damage detection is experimentally verified using a pipe specimen under high temperature environment.

42 ENGINEERING↗

IMEX and exact sequence discretization of the multi-fluid plasma model

Multi-fluid plasma models, where an electron fluid is modeled in addition to multiple ion and neutral species as well as the full set of Maxwell's equations, are useful for representing physics beyond the scope of classic MHD. This advantage presents challenges in appropriately dealing with electron dynamics and electromagnetic behavior characterized by the plasma and cyclotron frequencies and the speed of light. For physical systems, such as those near the MHD asymptotic regime, this requirement drastically increases runtimes for explicit time integration even though resolving fast dynamics may not be critical for accuracy. Implicit time integration methods, with efficient solvers, can help to step over fast time-scales that constrain stability, but do not strongly influence accuracy. As an extension, Implicit-explicit (IMEX) schemes provide an additional mechanism to choose which dynamics are evolved using an expensive implicit solve or resolved using a fast explicit solve. In this study, in addition to IMEX methods we also consider a physics compatible exact sequence spatial discretization. Here, this combines nodal bases (H-Grad) for fluid dynamics with a set of vector bases (H-Curl and H-Div) for Maxwell's equations. This discretization allows for multi-fluid plasma modeling without violating Gauss' laws for the electric and magnetic fields. This initial study presents a discussion of the major elements of this formulation and focuses on demonstrating accuracy in the linear wave regime and in the MHD limit for both a visco-resistive and a dispersive ideal MHD problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large Area Detection of Microstructural Defects with Multi-Mode Ultrasonic Signals

Cyclic loading or other stresses can lead to development of cracks and crack growth in mechanical structures, leading to eventual failure. While ultrasound imaging can be used for non-destructive testing of such structures, conventional ultrasound techniques are often limited by crack size, density, and areal coverage. An effective characterization of real-world, large-area structures is required at an early damage stage to prevent catastrophic failure and predict remaining life. In this study, a new nonlinear ultrasonic testing (NUT) method is proposed for large-area monitoring of practical structures with arbitrary complexity by using multiple-mode guided-wave ultrasonic signals. The proposed guided-wave NUT technique requires single-element transducers, simple electronics, and a mixed time-frequency domain signal processing. As a proof-of-concept demonstration, numerical simulations and experiments are performed on an A36 carbon steel beam assembly with previously formed microstructural defects that cause nonlinearities in ultrasonic response. The quadratic dependence of the nonlinear wave excitation on the input ultrasonic signal amplitude is shown by numerical simulations, and such a nonlinear ultrasonic response is experimentally observed in the zone with a high density of microstructural defects.

36 MATERIALS SCIENCE↗

Multiscale modeling of twinning and detwinning behavior of HCP polycrystals

A multiscale scheme is presented here to capture the twinning and detwinning mechanisms during cyclic loading of HCP polycrystals. In the current framework, the crystal plasticity finite element (CPFE) method is employed at the microstructural scale. The response of twinned regions at a material point is calculated using a novel homogenization scheme via a Taylor-type model. The homogenized behavior is then used in the CPFE to obtain the response of a polycrystal. An efficient rate-independent crystal plasticity model that has been incorporated into the open source PRISMS-Plasticity software is introduced here to capture the response of the twinned region. Accordingly, the corresponding algorithmic tangent modulus is derived. Finally, this multiscale scheme is validated against data available for the cyclic response of Mg alloy ZK60A. The results show that the multiscale model can capture the key elements of the sample response observed during the experiment.

36 MATERIALS SCIENCE↗

Effects of Constituent Properties on Performance Improvement of a Quenching and Partitioning Steel

In this paper, a two-dimensional microstructure-based finite element modeling method is adopted to investigate the effects of material parameters of the constituent phases on the macroscopic tensile behavior of Q&P steel and then to do a computational materials design approach for its performance improvement. For this purpose, a model Q&P steel is first produced and various experiments are then performed to characterize the steel. Actual microstructure-based model is generated based on the information from EBSD, SEM and nano-indentation test, and the material properties for the constituent phases are determined based on the initial constituents’ properties from HEXRD test and the subsequent calibration of model prediction to tensile test results. Influence of various material parameters of the constituents on the macroscopic behaviors is then investigated by separately adjusting them by small amount. Based on the observation on the respective influence of constituents’ material parameters, a new set of material parameters are devised, which results in better performance in ductility. The results indicate that various material parameters may need to be concurrently adjusted in a cohesive way in order to improve the performance of Q&P steel. In summary, higher austenite stability, less strength difference between the phases, higher hardening exponents of the phases are generally beneficial for the performance improvement. The information from this study can be used to devise new Q&P heat-treating parameters to produce the Q&P steels with better performance.

Advanced high strength steel↗

Meso-scale modelling of compressive fracture in concrete with irregularly shaped aggregates

This paper presents a meso-scale modelling framework to investigate the fracture process in concrete subjected to uniaxial and biaxial compression accounting for its mesostructural characteristics. 3D mesostructure of concrete consisting of coarse aggregates, mortar and interfacial transition zone between them was developed using an in-house code based on the Voronoi tessellation and splining method, which enables to generate the realistic-look aggregates with controllable structural features such as content, location, size and shape. Based on the generated 3D mesostructure, the concrete damage plasticity approach was employed to simulate the compressive fracture behaviour of concrete in terms of crack morphology and stress-strain response against the shape parameters of aggregate. Results indicate that the shape of aggregate has a negligible effect on compressive strength of concrete, which is highly associated with the random location and size distribution of aggregate. The aggregate irregularity has a significant influence on crack initiation and growth of concrete.

36 MATERIALS SCIENCE↗

A numerical-homogenization based phase-field fracture modeling of linear elastic heterogeneous porous media

Most porous media, such as geomaterials and biomaterials are highly heterogeneous in nature, and they contain large variations of microscopic pore structures, such as pore sizes, pore distribution, and pore shapes. The oscillation of microscopic structures is a substantial challenge in theoretical characterization and is usually ignored in continuous modeling. However, mechanical behavior of porous media such as deformation and failure, are essentially impacted by the microscopic heterogeneity which needs to be considered in modeling a porous media. Here, this research proposes a numerical modeling framework with a capability to investigate the effect of microscopic heterogeneity on the macroscopic fracture behavior in porous media by using a numerical homogenization technique, combined with the phase-field fracture modeling method. This numerical modeling strategy computes a homogenized elasticity tensor based on microscopic heterogeneous pore structures heterogenous porous domain by solving boundary value problems at microscopic domain. The strain energy and subsequent propagation of macroscopic fractures will be updated using homogenized stiffness information. Using this numerical scheme, the microscopic pore structure’s impact on the fracture behavior through the homogenized elastic tensor will be taken into account. This multiscale technique is benchmarked against classical problems. Finally, the results highlight the importance of the underlying pore structure and reveal that both fracture strength and propagation path can be influenced by the microscopic heterogeneity.

36 MATERIALS SCIENCE↗

Effects of Retained Austenite Stability and Volume Fraction on Deformation Behaviors of TRIP Steels

In this paper, the separate effects of austenite stability and its volume fraction on the deformation behaviors of transformation-induced plasticity (TRIP) steels are investigated based on the microstructure-based finite element modeling method. The effects of austenite stability on the strength, ductility and formability of TRIP steels are first examined based on the microstructure of a commercial TRIP 800 steel. Then, the separate effects of the austenite volume fraction on the overall deformation behaviors of TRIP steels are examined based on the various representative volume elements (RVEs). The computational results suggest that the higher austenite stability is helpful to increase the ductility and formability, but not the UTS. However, the increase of austenite volume fraction alone is not helpful in improving the performance of TRIP steels. This may indicate that various other material factors should also be concurrently adjusted during thermo-mechanical manufacturing process in a way to increase the performance of TRIP steels, which needs further investigation.

36 MATERIALS SCIENCE↗

SU-G-TeP2-05: Development of a Thimble Calorimeter for Absorbed Dose to Water Characterized in MV Photons

Purpose: To develop a thimble sized polystyrene calorimeter for use from kV to MV photons, as a primary reference standard for applications from diagnostic CT imaging to therapy beam dose determination. Methods: A polystyrene calorimeter about 1.5 cm diameter embedded with small thermistors was characterized in a 6 MV photon beam from a clinical accelerator at 5 nominal dose rates from 0.8 to 4 Gy/min. Irradiations were delivered with beam on/off cycles first at 60 s and then at 20 s. Two sets of phantom conditions were evaluated: 1) in a 30 cm diameter polyethylene cylinder, and 2) in 10 cm depth of a 30 cm water phantom. The temperature waveforms were recorded and analyzed for temperature rise, arriving at a dose to polystyrene. This value is compared with the result of measurements under identical conditions using an ionization chamber calibrated for absorbed dose to water. Monte Carlo simulations were performed on the measurement systems to estimate such a ratio. Results: The ratio of the dose determined by the calorimeter to the dose reported by the ionization chamber was aggregated from all 5 dose rates. The 60 s results show a much elevated response in both phantoms compared to their respective expected results based on simulation. This deviation was reduced when the on/off cycles were shortened to 20 s. This behavior was possibly due to the heat conduction effects in the small calorimeter body. Finite element modeling is being conducted to simulate this effect. Conclusion: A small solid plastic calorimeter offers the convenience of a portable absorbed dose standard based on direct measurement of energy deposition, but comes at the expense of heat transfer complications which need to be characterized. This work offers preliminary evidence of the behavior and quantitative assessment of the issues to be resolved in future investigations.

60 APPLIED LIFE SCIENCES↗

Predicting forming limit diagrams for magnesium alloys using crystal plasticity finite elements

The crystal plasticity finite element (CPFE) method was used to predict forming limit strains of hexagonal close-packed (HCP) polycrystalline magnesium alloy sheets, namely AZ31 and ZE10, under an isothermal temperature condition. The strain rate-dependent uniaxial tensile test data along various loading directions and an initial texture were used to determine the constitutive parameters of the crystal plasticity model. A hybrid representative volume element approach, which combines the CPFE and the Marciniak–Kuczynski model, was developed to obtain the forming limit diagram of the magnesium alloys. The predicted forming limits were in excellent agreement with the Nakazima test results. Moreover, the microscopic responses such as slip/twin activation and deformation texture changes during various loading paths from uniaxial tension to the balanced biaxial tension were comprehensively analyzed and discussed from the CPFE results to understand the underlying micro-mechanism for the macro-mechanical responses.

36 MATERIALS SCIENCE↗

Effect of Computational Schemes on Coupled Flow and Geo-Mechanical Modeling of CO 2 Leakage through a Compromised Well

Carbon capture, utilization, and storage (CCUS) describes a set of technically viable processes to separate carbon dioxide (CO 2 ) from industrial byproduct streams and inject it into deep geologic formations for long-term storage. Legacy wells located within the spatial domain of new injection and production activities represent potential pathways for fluids (i.e., CO 2 and aqueous phase) to leak through compromised components (e.g., through fractures or micro-annulus pathways). The finite element (FE) method is a well-established numerical approach to simulate the coupling between multi-phase fluid flow and solid phase deformation interactions that occur in a compromised well system. We assumed the spatial domain consists of a three-phases system: a solid, liquid, and gas phase. For flow in the two fluids phases, we considered two sets of primary variables: the first considering capillary pressure and gas pressure (PP) scheme, and the second considering liquid pressure and gas saturation (PS) scheme. Fluid phases were coupled with the solid phase using the full coupling (i.e., monolithic coupling) and iterative coupling (i.e., sequential coupling) approaches. The challenge of achieving numerical stability in the coupled formulation in heterogeneous media was addressed using the mass lumping and the upwinding techniques. Numerical results were compared with three benchmark problems to assess the performance of coupled FE solutions: 1D Terzaghi’s consolidation, Liakopoulos experiments, and the Kueper and Frind experiments. We found good agreement between our results and the three benchmark problems. For the Kueper and Frind test, the PP scheme successfully captured the observed experimental response of the non-aqueous phase infiltration, in contrast to the PS scheme. These exercises demonstrate the importance of fluid phase primary variable selection for heterogeneous porous media. We then applied the developed model to the hypothetical case of leakage along a compromised well representing a heterogeneous media. Considering the mass lumping and the upwinding techniques, both the monotonic and the sequential coupling provided identical results, but mass lumping was needed to avoid numerical instabilities in the sequential coupling. Additionally, in the monolithic coupling, the magnitude of primary variables in the coupled solution without mass lumping and the upwinding is higher, which is essential for the risk-based analyses.

deformation flow↗

Intense pulsed light annealing of copper zinc tin sulfide nanocrystal coatings

A promising method for forming the absorber layer in copper zinc tin sulfide [Cu{sub 2}ZnSnS{sub 4} (CZTS)] thin film solar cells is thermal annealing of coatings cast from dispersions of CZTS nanocrystals. Intense pulsed light (IPL) annealing utilizing xenon flash lamps is a potential high-throughput, low-cost, roll-to-roll manufacturing compatible alternative to thermal annealing in conventional furnaces. The authors studied the effects of flash energy density (3.9–11.6 J/cm{sup 2}) and number of flashes (1–400) during IPL annealing on the microstructure of CZTS nanocrystal coatings cast on molybdenum-coated soda lime glass substrates (Mo-coated SLG). The annealed coatings exhibited cracks with two distinct linear crack densities, 0.01 and 0.2 μm{sup −1}, depending on the flash intensity and total number of flashes. Low density cracking (0.01 μm{sup −1}, ∼1 crack per 100 μm) is caused by decomposition of CZTS at the Mo-coating interface. Vapor decomposition products at the interface cause blisters as they escape the coating. Residual decomposition products within the blisters were imaged using confocal Raman spectroscopy. In support of this hypothesis, replacing the Mo-coated SLG substrate with quartz eliminated blistering and low-density cracking. High density cracking is caused by rapid thermal expansion and contraction of the coating constricted on the substrate as it is heated and cooled during IPL annealing. Finite element modeling showed that CZTS coatings on low thermal diffusivity materials (i.e., SLG) underwent significant differential heating with respect to the substrate with rapid rises and falls of the coating temperature as the flash is turned on and off, possibly causing a build-up of tensile stress within the coating prompting cracking. Use of a high thermal diffusivity substrate, such as a molybdenum foil (Mo foil), reduces this differential heating and eliminates the high-density cracking. IPL annealing in presence of sulfur vapor prevented both low- and high-density cracking as well as blistering. However, grain growth was limited even after annealing with 400 flashes. This lack of grain growth is attributed to a difficulty of maintaining high sulfur vapor pressure and absence of alkali metal impurities when Mo foil substrates are used.

36 MATERIALS SCIENCE↗