Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Factor Analysis, Statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Systematics of the charged-hadron P{sub T} spectrum and the nuclear suppression factor in heavy-ion collisions from {radical}(s{sub NN})=200 GeV to {radical}(s{sub NN})=2.76 TeV

In this paper, our goal is to make a simultaneous analysis of the high- and low-P{sub T} parts of the charged-hadron P{sub T} spectrum measured by the ALICE collaboration [K. Aamodt et al. (ALICE Collaboration), Phys. Lett. B 696, 30 (2011)] in central Pb-Pb collisions at {radical}(s{sub NN})=2.76 TeV at the Large Hadron Collider (LHC), based on models which have been successfully applied and constrained in Au-Au collisions at the Relativistic Heavy Ion Collider (RHIC). For the hydrodynamical modeling with which we obtain the low-P{sub T} spectrum, we have computed the initial conditions based on perturbative QCD (pQCD) minijet production and saturation. The sensitivity of the obtained charged-hadron P{sub T} spectrum on the hydrodynamic model parameters is studied. For the high-P{sub T} part, we apply a number of parton-medium interaction models, which are tuned to describe the nuclear suppression factor R{sub AA} measured at RHIC in central Au-Au collisions at {radical}(s{sub NN})=200 GeV. We find that the higher kinematic reach of the LHC, manifest in the hardening of the pQCD parton spectral slope, is in principle very efficient in discriminating the various models. However, due to the uncertainties in the p-p baseline, none of the tested models can be firmly ruled out with the present ALICE data. Comparison with the LHC data in this approach shows that the combined hydrodynamic and pQCD + jet quenching components can reproduce the data well in the whole measured P{sub T} range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Analysis of the charmed semileptonic decay D + → ρ 0 μ + v

The search for the fundamental constituents of matter has been pursued and studied since the dawn of civilization. As early as the fourth century BCE, Democritus, expanding the teachings of Leucippus, proposed small, indivisible entities called atoms, interacting with each other to form the Universe. Democritus was convinced of this by observing the environment around him. He observed, for example, how a collection of tiny grains of sand can make out smooth beaches. Today, following the lead set by Democritus more than 2500 years ago, at the heart of particle physics is the hypothesis that everything we can observe in the Universe is made of a small number of fundamental particles interacting with each other. In contrast to Democritus, for the last hundred years we have been able to perform experiments that probe deeper and deeper into matter in the search for the fundamental particles of nature. Today's knowledge is encapsulated in the Standard Model of particle physics, a model describing the fundamental particles and their interactions. It is within this model that the work in this thesis is presented. This work attempts to add to the understanding of the Standard Model by measuring the relative branching fraction of the charmed semileptonic decay D + → ρ 0 μ + v with respect to D + → $\bar{K}$* 0 μ + v. Many theoretical models that describe hadronic interactions predict the value of this relative branching fraction, but only a handful of experiments have been able to measure it with any precision. By making a precise measurement of this relative branching fraction theorists can distinguish between viable models as well as refine existing ones. In this thesis we presented the measurement of the branching fraction ratio of the Cabibbo suppressed semileptonic decay mode D + → ρ 0 μ + v with respect to the Cabibbo favored mode D + → $\bar{K}$* 0 μ + v using data collected by the FOCUS collaboration. We used a binned maximum log-likelihood fit that included all known semileptonic backgrounds as well as combinatorial and muonmisidentification backgrounds to extract the yields for both the signal and normalization modes. We reconstructed 320 ± 44 D + → ρ 0 μ + v events and 11372 ± 161 D + → K - π + μ + v events. Taking into account the non-resonant contribution to the D + → K - π + μ + v yield due to a s-wave interference first measured by FOCUS the branching fraction ratio is: Γ(D + → ρ 0 μ + v) = 0.0412 ± 0.0057 ± 0.0040 (VII.1) where the first error is statistical and the second error is the systematic uncertainty. This represents a substantial improvement over the previous world average. More importantly, the new world average for Γ(D + → 0 μ + v)/Γ(D + →$\bar{K}$* 0 μ + v) along with the improved measurements in the electronic mode can be used to discriminate among different theoretical approaches that aim to understand the hadronic current involved in the charm to light quark decay process. The average of the electronic and muonic modes indicate that predictions for the partial decay width Γ(D + → ρ 0 ℓ + v) and the ratio Γ(D + →ρ 0 ℓ + v)/Γ(D + →$\bar{K}$* 0 ℓ + v) based on Sum Rules are too low. Using the same data used to extract Γ(D + →ρ 0 μ + v)/Γ(D + →$\bar{K}$* 0 μ + v) we studied the feasibility of measuring the form factors for the D + → ρ 0 μ + v decay. We found that the need to further reduce the combinatorial and muon misidentification backgrounds left us with a much smaller sample of 52 ± 12 D + → ρ 0 μ + μ events; not enough to make a statistically significant measurement of the form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose to 10% of the urethra cutpoint for urinary health-related quality of life was 120% of the prescription dose. Conclusion: EPIC was a more sensitive tool for detecting the effects on function and bother than were the generic toxicity scales. The urethral dose had the strongest association with a deteriorating urinary quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Graphite Characterization: Baseline Variability Analysis Report

The Idaho National INL’s Baseline Material Property program provides many measurements of different material properties on a variety of nuclear graphite grades being investigated for irradiation-induced changes in material properties. The baseline material properties provide an unirradiated reference for comparison with measurements of those properties after irradiation. This study describes how uncertainty, or variance, in estimates of important material properties, like compressive strength, may depend on sample size, sample distribution and parameter estimation methods. Compressive strength data from two large collections of specimens from a billet of PCEA graphite (sample size = 230) and a billet of IG-110 graphite (sample size = 48) are used to illustrate these dependencies. The grades of graphite used represent approximate end members in terms of relative variability in strength measurements. Monte Carlo simulation and bootstrapping methods were used to examine variance in Weibull-parameter estimates as a function of sample size. Results were consistent with what previous statistical analyses have shown about the relationship between sample size and width of the confidence interval for maximum likelihood (ML) estimated parameters when samples are repeatedly drawn from a Weibull distribution. As a function of sample size, the precision of the modulus estimate increases faster than that of the characteristic strength. The modulus maximum likelihood estimates (MLEs) are biased for low sample sizes. The American Society for Testing and Materials document ASTM D7846-16 provides equations that describe the dependence of the variance of parameter MLEs on sample size. Using the same methodology, we show that the polynomials provided for variance dependence on sample size are inaccurate for sample sizes greater than ~120. We provide approximations to that relationship that illustrate relative constancy for sample size > ~10, in the logspace relationship of the modulus variance and the log transformed characteristic strength variance. Bootstrapping provided a means of comparing Weibull parameters obtained using ASME’s guidance for specimen collection to those obtained using different weighting in a case where strength is related to position in a billet and to grain orientation and a single distribution is used to characterize the billet. ASME specifies that samples be collected with equal representation in all locations and grain orientations. Parameter values obtained using ASME’s method were different from those obtained using random sampling of the complete data sets, and this was particularly true for the PCEA data. In addition, while the ASME approach yielded more conservative parameters for the PCEA data, the opposite was true for the IG-110 data. The difference observed for the PCEA data set likely reflects the larger number of against-grain specimens collected, which had generally higher strength than the with-grain specimens. This emphasizes the importance of the dependence of strength on location or grain orientation and suggests that it may be prudent to weight specimen collection toward the weaker subgroups if a conservative estimate as desired, as the equal weighting method recommended by ASME would will not always provide the most conservative Weibull parameters. Because spatial correlations commonly exist in certain grades of graphite, future work may involve developing a methodology for parameter inference that relaxes the assumption of independent specimens. ASTM and ASME codes recommend different parameter estimation methods and models of the Weibull distribution in different situations. Descriptions of the effects on parameter estimates for the example billets used in this study provide an example of how the method may affect the parameter estimate, and how—in this case—that compares to differences due to other factors, such as sample size and dependence on grain orientation or sample location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Animal movement estimation and network-based epidemic modeling: Illustration for the swine industry in Iowa (US)

Animal movement plays a critical role in disease transmission between farms. However, in the United States, the lack of available animal shipment data, sometimes coupled with a lack of detailed information about farm demographics and characteristics, presents great challenges for epidemic modeling and prediction. In this study, we proposed a new method based on the maximum entropy to generate “synthetic” animal movement networks, considering available statistics about the premises operation type, operation size, and the distance between premises. We illustrated our method for the swine movement networks in Iowa and performed network analyses to gain insights into the swine industry. We then applied the generated networks to a network-based epidemic model to identify potential system vulnerabilities in terms of disease transmission. The model was parameterized for African Swine Fever (ASF) as the US swine industry is quite concerned about this disease. Results show that premises with a central role in the network are more vulnerable to disease outbreaks and play an important role in disease spread. Simulations with outbreaks starting from random farms reveal no significant large outbreaks, indicating the system’s relative robustness against arbitrary disease introductions. However, outbreaks originating from high out-degree farms can lead to large epidemic sizes. This underscores the importance for stakeholders and policymakers to continue improving animal movement records and traceability programs in the US and the value of making that data available to epidemiologists and modelers to better understand risk and inform strategies aimed to cost-effectively prevent and control disease transmission. Our approach could be easily adapted to estimate movement networks in other animal production systems and to inform disease spread models for various infectious diseases.

60 APPLIED LIFE SCIENCES↗

Optical–SZE scaling relations for DES optically selected clusters within the SPT-SZ Survey

We study the Sunyaev-Zel'dovich effect (SZE) signature in South Pole Telescope (SPT) data for an ensemble of 719 optically identified galaxy clusters selected from 124.6 deg$^2$ of the Dark Energy Survey (DES) science verification data, detecting a stacked SZE signal down to richness $\lambda\sim20$. The SZE signature is measured using matched-filtered maps of the 2500 deg$^2$ SPT-SZ survey at the positions of the DES clusters, and the degeneracy between SZE observable and matched-filter size is broken by adopting as priors SZE and optical mass-observable relations that are either calibrated using SPT selected clusters or through the Arnaud et al. (2010, A10) X-ray analysis. We measure the SPT signal to noise $\zeta$-$\lambda$, relation and two integrated Compton-$y$ $Y_\textrm{500}$-$\lambda$ relations for the DES-selected clusters and compare these to model expectations accounting for the SZE-optical center offset distribution. For clusters with $\lambda > 80$, the two SPT calibrated scaling relations are consistent with the measurements, while for the A10-calibrated relation the measured SZE signal is smaller by a factor of $0.61 \pm 0.12$ compared to the prediction. For clusters at $20 < \lambda < 80$, the measured SZE signal is smaller by a factor of $\sim$0.20-0.80 (between 2.3 and 10~$\sigma$ significance) compared to the prediction, with the SPT calibrated scaling relations and larger $\lambda$ clusters showing generally better agreement. We quantify the required corrections to achieve consistency, showing that there is a richness dependent bias that can be explained by some combination of contamination of the observables and biases in the estimated masses. We discuss possible physical effects, as contamination from line-of-sight projections or from point sources, larger offsets in the SZE-optical centering or larger scatter in the $\lambda$-mass relation at lower richnesses.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of V2 Antibody Responses Induced in Vaccinees in the ALVAC/AIDSVAX HIV-1 Vaccine Efficacy Trial

The RV144 clinical trial of a prime/boost immunizing regimen using recombinant canary pox (ALVAC-HIV) and two gp120 proteins (AIDSVAX B and E) was previously shown to have a 31.2% efficacy rate. Plasma specimens from vaccine and placebo recipients were used in an extensive set of assays to identify correlates of HIV-1 infection risk. Of six primary variables that were studied, only one displayed a significant inverse correlation with risk of infection: the antibody (Ab) response to a fusion protein containing the V1 and V2 regions of gp120 (gp70-V1V2). This finding prompted a thorough examination of the results generated with the complete panel of 13 assays measuring various V2 Abs in the stored plasma used in the initial pilot studies and those used in the subsequent case-control study. The studies revealed that the ALVACHIV/AIDSVAX vaccine induced V2-specific Abs that cross-react with multiple HIV-1 subgroups and recognize both conformational and linear epitopes. The conformational epitope was present on gp70-V1V2, while the predominant linear V2 epitope mapped to residues 165–178, immediately N-terminal to the putative a4b7 binding motif in the mid-loop region of V2. Odds ratios (ORs) were calculated to compare the risk of infection with data from 12 V2 assays, and in 11 of these, the ORs were #1, reaching statistical significance for two of the variables: Ab responses to gp70-V1V2 and to overlapping V2 linear peptides. It remains to be determined whether anti-V2 Ab responses were directly responsible for the reduced infection rate in RV144 and whether anti-V2 Abs will prove to be important with other candidate HIV vaccines that show efficacy, however, the results support continued dissection of Ab responses to the V2 region which may illuminate mechanisms of protection from HIV-1 infection and may facilitate the development of an effective HIV-1 vaccine.

59 BASIC BIOLOGICAL SCIENCES↗

The ALMA spectroscopic survey in the Hubble Ultra Deep Field: continuum number counts, resolved 1.2 mm extragalactic background, and properties of the faintest dusty star-forming galaxies

We present an analysis of a deep (1σ = 13 μJy) cosmological 1.2 mm continuum map based on ASPECS, the ALMA Spectroscopic Survey in the Hubble Ultra Deep Field. In the 1 arcmin{sup 2} covered by ASPECS we detect nine sources at >3.5σ significance at 1.2 mm. Our ALMA-selected sample has a median redshift of z=1.6±0.4, with only one galaxy detected at z > 2 within the survey area. This value is significantly lower than that found in millimeter samples selected at a higher flux density cutoff and similar frequencies. Most galaxies have specific star formation rates (SFRs) similar to that of main-sequence galaxies at the same epoch, and we find median values of stellar mass and SFRs of 4.0×10{sup 10} M{sub ⊙} and ∼40 M{sub ⊙} yr{sup −1}, respectively. Using the dust emission as a tracer for the interstellar medium (ISM) mass, we derive depletion times that are typically longer than 300 Myr, and we find molecular gas fractions ranging from ∼0.1 to 1.0. As noted by previous studies, these values are lower than those using CO-based ISM estimates by a factor of ∼2. The 1 mm number counts (corrected for fidelity and completeness) are in agreement with previous studies that were typically restricted to brighter sources. With our individual detections only, we recover 55% ± 4% of the extragalactic background light (EBL) at 1.2 mm measured by the Planck satellite, and we recover 80% ± 7% of this EBL if we include the bright end of the number counts and additional detections from stacking. The stacked contribution is dominated by galaxies at z∼1--2, with stellar masses of (1–3) × 10{sup 10} M {sub ⊙}. For the first time, we are able to characterize the population of galaxies that dominate the EBL at 1.2 mm.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Four Cisplatin-Based Radiochemotherapy Regimens for Nonmetastatic Stage III/IV Squamous Cell Carcinoma of the Head and Neck;Head-and-neck cancer; Cisplatin-based radiochemotherapy; Toxicity; Treatment outcomes

Purpose: To compare the outcomes of four cisplatin-based radiochemotherapy regimens in 311 patients with Stage III/IV squamous cell carcinoma of the head and neck. Methods and Materials: Concurrent chemotherapy consisted of three courses of cisplatin 100 mg/m{sup 2} on Day 1 (Group A, n = 74), two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 plus 5-fluorouracil 1,000 mg/m{sup 2} on Days 1-5 (Group B, n = 49), two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 plus 5-fluorouracil 600 mg/m{sup 2} on Days 1-5 (Group C, n = 102), or two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 (Group D, n = 86). The groups were retrospectively compared for toxicity and outcomes, and 11 additional factors were evaluated for outcomes. Results: No significant difference was observed among the groups regarding radiation-related acute oral mucositis and radiation-related late toxicities. Acute Grade 3 skin toxicity was significantly more frequent in Group B than in the patients of the other three groups (p = .013). The chemotherapy-related Grade 3 nausea/vomiting rate was 24% for Group A, 8% for Group B, 9% for Group C, and 6% for Group D (p = .003). The corresponding Grade 3 nephrotoxicity rates were 8%, 1%, 2%, and 1% (p = .019). The corresponding Grade 3-4 hematologic toxicity rates were 35%, 41%, 19%, and 21% (p = .027). Chemotherapy could be completed in 50%, 59%, 74%, and 83% of the Group A, B, C, and D patients, respectively (p = .002). Toxicity-related radiotherapy breaks occurred in 39%, 43%, 21%, and 15% of Groups A, B, C, and D, respectively (p = .005). The 3-year locoregional control rate was 67%, 72%, 60%, and 59% for Groups A, B, C, and D, respectively (p = .48). The corresponding 3-year metastasis-free survival rates were 67%, 74%, 63%, and 79% (p = .31), and the corresponding 3-year survival rates were 60%, 63%, 50%, and 71% (p = .056). On multivariate analysis, Karnofsky performance status, histologic grade, T/N category, preradiotherapy hemoglobin level, completion of chemotherapy, and radiotherapy breaks were associated with the outcome. Conclusion: The four compared radiochemotherapy regimens were not significantly different regarding treatment outcomes. Two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 were better tolerated than the other three regimens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy Endpoints of Radiation Therapy Group Protocol 0247: A Randomized, Phase 2 Study of Neoadjuvant Radiation Therapy Plus Concurrent Capecitabine and Irinotecan or Capecitabine and Oxaliplatin for Patients With Locally Advanced Rectal Cancer

Purpose: To report secondary efficacy endpoints of Radiation Therapy Oncology Group protocol 0247, primary endpoint analysis of which demonstrated that preoperative radiation therapy (RT) with capecitabine plus oxaliplatin achieved a pathologic complete remission prespecified threshold (21%) to merit further study, whereas RT with capecitabine plus irinotecan did not (10%). Methods and Materials: A randomized, phase 2 trial evaluated preoperative RT (50.4 Gy in 1.8-Gy fractions) with 2 concurrent chemotherapy regimens: (1) capecitabine (1200 mg/m{sup 2}/d Monday-Friday) plus irinotecan (50 mg/m{sup 2}/wk × 4); and (2) capecitabine (1650 mg/m{sup 2}/d Monday-Friday) plus oxaliplatin (50 mg/m{sup 2}/wk × 5) for clinical T3 or T4 rectal cancer. Surgery was performed 4 to 8 weeks after chemoradiation, then 4 to 6 weeks later, adjuvant chemotherapy (oxaliplatin 85 mg/m{sup 2}; leucovorin 400 mg/m{sup 2}; 5-fluorouracil 400 mg/m{sup 2}; 5-fluorouracil 2400 mg/m{sup 2}) every 2 weeks × 9. Disease-free survival (DFS) and overall survival (OS) were estimated univariately by the Kaplan-Meier method. Local–regional failure (LRF), distant failure (DF), and second primary failure (SP) were estimated by the cumulative incidence method. No statistical comparisons were made between arms because each was evaluated individually. Results: A total of 104 patients (median age, 57 years) were treated; characteristics were similar for both arms. Median follow-up for RT with capecitabine/irinotecan arm was 3.77 years and for RT with capecitabine/oxaliplatin arm was 3.97 years. Four-year DFS, OS, LRF, DF, and SP estimates for capecitabine/irinotecan arm were 68%, 85%, 16%, 24%, and 2%, respectively. The 4-year DFS, OS, LRF, DF, and SP failure estimates for capecitabine/oxaliplatin arm were 62%, 75%, 18%, 30%, and 6%, respectively. Conclusions: Efficacy results for both arms are similar to other reported studies but suggest that pathologic complete remission is an unsuitable surrogate for traditional survival metrics of clinical outcome. Although it remains uncertain whether the addition of a second cytotoxic agent enhances the effectiveness of fluorouracil plus RT, these results suggest that further study of irinotecan may be warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Roles of Radiation Dose and Chemotherapy in the Etiology of Stomach Cancer as a Second Malignancy

Purpose: To evaluate the roles of radiation dose, chemotherapy, and other factors in the etiology of stomach cancer in long-term survivors of testicular cancer or Hodgkin lymphoma. Methods and Materials: We conducted a cohort study in 5,142 survivors of testicular cancer or Hodgkin lymphoma treated in the Netherlands between 1965 and 1995. In a nested case-control study, detailed information on treatment, smoking, gastrointestinal diseases, and family history was collected for 42 patients with stomach cancer and 126 matched controls. For each subject, the mean radiation dose to the stomach was estimated. Relative risks (RRs) of stomach cancer and the radiation-related excess relative risk (ERR) per gray were calculated by conditional logistic regression analysis. Results: The risk of stomach cancer was 3.4-fold increased compared with the general population. The risk increased with increasing mean stomach dose (p for trend, <0.001), at an ERR of 0.84 per Gy (95% confidence interval [CI], 0.12-15.6). Mean stomach doses of more than 20 Gy were associated with a RR of 9.9 (95% CI, 3.2-31.2) compared with doses below 11 Gy. The risk was 1.8-fold (95% CI, 0.8-4.4) increased after chemotherapy and 5.4-fold (95% CI, 1.2-23.9) increased after high doses of procarbazine (>=13,000 mg) vs. <10,000 mg. The RR of smoking more than 10 cigarettes per day vs. no smoking was 1.6 (95% CI, 0.6-4.2). Conclusions: Stomach cancer risk is strongly radiation dose dependent. The role of chemotherapy, particularly of procarbazine and related agents, needs further study, because of the relatively small numbers of chemotherapy-treated subjects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Water use in the development and operation of geothermal power plants.

Geothermal energy is increasingly recognized for its potential to reduce carbon emissions and U.S. dependence on foreign oil. Energy and environmental analyses are critical to developing a robust set of geothermal energy technologies. This report summarizes what is currently known about the life cycle water requirements of geothermal electric power-generating systems and the water quality of geothermal waters. It is part of a larger effort to compare the life cycle impacts of large-scale geothermal electricity generation with other power generation technologies. The results of the life cycle analysis are summarized in a companion report, Life Cycle Analysis Results of Geothermal Systems in Comparison to Other Power Systems. This report is divided into six chapters. Chapter 1 gives the background of the project and its purpose, which is to inform power plant design and operations. Chapter 2 summarizes the geothermal electricity generation technologies evaluated in this study, which include conventional hydrothermal flash and binary systems, as well as enhanced geothermal systems (EGS) that rely on engineering a productive reservoir where heat exists but water availability or permeability may be limited. Chapter 3 describes the methods and approach to this work and identifies the four power plant scenarios evaluated: a 20-MW EGS plant, a 50-MW EGS plant, a 10-MW binary plant, and a 50-MW flash plant. The two EGS scenarios include hydraulic stimulation activities within the construction stage of the life cycle and assume binary power generation during operations. The EGS and binary scenarios are assumed to be air-cooled power plants, whereas the flash plant is assumed to rely on evaporative cooling. The well field and power plant design for the scenario were based on simulations using DOE's Geothermal Economic Technology Evaluation Model (GETEM). Chapter 4 presents the water requirements for the power plant life cycle for the scenarios evaluated. Geology, reservoir characteristics, and local climate have various effects on elements such as drilling rate, the number of production wells, and production flow rates. Over the life cycle of a geothermal power plant, from construction through 30 years of operation, plant operations is where the vast majority of water consumption occurs. Water consumption refers to the water that is withdrawn from a resource such as a river, lake, or non-geothermal aquifer that is not returned to that resource. For the EGS scenarios, plant operations consume between 0.29 and 0.72 gal/kWh. The binary plant experiences similar operational consumption, at 0.27 gal/kWh. Far less water, just 0.01 gal/kWh, is consumed during operations of the flash plant because geofluid is used for cooling and is not replaced. While the makeup water requirements are far less for a hydrothermal flash plant, the long-term sustainability of the reservoir is less certain due to estimated evaporative losses of 14.5-33% of produced geofluid at operating flash plants. For the hydrothermal flash scenario, the average loss of geofluid due to evaporation, drift, and blowdown is 2.7 gal/kWh. The construction stage requires considerably less water: 0.001 gal/kWh for both the binary and flash plant scenarios and 0.01 gal/kWh for the EGS scenarios. The additional water requirements for the EGS scenarios are caused by a combination of factors, including lower flow rates per well, which increases the total number of wells needed per plant, the assumed well depths, and the hydraulic stimulation required to engineer the reservoir. Water quality results are presented in Chapter 5. The chemical composition of geofluid has important implications for plant operations and the potential environmental impacts of geothermal energy production. An extensive dataset containing more than 53,000 geothermal geochemical data points was compiled and analyzed for general trends and statistics for typical geofluids. Geofluid composition was found to vary significantly both among and within geothermal fields. Seven main chemical constituents were found to account for 95-99% of the dissolved solids in typical geofluids. In order of abundance, they were chloride, sodium, bicarbonate, sulfate, silica, calcium, and potassium. The potential for water and soil contamination from accidents and spills was analyzed by comparing geofluid composition with U.S. drinking water standards. Geofluids were found to present a potential risk to drinking water, if released, due to high concentrations of antimony, arsenic, lead, and mercury. That risk could be mitigated through proper design and engineering controls. The concentration and impact of noncondensible gases (NCG) dissolved in the geofluid was evaluated. The majority of NCG was either nitrogen or carbon dioxide, but a small number of geofluids contain potentially recoverable concentrations of hydrogen or methane.

15 GEOTHERMAL ENERGY↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Does Response to Induction Chemotherapy Predict Survival for Locally Advanced Non-Small-Cell Lung Cancer? Secondary Analysis of RTOG 8804/8808

Purpose: Induction chemotherapy (ICT) improves survival compared with radiotherapy (RT) alone in locally advanced non-small-cell lung cancer (LANSCLC) patients with good prognostic factors. Concurrent chemoradiotherapy (CCRT) is superior to ICT followed by RT. The question arises whether ICT response predicts the outcome of patients subsequently treated with CCRT or RT. Methods and Materials: Between 1988 and 1992, 194 LANSCLC patients were treated prospectively with ICT (two cycles of vinblastine and cisplatin) and then CCRT (cisplatin plus 63 Gy for 7 weeks) in the Radiation Therapy Oncology Group 8804 trial (n = 30) or ICT and then RT (60 Gy/6 wk) on Radiation Therapy Oncology Group 8808 trial (n = 164). Of the 194 patients, 183 were evaluable and 141 had undergone a postinduction assessment. The overall survival (OS) of those with complete remission (CR) or partial remission (PR) was compared with that of patients with stable disease (SD) or progressive disease (PD) after ICT. Results: Of the 141 patients, 6, 30, 99, and 6 had CR, PR, SD, and PD, respectively. The log-rank test showed a significant difference (p <0.0001) in OS when the response groups were compared (CR/PR vs. SD/PD). On univariate and multivariate analyses, a trend was seen toward a response to ICT with OS (p = 0.097 and p = 0.06, respectively). A squamous histologic type was associated with worse OS on univariate and multivariate analyses (p = 0.031 and p = 0.018, respectively). SD/PD plus a squamous histologic type had a hazard ratio of 2.25 vs. CR/PR plus a nonsquamous histologic type (p = 0.007) on covariate analysis. Conclusion: The response to ICT was associated with a significant survival difference when the response groups were compared. A response to ICT showed a trend toward, but was not predictive of, improved OS in LANSCLC patients. Patients with SD/PD after ICT and a squamous histologic type had the poorest OS. These data suggest that patients with squamous LANSCLC might benefit from immediate RT or CCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Control Following Permanent Prostate Brachytherapy: Effect of High Biologically Effective Dose on Biopsy Results and Oncologic Outcomes

Purpose: To determine factors that influence local control and systemic relapse in patients undergoing permanent prostate brachytherapy (PPB). Methods and Materials: A total of 584 patients receiving PPB alone or PPB with external beam radiation therapy (19.5%) agreed to undergo prostate biopsy (PB) at 2 years postimplantion and yearly if results were positive or if the prostate-specific antigen (PSA) level increased. Short-term hormone therapy was used with 280 (47.9%) patients. Radiation doses were converted to biologically effective doses (BED) (using alpha/beta = 2). Comparisons were made by chi-square analysis and linear regression. Survival was determined by the Kaplan-Meier method. Results: The median PSA concentration was 7.1 ng/ml, and the median follow-up period was 7.1 years. PB results were positive for 48/584 (8.2%) patients. Positive biopsy results by BED group were as follows: 22/121 (18.2%) patients received a BED of <=150 Gy; 15/244 (6.1%) patients received >150 to 200 Gy; and 6/193 (3.1%; p < 0.001) patients received >200 Gy. Significant associations of positive PB results by risk group were low-risk group BED (p = 0.019), intermediate-risk group hormone therapy (p = 0.011) and BED (p = 0.040), and high-risk group BED (p = 0.004). Biochemical freedom from failure rate at 7 years was 82.7%. Biochemical freedom from failure rate by PB result was 84.7% for negative results vs. 59.2% for positive results (p < 0.001). Cox regression analysis revealed significant associations with BED (p = 0.038) and PB results (p = 0.002) in low-risk patients, with BED (p = 0.003) in intermediate-risk patients, and with Gleason score (p = 0.006), PSA level (p < 0.001), and PB result (p = 0.038) in high-risk patients. Fifty-three (9.1%) patients died, of which eight deaths were due to prostate cancer. Cause-specific survival was 99.2% for negative PB results vs. 87.6% for positive PB results (p < 0.001). Conclusions: Higher radiation doses are required to achieve local control following PPB. A BED of >200 Gy with an alpha/beta ratio of 2 yields 96.9% local control rate. Failure to establish local control impacts survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Validation of a Prognostic Model Using Blood Biomarker Information for Prediction of Survival of Non-Small-Cell Lung Cancer Patients Treated With Combined Chemotherapy and Radiation or Radiotherapy Alone (NCT00181519, NCT00573040, and NCT00572325)

Purpose: Currently, prediction of survival for non-small-cell lung cancer patients treated with (chemo)radiotherapy is mainly based on clinical factors. The hypothesis of this prospective study was that blood biomarkers related to hypoxia, inflammation, and tumor load would have an added prognostic value for predicting survival. Methods and Materials: Clinical data and blood samples were collected prospectively (NCT00181519, NCT00573040, and NCT00572325) from 106 inoperable non-small-cell lung cancer patients (Stages I-IIIB), treated with curative intent with radiotherapy alone or combined with chemotherapy. Blood biomarkers, including lactate dehydrogenase, C-reactive protein, osteopontin, carbonic anhydrase IX, interleukin (IL) 6, IL-8, carcinoembryonic antigen (CEA), and cytokeratin fragment 21-1, were measured. A multivariate model, built on a large patient population (N = 322) and externally validated, was used as a baseline model. An extended model was created by selecting additional biomarkers. The model's performance was expressed as the area under the curve (AUC) of the receiver operating characteristic and assessed by use of leave-one-out cross validation as well as a validation cohort (n = 52). Results: The baseline model consisted of gender, World Health Organization performance status, forced expiratory volume, number of positive lymph node stations, and gross tumor volume and yielded an AUC of 0.72. The extended model included two additional blood biomarkers (CEA and IL-6) and resulted in a leave-one-out AUC of 0.81. The performance of the extended model was significantly better than the clinical model (p = 0.004). The AUC on the validation cohort was 0.66 and 0.76, respectively. Conclusions: The performance of the prognostic model for survival improved markedly by adding two blood biomarkers: CEA and IL-6.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Survey geometry and the internal consistency of recent cosmic shear measurements

We explore the impact of an update to the typical approximation for the shape noise term in the analytic covariance matrix for cosmic shear experiments that assumes the absence of survey boundary and mask effects. We present an exact expression for the number of galaxy pairs in this term based on the survey mask, which leads to more than a factor of three increase in the shape noise on the largest measured scales for the Kilo-Degree Survey (KiDS-450) real-space cosmic shear data. We compare the result of this analytic expression to several alternative methods for measuring the shape noise from the data and find excellent agreement. This update to the covariance resolves any internal model tension evidenced by the previously large cosmological best-fitting χ 2 for the KiDS-450 cosmic shear data. The best-fitting χ 2 is reduced from 161 to 121 for 118 degrees of freedom. We also apply a correction to how the multiplicative shear calibration uncertainty is included in the covariance. This change shifts the inferred amplitude of the correlation function to higher values. In conclusion, we find that this improves agreement of the KiDS-450 cosmic shear results with Dark Energy Survey Year 1 and Planck results.

79 ASTRONOMY AND ASTROPHYSICS↗