Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Droplet monitoring probe

A droplet monitoring system is disclosed for analysis of mixed-phase fluid flow in development of gas turbines. The system uses a probe comprising two electrical wires spaced a known distance apart and connected at one end to means for establishing a dc potential between the wires. A drop in the fluid stream momentarily contacting both wires simultaneously causes and electrical signal which is amplified, detected and counted.

Baughman, J. R.↗

Magnetic Damping of Solid Solution Semiconductor Alloys

The objective of this study is to conduct the Earth-based research sufficient to successfully propose a flight experiment (1) to experimentally test the validity of the modeling predictions applicable to the magnetic damping of convective flows in conductive melts as this applies to the bulk growth of solid solution semiconducting materials in the reduced gravitational levels available in low Earth orbit and (2) to assess the effectiveness of steady magnetic fields in reducing the fluid flows occurring in these materials during space processing. To achieve the objectives of this investigation, we are carrying out a comprehensive program in the Bridgman and floating-zone configurations using the solid solution alloy system Ge-Si. This alloy system was chosen because it has been studied extensively in environments that have not simultaneously included both low gravity and an applied magnetic field. Also, all compositions have a high electrical conductivity, and the materials parameters permit high growth rates compared to many other commonly studied alloy semiconductors. An important supporting investigation is determining the role, if any, that thermoelectromagnetic convection (TEMC) plays during growth of these materials in a magnetic field. Some compositional anomalies observed by us in magnetic grown crystals can only be explained by TEMC; this has significant implications for the deployment of a Magnetic Damping Furnace in space. This effect will be especially important in solid solutions where the growth interface is, in general, neither isothermal nor isoconcentrational. It could be important in single melting point materials, also, if faceting takes place producing a non-isothermal interface.

Szofran, Frank R.↗

SSME LOX post flow analyses/fluid structure interaction

Test firings of the Space Shuttle Main Engine (SSME) over the course of its development have resulted in several catastrophic failures. Some of these failures were due to breakage of the LOX posts that feed liquid oxygen into the main injector head of the engine. The objective was to perform a computational fluid flow analysis of a simplified SSME LOX post array using an existing viscous Navier-Stokes flow solver. A two-dimensional analysis was to be made. In addition, a finite element theory for treating the fluid/structure interaction between the posts and the hot gas environment was to be developed. The methodology used in computing the flow field through the LOX post array is described. Results are presented and discussed.

Source record↗

Experimental and Computational Analysis of Unidirectional Flow Through Stirling Engine Heater Head

A high efficiency Stirling Radioisotope Generator (SRG) is being developed for possible use in long-duration space science missions. NASA s advanced technology goals for next generation Stirling convertors include increasing the Carnot efficiency and percent of Carnot efficiency. To help achieve these goals, a multi-dimensional Computational Fluid Dynamics (CFD) code is being developed to numerically model unsteady fluid flow and heat transfer phenomena of the oscillating working gas inside Stirling convertors. In the absence of transient pressure drop data for the zero mean oscillating multi-dimensional flows present in the Technology Demonstration Convertors on test at NASA Glenn Research Center, unidirectional flow pressure drop test data is used to compare against 2D and 3D computational solutions. This study focuses on tracking pressure drop and mass flow rate data for unidirectional flow though a Stirling heater head using a commercial CFD code (CFD-ACE). The commercial CFD code uses a porous-media model which is dependent on permeability and the inertial coefficient present in the linear and nonlinear terms of the Darcy-Forchheimer equation. Permeability and inertial coefficient were calculated from unidirectional flow test data. CFD simulations of the unidirectional flow test were validated using the porous-media model input parameters which increased simulation accuracy by 14 percent on average.

Wilson, Scott D.↗

Unsteady, Transonic Flow Around Delta Wings Undergoing Coupled and Natural Modes Response: A Multidisciplinary Problem

The unsteady, three-dimensional Navier-Stokes equations coupled with the Euler equations of rigid-body dynamics are sequentially solved to simulate and analyze the aerodynamic response of a high angle of attack delta wing undergoing oscillatory motion. The governing equations of fluid flow and dynamics of the multidisciplinary problem are solved using a time-accurate solution of the laminar, unsteady, compressible, full Navier- Stokes equations with the implicit, upwind, Roe flux-difference splitting, finite-volume scheme and a four-stage Runge-Kutta scheme, respectively. The primary model under consideration consists of a 65 deg swept, sharp-edged, cropped delta wing of zero thickness at 20 deg angle of attack. In a freestream of Mach 0.85 and Reynolds number of 3.23 x 10(exp 6), the flow over the upper surface of the wing develops a complex shock system which interacts with the leading-edge primary vortices producing vortex breakdown. The effect of the oscillatory motion of the wing on the vortex breakdown and overall aerodynamic response is detailed to provide insight to the complicated physics associated with unsteady flows and the phenomenon of wing rock. Forced sinusoidal single and coupled mode rolling and pitching motion is presented for the wing in a transonic freestream. The Reynolds number, frequency of oscillation, and the phase angle are varied. Comparison between the single and coupled mode forced rolling and pitching oscillation cases illustrate the effects of coupling the motion. This investigation shows that even when coupled, forced rolling oscillation at a reduced frequency of 2(pi) eliminates the vortex breakdown which results in an increase in lift. The coupling effect for in phase forced oscillations show that the lift coefficient of the pitching-alone case and the rolling-moment coefficient of the rolling-alone case dominate the resulting response. However, with a phase lead in the pitching motion, the coupled motion results in a non-periodic response of the rolling moment. The second class of problems involve releasing the wing in roll to respond to the flowfield. Two models of sharp-edged delta wings, the previous 65 deg swept model and an 80 deg swept, sharp-edged delta wing, are used to observe the aerodynamic response of a wing free to roll in a transonic and subsonic freestream, respectively. These cases demonstrate damped oscillations, self-sustained limit cycle oscillations, and divergent rolling oscillations. Ultimately, an active control model using a mass injection system was applied on the surface of the wing to suppress the self-sustained limit cycle oscillation known as wing rock. Comparisons with experimental investigations complete this study, validating the analysis and illustrating the complex details afforded by computational investigations.

Menzies, Margaret Anne↗

Machine learning accelerated turbulence modeling of transient flashing jets

We report modeling the sudden depressurization of superheated liquids through nozzles is a challenge because the pressure drop causes rapid flash boiling of the liquid. The resulting jet usually demonstrates a wide range of structures, including ligaments and droplets, due to both mechanical and thermodynamic effects. As the simulation comprises increasingly numerous phenomena, the computational cost begins to increase. One way to moderate the additional cost is to use machine learning surrogacy for specific elements of the calculation. This study presents a machine learning-assisted computational fluid dynamics approach for simulating the atomization of flashing liquids accounting for distinct stages, from primary atomization to secondary breakup to small droplets using the Σ - Y model coupled with the homogeneous relaxation model. Notably, the models for thermodynamic non-equilibrium (HRM) and Σ - Y are coupled, for the first time, with a deep neural network that simulates the turbulence quantities, which are then used in the prediction of superheated liquid jet atomization. The data-driven component of this method is used for turbulence modeling, avoiding the solution of the two-equation turbulence model typically used for Reynolds-averaged Navier-Stokes simulations for these problems. Both the accuracy and speed of the hybrid approach are evaluated, demonstrating adequate accuracy and at least 25% faster computational fluid dynamics simulations than the traditional approach. This acceleration suggests that perhaps additional components of the calculation could be replaced for even further benefit. Published under an exclusive license by AIP Publishing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tank 27 Solids Disturbance Testing Using M-Star for the Impact of CSMP Usage on Blend Tank Mixing Effectiveness

Savannah River Mission Completion (SRMC) plans to operate Tank 27as a blend tank for future waste disposal operations. It is desirable to avoid additional worker exposure by using the planned commercial submersible mixing pump (CSMP) installations in Risers B2 and B4 to function as the blend pumps for prolonged blend tank operations. The purpose of this task is to evaluate the impacts to mixing across a range of pump installation heights from 1 to 201 inches above the tank floor. The CSMPs shall maintain adequate blending within a 24 hour maximum timeframe and an adequate nozzle discharge velocity as outlined in U-ESR-G-00030, using the specifications of the planned CSMPs listed in PO SRRA149971 and M-DS-G-00081. Specifications include: maximum pump diameter of D=22.5 in., dual nozzles placed tangentially opposed with nominal inside diameter of 2 in., total flow range (both nozzles combined) of 500 to 1950 GPM and maximum RPM of 1800. Tank 27 is expected to have a fill height maximum of 360". This analysis began by using results from the 2010 testing and applying them to the Tank 27 design to calculate a mixing time as a function of pump flow rate. These results were modified to account for the higher liquid level in Tank 27. Once the liquid level was increased to 360 inches, the results were modified to account for a higher viscosity in Tank 27 than in the testing. Once the viscosity was increased, the effect of changing pump elevation was applied to calculations of the mixing time in Tank 27. Finally, the uncertainty from the testing was included in the analysis to recommend a blend time as a function of pump flow rate and elevation. The conclusion from this study is that the particles in tank 27 will be suspended at both the 600 and 900 gpm flow rates. Only particles above 90 micron will not be suspended in significant amounts when the flow rate is 600 gpm. At 900 gpm even 100 micron particles were thoroughly suspended in the tank. From the series of simulations it has been concluded that it will not be possible to mix tank 27 at the proposed fluid flow rates and not suspend the solid particles at the bottom of the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modular thermal analyzer routine, volume 1

The Modular Thermal Analyzer Routine (MOTAR) is a general thermal analysis routine with strong capabilities for performing thermal analysis of systems containing flowing fluids, fluid system controls (valves, heat exchangers, etc.), life support systems, and thermal radiation situations. Its modular organization permits the analysis of a very wide range of thermal problems for simple problems containing a few conduction nodes to those containing complicated flow and radiation analysis with each problem type being analyzed with peak computational efficiency and maximum ease of use. The organization and programming methods applied to MOTAR achieved a high degree of computer utilization efficiency in terms of computer execution time and storage space required for a given problem. The computer time required to perform a given problem on MOTAR is approximately 40 to 50 percent that required for the currently existing widely used routines. The computer storage requirement for MOTAR is approximately 25 percent more than the most commonly used routines for the most simple problems but the data storage techniques for the more complicated options should save a considerable amount of space.

Oren, J. A.↗

Two-Axis Direct Fluid Shear Stress Sensor for Aerodynamic Applications

This miniature or micro-sized semiconductor sensor design provides direct, nonintrusive measurement of skin friction or wall shear stress in fluid flow situations in a two-axis configuration. The sensor is fabricated by microelectromechanical system (MEMS) technology, enabling small size and multiple, low-cost reproductions. The sensors may be fabricated by bonding a sensing element wafer to a fluid-coupling element wafer. Using this layered machine structure provides a truly three-dimensional device.

Bajikar, Sateesh S.↗

Fluid shear stress stimulates prostaglandin and nitric oxide release in bone marrow-derived preosteoclast-like cells

Bone is a porous tissue that is continuously perfused by interstitial fluid. Fluid flow, driven by both vascular pressure and mechanical loading, may generate significant shear stresses through the canaliculi as well as along the bone lining at the endosteal surface. Both osteoblasts and osteocytes produce signaling factors such as prostaglandins and nitric in response to fluid shear stress (FSS); however, these humoral agents appear to have more profound affects on osteoclast activity at the endosteal surface. We hypothesized that osteoclasts and preosteoclasts may also be mechanosensitive and that osteoclast-mediated autocrine signaling may be important in bone remodeling. In this study, we investigated the effect of FSS on nitric oxide (NO), prostaglandin E(2) (PGE(2)), and prostacyclin (PGI(2)) release by neonatal rat bone marrow-derived preosteoclast-like cells. These cells were tartrate-resistant acid phosphatase (TRAP) positive, weakly nonspecific esterase (NSE) positive, and capable of fusing into calcitonin-responsive, bone-resorbing, multinucleated cells. Bone marrow-derived preosteoclast-like cells exposed for 6 h to a well-defined FSS of 16 dynes/cm(2) produced NO at a rate of 7.5 nmol/mg protein/h, which was 10-fold that of static controls. This response was completely abolished by 100 microM N(G)-amino-L-arginine (L-NAA). Flow also stimulated PGE(2) production (3.9 microg/mg protein/h) and PGI(2) production (220 pg/mg protein/h). L-NAA attenuated flow-induced PGE(2) production by 30%, suggesting that NO may partially modulate PGE(2) production. This is the first report demonstrating that marrow derived cells are sensitive to FSS and that autocrine signaling in these cells may play an important role in load-induced remodeling and signal transduction in bone. Copyright 2000 Academic Press.

NASA Discipline Cell Biology↗

Phase-field modeling of rate-dependent fluid-driven fracture initiation and propagation

The rate-dependent behavior associated with deformation and fracturing of materials, such as natural rocks, poses significant challenges for modeling. In addition to the complications of the viscoelastic response, the speed of fracture propagation reflects micromechanical mechanisms in the fracture process zone(FPZ). In order to represent these complicated behaviors, a thermodynamically consistent, rate-dependent fracture model is required. Based on rigorous thermodynamic principles, we derive a rate-dependent phase-field mechanical model coupled with single-phase fluid flow in both the matrix and the fracture. The model is guaranteed to satisfy energy conservation during fracture propagation. Here, the system of equations is solved using the introduced solution procedure and a novel preconditioner that accounts for the complex fluid-structure interaction. The proposed phase-field model is tested against several benchmark problems on solid-fluid coupling, fluid-driven fracture propagation and rate-dependent viscoelastic deformation. The model serves as a strong basis for investigating rate-dependent fracturing experiments and for making predictions of material behaviors under new conditions.

42 ENGINEERING↗

Accumulator

An accumulator particularly adapted for use in controlling the pressure of a stream of fluid in its liquid phase utilizing the fluid in its gaseous phase was designed. The accumulator is characterized by a shell defining a pressure chamber having an entry throat for a liquid and adapted to be connected in contiguous relation with a selected conduit having a stream of fluid flowing through the conduit in its liquid phase. A pressure and volume stabilization tube, including an array of pressure relief perforations is projected into the chamber with the perforations disposed adjacent to the entry throat for accommodating a discharge of the fluid in either gaseous or liquid phases, while a gas inlet and liquid to gas conversion system is provided, the chamber is connected with a source of the fluid for continuously pressuring the chamber for controlling the pressure of the stream of liquid.

Fenwick, J. R.↗

Development of an integrated BEM (Boundary Element Mesh) for hot fluid-structure interaction

A boundary integral representation for a coupled approach to fluid flow and solid deformation problems associated with the design of hot-section components such as those in the Space Shuttle Main Engine is discussed. The formulation is based on the fundamental analytical solution of the Navier-Stokes equation for fluid velocity in an infinite domain. This fundamental solution was obtained by decomposing a Navier-Stokes equation into vorticity and dilation transport equations. A boundary integral involving convolutions in time was then constructed in which the convective terms appear in the volume integral.

Dargush, G. F.↗

Effect of convection on osteoblastic cell growth and function in biodegradable polymer foam scaffolds

Culture of seeded osteoblastic cells in three-dimensional osteoconductive scaffolds in vitro is a promising approach to produce an osteoinductive material for repair of bone defects. However, culture of cells in scaffolds sufficiently large to bridge critical-sized defects is a challenge for tissue engineers. Diffusion may not be sufficient to supply nutrients into large scaffolds and consequently cells may grow preferentially at the periphery under static culture conditions. Three alternative culturing schemes that convect media were considered: a spinner flask, a rotary vessel, and a perfusion flow system. Poly(DL-lactic-co-glycolic acid) (PLGA) foam discs (12.7 mm diameter, 6.0 mm thick, 78.8% porous) were seeded with osteoblastic marrow stromal cells and cultured in the presence of dexamethasone and L-ascorbic acid for 7 and 14 days. Cell numbers per foam were found to be similar with all culturing schemes indicating that cell growth could not be enhanced by convection, but histological analysis indicated that the rotary vessel and flow system produced a more uniform distribution of cells throughout the foams. Alkaline phosphatase (ALP) activity per cell was higher with culture in the flow system and spinner flask after 7 days, while no differences in osteocalcin (OC) activity per cell were observed among culturing methods after 14 days in culture. Based on the higher ALP activity and better cell uniformity throughout the cultured foams, the flow system appears to be the superior culturing method, although equally important is the fact that in none of the tests did any of the alternative culturing techniques underperform the static controls. Thus, this study demonstrates that culturing techniques that utilize fluid flow, and in particular the flow perfusion system, improve the properties of the seeded cells over those maintained in static culture.

NASA Discipline Cell Biology↗

National Combustion Code, a Multidisciplinary Combustor Design System, Will Be Transferred to the Commercial Sector

The NASA Lewis Research Center and Flow Parametrics will enter into an agreement to commercialize the National Combustion Code (NCC). This multidisciplinary combustor design system utilizes computer-aided design (CAD) tools for geometry creation, advanced mesh generators for creating solid model representations, a common framework for fluid flow and structural analyses, modern postprocessing tools, and parallel processing. This integrated system can facilitate and enhance various phases of the design and analysis process.

Steele, Gynelle C.↗

Operation of a Heat Pipe with Multiple Heat Loads Under Reflux Mode

"Heat pipes are being used on many spacecraft to acquire heat dissipated by the payload and transport the heat to a remote radiator. In instrument-level or spacecraft-level ground testing, many heat pipes are placed in a gravity-driven reflux mode where the condenser is well above the evaporator, resulting in the formation of a liquid pool at the bottom of the heat pipe. If a head load is applied to a site that is in contact with the liquid pool, the generated vapor will flow upward to the condenser and the condensate will fall back to the evaporator due the influence of gravity. Hence, the heat pipe can operate steadily under reflux mode because the heated site always has sufficient liquid supply to sustain the fluid flow. In contrast, when a heat load is applied to a site remote from the liquid pool, the heat pipe will be unable to transfer heat through liquid evaporation unless the heated site has a chance to be in contact with liquid. This can be accomplished by applying an additional heat load to the liquid pool to establish a reflux flow so that the remote site can capture the falling condensate. An experimental investigation was conducted to study the effect of gravity on the thermal performance of a heat pipe under reflux mode with multiple heat loads. An aluminum ammonia heat pipe with internal axial grooves was placed in a vertical position. Cooling was provided to the top of the heat pipe, and heat was applied to three sites below the condenser with various heat distributions. One of the heated sites was above the liquid pool, and two were in direct contact with the liquid pool. Test results showed that when a heat load was applied to either one or both of the lower sites, the heat pipe could run steadily under reflux mode. After a reflux flow had been established, a heat load could be applied to the upper site. If the upper site could capture sufficient liquid falling from the condenser to handle its heat load solely by liquid evaporation, the heat pipe could reach steady operation. Otherwise, the temperature of the upper site would oscillate due to its intermittent contact with the falling liquid. For a given heat load to the upper site, the amplitude of temperature oscillation decreased with an increasing heat load to the lower sites because there was more falling condensate available for the upper site to capture. Moreover, the temperature oscillation disappeared completely when the total heat loads to lower sites exceeded a threshold power, and the threshold power increased with an increasing heat load to the upper site."

Ku, Jentung↗

Regional and Local Geothermal Potential Evaluation: Examples from the Great Basin, USA, Iceland and East Africa

In both tectonically and magmatically mediated geothermal systems, geologic structures play a crucial role in focusing geothermal fluid circulation in the upper crust. In a variety of geothermal provinces worldwide, normal and strike-slip faults, caldera related faults, as well as fractures and fissures related to dikes and other magmatic intrusions generate the fracture permeability utilized for geothermal circulation. Localities where the above structures intersect and interact are characterized by the most robust generation and maintenance of fracture permeability, and therefore are the most favorable conduits for geothermal circulation. We present an evaluation of the structural geometries that tend to generate high density faulting and fracturing and an evaluation of the orientations of those structures with respect to the ambient stress conditions in three regions of high geothermal potential; The Great Basin, USA, Iceland, and east Africa. These analyses provide first-order constraints on areas that have favorable conditions for permeability and where future exploration for geothermal resources could be focused. In the Great Basin, USA, fault step-overs, fault terminations and accommodation zones are among the most common structural settings of known geothermal activity. Analysis of the geometry of these structures with respect to the ambient stress conditions reveals locations where faults associated with these structures are favorably oriented for enhanced fracture permeability. In magmatically active extensional provinces, like Iceland and east Africa, heat associated with shallow magmatic intrusions beneath volcanic centers drives geothermal circulation in near-surface fracture permeability conduits. Accentuated fault and fracture density and fracture permeability is generated by both axially oriented faults and fractures associated with axial rift zones and radially oriented structures near volcanic centers. Although heat from magmatic intrusion is most robust at volcanic centers, a high density of young intrusions may actually result in decreased permeability through closing of fracture networks. The locations of these three types of features; axial faults and fractures, radial structures, and young magmatic intrusions, all play a critical role in determining the most favorable locations for fracture permeability and fluid flow in magmatic geothermal systems. Within and around the margins of volcanic centers, where radial structures associated with volcanic centers interact and intersect with axially oriented structures associated with axial extension are the most favorable locations for fracture permeability and geothermal fluid circulation in magmatic extensional geothermal systems.

15 GEOTHERMAL ENERGY↗

Geophysical Imaging of Geothermal Systems Spanning Various Geologic Settings

Despite the wide range of geologic settings in which geothermal systems reside, many systems share characteristics that can be targeted by geophysical techniques. Over the last few years, the authors have used potential field and magnetotelluric (MT) methods to jointly image and characterize numerous geothermal systems in various geologic and tectonic settings. This includes systems in the Basin and Range, Washington Cascade Range, Northeastern Oregon, and the Snake River Plain. The principal geothermal targets are areas of elevated temperatures near fault interactions that promote permeability and fluid flow. Gravity, magnetic, and MT data are all sensitive to different physical parameters that together form a complementary set of tools for characterizing subsurface structure and identifying favorable geothermal targets. In general, potential fields delineate important geologic structures and MT locates fluids and zones of hydrothermal alteration. Joint interpretation of these complementary methods, along with other geologic information, provides a robust framework for geothermal prospecting and understanding a hydrothermal system. Specifically, common geothermal targets lie along potential field gradients and are associated with an electrically conductive anomaly that resides in the less-dense, less-magnetic material.

15 GEOTHERMAL ENERGY↗