Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron Accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Fabrication and Measurements of 500 MHz Double Spoke Cavity

A 500 MHz β0=1 double spoke cavity has been designed and optimized for a high velocity application such as a compact electron accelerator at the Center for Accelerator Science at Old Dominion University [1] and the fabrication was recently completed at Jefferson Lab. The geometry specific to the double spoke cavity required a variety of tooling and fixtures. Also a number of asymmetric weld joints were expected to make it difficult to maintain minimal geometric deviation from the design. This paper will report the fabrication procedure, resulting tolerance from the design, initial test results and the lessons learned from the first β0=1 double spoke cavity fabrication.

Park, HyeKyoung↗

The Composition of GRB Jets and the ICMART Model

Models of gamma ray bursts (GRBs) are drawn from observations of light curves, spectra, and spectral evolution. The ICMART (Internal Collision-induced MAgnetic Reconnection & Turbulence) model and some of its features are presented. Increasing evidence points towards Poynting-flux-dominated jets in at least some (even a good fraction of) GRBs. The main emission component (Band) is of a synchrotron emission origin, produced by electrons accelerated in the emission region. The data seem to require that magnetic reconnection in the moderately-high sigma regime is the mechanism to accelerate particles. Extensive numerical simulations are needed to verify physical details of such a model, and some encouraging results have been obtained.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an X-Ray Talbot-Lau Moire Deflectometer of Fast Density Profile Measurements of Dense Plasmas Generated by Beam Target Interactions

For the first time an x-ray Talbot-Lau moiré deflectometer is being developed that will use a flash tube source and fast detector for dynamic density gradient measurements. In Talbot-Lau moiré deflectometry, an x-ray grating makes an mage of itself on a second grating (the Talbot effect) to produce a moiré pattern on a detector. The test object is placed between these gratings, with variations in index of refraction changing the pattern. A third grating in front of an incoherent x-ray source produces an array of coherent sources. With a 150 kV x-ray flash tube as the source, the gratings are placed in a glancing angle setup for performance at ~60 keV. The detector is a gated CCD with a fast scintillator for x-ray conversion. This diagnostic, designed for the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) at Los Alamos National Laboratory, measures the density profile of dense plasma plumes ejected from beam-target interactions. DARHT has two high-current, pulsed, inductive linear electron accelerators with bremsstrahlung targets at the end of each beam line to create 2-D radiographic images of hydrodynamic tests. One multipulse accelerator has up to four beam pulses striking the same target within 2 μs. Computer simulations that model target evolution and ejected material between pulses are used to design these targets for optimal radiographic performance; the x-ray deflectometer will directly measure density gradients in the ejected plumes and provide the first experimental constraints to these models. During the first year, currently underway, the diagnostic systems are being designed. In year two, the flash tube and fast detector will be deployed at DARHT for radiographic imaging while the deflectometer is built and tested on the bench with a continuous source. In year three, the fast deflectometer will be installed on DARHT and density measurements will be performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical Processing Activities for 99 Mo production by (γ,n) and (n,γ) reactions using enriched 100 Mo and 98 Mo targets

Recently, several technologies were proposed for the production of 99 Mo/ 99 mTc without the use of 235 U targets. These technologies offer the potential for a lower-cost alternative to fission produced 99 Mo, but with lower yields of 99 Mo or 99 mTc. Enriched 98 Mo or 100 Mo targets are necessary for economic production of several thousand Ci of 99 Mo. Argonne, in collaboration with Los Alamos and Oak Ridge National Laboratories, are assisting NorthStar Medical Technologies in the development of a domestic supply of 99 Mo. NorthStar’s short-term plan is to produce 99 Mo using 98 Mo(n,)γ 99 Mo reaction at MURR, and their long-term solution is to produce 99 Mo using an electron accelerator via the 100 Mo(,γn) 99 Mo reaction. The latest experimental results from irradiation of enriched 100 Mo targets, large-scale dissolution studies, and development of enriched material recycle process will be presented

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Bremsstrahlung Converter Designs for Ultra High Dose Rate Radiotherapy Systems

Ultra-high dose rates (UHDR) have been shown to improve the therapeutic index in the treatment of cancer using external beam radiotherapy in many preclinical settings by inducing the so-called “FLASH” effect [1]; however, the underlying biological and physical mechanism(s) are still unknown. Recent work has been to expand the energy range of photons used in UHDR studies from keV photons generated in synchrotron to photons less than 8 MeV produced by accelerated electrons undergoing the bremsstrahlung interaction [2]. This work is a part of the FLASH-Experimental X-ray small Animal Conformal Therapy (FLASH-EXACT) project is aimed at producing a preclinical system that induces the FLASH effect with photons >10 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

12 GeV CEBAF - The Physics and Experiments

In this talk the role of spin and polarization is discussed in experimental search for new excited baryon states and in the study of the internal quark-gluon structure of the proton and neutron. Also the perspective of spin physics at the 12 GeV CEBAF electron accelerator is discussed and what we hope to learn about fundamental properties of hadrons such as their multi-dimensional structure through the momentum and spatial imaging, and about the forces on the quarks in the proton and how quark confinement may be realized through the spatial distribution of such forces.

Burkert, Volker↗

The Experimental Programs on Light Pseudoscalar Meson Decays

The decays of the low-lying pseudoscalar mesons (?0, ?, and ??) allow access to a plethora of physics probes, from measurements of fundamental properties of matter such as the up-down quark mass ratio, to studies of channels that access higher-order terms in Chiral Perturbation theory, to tests of fundamental symmetries and searches for signatures of physics beyond the Standard Model. Several experiments have studied pseudoscalar decays: these experiments include PrimEx in Hall B at Jefferson Lab, A2 at the MAMI electron accelerator facility, the KLOE-II experiment at the DA?NE ?-factory, WASA-at-COSY at the cooler synchrotron COSY storage ring, and BESIII at the Beijing charm factory. In Hall D at Jefferson Lab, PrimEx-eta uses the Primakoff process to measure the ? radiative width using the GlueX spectrometer. In the near future the Jefferson Lab Eta Factory (JEF) experiment will use the GlueX spectrometer with an upgraded forward calorimeter to study ?(?) decay channels with a focus on all-neutral final states. Finally, a proposal for a new experiment, ``Rare Eta Decays with a TPC for Optical Photons'' (REDTOP) utilizing a proton beam on fixed targets, is under development. Highlights from previous and ongoing experiments and plans for future experiments will be presented.

Taylor, Simon↗

Development for fissile assay in recycled fuel using lead slowing down spectrometer

A future nuclear energy system is under development to turn spent fuels produced by PWRs into fuels for a SFR (Sodium Fast Reactor) through the pyrochemical process. The knowledge of the isotopic fissile content of the new fuel is very important for fuel safety. A lead slowing down spectrometer (LSDS) is under development to analyze the fissile material content (Pu{sup 239}, Pu{sup 241} and U{sup 235}) of the fuel. The LSDS requires a neutron source, the neutrons will be slowed down through their passage in a lead medium and will finally enter the fuel and will induce fission reactions that will be analysed and the isotopic content of the fuel will be then determined. The issue is that the spent fuel emits intense gamma rays and neutrons by spontaneous fission. The threshold fission detector screens the prompt fast fission neutrons and as a result the LSDS is not influenced by the high level radiation background. The energy resolution of LSDS is good in the range 0.1 eV to 1 keV. It is also the range in which the fission reaction is the most discriminating for the considered fissile isotopes. An electron accelerator has been chosen to produce neutrons with an adequate target through (e{sup -},γ)(γ,n) reactions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

{sup 99}Mo Production at KIPT Neutron Source Facility

Argonne National Laboratory (ANL) and Kharkov Institute of Physics and Technology (KIPT) have cooperated on the construction of the Neutron Source Facility (NSF) at KIPT, Kharkov (Ukraine). The NSF facility consists of an electron accelerator driven system (ADS) generating 300 kW of thermal power for multiple applications, including medical isotope production. ANL performed extensive analyses including medical isotopes production, reactivity monitoring, operations and control, refueling, cold neutron source design, target design,and radiation shielding. The present study focuses on the use of the KIPT NSF for medical isotope production. Medical isotopes are radioactive isotopes with short half-lives used in diagnostic and therapeutic medical procedures. For example, brain cancer is difficult to treat by ordinary surgery and only brachytherapy with {sup 131}Cs, which has 9.7 days half-life, has shown effective results on the patients. {sup 99m}Tc is the most common medical isotope used in medical diagnoses because the wavelength of its gamma radiation (8.8 pm) is about the same as the conventional X-ray diagnostic devices. {sup 99m}Tc has 6 hours half-life, therefore it cannot be stored because it decays into {sup 99}Tc. The parent of {sup 99m}Tc is {sup 99}Mo, which has 66 hours half-life. Consequently, the delivery of {sup 99m}Tc occurs through shipping {sup 99}Mo samples to the medical facilities. The Neutron Source Facility of KIPT is the first ADS in the world operating at non-zero power and allows producing several isotopes for medical applications. The total power of the facility is about 300 kW, including ∼200 kW from fission reactions. The construction of the NSF has been already completed and operations will start during year 2016. After 20 irradiation days, {sup 82}Br, {sup 64}Cu, {sup 165}Dy, {sup 166}Ho, {sup 192}Ir, {sup 194}Ir, {sup 186}Re, {sup 188}Re and {sup 153}Sm have specific activities, larger than 100 MBq/mg without taking into account the self-shielding effect and therefore they are good candidates for production. The self-shielding effect plays an important role for all nuclide parents that have a large microscopic capture cross section. This effect reduces the reaction rate and therefore the specific activity. For instance, the analyses of molybdenum trioxide (MoO{sub 3}) irradiation samples have shown that the self-shielding effect may reduce the specific activity by a factor 1.4. The metallic form of natural molybdenum produces a higher specific activity, relative to the trioxide form. Analyses on the 6-day Ci {sup 99}Mo activity have shown that is possible to perform between 40 to 310 {sup 99m}Tc medical procedures per MoO{sub 3} irradiation week. The number of medical procedures depends on the diagnosed organ and the weight of the patient. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo Simulation On X-Ray Produced At High Intensity Laser Facilities - Paper 20

With the rapid development of laser technology, a number of high intensity laser devices are emerging in the world. At the same time, the ionizing radiation hazard produced from the interaction between high intensity laser and solid target has gradually been observed. Because Laser-plasma interactions can accelerate electrons to high energies (10's to 1000's of keV). These hot electrons subsequently interact with ions in the target and generate Bremsstrahlung X-rays, which become an ionizing radiation source. Measurements show that significant amounts of radiation can be generated from this ionizing radiation source at high intensity laser facilities. However, very limited studies have been made on the laser-induced ionizing radiation hazard and the protection issues. In this paper, a X-ray dose calculation model was developed and X-ray dose produced in the interaction between high intensity laser and solid target was studied by simulation using Monte Carlo code. (authors)

42 ENGINEERING↗

Pulse Radiolysis Study of Radiation Effect on Molten Salt

The molten salt reactor concept, where nuclear fuel is dissolved in a molten salt that also serves as the heat transfer fluid, is a leading candidate for next generation nuclear reactors. This necessitates a thorough understanding of radiation effects on molten salt media to support the design, development, and deployment of such reactors. Early, pioneering pulse radiolysis molten salt experiments observed key primary radiolysis products such as the solvated electron (esolv?) and dichloride radical anion (Cl2??), but left many fundamental mechanistic and reactivity questions unanswered. Here we report on the reaction kinetics of esolv? and Cl2?? in molten LiCl-KCl eutectic salt doped with Zn2+ ion, using electron pulse radiolysis to observe the transient behavior from nanosecond to microsecond time scales. Experiments were performed at the BNL Laser-Electron Accelerator Facility using a recently-developed high-temperature sample holder. Prompt formation of esolv? and Cl2?? are observed; esolv? decays within hundreds of nanoseconds while Cl2?? decays more slowly by second-order kinetics, more likely by cross-recombination rather than disproportionation. This work was supported as part of the Molten Salts in Extreme Environments Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Progress in Antiproton Production at the Fermilab Tevatron Collider

Fermilab Collider Run II has been ongoing since 2001. During this time peak luminosities in the Tevatron have increased from approximately 10 x 10{sup 30} cm{sup -2}sec{sup -1} to 300 x 10{sup 30} cm{sup 02}sec{sup -1}. A major contributing factor in this remarkable performance is a greatly improved antiproton production capability. Since the beginning of Run II, the average antiproton accumulation rate has increased from 2 x 10{sup 10}{anti p}/hr to about 24 x 10{sup 10}{anti p}/hr. Peak antiproton stacking rates presently exceed 28 x 10{sup 10}{anti p}/hr. The antiproton stacking rate has nearly doubled since 2005. It is this recent progress that is the focus of this paper. The process of transferring antiprotons to the Recycler Ring for subsequent transfer to the collider has been significantly restructured and streamlined, yielding additional cycle time for antiproton production. Improvements to the target station have greatly increased the antiproton yield from the production target. The performance of the Antiproton Source stochastic cooling systems has been enhanced by upgrades to the cooling electronics, accelerator lattice optimization, and improved operating procedures. In this paper, we will briefly report on each of these modifications.

43 PARTICLE ACCELERATORS↗

An Electron Fixed Target Experiment to Search for a New Vector Boson A' Decaying to e+e-

We describe an experiment to search for a new vector boson A' with weak coupling {alpha}' {approx}> 6 x 10{sup -8} {alpha} to electrons ({alpha} = e{sup 2}/4{pi}) in the mass range 65 MeV < m{sub A'} < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the 'dark photon' A' with the photon - one of the very few ways in which new forces can couple to the Standard Model - and have received considerable attention as an explanation of various dark matter related anomalies. A' bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e{sup +}e{sup -} spectrum. We summarize the experimental approach described in a proposal submitted to Jefferson Laboratory's PAC35, PR-10-009. This experiment, the A' Experiment (APEX), uses the electron beam of the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory (CEBAF) at energies of {approx} 1-4 GeV incident on 0.5-10% radiation length Tungsten wire mesh targets, and measures the resulting e{sup +}e{sup -} pairs to search for the A' using the High Resolution Spectrometer and the septum magnet in Hall A. With a {approx} 1 month run, APEX will achieve very good sensitivity because the statistics of e{sup +}e{sup -} pairs will be {approx} 10,000 times larger in the explored mass range than any previous search for the A' boson. These statistics and the excellent mass resolution of the spectrometers allow sensitivity to {alpha}'/{alpha} one to three orders of magnitude below current limits, in a region of parameter space of great theoretical and phenomenological interest. Similar experiments could also be performed at other facilities, such as the Mainz Microtron.

43 PARTICLE ACCELERATORS↗

Apparatus and method for inspecting a sealed container

An apparatus for inspecting a sealed container is disclosed and which includes a pulsed electron accelerator which is positioned in spaced relation relative to a first side of the sealed container, and which produces a pulsed beam of photons which passes through the sealed container and any contents enclosed within the sealed container; a detector positioned in spaced relation relative to a second, opposite side of the sealed container, and which receives the pulsed beam of photons which passes through the contents of the sealed container, and which produces an output signal; and a computer for developing a visible image from the output signal of the detector which depicts the contents of the sealed container.

47 OTHER INSTRUMENTATION↗

LibERI—A portable and performant multi-GPU accelerated library for electron repulsion integrals via OpenMP offloading and standard language parallelism

A portable and performant graphics processing unit (GPU)-accelerated library for electron repulsion integral (ERI) evaluation, named LibERI, has been developed and implemented via directive-based (e.g., OpenMP and OpenACC) and standard language parallelism (e.g., Fortran DO CONCURRENT). Offloaded ERIs consist of integrals over low and high contraction s, p, and d functions using the rotated-axis and Rys quadrature methods. GPU codes are factorized based on previous developments with two layers of integral screening and quartet presorting. In this work, the density screening is moved to the GPU to enhance the computational efficacy for large molecular systems. Here, the L-shells in the Pople basis set are also separated into pure S and P shells to increase the ERI homogeneity and reduce atomic operations and the memory footprint. LibERI is compatible with any quantum chemistry drivers supporting the MolSSI Driver Interface. Benchmark calculations of LibERI interfaced with the GAMESS software package were carried out on various GPU architectures and molecular systems. The results show that the LibERI performance is comparable to other state-of-the-art GPU-accelerated codes (e.g., TeraChem and GMSHPC) and, in some cases, outperforms conventionally developed ERI CUDA kernels (e.g., QUICK) while fully maintaining portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗