Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Improved constraints on isotropic shift and anisotropies of the speed of light using rotating cryogenic sapphire oscillators

We demonstrate that Michelson-Morley tests, which detect direction-dependent anisotropies in the speed of light, can also be used to place limits upon isotropic deviations of the vacuum speed of light from c, as described by the photon-sector standard model extension parameter {kappa}-tilde{sub tr}. A shift in the speed of light that is isotropic in one inertial frame implies anisotropic shifts in others. Using observer Lorentz covariance, we derive the time-dependent variations in the relative resonance frequencies of a pair of electromagnetic resonators that would be generated by such a shift in the rest frame of the Sun. A new analysis of a recent experimental test of relativity using this result constrains {kappa}-tilde{sub tr} with a precision of 7.4x10{sup -9}. This represents the first constraint on {kappa}-tilde{sub tr} by a Michelson-Morley experiment and the first analysis of a single experiment to simultaneously set limits on all nine nonbirefringent terms in the photon sector of the minimal standard model extension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Paul Trapping of Radioactive {sup 6}He{sup +} Ions and Direct Observation of Their {beta} Decay

We demonstrate that abundant quantities of short-lived {beta} unstable ions can be trapped in a novel transparent Paul trap and that their decay products can directly be detected in coincidence. Low energy {sup 6}He{sup +} (807 ms half-life) ions were extracted from the SPIRAL source at GANIL, then decelerated, cooled, and bunched by means of the buffer gas cooling technique. More than 10{sup 8} ions have been stored over a measuring period of six days, and about 10{sup 5} decay coincidences between the beta particles and the {sup 6}Li{sup ++} recoiling ions have been recorded. The technique can be extended to other short-lived species, opening new possibilities for trap assisted decay experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on Covariant Dark-Matter–Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA. We report on the results of a relativistic extension to the nonrelativistic effective field theory (NREFT) from a 5.5 t fiducial mass and 60 live days of exposure. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the weakly interacting massive particle which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0 keV nr to 270 keV nr , we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ ⁢eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44–52 μ ⁢eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, 𝑔 𝑎⁢𝛾⁢𝛾 , in this mass range at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification and distribution of pathogens coinfecting with Brucella spp., Coxiella burnetii and Rift Valley fever virus in humans, livestock and wildlife

Zoonotic diseases, such as brucellosis, Q fever and Rift Valley fever (RVF) caused by Brucella spp., Coxiella burnetii and RVF virus, respectively, can have devastating effects on human, livestock, and wildlife health and cause economic hardship due to morbidity and mortality in livestock. Coinfection with multiple pathogens can lead to more severe disease outcomes and altered transmission dynamics. These three pathogens can alter host immune responses likely leading to increased morbidity, mortality and pathogen transmission during coinfection. Developing countries, such as those commonly afflicted by outbreaks of brucellosis, Q fever and RVF, have high disease burden and thus common coinfections. A literature survey provided information on case reports and studies investigating coinfections involving the three focal diseases. Fifty five studies were collected demonstrating coinfections of Brucella spp., C. burnetii or RVFV with 50 different pathogens, of which 64% were zoonotic. While the literature search criteria involved ‘coinfection’, only 24/55 studies showed coinfections with direct pathogen detection methods (microbiology, PCR and antigen test), while the rest only reported detection of antibodies against multiple pathogens, which only indicate a history of co-exposure, not concurrent infection. These studies lack the ability to test whether coinfection leads to changes in morbidity, mortality or transmission dynamics. We describe considerations and methods for identifying ongoing coinfections to address this critical blind spot in disease risk management.

60 APPLIED LIFE SCIENCES↗

CodeScribe Agent

SF-26-086 CodeScribe introduces a structured, multi-stage pipeline that combines deterministic program analysis with LLM-powered translation to enable incremental, testable Fortran-to-C++ migration. First, `code-scribe index` traverses the project directory tree and produces `scribe.yaml` metadata files recording all modules, subroutines, and functions at each level, giving the LLM accurate structural context instead of a hallucinated codebase model. Second, `code-scribe draft` performs the deterministic portion of translation — converting Fortran types to C++ equivalents, replacing `use` statements with `#include` and `using namespace` directives, and detecting constructs requiring special handling — while embedding`scribe-prompt` annotations that guide the LLM through non-trivial cases such as statement-function-to-lambda conversions and `extern "C"` wrapper generation. Third, `code-scribe translate` applies project-specific TOML-based few-shot prompt templates and submits the composed prompt to a pluggable LLM backend (OpenAI, Anthropic, Argonne ARGO, any OpenAI-compatible endpoint, or local Hugging Face checkpoints), producing a C++ source file, a header, and a Fortran-C++ interface file for each translated routine so the codebase compiles and runs correctly throughout the migration. Beyond translation, CodeScribe includes a tool-using coding agent (`code-scribe agent`) with read, bash, edit, and write capabilities, and a bounded loop mode (`code-scribe loop`) that runs repeated stateless agent sessions over a task file with restricted tool access — enabling sustained, auditable software development workflows for broader scientific computing tasks.

Dhruv, Akash [Argonne National Laboratory (ANL), A↗

Crystallization kinetics and thermodynamics of an Ag–In–Sb–Te phase change material using complementary in situ microscopic techniques

The crystallization of an amorphous Ag–In–Sb–Te (AIST) phase change material (PCM) is studied using multiple in situ imaging techniques to directly quantify crystal growth rates over a broad range of temperatures. The measurable growth rates span from ≈ 10 –9 to ≈ 20 m/s. Recent results using dynamic transmission electron microscopy (TEM), a photoemission TEM technique, and TEM with sub-framed imaging are reported here and placed into the context of previous growth rate measurements on AIST. Dynamic TEM experiments show a maximum observed crystal growth rate for as-deposited films to be > 20 m/s. It is shown that crystal growth above the glass transition can be imaged in a TEM through use of subframing and a high-frame-rate direct electron detection camera. Challenges associated with the determination of temperature during in situ TEM experiments are described. Finally, preliminary nanocalorimetry results demonstrate the feasibility of collecting thermodynamic data for crystallization of PCMs with simultaneous TEM imaging.

36 MATERIALS SCIENCE↗

Cervical SPECT Camera for Parathyroid Imaging

Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of the 56 MHz superconducting RF cavity in RHIC during run 14

A 56 MHz superconducting RF cavity was designed and installed in the Relativistic Heavy Ion Collider (RHIC). It is the first superconducting quarter wave resonator (QWR) operating in a high-energy storage ring. We discuss herein the cavity operation with Au+Au collisions, and with asymmetrical Au+He3 collisions. The cavity is a storage cavity, meaning that it becomes active only at the energy of experiment, after the acceleration cycle is completed. With the cavity at 300 kV, an improvement in luminosity was detected from direct measurements, and the bunch length has been reduced. The uniqueness of the QWR demands an innovative design of the higher order mode dampers with high-pass filters, and a distinctive fundamental mode damper that enables the cavity to be bypassed during the acceleration stage.

43 PARTICLE ACCELERATORS↗

Report on Research in Experimental High Energy Physics

In the past three years the groups supported by the DOE have all made significant progress and posted major successes. The Minnesota CMS group has played leading roles in five data analyses and has had major roles in detector operations, the data management and the detector upgrades that are planned for for the LHC and those that are planned for the high-luminosity LHC. The CDMS-II experiment held the lead in WIMP sensitivity over the last decade, and is still the most sensitive detector in the world in the low WIMP mass region, with a recent 3σ hint of 8 GeV/c 2 WIMP candidates in the silicon data. SuperCDMS, with three orders of magnitude better electron recoil background rejection, has been collecting data since October 2011. Since all dark matter experiments require a better understanding of neutron backgrounds to make further advances in sensitivity, Cushman has expanded the Minnesota effort on backgrounds to the national level, where she is leading a coordinated effort in neutron simulations for underground physics. The work of Mandic on 100 mm detectors both for Super-CDMS and beyond has advanced rapidly. Also at the Intensity Frontier, the BESIII experiment has had a successful year of operation largely focused on searches for and studies of new "charmonium-like" states above DD threshold. At least one new state has been observed so far, with hints of others. An intensive effort to understand their nature and gain new insight into the strong interaction continues. BESIII has also produced a large number of other results in charmonium decay and light-hadronic physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.

47 OTHER INSTRUMENTATION↗

Negative Ion Drift Time Projection Chamber Development for High-Resolution Tracking

Gas Time Projection Chambers (TPCs) are used extensively in High Energy Physics. Modern micro-pattern gaseous detectors (MPGDs) have made it feasible to construct large-volume TPCs with high readout granularity, so that ionization can be imaged with spatial resolution of order 100 μm or better. A challenge with large TPCs is preserving the track geometry over large drift distances. The reduced diffusion offered by negative ion drift (NID) has long been considered a possible means to scaling up TPCs at reduced cost, but NID has up to now required toxic and often flammable multi-component gas mixtures. A number of recent breakthroughs in the field have, however, led to a resurgence of interest in NID gas TPCs: First, it was found that multiple charge carriers in NID can be utilized to measure the absolute position of primary ionization in the drift direction, yielding a powerful new handle on backgrounds, at zero additional cost. Second, work by one of the PIs has revealed SF6 gas to be a non-toxic, non-flammable, NID gas with suitable minority charge carriers present. Third, preliminary work by the PIs suggests that multiple MPGD technologies work well with SF6. This opens the door to a new generation of large, high-resolution, low-background, low-cost gas TPCs. In this work we will investigate MPGD charge multiplication and charge readout in NID TPCs with SF6 gas. The objectives are to quantify the improvement over electron drift TPCs, and to identify the optimal MPGD types, operational parameters, electronics, and vacuum technologies for future low-background experiments. We will measure low-level detector performance parameters such as gain, gain resolution, and spatial resolution, as well as the resulting higher-level performance parameters such nuclear recoil identification efficiency, gamma-ray background rejection, track angle resolution and recoil energy resolution. The proposed work also includes investigation of acrylic vacuum vessels and collaboration on dedicated charge readout chips, both required for next-generation NID MPGD TPCs. MGPD NID TPCs may prove transformative for applications which require both high readout granularity and large detector volumes, such as the reconstruction of nuclear recoils in the context of large-scale directional dark matter searches, measurements of coherent neutrino-nucleus scattering, and directional neutron detection. While the proposed work is focused on nuclear recoils, the lessons learned will be widely applicable to gas TPCs in HEP, and hence have broad impact.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effective ZDC cross section measurement during a dedicated STAR elastic scattering physics store in Run15

At RHIC the collision rate per IP is monitored by the Zero Degree Calorimeters (ZDC) during most runs. Neutral particles produced in the collisions in the forward direction are detected in the ZDC and the collision rate corresponds to the rate of mutual neutrons above a variable threshold and within a certain coincidence window. Due to potential changes in the detector setup, con guration and electronics the ZDCs are calibrated every year by the use of vernier scans. At the end of the RHIC pp run in 2015 a dedicated run for the STAR elastic scattering physics program (PP2PP) was scheduled during which a total of 3 vernier scans was performed within the same store. This note presents the data and summarizes the results, i.e. effective ZDC cross section and the associated systematic errors from those scans.

43 PARTICLE ACCELERATORS↗

Particle Theory and Cosmology

This project covered theoretical studies in particle physics, particle astrophysics and cosmology, aiming to bridge theoretical models with observable phenomena. The central focus was on exploring innovative mechanisms that could simultaneously address several outstanding puzzles in these areas, including the nature of dark matter, the muon g-2 anomaly, the existence of topologically stable monopoles, the generation of observable gravitational waves from early universe phenomena and high energy cosmic rays. One of the major achievements of this project was the development of models that predict new physics accessible through current and forthcoming experimental setups, both in particle colliders and astrophysical observations. These models have been instrumental in proposing verifiable predictions concerning supersymmetric extensions, the dynamics of cosmic strings and monopoles, and the intricate processes underpinning baryogenesis and reheating post-inflation. In tackling the dark matter conundrum, the project proposed several candidates within extended frameworks, such as light Z' models, pseudo-Goldstone dark matter, and scenarios integrating dark matter with inflationary cosmology. Each model outlined pathways for detection through direct, indirect, and collider search strategies, marking significant strides in the hunt for dark matter. Another cornerstone of the project was the in-depth analysis of inflationary models compliant with the Trans-Planckian Censorship Conjecture, highlighting the compatibility of axion dark matter within such frameworks. This not only provided a coherent picture of early universe cosmology but also delineated clear experimental signatures. The exploration of grand unified theories yielded insights into the potential discovery of monopoles and novel particle configurations at energy scales accessible to current and future colliders. This endeavor expanded the predictive power of these theories, particularly in the context of proton decay and the properties of Higgs-portal dark matter. Throughout the project, significant emphasis was placed on ensuring the theoretical developments were grounded in experimental testability. This led to a series of publications across prestigious journals, each contributing to the vibrant discourse at the intersection of particle physics and cosmology. In summary, this project has elucidated pathways beyond the Standard Model that are ripe for exploration through both ongoing and upcoming experimental efforts. The comprehensive approach adopted herein not only enhances our understanding of the fundamental forces and constituents of the universe but also propels the field towards new frontiers in high-energy physics and cosmology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Physical Security Modeling and Simulation in the Vulnerability Assessment Process

This report provides a comprehensive assessment of physical security modeling and simulation tools available for use in the vulnerability assessment (VA) process for nuclear facilities. It outlines the historical evolution of VA methodologies, emphasizing the transition from traditional layer-based approaches to a more holistic framework that integrates detection probabilities directly into combat simulations. The document details the critical components of the VA process, including the characterization of targets, threats, and protective measures, as well as the development of adversary scenarios that reflect both insider and outsider threats. It highlights the importance of performance assurance programs, emphasizing the need for continuous evaluation and testing of security systems to ensure their effectiveness against evolving threats. Additionally, the report discusses the significance of utilizing accredited modeling and simulation tools in accredited areas to accurately represent adversary actions and the corresponding responses of protective forces. By establishing a systematic approach to VA, this document aims to enhance the overall security posture of nuclear facilities, ensuring compliance with regulatory standards while effectively mitigating risks associated with potential adversarial actions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A review of NEST models for liquid xenon and an exhaustive comparison with other approaches

This paper discusses the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describes experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique (NEST), a toolkit based on experimental data and simple empirical formulas, which mimic previous microphysics modeling but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field are reviewed, along with models for energy resolution and final pulse areas. NEST is compared with other models or sets of models and validated against real data, with several specific examples drawn from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.

WIMPs↗

Continuous MOF Membrane-Based Sensors via Functionalization of Interdigitated Electrodes

Three M-MOF-74 (M = Co, Mg, Ni) metal-organic framework (MOF) thin film membranes have been synthesized through a sensor functionalization method for the direct electrical detection of NO 2 . The two-step surface functionalization procedure on the glass/Pt interdigitated electrodes resulted in a terminal carboxylate group, with both steps confirmed through infrared spectroscopic analysis. This surface functionalization allowed the MOF materials to grow largely in a uniform manner over the surface of the electrode forming a thin film membrane over the Pt sensing electrodes. The growth of each membrane was confirmed through scanning electron microscopy (SEM) and X-ray diffraction analysis. The Ni and Mg MOFs grew as a continuous but non-defect free membrane with overlapping polycrystallites across the glass surface, whereas the Co-MOF-74 grew discontinuously. To demonstrate the use of these MOF membranes as an NO 2 gas sensor, Ni-MOF-74 was chosen as it was consistently fabricated as the best thin and homogenous membrane, as confirmed by SEM. The membrane was exposed to 5 ppm NO 2 and the impedance magnitude was observed to decrease 123× in 4 h, with a larger change in impedance and a faster response than the bulk material. Importantly, the use of these membranes as a sensor for NO 2 does not require them to be defect-free, but solely continuous and overlapping growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗