Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.

Crystal lattices↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Method for remote diagnostics of the internal structure of layered media

The method of autocorrelation low coherence interferometry is proposed for diagnostics of inhomogeneities and the internal structure of layered technical and biological samples. In this method the low coherence optical field reflected from the layered sample is analysed by using a Michelson interferometer. Because the object is outside the interferometer, the distance between the interferometer and the object under study is not limited and thus the object can move during the measurements. Theoretical substantiation of the autocorrelation method for media with discrete and continuous optical structure modifications is presented. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics of pigmented skin tumors based on laser-induced autofluorescence and diffuse reflectance spectroscopy

Results of investigation of cutaneous benign and malignant pigmented lesions by laser-induced autofluorescence spectroscopy (LIAFS) and diffuse reflectance spectroscopy (DRS) are presented. The autofluorescence of human skin was excited by a 337-nm nitrogen laser. A broadband halogen lamp (400-900 nm) was used for diffuse reflectance measurements. A microspectrometer detected in vivo the fluorescence and reflectance signals from human skin. The main spectral features of benign (dermal nevi, compound nevi, dysplastic nevi) and malignant (melanoma) lesions are discussed. The combined usage of the fluorescence and reflectance spectral methods to determine the type of the lesion, which increases the total diagnostic accuracy, is compared with the usage of LIAFS or DRS only. We also applied colorimetric transformation of the reflectance spectra detected and received additional evaluation criteria for determination of type of the lesion under study. Spectra from healthy skin areas near the lesion were detected and changes between healthy and lesion skin spectra were revealed. The influence of the main skin pigments on the detected spectra is discussed and evaluation of possibilities for differentiation between malignant and benign lesions is performed based on their spectral properties. This research shows that the non-invasive and high-sensitive in vivo detection by means of appropriate light sources and detectors should be possible, related to the real-time determination of existing pathological conditions. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy of nanoparticles based on Gd{sub 14}B{sub 6}Ge{sub 2}O{sub 34} polycrystals and La{sub 2}O{sub 3} - B{sub 2}O{sub 3} glasses, activated by Nd{sup 3+} ions, for cancer diagnostics

Nanoparticles of gadolinium borate polycrystals and borate glasses, activated by Nd3+ ions, are obtained from macroscopic samples of the corresponding compositions by mechanical grinding and ultrasonic dispersion in water. A spectroscopic study of these nanoparticles in the near-IR region is performed to determine their potential as luminescence biosensors and radiopharmaceutical preparations for cancer diagnostics by radiosensitive methods. A twofold increase in the lifetime of the metastable {sup 4}F{sub 3/2} state of Nd{sup 3+} ions at the transition from submicron polycrystalline particles to nanoparticles is experimentally found. A study of the nanoparticle distribution over organs and tissues of laboratory animals, performed with a 810-nm laser for exciting luminescence and a multichannel fibre spectrometer for measuring fluorescence in the range of 0.8 - 1.2 mm, showed this technique to be sufficiently sensitive to reliably determine the nanoparticle concentration in biological tissues and the dynamics of its change. (application of lasers and laser-optical methods in life sciences)

36 MATERIALS SCIENCE↗

Diagnostics of optical anisotropy changesin biological tissues using Mueller matrix

We study the efficiency of Mueller matrix diagnostics of birefringence in biological tissue layers with different optical thickness by measuring a set of third- and fourth-order statistical moments, characterising the coordinate distributions of the matrix element Z{sub 44} at different points of the histological section. (laser applications and other problems in quantum electronics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical diagnostics of biological tissue cells during their cultivation in polymers

The specific features of long-term luminescence of exogenous molecular probes in cells of pathogenic and normal biological tissues, cultivated on a solid nutrient medium, have been investigated by laser kinetic fluorimetry. It is proposed to use the Hyamatrix biopolymer as a nutrient medium. This polymer is formed on the basis of native, chemically unmodified hyaluronic acid and contains amino acids, microelements, vitamins, and other components. The possibility of using the obtained results to develop an alternative method of fluorescent diagnostics of biological tissues is discussed. (optical technologies in biophysics and medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CARS diagnostics of the burning of H{sub 2} - O{sub 2} and CH{sub 4} - O{sub 2} mixtures at high temperatures and pressures

Coherent anti-Stokes Raman scattering (CARS) spectroscopy is used to determine the parameters of gaseous combustion products of hydrogen and hydrocarbon fuels with oxygen at high temperatures and pressures. The methodical aspects of CARS thermometry, which are related to the optimal choice of molecules (diagnostic references) and specific features of their spectra, dependent on temperature and pressure, are analysed. Burning is modelled under the conditions similar to those of real spacecraft propulsion systems using a specially designed laboratory combustion chamber, operating in the pulse-periodic regime at high temperatures (to 3500 K) and pressures (to 20 MPa) of combustion products. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptation of LASCA method for diagnostics of malignant tumours in laboratory animals

The LASCA method is adapted for diagnostics of malignant neoplasms in laboratory animals. Tumours are studied in mice of Balb/c inbred line after inoculation of cells of syngeneic myeloma cell line Sp.2/0 Ag.8. The appropriateness of using the tLASCA method in tumour investigations is substantiated; its advantages in comparison with the sLASCA method are demonstrated. It is found that the most informative characteristic, indicating the presence of a tumour, is the fractal dimension of LASCA images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial-frequency Fourier polarimetry of the complex degree of mutual anisotropy of linear and circular birefringence in the diagnostics of oncological changes in morphological structure of biological tissues

Theory of polarisation-correlation analysis of laser images of histological sections of biopsy material from cervix tissue based on spatial frequency selection of linear and circular birefringence mechanisms is formulated. Comparative results of measuring the coordinate distributions of the complex degree of mutual anisotropy (CDMA), produced by fibrillar networks formed by myosin and collagen fibres of cervix tissue in different pathological conditions, namely, pre-cancer (dysplasia) and cancer (adenocarcinoma), are presented. The values and variation ranges of statistical (moments of the first - fourth order), correlation (excess-autocorrelation functions), and fractal (slopes of approximating curves and dispersion of extrema of logarithmic dependences of power spectra) parameters of the CDMA coordinate distributions are studied. Objective criteria for pathology diagnostics and differentiation of its severity degree are determined. (image processing)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical diagnostics of tumour cells at different stages of pathology development

The differences in optical and biophysical properties between the cells of mammary gland tumour extracted from tumours of different diameter are described. It is shown that the spectral and spectrokinetic properties of fluorescent probes in the cells extracted from the tumours 1 – 3 cm in diameter are essentially different. Thus, the extinction coefficient of rhodamine 6G gradually increases with the pathology development. At the same time the rate of interaction of the triplet states of molecular probes with the oxygen, diluted in the tumour cells cytoplasm, decreases with the growth of the tumour capsule diameter. The observed regularities can be due to the changes in the cell structure, biochemical and biophysical properties. The reported data may be useful for developing optical methods of diagnostics of biotissue pathological conditions. (optical methods in biology and medicine)

60 APPLIED LIFE SCIENCES↗

Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recording the synchrotron radiation by a picosecond streak camera for bunch diagnostics in cyclic accelerators

A PS-1/S1 picosecond streak camera with a linear sweep is used to measure temporal characteristics of synchrotron radiation pulses on a damping ring (DR) at the Budker Institute of Nuclear Physics (BINP) of the Siberian Branch of the Russian Academy of Sciences (Novosibirsk). The data obtained allow a conclusion as to the formation processes of electron bunches and their 'quality' in the DR after injection from the linear accelerator. The expediency of employing the streak camera as a part of an optical diagnostic accelerator complex for adjusting the injection from a linear accelerator is shown. Discussed is the issue of designing a new-generation dissector with a time resolution up to a few picoseconds, which would allow implementation of a continuous bunch monitoring in the DR during mutual work with the electron-positron colliders at the BINP. (acoustooptics)

43 PARTICLE ACCELERATORS↗

Accounting for the instrument function of crystal spectrometers operating in many reflection orders in the diagnostics of laser plasma from its continuum spectrum

By the example of an X-ray spectrometer with a spherically bent mica crystal we consider the diagnostic errors entailed when the observed bremsstrahlung spectrum is attributed to a single spectrum of reflection. As an illustration we choose the X-ray emission spectrum of the plasma produced at the surface of a steel foil by femtosecond laser pulses of relativistic intensity. It is shown that obtaining adequate results in the case of a high-temperature plasma calls for the consistent inclusion of all orders of reflection or diffraction with a dispersing device. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New approach to terahertz diagnostics of human psychoemotional state

A new approach to terahertz (THz) diagnostics of the human psychoemotional state is proposed, based on the analysis of the THz contribution to the total signal while simultaneously recording the IR and THz emissions from the human body (hereinafter referred to as the IR – THz image). The developed image-processing algorithm allows extraction of the informative contribution determined by the THz radiation from the total signal perceived by the recording system. Simultaneous registration of the IR – THz images of the human face and the psychophysiological indicators are carried out in situations of physical stress (short-term intense physical exercise – squats functional test), electrical stimulation, and information stress (cognitive load – simple arithmetic mental calculations). The obtained data are compared with those of similar measurements at rest. It is shown that using cluster analysis of IR – THz images it is possible to divide the test subjects into classes according to the type of reaction of the circulatory system under stressful conditions. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Versitile X-ray diagnostics of laser-produced high-temperature plasmas using an ultra-high luminosity spectrometer

Versitile diagnostics of high-temperature magnesium laser-produced plasmas is performed using an ultra-high luminosity X-ray focusing crystal spectrometer. The plasmas are produced by focusing nanosecond laser pulses (0.53 μm, 1 J, 2 ns) on a massive magnesium target. The absolute intensities and X-ray yields are measured for the resonance lines of H- and He-like ions (spectral range: Δλ = 8 –10 Å), the electron temperature of plasmas is determined (range: T{sub e} = 200 – 550 eV), and the behaviour of these parameters is established in a broad range of laser pulse energy E{sub L} (10 mJ – 1 J). This approach permits the parameters of laser-plasma radiation sources to be monitored in real time in a wide intensity range (difference in intensity: over 10{sup 4}) and in a broad range of plasma parameters. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A SPECTROSCOPIC EXAMINATION OF ACCRETION DIAGNOSTICS FOR NEAR SOLAR MASS STARS IN IC 348

High-resolution optical and moderate-resolution near-infrared spectra were obtained for 40 near solar mass ({approx}2.0-0.5 M{sub sun}) members of the 2-3 Myr old cluster IC 348 in order to examine established accretion diagnostics and the coupling between inner disk gas and hot, micron-sized dust grains inferred from thermal and mid-infrared excesses. The stellar sample was drawn from the cluster census of Luhman in 2003 with membership being confirmed by radial velocity analysis and the presence of strong Li I {lambda}6708 absorption. Of the stars included in this survey, 12 were classified by Lada in 2006 as hosting primordial, optically thick circumstellar disks, 5 as weak or transition disk systems, and 23 as non-excess stars using the measured slope of the stellar spectral energy distribution (SED) through the four Infrared Array Camera channels (3.6-8.0 {mu}m) of Spitzer Space Telescope. Using the velocity width of H{alpha} as an accretion indicator, we find that 11 primordial disk candidates are suspected accretors, suggesting a strong correlation between gaseous inner disks and optically thick dust emission. Of the five weak or transition disk systems observed, two (L21 and L67) exhibit spectroscopic features indicative of accretion. The presence of gas within the inner disk of these systems, which are free of infrared excess emission shortward of {approx}4.5 {mu}m, may place constraints upon the physical mechanism responsible for inner disk clearing. Mass accretion rates ( M-dot ) were determined for all suspected accretors using continuum excess measurements near {lambda}6500 and established relationships between He I {lambda}5876, H{alpha}, Ca II {lambda}8542, Pa{beta}, and Br{gamma} line fluxes and accretion luminosity. M-dot values were found to range from log M-dot = -8.7 to -7.2 M{sub sun} yr{sup -1}, with a median value of -8.1 M{sub sun} yr{sup -1}. Magnetospheric accretion models of H{alpha}, Pa{beta}, and Br{gamma} emission by Muzerolle et al. and Kurosawa et al. are found to be in relative agreement with observed fluxes and derived M-dot estimates. He I {lambda}10830 with its metastable lower level is confirmed to be a critical indicator of magnetospheric accretion, although deep subcontinuum absorption profiles often associated with its emission are not fully understood. No statistically significant correlation is found between M-dot and the slope of the SED from 3.6 to 8.0 {mu}m or from 8.0 to 24.0 {mu}m; however, the small number of suspected accretors examined does not allow broader conclusions to be drawn.

79 ASTRONOMY AND ASTROPHYSICS↗