Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Development assurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

A Methodology to Evaluate Ecological Resources and Risk Using Two Case Studies at the Department of Energy’s Hanford Site

An assessment of the potential risks to ecological resources from remediation activities or other perturbations should involve a quantitative evaluation of resources on the remediation site and in the surrounding environment. We developed a risk methodology to rapidly evaluate potential impact on ecological resources for the U.S. Department of Energy’s Hanford Site in southcentral Washington State. We describe the application of the risk evaluation for two case studies to illustrate its applicability. The ecological assessment involves examining previous sources of information for the site, defining different resource levels from 0 to 5. We also developed a risk rating scale from nondiscernable to very high. Field assessment is the critical step to determine resource levels or to determine if current conditions are the same as previously evaluated. We provide a rapid assessment method for current ecological conditions that can be compared to previous site-specific data, or that can be used to assess resource value on other sites where ecological information is not generally available. The method is applicable to other Department of Energy’s sites, where its development may involve a range of state regulators, resource trustees, Tribes and other stakeholders. Achieving consistency across Department of Energy’s sites for valuation of ecological resources on remediation sites will assure Congress and the public that funds and personnel are being deployed appropriately.

54 ENVIRONMENTAL SCIENCES↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

FAST-1.0 Software Release Document

The purpose of this document is to detail the release of FAST-1.0 and the documents that accompany the development and testing of FAST-1.0. Design requirements were for FAST-1.0 developed in the NRC Statement of Work (SOW) for NRC Agreement Number NRC-HQ-25-14-D-001 and are transcribed to this document as part of the Software Quality Assurance Plan for the FAST Code System, PNNL-28767. FAST 1.0 represents the merger of the FRAPCON and FRAPTRAN codes and as such FAST-1.0 performs steady state and transient fuel performance calculations described below. FAST-1.0 calculates the steady state response of light-water reactor fuel rods during long-term burnup. The code calculates temperature, pressure, and deformation of a fuel rod as functions of time-dependent fuel rod power and coolant boundary conditions. The phenomena modeled by the code include: 1) heat conduction through fuel and cladding to the coolant; 2) cladding elastic and plastic deformation; 3) fuel-cladding mechanical interaction; 4) fission gas release from the fuel and rod internal pressure; and 5) cladding oxidation. FAST is used to perform independent calculations for regulatory evaluations of fuel performance under normal operation and anticipated operational occurrences (AOOs).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Self-Aware Local Autonomous and Semi-Cooperative Control for Cross-Layered Resilience (SLAC3R)

The objective of this work is to develop and demonstrate novel, adaptive, lightweight algorithms that enable the decision-making agents in a large cyber-physical network to act both autonomously and in collaborative harmony to enforce assured resilience across spatiotemporal layers, even under unforeseen adversarial scenarios (e.g., high- impact-low-probability events). Towards this end, the proposed solution will serve as minimally invasive add-on layers that bridge the existing (faster, reactive) local myopic controls and (slower, predictive) centralized optimization. Importantly, the proposed algorithms will enable the multi-agent network to autonomously and collaboratively enforce resilient operation under no or limited communication environment typical of severe cyber- physical adversarial events. The expected outcome of this effort is a suite of prototype, open-source, software algorithms for safety-aware local autonomous and semi-cooperative control (SLAC3R), demonstrated on networked microgrids (via RD2C/Thrust-1 OPAL-RT testbed).

97 MATHEMATICS AND COMPUTING↗

A CCD tracker for closed-loop instrument pointing at Halley's comet

An optical tracker based on CCD technology has been developed for the closed-loop pointing of the narrow-angle imaging system of the proposed Halley's comet intercept mission at the comet nucleus. The target tracker, needed to assure the accurate pointing of science instruments as the nucleus rapidly passes the spacecraft, is a component of the pointing control system, which also includes a two-axis articulated instrument platform and high-resolution optical encoders to measure platform orientation relative to spacecraft structure. The device was designed on the basis of a CCD imaging array to calculate target centroid position based on the optical intensity of all pixels containing the image, and a processor to perform spacecraft attitude control, pointing control and target tracker control and data processing functions. The tracker has been configured to operate in both target acquisition and tracking modes. Preliminary simulation results and past experiments on similar trackers indicate that excellent tracking performance can be achieved, and a breadboard version of the tracker is currently being fabricated.

Stanton, R. H.↗

The software product assurance metrics study: JPL's software systems quality and productivity

The findings are reported of the Jet Propulsion Laboratory (JPL)/Software Product Assurance (SPA) Metrics Study, conducted as part of a larger JPL effort to improve software quality and productivity. Until recently, no comprehensive data had been assembled on how JPL manages and develops software-intensive systems. The first objective was to collect data on software development from as many projects and for as many years as possible. Results from five projects are discussed. These results reflect 15 years of JPL software development, representing over 100 data points (systems and subsystems), over a third of a billion dollars, over four million lines of code and 28,000 person months. Analysis of this data provides a benchmark for gauging the effectiveness of past, present and future software development work. In addition, the study is meant to encourage projects to record existing metrics data and to gather future data. The SPA long term goal is to integrate the collection of historical data and ongoing project data with future project estimations.

Bush, Marilyn W.↗

Advances in photographic X-ray imaging for solar astronomy

The technique of obtaining quantitative data from high resolution soft X-ray photographic images produced by grazing incidence optics was successfully developed to a high degree during the Solar Research Sounding Rocket Program and the S-054 X-Ray Spectrographic Telescope Experiment Program on Skylab. Continued use of soft X-ray photographic imaging in sounding rocket flights of the High Resolution Solar Soft X-Ray Imaging Payload has provided opportunities to further develop these techniques. The developments discussed include: (1) The calibration and use of an inexpensive, commercially available microprocessor controlled drum type film processor for photometric film development; (2) The use of Kodak Technical Pan 2415 film and Kodak SO-253 High Speed Holographic film for improved resolution; and (3) The application of a technique described by Cook, Ewing, and Sutton for determining the film characteristics curves from density histograms of the flight film. Although the superior sensitivity, noise level, and linearity of microchannel plate and CCD detectors attracts the development efforts of many groups working in soft X-ray imaging, the high spatial resolution and dynamic range as well as the reliability and ease of application of photographic media assures the continued use of these techniques in solar X-ray astronomy observations.

Moses, J. Daniel↗

Advances in photographic X-ray imaging for solar astronomy

The technique of obtaining quantitative data from high resolution soft X-ray photographic images produced by grazing incidence optics was successfully developed to a high degree during the AS&E Solar Research Sounding Rocket Program and the S-054 X-Ray Spectrographic Telescope Experiment Program on Skylab. Continued use of soft X-Ray photographic imaging in sounding rocket flights of the AS&E High Resolution Solar Soft X-Ray Imaging Payload has provided opportunities to further develop these techniques. The developments discussed include: (1) the calibration and use of an inexpensive, commercially available microprocessor controlled drum type film processor for photometric film development, (2) the use of Kodak Technical Pan 2415 film and Kodak SO-253 High Speed Holographic film for improved resolution, and (3) the application of a technique described by Cook, Ewing, and Sutton (1988) for determining the film characteristics curves from density histograms of the flight film. Although the superior sensitivity, noise level, and linearity of microchannel plate and CCD detectors attracts the development efforts of many groups working in soft X-ray imaging, the high spatial resolution and dynamic range as well as the reliability and ease of application of photographic media assures the continued use of these techniques in solar X-ray astronomy observations.

Moses, D.↗

Holographic testing of composite propfans for a cruise missile wind tunnel model

Each of the approximately 90 composite propfan blades constructed for a 55 percent scale cruise missile wind tunnel model were holographically tested to obtain natural frequencies and mode shapes. These data were used not only for quality assurance, but also to select sets of similar blades for each blade row. Presented along with the natural frequency data is a description of a computer-based image processing system developed to supplement the photographic based system for holographic image analysis and storage. The new system is quicker and cheaper, the holograms are indexed better, and several engineers can access the data simultaneously. The only negative effect is a slight reduction in image resolution, which does not influence the end use.

Miller, Christopher J.↗

Design of a refueling tanker delivering liquid hydrogen

A refueling tanker that could deliver 155,000 lb of liquid hydrogen to a hypersonic tanker in 15 min was designed. A flying boom system was chosen to fit strict delivery criteria. Tank design and material specification were also addressed. To assure the flow required, it was important to cancel the pressure drop phenomenon. Geometry, aerodynamics, weight considerations, propulsion, stability, and performance for the tanker were also considered. Finally, the cost of developing three prototypes was estimated.

Lourme, Daniel↗

Convective Weather Avoidance with Uncertain Weather Forecasts

Convective weather events have a disruptive impact on air traffic both in terminal area and in en-route airspaces. In order to make sure that the national air transportation system is safe and efficient, it is essential to respond to convective weather events effectively. Traffic flow control initiatives in response to convective weather include ground delay, airborne delay, miles-in-trail restrictions as well as tactical and strategic rerouting. The rerouting initiatives can potentially increase traffic density and complexity in regions neighboring the convective weather activity. There is a need to perform rerouting in an intelligent and efficient way such that the disruptive effects of rerouting are minimized. An important area of research is to study the interaction of in-flight rerouting with traffic congestion or complexity and developing methods that quantitatively measure this interaction. Furthermore, it is necessary to find rerouting solutions that account for uncertainties in weather forecasts. These are important steps toward managing complexity during rerouting operations, and the paper is motivated by these research questions. An automated system is developed for rerouting air traffic in order to avoid convective weather regions during the 20- minute - 2-hour time horizon. Such a system is envisioned to work in concert with separation assurance (0 - 20-minute time horizon), and longer term air traffic management (2-hours and beyond) to provide a more comprehensive solution to complexity and safety management. In this study, weather is dynamic and uncertain; it is represented as regions of airspace that pilots are likely to avoid. Algorithms are implemented in an air traffic simulation environment to support the research study. The algorithms used are deterministic but periodically revise reroutes to account for weather forecast updates. In contrast to previous studies, in this study convective weather is represented as regions of airspace that pilots are likely to avoid. The automated system periodically updates forecasts and reassesses rerouting decisions in order to account for changing weather predictions. The main objectives are to reroute flights to avoid convective weather regions and determine the resulting complexity due to rerouting. The eventual goal is to control and reduce complexity while rerouting flights during the 20 minute - 2 hour planning period. A three-hour simulation is conducted using 4800 flights in the national airspace. The study compares several metrics against a baseline scenario using the same traffic and weather but with rerouting disabled. The results show that rerouting can have a negative impact on congestion in some sectors, as expected. The rerouting system provides accurate measurements of the resulting complexity in the congested sectors. Furthermore, although rerouting is performed only in the 20-minute - 2-hour range, it results in a 30% reduction in encounters with nowcast weather polygons (100% being the ideal for perfectly predictable and accurate weather). In the simulations, rerouting was performed for the 20-minute - 2-hour flight time horizon, and for the en-route segment of air traffic. The implementation uses CWAM, a set of polygons that represent probabilities of pilot deviation around weather. The algorithms were implemented in a software-based air traffic simulation system. Initial results of the system's performance and effectiveness were encouraging. Simulation results showed that when flights were rerouted in the 20-minute - 2-hour flight time horizon of air traffic, there were fewer weather encounters in the first 20 minutes than for flights that were not rerouted. Some preliminary results were also obtained that showed that rerouting will also increase complexity. More simulations will be conducted in order to report conclusive results on the effects of rerouting on complexity. Thus, the use of the 20-minute - 2-hour flight time horizon weather avoidance teniques performed in the simulation is expected to provide benefits for short-term weather avoidance.

Karahan, Sinan↗

Structural Dynamics Modeling of HIRENASD in Support of the Aeroelastic Prediction Workshop

An Aeroelastic Prediction Workshop (AePW) was held in April 2012 using three aeroelasticity case study wind tunnel tests for assessing the capabilities of various codes in making aeroelasticity predictions. One of these case studies was known as the HIRENASD model that was tested in the European Transonic Wind Tunnel (ETW). This paper summarizes the development of a standardized enhanced analytical HIRENASD structural model for use in the AePW effort. The modifications to the HIRENASD finite element model were validated by comparing modal frequencies, evaluating modal assurance criteria, comparing leading edge, trailing edge and twist of the wing with experiment and by performing steady and unsteady CFD analyses for one of the test conditions on the same grid, and identical processing of results.

Wieseman, Carol↗

Validating an Air Traffic Management Concept of Operation Using Statistical Modeling

Validating a concept of operation for a complex, safety-critical system (like the National Airspace System) is challenging because of the high dimensionality of the controllable parameters and the infinite number of states of the system. In this paper, we use statistical modeling techniques to explore the behavior of a conflict detection and resolution algorithm designed for the terminal airspace. These techniques predict the robustness of the system simulation to both nominal and off-nominal behaviors within the overall airspace. They also can be used to evaluate the output of the simulation against recorded airspace data. Additionally, the techniques carry with them a mathematical value of the worth of each prediction-a statistical uncertainty for any robustness estimate. Uncertainty Quantification (UQ) is the process of quantitative characterization and ultimately a reduction of uncertainties in complex systems. UQ is important for understanding the influence of uncertainties on the behavior of a system and therefore is valuable for design, analysis, and verification and validation. In this paper, we apply advanced statistical modeling methodologies and techniques on an advanced air traffic management system, namely the Terminal Tactical Separation Assured Flight Environment (T-TSAFE). We show initial results for a parameter analysis and safety boundary (envelope) detection in the high-dimensional parameter space. For our boundary analysis, we developed a new sequential approach based upon the design of computer experiments, allowing us to incorporate knowledge from domain experts into our modeling and to determine the most likely boundary shapes and its parameters. We carried out the analysis on system parameters and describe an initial approach that will allow us to include time-series inputs, such as the radar track data, into the analysis

Statistical emulation↗

Assurance of Autonomy

This presentation gives an overview of the research directions taken by the System Wide Safety project (NASA ARMD) with respect to the assurance of autonomy to support certification of aviation systems for emerging markets. The talk gives an overview of the project and a quick overview of some of the research tools being developed at NASA Ames.

Brat, Guillaume↗

CFD modeling of debris melting phenomena during late phase Candu 6 severe accident

The objective of this paper was to study the phase change of the debris formed on the Candu 6 calandria bottom in a postulated accident sequence. The molten pool and crust formation were studied employing the Ansys-Fluent code. The 3D model using Large Eddy Simulation (LES) predicts the conjugate, radiative and convective heat transfer inside and from the corium pool. LES simulations require a very fine grid to capture the crust formation and the free convection flow. This aspect (fine mesh requirement) correlated with the long transient has imposed the use of a slice from the 3D calandria geometry in order not to exceed the computing resources. The preliminary results include heat transfer coefficients, temperature profiles and heat fluxes through calandria wall. From the safety point of view it is very important to maintain a heat flux through the wall below the CHF assuring the integrity of the calandria vessel. This can be achieved by proper cooling of the tank water which contains the vessel. Also, transient duration can be estimated being important in developing guidelines for severe accidents management. The debris physical structure and material properties have large uncertainties in the temperature range of interest. Thus, further sensitivity studies should be carried out in order to better understand the influence of these parameters on this complex phenomenon. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The NREL Sensor Laboratory: Hydrogen Leak Detection for Large Scale Deployments: Preprint

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for sensor developers, end-users, and regulatory agencies within the national and international hydrogen community. The Laboratory continues to provide as its core capability the unbiased verification of hydrogen sensor performance to assure sensor availability and their proper use. However, the mission and strategy of the NREL Sensor Laboratory has evolved to meet the needs of the growing hydrogen market. The Sensor Laboratory program has expanded to support research in conventional and alternative detection methods as hydrogen use expands to large-scale markets as envisioned by the DOE National Clean Hydrogen Strategy and Roadmap. Current research encompasses advanced methods of hydrogen leak detection including stand-off and wide area monitoring approaches for large scale and distributed applications. In addition to safety applications, low-level detection strategies to support the potential environmental impacts of hydrogen and hydrogen product losses along the value chain are being explored. Many of these applications utilize detection strategies that supplement and may supplant the use of traditional point sensors. The latest results of the hydrogen detection strategy research at NREL will be presented.

detection↗

Dosimetry protocol for the forthcoming clinical trials in synchrotron stereotactic radiation therapy (SSRT)

Purpose: An adequate dosimetry protocol for synchrotron radiation and the specific features of the ID17 Biomedical Beamline at the European Synchrotron Radiation Facility are essential for the preparation of the forthcoming clinical trials in the synchrotron stereotactic radiation therapy (SSRT). The main aim of this work is the definition of a suitable protocol based on standards of dose absorbed to water. It must allow measuring the absolute dose with an uncertainty within the recommended limits for patient treatment of 2%-5%. Methods: Absolute dosimetry is performed with a thimble ionization chamber (PTW semiflex 31002) whose center is positioned at 2 g cm{sup -2} equivalent depth in water. Since the available synchrotron beam at the ESRF Biomedical Beamline has a maximum height of 3 mm, a scanning method was employed to mimic a uniform exposition of the ionization chamber. The scanning method has been shown to be equivalent to a broad beam irradiation. Different correction factors have been assessed by using Monte Carlo simulations. Results: The absolute dose absorbed to water at 80 keV was measured in reference conditions with a 2% global uncertainty, within the recommended limits. The dose rate was determined to be in the range between 14 and 18 Gy/min, that is to say, a factor two to three times higher than the 6 Gy/min achievable in RapidArc or VMAT machines. The dose absorbed to water was also measured in a RW3 solid water phantom. This phantom is suitable for quality assurance purposes since less than 2% average difference with respect to the water phantom measurements was found. In addition, output factors were assessed for different field sizes. Conclusions: A dosimetry protocol adequate for the specific features of the SSRT technique has been developed. This protocol allows measuring the absolute dose absorbed to water with an accuracy of 2%. It is therefore satisfactory for patient treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Assurance for End-Item Users

The goal of a Quality Management System (QMS) as specified in ISO 9001 and AS9100 is to assure the end product meets specifications and customer requirements. Measuring devices, often called measuring and test equipments (MTE), provide the evidence of product conformity to the prescribed requirements. Therefore the processes which employ MTE can become a weak link to the overall QMS if proper attention is not given to development and execution of these processes. Traditionally, calibration of MTE is given more focus in industry standards and process control efforts than the equally important proper usage of the same equipment. It is a common complaint of calibration laboratory personnel that MTE users are only interested in "a sticker." If the QMS requires the MTE "to demonstrate conformity of the product," then the quality of the measurement process must be adequate for the task. This leads to an ad hoc definition; measurement assurance is a discipline that assures that all processes, activities, environments, standards, and procedures involved in making a measurement produce a result that can be rigorously evaluated for validity and accuracy. To evaluate that the existing measurement processes are providing an adequate level of quality to support the decisions based upon this measurement data, an understanding of measurement assurance basics is essential. This topic is complimentary to the calibration standard, ANSI/NCSL Z540.3-2006, which targets the calibration of MTE at the organizational level. This paper will discuss general measurement assurance when MTE is used to provide evidence of product conformity, therefore the target audience of this paper is end item users of MTE. A central focus of the paper will be the verification of tolerances and the associated risks, so calibration professionals may find the paper useful in communication with their customers, MTE users.

Mimbs, Scott M.↗