Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Systems and methods for global cyber-attack or fault detection model

An industrial asset may have monitoring nodes that generate current monitoring node values representing a current operation of the industrial asset. An abnormality detection computer may detect when a monitoring node is currently being attacked or experiencing a fault based on a current feature vector, calculated in accordance with current monitoring node values, and a detection model that includes a decision boundary. A model updater (e.g., a continuous learning model updater) may determine an update time-frame (e.g., short-term, mid-term, long-term, etc.) associated with the system based on trigger occurrence detection (e.g., associated with a time-based trigger, a performance-based trigger, an event-based trigger, etc.). The model updater may then update the detection model in accordance with the determined update time-frame (and, in some embodiments, continuous learning).

Xu, Rui↗

Self-Supervised Anomaly Detection via Neural Autoregressive Flows with Active Learning

Many self-supervised methods have been proposed with the target of image anomaly detection. These methods often rely on the paradigm of data augmentation with predefined transformations such as flipping, cropping, and rotations. However, it is not straightforward to apply these techniques for non-image data, such as time series or tabular data, while the performance of the existing deep approaches has been under our expectation on tasks beyond images. In this work, we propose a novel active learning (AL) scheme that relied on neural autoregressive flows (NAF) for self-supervised anomaly detection, specifically on small-scale data. Unlike other generative models such as GANs or VAEs, flow-based models allow to explicitly learn the probability density and thus can assign accurate likelihoods to normal data which makes it usable to detect anomalies. The proposed NAF-AL method is achieved by efficiently generating random samples from latent space and transforming them into feature space along with likelihoods via invertible mapping. The samples with lower likelihoods are selected and further checked by outlier detection using Mahalanobis distance. The augmented samples incorporating with normal samples are used for training a better detector so as to approach decision boundaries. Compared with random transformations, NAF-AL can be interpreted as a likelihood-oriented data augmentation that is more efficient and robust. Extensive experiments show that our approach outperforms existing baselines on multiple time series and tabular datasets, and a real-world application in advanced manufacturing, with significant improvement on anomaly detection accuracy and robustness over the state-of-the-art.

Zhang, Jiaxin↗

A statistical approach for detection of anatomical change - Paper 115

The purpose of this study was to develop a novel statistics-based method for automated detection of anatomical changes using cone-beam CT (CBCT) images of head and neck (H and N) patients. Vendor supplied CBCT software provides the user with the basic tools that allow for the visual assessment of the co-registration of the reference CT data and daily CBCT images. Currently there is no commercially available CBCT software that is capable of detecting anatomical changes and giving the clinician an early alert for the treatment plan adaptation. An algorithm was developed that can detect statistically significant changes at a given confidence level for H and N patients. This tool provides a reliable and automated early warning system that enables a 'just-in-time' adaptation of the treatment plan. A method was developed for automated detection of anatomical changes in H and N patients under radiation therapy treatment. The method utilized imaging CT data along with daily CBCT images to quantitatively compare the patient anatomy against the reference CT imaging data. The comparison algorithm was developed using a statistics-based approach as opposed to threshold-based methods. The algorithm allows for reliable detection of statistically significant changes in the observed patient anatomy at a given level of confidence. The method can be employed as an integral part of the adaptive radiotherapy framework. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Entanglement-Enhanced Neyman-Pearson Target Detection

Quantum illumination (QI) provides entanglement-enabled target-detection enhancement, despite operating in an entanglement-breaking environment. Existing experimental studies of QI have utilized a Bayesian approach, assuming that the target is equally likely to be present or absent before detection, to demonstrate an advantage over classical target detection. However, such a premise breaks down in practical operational scenarios in which the prior probability is unknown, thereby hindering QI's applicability to real-world target-detection scenarios. In this work, we adopt the Neyman-Pearson criterion in lieu of the error probability for equally likely target absence or presence as our figure of merit for QI. We demonstrate an unconditional quantum advantage over the optimal classical-illumination protocol as benchmarked by the receiver operating characteristic, which examines detection probability versus false-alarm probability without resorting to known prior probabilities. Our work represents a critical advancement in adapting quantum-enhanced sensing to practical operational settings.

Ward, William↗

System and method for neutron and gamma radiation detection using non-homogeneous material scintillator

The present disclosure relates to a method for detecting incoming radiation having a plurality of differing properties including at least one of differing types, differing energies or differing incoming directions. The method involves using a scintillator structure formed from first and second dissimilar scintillator materials, where the first and second dissimilar scintillator materials emit first and second different colors of light in response to the incoming radiation. A first light detector is used for detecting light having the first color, and a second light detector is used for detecting light having the second color. A first output signal is generated in response to the detection of light having the first color, and a second output signal is generated in response to detecting light having the second color. The first and second output signals are then analyzed to determine at least one property of the incoming radiation.

Brodsky, Jason Philip↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

Towards Content Authenticity: Multimodal Fake News Detection and AI-Generated Text Identification

In today’s digital world, the spread of fake news and the rise of AI-generated text have become major threats to content authenticity and public trust. This thesis addresses both challenges through two complementary research directions: detecting fake news using multimodal features, and identifying AI-generated text using semantic and structural reasoning. The first part of the work focuses on fake news detection by introducing a novel model that combines text and image features through a unique rotational attention mechanism. Unlike traditional attention methods, this approach rotates the roles of query, key, and value across modalities to capture deeper interactions. Additionally, the model incorporates external domain information by linking news posts to top-ranked websites from Google search results, which helps assess the credibility of content based on its broader web context. This results in a more reliable and accurate fake news detection system that outperforms existing state-of-the-art methods. The second part presents SGG-ATD, a new framework for detecting AI-generated text. It uses masked language modeling to measure sentence coherence, followed by constructing a graph where keywords—both original and predicted—are connected based on semantic and contextual similarity. A Graph Convolutional Network (GCN) is then used to learn structural relationships within the text for final classification. Experimental results demonstrate that SGG-ATD achieves high F1-scores and consistently outperforms strong baselines. This method contributes to robust AI text detection, supporting accountability and resilience against AI-driven misinformation.

Gupta, Nidhi↗

A Dynamic Hierarchical Attention Framework for Multimodal Malware Detection

The increasing use of Android in the worldwide mobile ecosystem has come along with a significant increase in advanced malware, highlighting the critical necessity for efficient, scalable, and adaptable detection systems. Despite recent advancements in machine learning improving malware detection, the majority of current solutions are limited to one, two, or three data modalities, hence neglecting the comprehensive behavioral spectrum of contemporary multi-vector threats. This thesis presents the first comprehensive multimodal framework for Android malware detection, which combines textual, time-series (temporal), graph-based (structural), and visual information using an innovative hierarchical attention mechanism and Dynamic Fusion Controller (DFC). Our methodology consistently classifies and processes modalities as either sequential or structural, facilitating content-adaptive weighting and resilient cross-modal representation learning. We advance the implementation of cutting-edge time series techniques, such as MiniRocket, for malware detection, hence creating new opportunities for temporal analysis in cybersecurity. Comprehensive experimental assessment shows that our framework performs exceptionally well, with 99.46% classification accuracy and 97.15% detection accuracy, significantly outperforming existing approaches through effective multimodal integration and hierarchical attention mechanisms.

Nazmin, Tamanna↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Detecting Unclassified Electromagnetic Signals for Secure Wireless Communication Using Open Set Recognition

We developed multiple machine learning methods for the detection and classification of new wireless communication waveforms, which is critical for targeted attacks in wireless networks and electronic warfare. Our machine learning models are capable of dynamically detecting security threats in near real time through our advanced open set recognition (OSR) approach. This model has demonstrated significant improvements in the detection of unknown waveforms, thereby enhancing the security and reliability of mission critical communications. Our approach to detecting uncertain security threats is novel; we advanced OSR techniques by incorporating domain knowledge of wireless signals. Specifically, we combined time and frequency domain model features to enhance the model’s performance. Utilizing an OSR approach eliminates the need for training data to be distributed similarly to the deployment environment and removes the requirement for the training set to contains all possible threat classes. This is crucial because it is often infeasible to determine and characterize all potential security threats in advance. Our model were trained on simulated data, generated in partnership with the University at Albany, State of New York. The data set contained a diverse array of wireless signals, including those with additive white Gaussian noise and multipath signals, with and without line of sight. This comprehensive training set allowed us to optimize our models to detect unknown waveforms under various challenging scenarios, such as low signal-to-noise ratios. By training on various waveforms, varying signal-to-noise ratio, and different sample sizes under normal conditions, our models were fine tuned to perform effectively in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Fissionable Material

Experiments have been performed at Idaho National Laboratory to study methodology and instrumentation for performing neutron active interrogation die-away analyses for the purpose of detecting shielded fissionable material. Here we report initial work using a portable DT electronic neutron generator with a He-3 fast neutron detector to detect shielded fissionable material including >2 kg quantities of enriched uranium and plutonium. Measurements have been taken of bare material as well as of material hidden within a large plywood cube. Results from this work have demonstrated the efficacy of the die-away neutron measurement technique for quickly detecting the presence of special nuclear material hidden within plywood shields by analyzing the time dependent neutron signals in-between neutron generator pulses. Using a DT electronic neutron generator operating at 300 Hz with a yield of approximately 0.36 x 10**8 neutrons per second, 2.2 kg of enriched uranium hidden within a 0.60 m x 0.60 m x 0.70 m volume of plywood was positively detected with a measurement signal 2-sigma above the passive background within 1 second. Similarly, for a 500 second measurement period a lower detection limit of approaching the gram level could be expected with the same simple set-up.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyber-Physical Trade-Offs in Distributed Detection Networks

We consider a network of sensors that measure the scalar intensity due to the background or a source combined with background, inside a two-dimensional monitoring area. The sensor measurements may be random due to the underlying nature of the source and background or due to sensor errors or both. The detection problem is infer the presence of a source of unknown intensity and location based on sensor measurements. In the conventional approach, detection decisions are made at the individual sensors, which are then combined at the fusion center, for example using the majority rule. With increased communication and computation costs, we show that a more complex fusion algorithm based on measurements achieves better detection performance under smooth and non-smooth source intensity functions, Lipschitz conditions on probability ratios and a minimum packing number for the state-space. We show that these conditions for trade-offs between the cyber costs and physical detection performance are applicable for two detection problems: (i) point radiation sources amidst background radiation, and (ii) sources and background with Gaussian distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of machine learning models with domain experts for automated sensor selection for energy fault detection

Data-driven techniques that extract insights from sensor data reduce the cost of improving system energy performance through fault detection and system health monitoring. To lower cost barriers to widespread deployment, a methodology is proposed that takes advantage of existing sensor data, encodes expert knowledge about the application system to create ‘virtual sensors’ and applies statistical and mathematical methods to reduce the time required for manual configurations. The approach combines sensor data points with encoded expert knowledge that is generic to the application system but independent of a particular deployment, thereby reducing the need to tailor to individual deployments. Additionally, this paper not only presents a method that detects faults from measured energy data, but also (1) describes an engagement method with experts in the energy system domain to identify data, (2) integrates domain knowledge with the data, (3) automatically selects from among the large pool of potential input data, and (4) uses machine learning to automatically build a data-driven fault detection model. Demonstration on a commercial building chiller plant shows that only a small number of virtual sensors is necessary for fault detection with high accuracy rates. This corresponds to the use of only five out of 52 original sensor data points features. With as few as four features, classification F1 scores exceed 90% on the training set and 80% on the testing set. The results are implementable and realizable using off-the-shelf tools. The goal is to design with domain experts an energy monitoring system that can be configured once and then widely deployed with little additional cost or effort.

47 OTHER INSTRUMENTATION↗

Neutron Detection Alternatives to 3He for National Security Applications

One of the main uses for 3He is in gas proportional counters for neutron detection. Large radiation detection systems deployed for homeland security and proliferation detection applications use such systems. Due to the large increase in use of 3He for homeland security and basic research, the supply has dwindled, and can no longer meet the demand. This has led to the search for an alternative technology to replace the use of 3He-based neutron detectors. In this paper, we review the testing of currently commercially available alternative technologies for neutron detection in large systems used in various national security applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10–90 g U/L of natural uranyl nitrate are presented. A range of gamma-ray lines is examined, including attenuation for transmission measurement of density and concentration. It was determined that transmission-corrected gamma-ray spectra provide a reliable way to monitor the 235 U concentration of uranyl nitrate solution in transfer pipes in NUCPs. Furthermore, existing predictive and analysis methods are adequate to design and realize practical designs. The 137 Cs transmission source employed in this work is viable but not optimal for 235 U densitometry determination. Validated simulations assessed the viability of 133 Ba and 57Co as alternative densitometry sources. All three gamma-ray detectors are viable for monitoring natural uranium feed; although high-purity germanium is easiest to interpret, it is, however, the least attractive as an installation instrument. Overall, for monitoring throughput in a facility such as UNCLE, emulating the uranium concentration and pump speeds of the Springfields conversion facility in the United Kingdom, an uncertainty of less than 0.17% is required in order to detect the diversion of 1 SQ of uranyl nitrate through changes in uranium concentration over an accountancy period of one year with a detection probability of 50%. As a result, calibrated gamma-ray detection systems are capable of determining the concentration of uranium content in NUCPs, it is only in combination with verifiable operator declarations and supporting data, such as flow rate and enrichment, that safeguards conclusions can be drawn.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A reversible time-of-flight detector for use in pseudocontinuous resonance enhanced multiphoton (pc-REMPI) detection

A time-of-flight coincidence detector is demonstrated. This detector is optimized for use in a pseudocontinuous resonance enhanced multiphoton ionization scheme that requires photoelectrons and photoions to be detected in coincidence. The detector utilizes two simultaneously operating charged particle detectors, one for the detection of electrons and the other for the detection of ions. In order to allow for field reversal, the detectors are physically identical, differing only by the value of applied voltages. Particular attention is given to the implementation of a charge-to-voltage transducer that allows for subnanosecond detection of both electrons and ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

Detection of radionuclides emitting short-range radiation, such as {alpha} and low-energy {beta} particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed {sup 241}Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗