Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Electrification of residential and commercial buildings integrated with hybrid renewable energy systems: A techno-economic analysis

Here, this study assesses the techno-economic viability of city-scale building electrification, comparing a base case scenario with conventional HVAC systems to an electrified scenario with heat pump systems. EnergyPlus simulations reveal a 28% increase in annual electricity consumption in the electrified scenario, shifting the peak consumption from summer to winter with a 49% surge. Hybrid renewable energy systems (HRESs) are then evaluated using HOMER Pro, considering renewable penetration from 0% to 100%. The net present cost (NPC) of the base case and electrified scenarios range from $\$10.34$ to $\$24.38$ billion and $\$8.79$ to $\$50.31$ billion, respectively. Sensitivity analysis explores the impact of carbon tax, fuel price, and renewable subsidies on HRESs in the electrified scenario. Results indicate that applying a carbon tax up to $\$120$/tonne of CO 2 increases the optimum renewable fraction from 5% to 26%, while higher fuel prices and renewable subsidies further enhance the feasibility by shifting the optimum renewable fraction to 60% and 54%, respectively, demonstrating the interplay between economic factors and renewable integration in electrified urban contexts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

Next-generation anion exchange membrane water electrolyzers operating for commercially relevant lifetimes

Alkaline anion exchange membrane (AEM) water electrolysis has gained increasing attention due to its potential to achieve low-cost, high performance hydrogen production. However, most existing membranes are not durable in industrial settings. In this work, we demonstrate good performance relative to industrial parameters using Sustainion® anion exchange membranes. Long-duration tests showed stable performance of 1 A/cm 2 at 1.85 V with a degradation rate of less than 1 μV/h over 10,000 h. The projected lifetime is thus over 20 years. Daily on/off cycling performance over the course of 30 years was simulated experimentally through accelerated voltage shock tests, resulting in a performance loss of only 0.15 μV/cycle over 11,000 cycles. As shown through impact and crossover testing, an improvement in performance is achieved by the addition of zirconia to the polymer matrix and mechanically reinforcing the membrane.

08 HYDROGEN↗

ECCI analysis of shear accommodations at grain boundaries in commercially pure alpha titanium

This study uses a novel approach that couples electron channeling contrast imaging (ECCI) with controlled removal of surface material to investigate the slip system/grain boundary interactions by assessing the geometry of slip planes and grain boundaries as a function of depth. The comparison of spacing, relative distributions, and correlations of slip bands across grain boundaries reveals surface biasing on the slip band behavior in the grain boundary region. Furthermore, using analysis of the compatibility factor m’, the Schmid factor of each slip system, and the angles θ between slip planes, a more comprehensive understanding of the details of the mechanisms of strain transfer and heterogeneous deformation is developed. In general, the misalignment of primary slip systems on the grain boundary planes necessitates the activation of secondary accommodating slip systems close to the grain boundary area that are better aligned (higher m’ and lower θ) with respect to the incoming slip system across the grain boundary. Such systems have the same Burgers vector as the primary slip systems within the respective grains, but are typically on low mobility slip planes.

59 BASIC BIOLOGICAL SCIENCES↗

Overcharge-to-thermal-runaway behavior and safety assessment of commercial lithium-ion cells with different cathode materials: A comparison study

In this paper, overcharge behaviors and thermal runaway (TR) features of large format lithium-ion (Li-ion) cells with different cathode materials (LiFePO 4 (LFP), Li[Ni 1/3 Co 1/3 Mn 1/3 ]O 2 (NCM111), Li[Ni 0.6 Co 0.2 Mn 0.2 ]O 2 (NCM622) and Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 (NCM811)) were investigated. The results showed that, under the same overcharge condition, the TR of LFP Li-ion cell occurred earlier compared with the NCM Li-ion cells, indicating its poor overcharge tolerance and high TR risk. However, when TR occurred, LFP Li-ion cell exhibited lower maximum temperature and mild TR response. All NCM Li-ion cells caught fire or exploded during TR, while the LFP Li-ion cell only released a large amount of smoke without fire. According to the overcharge behaviors and TR features, a safety assessment score system was proposed to evaluate the safety of the cells. In short, NCM Li-ion cells have better performance in energy density and overcharge tolerance (or low TR risk), while LFP Li-ion cell showed less severe response to overcharging (or less TR hazards). For NCM Li-ion cells, as the ratio of nickel in cathode material increases, the thermal stability of the cathode materials becomes poorer, and the TR hazards increase. Such a comparison study on large format Li-ion cells with different cathode materials can provide deeper insights into the overcharge behaviors and TR features, and provide guidance for engineers to reasonably choose battery materials in automotive applications.

25 ENERGY STORAGE↗