Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Use of external magnetic fields in hohlraum plasmas to improve laser-coupling

Efficient coupling of laser energy into hohlraum targets is important for indirect drive ignition. Laser-plasma instabilities can reduce coupling, reduce symmetry, and cause preheat. We consider the effects of an external magnetic field on laser-energy coupling in hohlraum targets. Experiments were performed at the Omega Laser Facility using low-Z gas-filled hohlraum targets which were placed in a magnetic coil with B{sub z} ≤ 7.5-T. We found that an external field B{sub z} = 7.5-T aligned along the hohlraum axis results in up to a 50% increase in plasma temperature as measured by Thomson scattering. The experiments were modeled using the 2-D magnetohydrodynamics package in HYDRA and were found to be in good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structure-based group A streptococcal vaccine design: Helical wheel homology predicts antibody cross-reactivity among streptococcal M protein–derived peptides

Group A streptococcus (Strep A) surface M protein, an α-helical coiled-coil dimer, is a vaccine target and a major determinant of streptococcal virulence. The sequence-variable N-terminal region of the M protein defines the M type and also contains epitopes that promote opsonophagocytic killing of streptococci. Recent reports have reported considerable cross-reactivity among different M types, suggesting the prospect of identifying cross-protective epitopes that would constitute a broadly protective multivalent vaccine against Strep A isolates. In this work, we have used a combination of immunological assays, structural biology, and cheminformatics to construct a recombinant M protein–based vaccine that included six Strep A M peptides that were predicted to elicit antisera that would cross-react with an additional 15 nonvaccine M types of Strep A. Rabbit antisera against this recombinant vaccine cross-reacted with 10 of the 15 nonvaccine M peptides. Two of the five nonvaccine M peptides that did not cross-react shared high sequence identity (≥50%) with the vaccine peptides, implying that high sequence identity alone was insufficient for cross-reactivity among the M peptides. Additional structural analyses revealed that the sequence identity at corresponding polar helical-wheel heptad sites between vaccine and nonvaccine peptides accurately distinguishes cross-reactive from non–cross-reactive peptides. On the basis of these observations, we developed a scoring algorithm based on the sequence identity at polar heptad sites. When applied to all epidemiologically important M types, this algorithm should enable the selection of a minimal number of M peptide–based vaccine candidates that elicit broadly protective immunity against Strep A.

60 APPLIED LIFE SCIENCES↗

Optimization of COMPASS-U Support Structure

The global support structure for Compass Upgrade (COMPASS-U) employs many bolted and pinned components to improve the manufacturability of the whole structures. This is a departure from other designs used for highly loaded tokamaks, like Alcator C-Mod which used large forgings. Modeling of the numerous connections and interfaces was a challenge. This article will describe how to optimize the C-frame support structure with the goal to eliminate differential displacements at those interfaces and, importantly, minimize toroidal mutual displacement at the sliding joint of the toroidal field (TF) coils. The global support structure consists of 16 C-frames, and it can be simplified as a 1/8th cyclic symmetry model due to the eight vertical rods mounting that connect bottom CS and PF1-3 assemblies to the C-frames. Structure variants with different connection webs between two neighboring C-frames have been analyzed. The preloading of bolts can be split into several preload substeps to simulate the real assembly process of the COMPASS-U support structure. Additionally, the TF crown and the wedge plate can be further improved to become a solid part to better hold the TF coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Design of a RapidDischarge Varistor System for the MICE Magnet Circuits

The need for a magnet circuit discharge system, in order to protect the magnet HTS leads during a power failure, has been discussed in recent MICE reports [1], [2]. In order to rapidly discharge a magnet, one has to put enough resistance across the lead. The resistance in this case is varistor that is put across the magnet in the event of a power outage. The resistance consists of several diodes, which act as constant voltage resistors and the resistance of the cables connecting the magnets in the circuit to each other and to the power supply. In order for the rapid discharge system to work without quenching the magnets, the voltage across the magnets must be low enough so that the diodes in the quench protection circuit don't fire and cause the magnet current to bypass the superconducting coils. It is proposed that six rapid discharge varistors be installed across the three magnet circuits the power the tracker solenoids, which are connected in series. The focusing magnets, which are also connected in series would have three varistors (one for each magnet). The coupling magnets would have a varistor for each magnet. The peak voltage that is allowed per varistor depends on the number of quench protection diodes that make up the quench protection circuit for each magnet coil circuit. It is proposed that the varistors be water cooled as the magnet circuits are being discharged through them. The water cooling circuit can be supplied with tap water. The tap water flows only when the varistor temperature reaches a temperature of 45 C.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Main-sequence Scatter is Real: The Joint Dependence of Galaxy Clustering on Star Formation and Stellar Mass

We present new measurements of the clustering of stellar-mass-complete samples of ∼40,000 SDSS galaxies at z ∼ 0.03 as a joint function of stellar mass and specific star formation rate (sSFR). Our results confirm what Coil et al. find at z ∼ 0.7: galaxy clustering is a stronger function of sSFR at fixed stellar mass than of stellar mass at fixed sSFR. We also find that galaxies above the star-forming main sequence (SFMS) with higher sSFR are less clustered than galaxies below the SFMS with lower sSFR, at a given stellar mass. A similar trend is present for quiescent galaxies. This confirms that main-sequence scatter, and scatter within the quiescent sequence, is physically connected to the large-scale cosmic density field. We compare the resulting galaxy bias versus sSFR, and relative bias versus sSFR ratio, for different galaxy samples across 0 < z < 1.2 to mock galaxy catalogs based on the empirical galaxy evolution model of Behroozi et al. This model fits PRIMUS and DEEP2 clustering data well at intermediate redshift, but agreement with SDSS is not as strong. We show that increasing the correlation between galaxy SFR and halo accretion rate at z ∼ 0 in the model substantially improves agreement with SDSS data. Mock catalogs suggest that central galaxies contribute substantially to the dependence of clustering on sSFR at a given stellar mass and that the signal is not simply an effect of satellite galaxy fraction differences with sSFR. Our results are highly constraining for galaxy evolution models and show that the stellar-to-halo mass relation depends on sSFR.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and validation of quasi-steady-state heat pump water heater model having stratified water tank and wrapped-tank condenser

Heat pump water heater systems (HPWH) introduce new challenges for design and modeling tools, because they require vapor compression system balanced with a water storage tank. In addition, a wrapped-tank condenser coil has strong coupling with a stratified water tank, which leads HPWH simulation to a transient process. To tackle these challenges and deliver an effective, hardware-based HPWH equipment design tool, a quasi-steady-state HPWH model was developed based on the DOE/ORNL Heat Pump Design Model (HPDM). Two new component models were added via this study. One is a one-dimensional stratified water tank model, an improvement to the open-source EnergyPlus water tank model, by introducing a calibration factor to account for bulk mixing effect due to water draws, circulations, etc. The other is a wrapped-tank condenser coil model, using a segment-to-segment modeling approach. In conclusion, the HPWH system model was validated against available experimental data. After that, the model was used for parametric simulations to determine the effects of various design factors.

42 ENGINEERING↗

The Generation of Intense Radiofrequency Fields in uCoils

Large amplitude radiofrequency (rf) fields hold great promise in wide line NMR where it becomes possible to excite the full breadth of the line in a quantitative fashion. Applications in quadrupole NMR and in NMR of paramagnetic systems benefit greatly from intense fields. Spin manipulations in multiple quantum NMR experiments, specifically, the generation of multiple quantum coherence in MQ NMR, are more efficiently produced using intense rf fields. In this work we describe a coil probe that produces an rf field of 25 MHz, more than five times larger than the greatest rf field reported in the literature. We accomplish this in a robust, 127 {micro}m diameter solenoid coil using 1 kW of rf power.

47 OTHER INSTRUMENTATION↗

Observations and analysis of magnetic fluctuations in the Maryland centrifugal experiment

Initial results from magnetic probes on the Maryland Centrifugal eXperiment (MCX) [R. F. Ellis et al., Phys. Plasmas 8, 2057 (2001)] provide details of the propagation and azimuthal mode structure of magnetic fluctuations in the edge region. Magnetic coils placed azimuthally along the edge measure changes in the axial magnetic field during the time history of the plasma discharge. The eight evenly spaced coils can resolve azimuthal modes up to m=3. The plasma rotates azimuthally in MCX due to an applied radial electric field. Using a variety of different analysis of the data, it is inferred that the magnetic fluctuations are dominantly convected by the plasma rotation for several rotation periods before significant decorrelation. These findings help to identify the modes at the edge and indicate that there are a few low mode numbers that are dominant during the discharge. Also, the speed of rotation of the modes is found to change dramatically from the High Rotation (HR) state to a low rotation ordinary (O) state, consistent with a corresponding change in the plasma load voltage. The fluctuation spectrum becomes dominated by a single mode after the transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time estimation of the poloidal wavenumber of ISTTOK tokamak magnetic fluctuations

The successful control of a fusion plasma discharge relies on the continuous improvement of existing diagnostics and on the development of new ones based on innovative concepts. It is equally important to provide efficient numerical tools capable of extracting, in real time, the most important physical quantities emerging from the collected data. This encompasses, for instance, the determination of the wavenumber and amplitude tracking of plasma instabilities, a necessary ingredient for establishing in real time the type of feedback control stabilization scheme to be used. In this paper, the characterization of the wavenumber spectra of unstable modes observed in ISTTOK plasma discharges is addressed using a set of two poloidal arrays of magnetic coils (Mirnov coils). In particular, the prospect for the estimation of the poloidal wavenumber in real time using recursive filtering techniques is investigated. It is shown that, in contrast with typical cross-spectrum analysis, where a large dataset is required to estimate the wavenumbers, with this innovative technique, the wavenumber spectra may be obtained in faster time scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic design calculation and FRC formation modeling for the field reversed experiment liner

Integrated magnetic modeling and design are important to meet the requirements for (1) formation, (2) translation, and (3) compression of a field reversed configuration (FRC) for magnetized target fusion. Off-the-shelf solutions do not exist for many generic design issues. A predictive capability for time-dependent magnetic diffusion in realistically complicated geometry is essential in designing the experiment. An eddy-current code was developed and used to compute the mutual inductances between driven magnetic coils and passive magnetic shields (flux excluder plates) to calculate the self-consistent axisymmetric magnetic fields during the first two stages. The plasma in the formation stage was modeled as an immobile solid cylinder with selectable constant resistivity and magnetic flux that was free to readjust itself. It was concluded that (1) use of experimentally obtained anomalously large plasma resistivity in magnetic diffusion simulations is sufficient to predict magnetic reconnection and FRC formation, (2) comparison of predicted and experimentally observed timescales for FRC Ohmic decay shows good agreement, and (3) for the typical range of resistivities, the magnetic null radius decay rate scales linearly with resistivity. The last result can be used to predict the rate of change in magnetic flux outside of the separatrix (equal to the back-emf loop voltage), and thus estimate a minimum {theta}-coil loop voltage required to form an FRC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Superconducting transformer system for high current cable testing

This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

43 PARTICLE ACCELERATORS↗

Control of ion density distribution by magnetic traps for plasma electrons

The effect of a magnetic field of two magnetic coils on the ion current density distribution in the setup for low-temperature plasma deposition is investigated. The substrate of 400 mm diameter is placed at a distance of 325 mm from the plasma duct exit, with the two magnetic coils mounted symmetrically under the substrate at a distance of 140 mm relative to the substrate centre. A planar probe is used to measure the ion current density distribution along the plasma flux cross-sections at distances of 150, 230, and 325 mm from the plasma duct exit. It is shown that the magnetic field strongly affects the ion current density distribution. Transparent plastic films are used to investigate qualitatively the ion density distribution profiles and the effect of the magnetic field. A theoretical model is developed to describe the interaction of the ion fluxes with the negative space charge regions associated with the magnetic trapping of the plasma electrons. Theoretical results are compared with the experimental measurements, and a reasonable agreement is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle deconfinement in a bent magnetic mirror

Coils misalignment in a magnetic mirror can produce additional particle transport. The magnetic field non axi-symmetry is responsible for radial and longitudinal drifts in a way much similar to the neo-classical transport in a tandem mirror cell distorted by end plugs. Accordingly, a regime exhibiting large radial displacements--similar to the resonant regime in tandem mirrors--can be obtained by confining ions azimuthally, for example by means of a properly tuned radial electric field. Because of the mass dependence of the magnetic field non-homogeneity drift velocities, the azimuthal trapping is mass specific, allowing, in principle, the filtering of a specific species based on its mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Irradiation imposed degradation of the mechanical and electrical properties of electrical insulation for future accelerator magnets

Future accelerators will make extensive use of superconductors made of Nb{sub 3}Sn, which allows higher magnetic fields than NbTi. However, the wind-and-react technology of Nb{sub 3}Sn superconducting magnet production makes polyimide Kapton® non applicable for the coils' electrical insulation. A Nb{sub 3}Sn technology compatible insulation material should be characterized by high radiation resistivity, good thermal conductivity, and excellent mechanical properties. Candidate materials for the electrical insulation of future accelerator's magnet coils have to be radiation certified with respect to potential degradation of their electrical, thermal, and mechanical properties. This contribution presents procedures and results of tests of the electrical and mechanical properties of DGEBA epoxy + D400 hardener, which is one of the candidates for the electrical insulation of future magnets. Two test sample types have been used to determine the material degradation due to irradiation: a untreated one (unirradiated) and irradiated at 77 K with 11 kGy/min intense, 4MeV energy electrons beam to a total dose of 50 MGy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrically insulated MLI and thermal anchor

The thermal shield of JT-60SA is kept at 80 K and will use the multilayer insulation (MLI) to reduce radiation heat load to the superconducting coils at 4.4 K from the cryostat at 300 K. Due to plasma pulse operation, the MLI is affected by eddy current in toroidal direction. The MLI is designed to suppress the current by electrically insulating every 20 degree in the toroidal direction by covering the MLI with polyimide films. In this paper, two kinds of designs for the MLI system are proposed, focusing on a way to overlap the layers. A boil-off calorimeter method and temperature measurement has been performed to determine the thermal performance of the MLI system. The design of the electrical insulated thermal anchor between the toroidal field (TF) coil and the thermal shield is also explained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconductive quantum interference magnetometer with high sensitivity achieved by an induced resonance

A fully integrated low noise superconducting quantum interference device (SQUID) in a magnetometer configuration is presented. An intrinsic high voltage responsivity as high as 500 μV/Φ{sub 0} has been obtained by introducing a resonance in the voltage – magnetic flux characteristic. This resonance is induced by an integrated superconducting coil surrounding the pick-up coil and connected to one end of the SQUID output. The SQUID magnetometer exhibits a spectral density of magnetic field noise as low as 3 fT/Hz{sup 1/2}. In order to verify the suitability of the magnetometer, measurements of bandwidth and slew rate have been performed and compared with those of the same device without the resonance and with additional positive feedback. Due to their good characteristics such devices can be employed in a large number of applications including biomagnetism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micromagnetic model analysis of integrated single-pole-type head with tilted spin-torque oscillator for high-frequency microwave-assisted magnetic recording

The spin-torque oscillator (STO) is the most important component in microwave-assisted magnetic recording. Some requirements for the STO are: large amplitude and stable oscillation, small injected current, and oscillation at a frequency that excites resonance in a recording medium. It is also necessary for the STO oscillation to closely follow the head coil current. In this paper, STOs were integrated into write heads and micromagnetic analyses carried out to obtain a write head structure with stable STO oscillation that could follow a high-frequency head coil current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗