Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Transient Optimization of a Gas Turbine Engine

Gas turbine engines are the primary power plants for modern commercial aircraft. Transients prompted by significant changes in thrust or power demand are common and unavoidable. Extreme transient scenarios such as those associated with a go-around during a landing attempt are possible and must be accounted for in the design of the engine and its controller. Engine transients tend to cause a reduction in compressor operability margin, which must be addressed by the engine control system and accounted for in the engine design to prevent events such as compressor stall/surge and combustor blow out. Transient operability concerns typically lead to compromises in the engine design that sacrifice efficiency and/or limit responsiveness. Transient operability is typically managed by logic that limits the fuel flow command. If this logic is not optimized, then the potential for valuable performance could be lost. This study presents a strategy for optimizing the transient limit logic and proposes a strategy for updating the control logic over the lifespan of the engine. The results demonstrate significant improvements in transient operability. For example, of the results at sea level static conditions demonstrated a 31% reduction in the usage of the high pressure compressor operability stack during a snap acceleration transient. Furthermore, a reinforcement learning algorithm is demonstrated to modify the transient logic as the engine degrades to minimize response time while respecting a prescribed compressor operability margin limit. A simple demonstration of the reinforcement learning algorithm resulted in a thrust response time reduction of ~11.8%.

transient↗

Transient Optimization of a Gas Turbine Engine

Gas turbine engines are the primary power plants for modern commercial aircraft. Transients prompted by significant changes in thrust or power demand are common and unavoidable. Extreme transient scenarios such as those associated with a go-around during a landing attempt are possible and must be accounted for in the design of the engine and its controller. Engine transients tend to cause a reduction in compressor operability margin, which must be addressed by the engine control system and accounted for in the engine design to prevent events such as compressor stall/surge and combustor blow out. Transient operability concerns typically lead to compromises in the engine design that sacrifice efficiency and/or limit responsiveness. Transient operability is typically managed by logic that limits the fuel flow command. If this logic is not optimized, then the potential for valuable performance could be lost. This study presents a strategy for optimizing the transient limit logic and proposes a strategy for updating the control logic over the lifespan of the engine. The results demonstrate significant improvements in transient operability. For example, of the results at sea level static conditions demonstrated a 31% reduction in the usage of the high pressure compressor operability stack during a snap acceleration transient. Furthermore, a reinforcement learning algorithm is demonstrated to modify the transient logic as the engine degrades to minimize response time while respecting a prescribed compressor operability margin limit. A simple demonstration of the reinforcement learning algorithm resulted in a thrust response time reduction of ~11.8%.

transient↗

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics↗

Design of the ILC RTML Extraction Lines

The ILC [1] Damping Ring to the Main Linac beamline (RTML) contains three extraction lines (EL). Each EL can be used both for an emergency abort dumping of the beam and tune-up continual train-by-train extraction. Two of the extraction lines are located downstream of the first and second stages of the RTML bunch compressor, and must accept both compressed and uncompressed beam with energy spreads of 2.5% and 0.15%, respectively. In this paper we report on an optics design that allowed minimizing the length of the extraction lines while offsetting the beam dumps from the main line by the distance required for acceptable radiation levels in the service tunnel. The proposed extraction lines can accommodate beams with different energy spreads while at the same time providing the beam size acceptable for the aluminum dump window. The RTML incorporates three extraction lines, which can be used for either an emergency beam abort or for a train-by-train extraction. The first EL is located downstream of the Damping Ring extraction arc. The other two extraction lines are located downstream of each stage of the two-stage bunch compressor. The first extraction line (EL1) receives 5GeV beam with an 0.15% energy spread. The extraction line located downstream of the first stage of bunch compressor (ELBC1) receives both compressed and uncompressed beam, and therefore must accept beam with both 5 and 4.88GeV energy, and 0.15% and 2.5% energy spread, respectively. The extraction line located after the second stage of the bunch compressor (ELBC2) receives 15GeV beam with either 0.15 or 1.8% energy spread. Each of the three extraction lines is equipped with the 220kW aluminum ball dump, which corresponds to the power of the continuously dumped beam with 5GeV energy, i.e., the beam trains must be delivered to the ELBC2 dump at reduced repetition rate.

43 PARTICLE ACCELERATORS↗

Helium Brayton Cycle Design for Advanced High Temperature Reactor System

Gen-IV reactors have many advantages over current generation reactors. Higher outlet temperatures in these next generation reactors allow for other power cycles to be considered, such as the helium Brayton cycle. Additionally, the higher temperatures allow the energy to be utilized in other industrial applications. The advanced high temperature reactor concept utilizes the helium Brayton cycle for electricity production. The system consists of four components shown in Fig. 1. This includes a turbine, recuperator, precooler, and compressor. The helium coolant exits the secondary heat exchanger (SHX) at a high temperature and enters the turbine. Helium spins the turbine causing the generator to spin producing electricity. The pressure and temperature drop as the coolant travels through the turbine. The helium enters a recuperator where the cold side stream exiting the compressor is heated up. Helium then travels through a precooler where water is used to cool down the helium before entering the compressor. Helium enters the compressor where the temperature and pressure of the coolant increase. Compressed helium travels through the recuperator heating up to the desired temperature before entering the SHX again. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Off-design performance of an organic Rankine-vapor compression cooling cycle using R1234ze(E)

In this study, a 264 kW th organic Rankine-vapor compression cycle (ORVC) was experimentally tested over a range of conditions to quantify the individual impact of off-design external conditions. The ORVC was designed to recover waste heat at 91 °C, reject heat to a liquid condenser stream at 30 °C, and produce chilled water at 7 °C. Here, the condenser heat rejection temperature was varied from 16.6 °C to 32.6 °C, the chilled water delivery temperature was varied between 2.1 °C and 13.1 °C, and the heat input temperature was varied from 91 °C to 120 °C. As the condenser heat rejection temperature decreased, the coefficient of performance (COP) of the ORVC improved from 0.558 at 30 °C to 0.682 at 16.6 °C, despite a reduction in compressor isentropic efficiency. Although the chilled water temperature variation had almost no impact on the organic Rankine cycle performance, the compressor efficiency decreased when the delivery temperature was below 7 °C. At the highest chilled water temperature, 13.1 °C, the COP of the ORVC was 0.643. Compressor stall was noted when the condenser heat rejection temperature was greater than 32.6 °C and the chilled water delivery temperature was below 2.1 °C. Increasing the driving heat source inlet temperature improved the COP of the ORVC and the thermal efficiency of the organic Rankine power cycle, while decreasing the efficiency of the compressor and the COP of vapor compression cycle. In addition, the integrated part load value of the system was determined through experimentation to be 0.682, which provides a realistic estimate of real-world performance.

30 DIRECT ENERGY CONVERSION↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient and thermo-economic analysis of MED-MVC desalination system

An exergo-economic model is used to assess the performance of a multi-effect desalination plant integrated to a mechanical vapor compressor unit (MED-MVC) with a water production capacity of 1500 $m^3$/day. The results show that the second law efficiency ($\eta_{II}$) 2.8%. The MVC and evaporator units are responsible for about 39 and 52% of the total exergy destruction, respectively. The total water price (TWP) is 1.70 $\$/m^3$ when calculated using a simple conventional economic model and 1.63 $\$/m^3$ when calculated using an exergy-based cost model. Increasing the number of effects from 1 to 6 results in a 39% reduction in the specific power consumption (SPC), a 70% increase in $\eta_{II}$ and a 24% decrease in TWP. A dynamic model is developed to investigate the effect of fluctuations of compressor work ($\dot{W}_c$) and inlet seawater temperature ($T_{sw}$) on the plant behavior and performance. The dynamic model results show that the disturbance in $\dot{W}$ has a significant effect on the plant transient behavior and may cause the plant to cease operation while a disturbance in $T_{sw}$ has only a moderate impact. Increasing $T_{sw}$ above a certain value of the steady-state condition without proper control on the plant response could lead to evaporator dry out. In term of performance, a reduction in $\dot{W}_c$ causes a decrease in the plant production capacity and SPC, while it increases the plant performance ratio (PR). On the other hand, a reduction in the inlet $T_{sw}$ causes a reduction in the plant production capacity and PR and an increase in SPC for the same compressor work. Furthermore, a comparison between a MED-MVC system and a MED integrated to a thermal vapor compressor system (MED-TVC) reveals that the latter system is rather sensitive to the reduction in $T_{sw}$ due to the presence of the condenser unit in the MED-TVC. The response of the MED-MVC system is slower than the MED-TVC which is due to the high thermal capacity of the preheaters for the feed in the MED-MVC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants

Based on laboratory investigations for R-22 and R-410A alternative low GWP refrigerants in two baseline rooftop air conditioners (RTU), the DOE/ORNL Heat Pump Design Model was used to model the two RTUs and the models were calibrated against the experimental data. We compared the compressor efficiencies and heat exchanger performances. An efficiency-based compressor mapping method was developed. Extensive model-based optimizations were conducted to provide a fair comparison between all the low GWP candidates by selecting optimal configurations. The results illustrate that all the R-22 low GWP refrigerants will lead to slightly lower COPs. ARM-20B appears to be the best R-22 replacement at normal conditions. At higher ambient temperatures, ARM-20A exhibits better performance. All R-410A low GWP candidates will result in similar or better efficiencies than R-410A. R-32 has the best COP while requiring the smallest compressor. Finally, R-452B uses the closest compressor displacement volume and achieves the same efficiency as R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commissioning of helium compression system for the 12 GeV refrigerator

The compressor system used for the Jefferson Lab (JLab) 12 GeV upgrade, also known as the CHL-2 compressor system, incorporates many design changes to the typical compressor skid design to improve the efficiency, reliability and maintainability from previous systems. These include a considerably smaller bulk oil separator design that does not use coalescing elements/media, automated control of cooling oil injection based on the helium discharge temperature, a helium after-cooler design that is designed for and promotes coalescing of residual oil and a variable speed bearing oil pump to reduce oil bypass. The CHL-2 helium compression system has five compressors configured with four pressure levels that supports the three pressure levels in the cold box. This paper will briefly review several of these improvements and discuss some of the recent commissioning results.

42 ENGINEERING↗

Commissioning of a replacement subatmospheric cold box for Jefferson Lab’s Central Helium Liquefier

Jefferson Lab’s Cryogenics Department has designed, fabricated, installed, and commissioned a new subatmospheric cold box to replace one of the two existing units within our Central Helium Liquefier (CHL). The replacement cold box, dubbed SC1R, pumps saturated helium vapor at 0.0385 atm from Jefferson Lab’s continuous electron beam accelerator facility (CEBAF) cryomodules to maintain an operating temperature of nominally 2.1 K. This is accomplished using a five-stage cryogenic centrifugal compressor (cold compressor) system and a brazed aluminum plate-fin heat exchanger operating between 2.1 K and 4.5 K. In this paper we will describe our experience commissioning the SC1R cold box. We will discuss pump-down of the system to 2.1 K and steady-state operation at the cold compressor design flow rates of 170, 200, and 250 g/s. Performance of the heat exchanger and cold compressors has been mapped across a range of flow rates and optimized for CEBAF operations. This commissioning data will be used to monitor future performance and adapt to changing load requirements.

Mastracci, B.↗

Optimizing Error-Bounded Lossy Compression for Scientific Data by Dynamic Spline Interpolation

Today's scientific simulations are producing vast volumes of data that cannot be stored and transferred efficiently because of limited storage capacity, parallel I/O bandwidth, and network bandwidth. The situation is getting worse over time because of the ever-increasing gap between relatively slow data transfer speed and fast-growing computation power in modern supercomputers. Error-bounded lossy compression is becoming one of the most critical techniques for resolving the big scientific data issue, in that it can significantly reduce the scientific data volume while guaranteeing that the reconstructed data is valid for users because of its compression-error-bounding feature. In this paper, we present a novel error-bounded lossy compressor based on a state-of-the-art prediction-based compression framework. Our solution exhibits substantially better compression quality than all of the existing error-bounded lossy compressors, with comparable compression speed. Specifically, our contribution is threefold. (1) We provide an in-depth analysis of why the best-existing prediction-based lossy compressor can only minimally improve the compression quality. (2) We propose a dynamic spline interpolation approach with a series of optimization strategies that can significantly improve the data prediction accuracy, substantially improving the compression quality in turn. (3) We perform a thorough evaluation using six real-world scientific simulation datasets across different science domains to evaluate our solution vs. all other related works. Experiments show that the compression ratio of our solution is higher than that of the second-best lossy compressor by 20%similar to 460% with the same error bound in most of the cases.

Zhao, Kai↗

Optimization of Error-Bounded Lossy Compression for Hard-to-Compress HPC Data

Since today’s scientific applications are producing vast amounts of data, compressing them before storage/transmission is critical. Results of existing compressors show two types of HPC data sets: highly compressible and hard to compress. In this work, we carefully design and optimize the error-bounded lossy compression for hard-tocompress scientific data. We propose an optimized algorithm that can adaptively partition the HPC data into best-fit consecutive segments each having mutually close data values, such that the compression condition can be optimized. Another significant contribution is the optimization of shifting offset such that the XOR-leading-zero length between two consecutive unpredictable data points can be maximized. We finally devise an adaptive method to select the best-fit compressor at runtime for maximizing the compression factor. We evaluate our solution using 13 benchmarks based on real-world scientific problems, and we compare it with 9 other state-of-the-art compressors. Experiments show that our compressor can always guarantee the compression errors within the user-specified error bounds. Most importantly, our optimization can improve the compression factor effectively, by up to 49% for hard-tocompress data sets with similar compression/decompression time cost.

97 MATHEMATICS AND COMPUTING↗

Efficient Lossy Compression for Scientific Data Based on Pointwise Relative Error Bound

An effective data compressor is becoming increasingly critical to today's scientific research, and many lossy compressors are developed in the context of absolute error bounds. Based on physical/chemical definitions of simulation fields or multiresolution demand, however, many scientific applications need to compress the data with a pointwise relative error bound (i.e., the smaller the data value, the smaller the compression error to tolerate). To this end, we propose two optimized lossy compression strategies under a state-of-the-art three-staged compression framework (prediction + quantization + entropy-encoding). The first strategy (called block-based strategy) splits the data set into many small blocks and computes an absolute error bound for each block, so it is particularly suitable for the data with relatively high consecutiveness in space. The second strategy (called multi-threshold-based strategy) splits the whole value range into multiple groups with exponentially increasing thresholds and performs the compression in each group separately, which is particularly suitable for the data with a relatively large value range and spiky value changes. We implement the two strategies rigorously and evaluate them comprehensively by using two scientific applications which both require lossy compression with point-wise relative error bound. Experiments show that the two strategies exhibit the best compression qualities on different types of data sets respectively. In conclusion, the compression ratio of our lossy compressor is higher than that of other state-of-the-art compressors by 17.2-618 percent on the climate simulation data and 30-210 percent on the N-body simulation data, with the same relative error bound and without degradation of the overall visualization effect of the entire data.

97 MATHEMATICS AND COMPUTING↗

A General Framework for Progressive Data Compression and Retrieval

In scientific simulations, observations, and experiments, the transfer of data to and from disk and across networks has become a major bottleneck for data analysis and visualization. Compression techniques have been employed to tackle this challenge, but traditional lossy methods often demand conservative error tolerances to meet the numerical accuracy requirements of both anticipated and unknown data analysis tasks. Progressive data compression and retrieval has emerged as a promising solution, where each analysis task dictates its own accuracy needs. However, few analysis algorithms inherently support progressive data processing, and adapting compression techniques, file formats, client/server frameworks, and APIs to support progressivity can be challenging. Here, this paper presents a framework that enables progressive-precision data queries for any data compressor or numerical representation. Our strategy hinges on a multi-component representation that successively reduces the error between the original and compressed field, allowing each field in the progressive sequence to be expressed as a partial sum of components. We have implemented this approach with four established scientific data compressors and assessed its effectiveness using real-world data sets from the SDRBench collection. The results show that our framework competes in accuracy with the standalone compressors it is based upon. Additionally, (de)compression time is proportional to the number of components requested by the user. Finally, our framework allows for fully lossless compression using lossy compressors when a sufficient number of components are employed.

97 MATHEMATICS AND COMPUTING↗

A Survey on Error-Bounded Lossy Compression for Scientific Datasets

Error-bounded lossy compression has been effective in significantly reducing the data storage/transfer burden while preserving the reconstructed data fidelity very well. Many error-bounded lossy compressors have been developed for a wide range of parallel and distributed use cases for years. They are designed with distinct compression models and principles, such that each of them features particular pros and cons. In this article, we provide a comprehensive survey of emerging error-bounded lossy compression techniques. The key contribution is fourfold. (1) We summarize a novel taxonomy of lossy compression into six classic models. (2) We provide a comprehensive survey of 10 commonly used compression components/modules. (3) We summarized pros and cons of 47 state-of-the-art lossy compressors and present how state-of-the-art compressors are designed based on different compression techniques. (4) We discuss how customized compressors are designed for specific scientific applications and use-cases. We believe this survey is useful to multiple communities including scientific applications, high-performance computing, lossy compression, and big data.

Error-Bounded Lossy Compression↗

High-Current Cold Cathode Employing Diamond and Related Materials

The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

36 MATERIALS SCIENCE↗