Status of PLS-II Upgrade Program

The Pohang Light Source (PLS) at the Pohang Accelerator Laboratory has been operated first at 2.0 GeV since 1995, and later was upgraded to 2.5 GeV. During this time, 6 insertion devices like undulators and multipole wigglers have been put into operation to produce special photon beams, with a total of 27 beamlines installed and 3 beamlines under construction. Recently, Korea synchrotron user's community is demanding high beam stability, higher photon energies as well as more straight sections for insertion devices in the PLS. To meet the user requirements, the PLS-II upgrade program has been launched in January, 2009, incorporating a modified chromatic version of Double Bend Achromat (DBA) to achieve almost twice as many straight sections as the current PLS with a design goal of the relatively low emittance, {epsilon}, of 5.9 nm{center_dot}rad. In the PLS-II, the top-up injection using full energy linac is planned for much higher stable beam as well and thus the production of hard x-ray undulator radiation of 8 to 13 keV is anticipated to allow for the successful research program namely Protein Crystallography. The PLS-II machine components of storage ring, linear accelerator and photon beamlines will be partly dismantled and reinstalled in a 6-months shutdown beginning January, 2011 and then the PLS-II upgrade be started the initial commissioning with a 100 mA beam current from July in 2011.

43 PARTICLE ACCELERATORS↗

The Status of the Taiwan Photon Source

NSRRC has been operating a 1.5 GeV synchrotron light source, the Taiwan Light Source (TLS), for over 15 years and has established a large user community. For the future development of synchrotron radiation research in Taiwan, a feasibility study report to construct a 3.0 GeV low-emittance storage ring, the Taiwan Photon Source (TPS), was issued in July 2005. The government approval of the TPS project was obtained in December 2007 and the machine will be built at current site of NSRRC. The project has progressed steadily since and reached several major milestones now: the architect firm has finished the site plan and civil design, the accelerator design has been fixed, and purchase of long-lead items begins its course. The TPS storage ring has a circumference of 518.4 meters with a concentric booster of 496.8 meters. The storage ring adopted a 24-cell double-bend structure with a 1.6 nm-rad natural emittance. There are six 12-m and eighteen 7-m ID straights. For user research, five new beamlines have been selected for the Phase I operations: the micro protein crystallography, the materials sub-micron diffraction, the inelastic soft x-ray scattering, the coherent x-ray scattering, and the nano probe beamlines. The civil construction is getting ready to start. The commissioning of the TPS storage ring is targeted for 2013.

43 PARTICLE ACCELERATORS↗

The High Energy Materials Science Beamline (HEMS) at PETRA III

The HEMS Beamline at the German high-brilliance synchrotron radiation storage ring PETRA III is fully tunable between 30 and 250 keV and optimized for sub-micrometer focusing. Approximately 70 % of the beamtime will be dedicated to Materials Research. Fundamental research will encompass metallurgy, physics and chemistry with first experiments planned for the investigation of the relationship between macroscopic and micro-structural properties of polycrystalline materials, grain-grain-interactions, and the development of smart materials or processes. For this purpose a 3D-microsctructure-mapper has been designed. Applied research for manufacturing process optimization will benefit from high flux in combination with ultra-fast detector systems allowing complex and highly dynamic in-situ studies of micro-structural transformations, e.g. during welding processes. The beamline infrastructure allows accommodation of large and heavy user provided equipment. Experiments targeting the industrial user community will be based on well established techniques with standardized evaluation, allowing full service measurements, e.g. for tomography and texture determination. The beamline consists of a five meter in-vacuum undulator, a general optics hutch, an in-house test facility and three independent experimental hutches working alternately, plus additional set-up and storage space for long-term experiments. HEMS is under commissioning as one of the first beamlines running at PETRA III.

43 PARTICLE ACCELERATORS↗

Data acquisition and control software for XRD beamline at Indus-2

X-ray diffraction (XRD) beamline is under commissioning on Indus-2 synchrotron radiation facility. The experimental setup of XRD beamline consists of a six-circle diffractometer and various detector systems such as scintillation detector, ionization chamber and image plate. The diffractometer can be controlled via EIA232 serial interface or Ethernet. Standard data acquisition software with a graphical user interface has been developed using LabVIEW. A firm safety and error handling scheme is implemented for failsafe operation of the experimental station. This paper describes in detail the data acquisition and control software for the experimental station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction of a New VUV/Soft X-ray Undulator Beamline BL-13A in the Photon Factory for Study of Organic Thin Films and Biomolecules Adsorbed on Surfaces

A planar undulator beamline, BL-13A, covering 30-1,000 eV has been constructed in the Photon Factory. The main scientific targets are investigations of organic thin films and biomolecules adsorbed on well-defined surfaces using angle-resolved photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy. A variable-included-angle Monk-Gillieson mounting monochromator with varied-line-spacing plane gratings is used to achieve a high photon flux of 10{sup 10}-10{sup 12} photons/s with a high resolution (E/{Delta}E) of 7,000-30,000. A typical spot size on the sample position is estimated to be 130 {mu}m (horizontal)x40 {mu}m (vertical). After commissioning, BL-13A will be open for users from January 2010.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8

The investigation of accurate structure at charge density level will not only understand the function mechanism of physical property but also lead to design new functional materials. We have successfully installed large cylindrical camera at the BL02B1/SPring-8. In conceptual design, the image plate (IP) was selected as the detector, because such IP will not only detect wide range in one shot but also yield reliable data. In commissioning, the performance of this camera demonstrated to be suitable for the direct observation of d-electron system.

43 PARTICLE ACCELERATORS↗

The Imaging and Medical Beam Line at the Australian Synchrotron

As a result of the enthusiastic support from the Australian biomedical, medical and clinical communities, the Australian Synchrotron is constructing a world-class facility for medical research, the 'Imaging and Medical Beamline'. The IMBL began phased commissioning in late 2008 and is scheduled to commence the first clinical research programs with patients in 2011. It will provide unrivalled x-ray facilities for imaging and radiotherapy for a wide range of research applications in diseases, treatments and understanding of physiological processes. The main clinical research drivers are currently high resolution and sensitivity cardiac and breast imaging, cell tracking applied to regenerative and stem cell medicine and cancer therapies. The beam line has a maximum source to sample distance of 136 m and will deliver a 60 cm by 4 cm x-ray beam1 - monochromatic and white - to a three storey satellite building fully equipped for pre-clinical and clinical research. Currently operating with a 1.4 Tesla multi-pole wiggler, it will upgrade to a 4.2 Tesla device which requires the ability to handle up to 21 kW of x-ray power at any point along the beam line. The applications envisaged for this facility include imaging thick objects encompassing materials, humans and animals. Imaging can be performed in the range 15-150 keV. Radiotherapy research typically requires energies between 30 and 120 keV, for both monochromatic and broad beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benefits and concerns of a closed nuclear fuel cycle

Nuclear power can play an important role in our energy future, contributing to increasing electricity demand while at the same time decreasing carbon dioxide emissions. However, the nuclear fuel cycle in the United States today is unsustainable. As stated in the 1982 Nuclear Waste Policy Act, the U.S. Department of Energy is responsible for disposing of spent nuclear fuel generated by commercial nuclear power plants operating in a “once-through” fuel cycle in the deep geologic repository located at Yucca Mountain. However, unyielding political opposition to the site has hindered the commissioning process to the extant that the current administration has recently declared the unsuitability of the Yucca Mountain site. In light of this the DOE is exploring other options, including closing the fuel cycle through recycling and reprocessing of spent nuclear fuel. The possibility of closing the fuel cycle is receiving special attention because of its ability to minimize the final high level waste (HLW) package as well as recover additional energy value from the original fuel. The technology is, however, still very controversial because of the increased cost and proliferation risk it can present. To lend perspective on the closed fuel cycle alternative, this presents the arguments for and against closing the fuel cycle with respect to sustainability, proliferation risk, commercial viability, waste management, and energy security.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ATLAS Status and First Results

After more than 20 years of continuous work and several months of commissioning with cosmic muon data, the ATLAS experiment started data taking at the Large Hadron Collider (CERN). From November 2009 to May 2010, ATLAS registered proton-proton collisions at 900 GeV, 2.36 GeV and finally 7 TeV center of mass energy. These data samples have been used to study the detector performance in detail and are currently being used also for the first physics studies. In this document, we present some selected physics and performance results obtained with the first 7 TeV proton-proton collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Features Of The J-PARC Linac

Japan Proton Accelerator Research Complex (J-PARC) will be one of the highest intensity proton accelerators in the world aiming to realize 1 MW class of the beam power. The accelerator consists of a 400-MeV linac, a 3-GeV rapid-cycling synchrotron (RCS) and a main ring synchrotron (MR), and the accelerated beam is applied to several experimental facilities. The linac, which is the injector for the RCS, has about 50 cavity modules to accelerate the beam up to 400 MeV. The acceleration field error in all of them should be within {+-}1% in amplitude and {+-}1 degree in phase because the momentum spread of the RCS injection beam is required to be within 0.1%. For the cavity field stabilization, a high-stable optical signal distribution system is used as the RF reference, and sophisticated digital feedback and feed-forward system is working well in the low level RF control system. Consequently the providing beam to the RCS is very stable, and the beam commissioning and the experiments of the application facilities have been progressed steadily.

43 PARTICLE ACCELERATORS↗

J-PARC Status, Nuclear and Particle Physics

J-PARC accelerator research complex, consisting of LINAC, RCS and MR synchrotron, has successfully produced neutron, muons, kaons, and neutrinos by steady commissioning since November 2006. There are three experimental facilities, and for nuclear and particle physics, nine experiments are approved in a hadron physics facility, and one experiment is approved in a neutrino physics facility. Those experiments and status of J-PARC are described in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Soft X-ray Spectromicroscopy Beamline at SSRF

Commissioning of the soft x-ray spectromicroscopy beanmline at SSRF was formally started on Dec 26, 2008. Beamline performance has reached or surpassed the designing goals according to the measurements by domestic experts, especially for its high energy resolution and high spatial resolution. Since its first operation by users on May 6, 2009, tens of experiments have been conducted, and some preliminary exciting results have been acquired.

07 ISOTOPE AND RADIATION SOURCES↗

MUSETT and the Spectroscopy of Heavy Elements at GANIL

The new MUSETT silicon-wall has been built to study and obtain detailed spectroscopic information on the transfermium and transactinide elements. MUSETT is located at GANIL at the detection plane of VAMOS, the latter coupled with the EXOGAM germanium array. Results from the in-beam commissioning are reported and an overview of our future experimental program will be given.

43 PARTICLE ACCELERATORS↗

RAMI Analyses of Heating Neutral Beam and Diagnostic Neutral Beam Systems for ITER

A RAMI (Reliability, Availability, Maintainability, Inspectability) analysis has been performed for the heating (and current drive) neutral beam (HNB) and diagnostic neutral beam (DNB) systems of the ITER device. The objective of these analyses is to implement RAMI engineering requirements for design and testing to prepare a reliability-centred plan for commissioning, operation, and maintenance of the system in the framework of technical risk control to support the overall ITER Project. These RAMI requirements will correspond to the RAMI targets for the ITER project and the compensating provisions to reach them as deduced from the necessary actions to decrease the risk level of the function failure modes. The RAMI analyses results have to match with the procurement plan of the systems.

43 PARTICLE ACCELERATORS↗

A Versatile Ion Injector at KACST

A versatile ion-beam injector is presently being constructed at the National Centre for Mathematics and Physics (NCMP) at the King Abdul-Aziz City for Science and Technology (KACST), Saudi Arabia. This versatile injector will provide an electrostatic storage ring with high-quality ion beams of energies up to 30 keV per charge q. It will also allow for crossed-beams experiments in single-pass setups. The injector has been designed to include beams from two different ion sources, switched by a 90 deg. deflection setup, and to allow for matching of the beam parameters to the Twiss parameters of the ring. The injector is equipped with two crossed beam-lines (inlets), with duplicated beam extraction and acceleration systems. As part of the initial setup, a simple electric discharge ion source has been developed for commissioning of the whole injector. In this paper, we report on the ion optics layout and the design parameters of the injector.

43 PARTICLE ACCELERATORS↗

Invited Article: Coherent imaging using seeded free-electron laser pulses with variable polarization: First results and research opportunities

FERMI-Elettra, the first vacuum ultraviolet and soft X-ray free-electron laser (FEL) using by default a 'seeded' scheme, became operational in 2011 and has been opened to users since December 2012. The parameters of the seeded FERMI FEL pulses and, in particular, the superior control of emitted radiation in terms of spectral purity and stability meet the stringent requirements for single-shot and resonant coherent diffraction imaging (CDI) experiments. The advantages of the intense seeded FERMI pulses with variable polarization have been demonstrated with the first experiments performed using the multipurpose experimental station operated at the diffraction and projection imaging (DiProI) beamline. The results reported here were obtained with fixed non-periodic targets during the commissioning period in 2012 using 20-32 nm wavelength range. They demonstrate that the performance of the FERMI FEL source and the experimental station meets the requirements of CDI, holography, and resonant magnetic scattering in both multi- and single-shot modes. Moreover, we present the first magnetic scattering experiments employing the fully circularly polarized FERMI pulses. The ongoing developments aim at pushing the lateral resolution by using shorter wavelengths provided by double-stage cascaded FERMI FEL-2 and probing ultrafast dynamic processes using different pump-probe schemes, including jitter-free seed laser pump or FEL-pump/FEL-probe with two color FEL pulses generated by the same electron bunch.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Spectral motional Stark effect diagnostic for measurement of magnetic fields below 0.3 T

The paper reports on development of the spectral motional Stark effect (MSE) diagnostic in the midplane of the gas dynamic trap (GDT) linear system for magnetic confinement of anisotropic hot-ion plasma. The axially symmetric GDT vacuum magnetic field has a minimum value in the midplane, which varies from 0.2 to 0.35 T in different regimes of operation. Buildup of 15 keV ion population generates a diamagnetic reduction of magnetic field in the plasma core of up to 30% in the maximum density region, as measured by the existing eight-line MSE diagnostic. Commissioning of the midplane MSE provided first direct measurements of diamagnetic modifications in the minimum magnetic field GDT section, a necessary complement to the understanding of equilibrium and self-organization of high-β plasmas in GDT. Making use of the stable short-pulse diagnostic beam and calibration of the apparent spectral width of beam emission lines allow for the measurement of the plasma magnetic field of 0.29 ± 0.007 T with the integration time of 200 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of a room temperature electron cyclotron resonance ion source using evaporative cooling technology at Institute of Modern Physics

A new room temperature ECR ion source, Lanzhou Electron Cyclotron Resonance ion source No. 4 (LECR4, previously named DRAGON), is under intense construction at Institute of Modern Physics. LECR4 is designed to operate with 18 GHz microwave frequency. The maximum axial magnetic fields are 2.3 T at injection and 1.3 T at extraction, and the radial field at the plasma chamber wall of 76 mm inner diameter is 1.0–1.2 T. One of the unique features for LECR4 is that its axial solenoids are winded with solid square copper wires which are immersed in a kind of special evaporative cooling medium for cooling purpose. Till now, a prototype of the cooling system has been successfully constructed and tested, which has demonstrated that the cooling efficiency of the designed system could meet the requirements of LECR4 under the routine operation conditions. All the main components of the ion source have been completed. Assembly and commissioning is ongoing. The latest developments and test results will be presented in this paper.