Intrinsic torque reversals induced by magnetic shear effects on the turbulence spectrum in tokamak plasmas

Intrinsic torque, which can be generated by turbulent stresses, can induce toroidal rotation in a tokamak plasma at rest without direct momentum injection. Reversals in intrinsic torque have been inferred from the observation of toroidal velocity changes in recent lower hybrid current drive (LHCD) experiments. This work focuses on understanding the cause of LHCD-induced intrinsic torque reversal using gyrokinetic simulations and theoretical analyses. A new mechanism for the intrinsic torque reversal linked to magnetic shear (s{sup ^}) effects on the turbulence spectrum is identified. This reversal is a consequence of the ballooning structure at weak s{sup ^}. Based on realistic profiles from the Alcator C-Mod LHCD experiments, simulations demonstrate that the intrinsic torque reverses for weak s{sup ^} discharges and that the value of s{sup ^}{sub crit} is consistent with the experimental results s{sup ^}{sub crit}{sup exp}≈0.2∼0.3 [Rice et al., Phys. Rev. Lett. 111, 125003 (2013)]. The consideration of this intrinsic torque feature in our work is important for the understanding of rotation profile generation at weak s{sup ^} and its consequent impact on macro-instability stabilization and micro-turbulence reduction, which is crucial for ITER. It is also relevant to internal transport barrier formation at negative or weakly positive s{sup ^}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous transport in the H-mode pedestal of Alcator C-Mod discharges

Anomalous transport in the H-mode pedestal region of five Alcator C-Mod discharges, representing a collisionality scan is analyzed. The understanding of anomalous transport in the pedestal region is important for the development of a comprehensive model for the H-mode pedestal slope. In this research, a possible role of the drift resistive inertial ballooning modes (Rafiq et al 2010 Phys. Plasmas 17 082511) in the edge of Alcator C-Mod discharges is analyzed. The stability analysis, carried out using the TRANSP code, indicates that the DRIBM modes are strongly unstable in Alcator C-Mod discharges with large electron collisionality. An improved interpretive analysis of H-mode pedestal experimental data is carried out utilizing the additive flux minimization technique (Pankin et al 2013 Phys. Plasmas 20 102501) together with the guiding-center neoclassical kinetic XGC0 code. The neoclassical and neutral physics are simulated in the XGC0 code and the anomalous fluxes are computed using the additive flux minimization technique. The anomalous fluxes are reconstructed and compared with each other for the collisionality scan Alcator C-Mod discharges. It is found that the electron thermal anomalous diffusivities at the pedestal top increase with the electron collisionality. This dependence can also point to the drift resistive inertial ballooning modes as the modes that drive the anomalous transport in the plasma edge of highly collisional discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriform sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

280 GHz Focal Plane Unit Design and Characterization for the Spider-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne Spider instrument. These FPUs are vital to Spider’s primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a $16 \times 16$ grid of corrugated silicon feedhorns coupled to an array of aluminum–manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be $\sim $ 3 pW at 300 mK with a less than 6% variation across each array at $1\sigma $ . These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the Spider-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BISON validation to in situ cladding burst test and high-burnup LOCA experiments

The process for developing and qualifying nuclear fuels for commercial nuclear application requires fundamental material development, characterization, and design; out-of-pile testing on unirradiated materials; integral fuel rod irradiations, testing, and postirradiation examinations; and transient analyses. The historical approach depends on the generation of large empirical datasets and series of integral fuel rod irradiations, and this approach ultimately takes ~20 years—or sometimes longer—to acquire data through extensive sequential testing. Thus, the qualification and eventual deployment of new fuel systems constitute a long process. However, recent technological advancements have provided researchers the opportunity to perform out-of-cell, in situ measurements to assess material performance for the duration of the experiment. One such example of this capability is the use of digital image coordination and thermal imaging to assess Zircaloy cladding performance under a simulated loss-of-coolant accident (LOCA) transient condition. In situ measurements generally provide high-fidelity strain, strain rates, and temperature surface maps. This is critical for the US nuclear industry, which is actively developing a technical basis to support extending the peak rod average burnup from 62 to ~75 GWd/tU and the deployment of accident-tolerant fuel. However, the US Nuclear Regulatory Commission (NRC) outlined in its research information letter several technical issues that the industry must address before extending burnup. One topic of specific interest is understanding the cladding balloon and rupture geometry during the LOCA heat-up phase. By leveraging these advanced in situ capabilities, this work used in situ data generated from a simulated LOCA to better understand high-temperature creep and its effect on Zircaloy balloon and rupture performance. Here, this work used the BISON fuel performance code to assess the high-temperature creep model predictions with in situ data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cosmic antihelium-3 nuclei sensitivity of the GAPS experiment

The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1-0.3 GeV/n) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based on the formation, decay, and annihilation of exotic atoms, provides greater identification power for these low-energy antinuclei than previous magnetic spectrometer experiments. This work reports the sensitivity of GAPS to detect antihelium-3 nuclei, based on full instrument simulation, event reconstruction, and realistic atmospheric influence simulations. The report of antihelium nuclei candidate events by AMS-02 has generated considerable interest in antihelium nuclei as probes of dark matter and other beyond the Standard Model theories. GAPS is in a unique position to detect or set upper limits on the cosmic antihelium nuclei flux in an energy range that is essentially free of astrophysical background. In three 35-day long-duration balloon flights, GAPS will be sensitive to an antihelium flux on the level of $1.3^{+4.5}_{-1.2} $ ∙ 10 -6 m -2 sr -1 s -1 (GeV/n) -1 (95% confidence level) in the energy range of 0.11-0.3 GeV/n, opening a new window on rare cosmic physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atmospheric pion, kaon, and muon fluxes for sub-orbital experiments

Cosmic rays interacting with the Earth's atmosphere generate extensive air showers, which produce Cherenkov, fluorescence and radio emissions. These emissions are key signatures for detection by ground-based, sub-orbital, and satellite-based telescopes aiming to study high energy cosmic ray and neutrino events. However, detectors operating at ground and balloon altitudes are also exposed to a background of atmospheric charged particles, primarily pions, kaons, and muons, that can mimic or obscure the signals from astrophysical sources. In this work, we use coupled cascade equations to calculate the atmospheric pion, kaon and muon fluxes reaching detectors at various altitudes. Our analysis focuses on energies above 10 GeV, where the influence of the Earth's magnetic field on particle trajectories is minimal. We provide angular and energy-resolved flux estimates and discuss their relevance as background for extensive air shower detection. Furthermore, our results are potentially relevant for interpreting data from current and future balloon-borne experiments such as EUSO-SPB2 and for refining trigger and veto strategies in Cherenkov and fluorescence telescopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intracoronary artery transplantation of cardiomyoblast-like cells from human adipose tissue-derived multi-lineage progenitor cells improve left ventricular dysfunction and survival in a swine model of chronic myocardial infarction

Highlights: Black-Right-Pointing-Pointer We administered human CLCs in a swine model of MI via intracoronary artery. Black-Right-Pointing-Pointer Histological studies demonstrated engraftment of hCLCs into the scarred myocardium. Black-Right-Pointing-Pointer Echocardiography showed rescue of cardiac function in the hCLCs transplanted swine. Black-Right-Pointing-Pointer Transplantation of hCLCs is an effective therapeutics for cardiac regeneration. -- Abstract: Transplantation of human cardiomyoblast-like cells (hCLCs) from human adipose tissue-derived multi-lineage progenitor cells improved left ventricular function and survival of rats with myocardial infarction. Here we examined the effect of intracoronary artery transplantation of human CLCs in a swine model of chronic heart failure. Twenty-four pigs underwent balloon-occlusion of the first diagonal branch followed by reperfusion, with a second balloon-occlusion of the left ascending coronary artery 1 week later followed by reperfusion. Four weeks after the second occlusion/reperfusion, 17 of the 18 surviving animals with severe chronic MI (ejection fraction <35% by echocardiography) were immunosuppressed then randomly assigned to receive either intracoronary artery transplantation of hCLCs hADMPCs or placebo lactic Ringer's solution with heparin. Intracoronary artery transplantation was followed by the distribution of DiI-stained hCLCs into the scarred myocardial milieu. Echocardiography at post-transplant days 4 and 8 weeks showed rescue and maintenance of cardiac function in the hCLCs transplanted group, but not in the control animals, indicating myocardial functional recovery by hCLCs intracoronary transplantation. At 8 week post-transplantation, 7 of 8 hCLCs transplanted animals were still alive compared with only 1 of the 5 control (p = 0.0147). Histological studies at week 12 post-transplantation demonstrated engraftment of the pre DiI-stained hCLCs into the scarred myocardium and their expression of human specific alpha-cardiac actin. Human alpha cardiac actin-positive cells also expressed cardiac nuclear factors; nkx2.5 and GATA-4. Our results suggest that intracoronary artery transplantation of hCLCs is a potentially effective therapeutic strategy for future cardiac tissue regeneration.

60 APPLIED LIFE SCIENCES↗

Failure of brittle micro-spherical shells embedded in elastomer matrix under indentation

Silicone elastomer filled with glass micro balloons (GMB) is an elastomeric syntactic foam used in electronics and component packaging for encapsulation, potting, stress-relief layer, and electrical insulation purposes. Under mechanical loading, the reinforcing phase, namely the GMBs embedded in the elastomer matrix, may break or delaminate, leading to internal damage and macroscale stiffness degradation, which can alter the material's protective capacity against mechanical shock and vibration. The degree of damage is controlled by the loading history, delamination, and failure behavior of the GMBs. In this work, we investigate the GMB failure behavior in this work wherein we present an indentation experiment to measure the force required to fail individual GMBs that are either embedded in the elastomer matrix or adhered to the surface of an elastomer layer. The indentation apparatus is augmented with an inverted optical microscope to enable in situ imaging of the GMB. Failure modes for the embedded or non-embedded GMBs are discussed based on the morphology of the broken GMBs and the measured failure forces. We also measure the adhesion energy between the glass balloon and the elastomer, based on which the possibility of delamination between the GMB and the surrounding elastomer matrix during the failure process is evaluated. Our results can facilitate the development of a failure criterion of GMBs which is necessary for establishing a physics-based constitutive model to describe the macroscopic damage mechanics of elastomeric syntactic foams.

42 ENGINEERING↗

Impact of Heterogeneity-Based Dose Calculation Using a Deterministic Grid-Based Boltzmann Equation Solver for Intracavitary Brachytherapy

Purpose: To investigate the dosimetric impact of the heterogeneity dose calculation Acuros (Transpire Inc., Gig Harbor, WA), a grid-based Boltzmann equation solver (GBBS), for brachytherapy in a cohort of cervical cancer patients. Methods and Materials: The impact of heterogeneities was retrospectively assessed in treatment plans for 26 patients who had previously received {sup 192}Ir intracavitary brachytherapy for cervical cancer with computed tomography (CT)/magnetic resonance-compatible tandems and unshielded colpostats. The GBBS models sources, patient boundaries, applicators, and tissue heterogeneities. Multiple GBBS calculations were performed with and without solid model applicator, with and without overriding the patient contour to 1 g/cm{sup 3} muscle, and with and without overriding contrast materials to muscle or 2.25 g/cm{sup 3} bone. Impact of source and boundary modeling, applicator, tissue heterogeneities, and sensitivity of CT-to-material mapping of contrast were derived from the multiple calculations. American Association of Physicists in Medicine Task Group 43 (TG-43) guidelines and the GBBS were compared for the following clinical dosimetric parameters: Manchester points A and B, International Commission on Radiation Units and Measurements (ICRU) report 38 rectal and bladder points, three and nine o'clock, and {sub D2cm3} to the bladder, rectum, and sigmoid. Results: Points A and B, D{sub 2} cm{sup 3} bladder, ICRU bladder, and three and nine o'clock were within 5% of TG-43 for all GBBS calculations. The source and boundary and applicator account for most of the differences between the GBBS and TG-43 guidelines. The D{sub 2cm3} rectum (n = 3), D{sub 2cm3} sigmoid (n = 1), and ICRU rectum (n = 6) had differences of >5% from TG-43 for the worst case incorrect mapping of contrast to bone. Clinical dosimetric parameters were within 5% of TG-43 when rectal and balloon contrast were mapped to bone and radiopaque packing was not overridden. Conclusions: The GBBS has minimal impact on clinical parameters for this cohort of patients with unshielded applicators. The incorrect mapping of rectal and balloon contrast does not have a significant impact on clinical parameters. Rectal parameters may be sensitive to the mapping of radiopaque packing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry

Purpose: We performed a dosimetry analysis to determine how well the goals for clinical target volume coverage, dose homogeneity, and normal tissue dose constraints were achieved with high-dose-rate (HDR) prostate brachytherapy. Methods and Materials: Cumulative dose-volume histograms for 208 consecutively treated HDR prostate brachytherapy implants were analyzed. Planning was based on ultrasound-guided catheter insertion and postoperative CT imaging; the contoured clinical target volume (CTV) was the prostate, a small margin, and the proximal seminal vesicles. Dosimetric parameters analyzed for the CTV were D90, V90, V100, V150, and V200. Dose to the urethra, bladder, bladder balloon, and rectum were evaluated by the dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} of each organ, expressed as a percentage of the prescribed dose. Analysis was stratified according to prostate size. Results: The mean prostate ultrasound volume was 38.7 {+-} 13.4 cm{sup 3} (range: 11.7-108.6 cm{sup 3}). The mean CTV was 75.1 {+-} 20.6 cm{sup 3} (range: 33.4-156.5 cm{sup 3}). The mean D90 was 109.2% {+-} 2.6% (range: 102.3%-118.4%). Ninety-three percent of observed D90 values were between 105 and 115%. The mean V90, V100, V150, and V200 were 99.9% {+-} 0.05%, 99.5% {+-} 0.8%, 25.4% {+-} 4.2%, and 7.8% {+-} 1.4%. The mean dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} for organs at risk were: Urethra: 107.3% {+-} 3.0%, 101.1% {+-} 14.6%, and 47.9% {+-} 34.8%; bladder wall: 79.5% {+-} 5.1%, 69.8% {+-} 4.9%, and 64.3% {+-} 5.0%; bladder balloon: 70.3% {+-} 6.8%, 59.1% {+-} 6.6%, and 52.3% {+-} 6.2%; rectum: 76.3% {+-} 2.5%, 70.2% {+-} 3.3%, and 66.3% {+-} 3.8%. There was no significant difference between D90 and V100 when stratified by prostate size. Conclusions: HDR brachytherapy allows the physician to consistently achieve complete prostate target coverage and maintain normal tissue dose constraints for organs at risk over a wide range of target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The first transport code simulations using the trapped gyro-Landau-fluid model

The first transport code simulations using the newly developed trapped gyro-Landau-fluid (TGLF) theory-based transport model are presented. TGLF has comprehensive physics to approximate the turbulent transport due to drift-ballooning modes in tokamaks. The TGLF model is a next generation gyro-Landau-fluid model that improves the accuracy of the trapped particle response and the finite Larmor radius effects compared to its predecessor, GLF23. The model solves for the linear eigenmodes of trapped ion and electron modes, ion and electron temperature gradient modes, and electromagnetic kinetic ballooning modes in either shifted circle or shaped geometry. A database of over 400 nonlinear gyrokinetic simulations using the GYRO code has been created. A subset of 83 simulations with shaped geometry has been used to find a model for the saturation levels. Using a simple quasilinear (QL) saturation rule, remarkable agreement with the energy and particle fluxes from a wide variety of GYRO simulations is found for both shaped or circular geometry and also for low aspect ratio. Using this new QL saturation rule along with a new ExB shear quench rule for shaped geometry, the density and temperature profiles have been predicted in over 500 transport code runs and the results compared against experimental data from 96 tokamak discharges. Compared to GLF23, the TGLF model demonstrates better agreement between the predicted and experimental temperature profiles. Surprisingly, TGLF predicts that the high-k modes are found to play an important role in the central core region of low and high confinement plasmas lacking transport barriers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Loss of confinement at the density limit due to the suppression of stabilizing zonal flows by magnetic turbulence

The character of particle and energy transport in numerical simulations of drift-ballooning turbulence changes dramatically as the density exceeds a critical limit. When the density is not too large, then unstable drift-ballooning fluctuations grow and nonlinearly generate a sheared zonal (flux surface averaged) flow that saturates the turbulence. But when diamagnetic drift effects are small and the density increases beyond a critical limit, then the turbulent density flux increases monotonically in time to large values without saturation. This loss of confinement is caused by the suppression of the stabilizing zonal flow by the magnetic component of the turbulence. A Kelvin-Helmholtz-like shear-flow instability does not play any role in reducing the magnitude of the zonal flow. The magnetic turbulence prevents the zonal flow from growing large enough to become shear-flow unstable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic turbulence simulations at high plasma beta

Electromagnetic gyrokinetic turbulence simulations employing Cyclone Base Case parameters are presented for {beta} values up to and beyond the kinetic ballooning threshold. The {beta} scaling of the turbulent transport is found to be linked to a complex interplay of linear and nonlinear effects. Linear investigation of the kinetic ballooning mode is performed in detail, while nonlinearly, it is found to dominate the turbulence only in a fairly narrow range of {beta} values just below the respective ideal limit. The magnetic transport scales like {beta}{sup 2} and is well described by a Rechester-Rosenbluth-type ansatz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global particle-in-cell simulations of plasma pressure effects on Alfvenic modes

Global linear gyrokinetic particle-in-cell simulations of electromagnetic modes in realistic tokamak geometry are reported. The effect of plasma pressure on Alfvenic modes is studied. It is shown that the fast-particle pressure can considerably affect the shear Alfven wave continuum structure and hence the toroidicity-induced gap in the continuum. It is also found that the energetic ions can substantially reduce the growth rate of the ballooning modes (and perhaps completely stabilize them in a certain parameter range). Ballooning modes are found to be the dominant instabilities if the bulk-plasma pressure gradient is large enough.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H-mode pedestal scaling in DIII-D, ASDEX Upgrade, and JET

Multidevice pedestal scaling experiments in the DIII-D, ASDEX Upgrade (AUG), and JET tokamaks are presented in order to test two plasma physics pedestal width models. The first model proposes a scaling of the pedestal width {Delta}/a {proportional_to} {rho}*{sup 1/2} to {rho}* based on the radial extent of the pedestal being set by the point where the linear turbulence growth rate exceeds the ExB velocity. In the multidevice experiment where {rho}* at the pedestal top was varied by a factor of four while other dimensionless parameters where kept fixed, it has been observed that the temperature pedestal width in real space coordinates scales with machine size, and that therefore the gyroradius scaling suggested by the model is not supported by the experiments. The density pedestal width is not invariant with {rho}* which after comparison with a simple neutral fuelling model may be attributed to variations in the neutral fuelling patterns. The second model, EPED1, is based on kinetic ballooning modes setting the limit of the radial extent of the pedestal region and leads to {Delta}{sub {psi} {proportional_to}} {beta}{sub p}{sup 1/2}. All three devices show a scaling of the pedestal width in normalised poloidal flux as {Delta}{sub {psi} {proportional_to}} {beta}{sub p}{sup 1/2}, as described by the kinetic ballooning model; however, on JET and AUG, this could not be distinguished from an interpretation where the pedestal is fixed in real space. Pedestal data from all three devices have been compared with the predictive pedestal model EPED1 and the model produces pedestal height values that match the experimental data well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The EPED pedestal model and edge localized mode-suppressed regimes: Studies of quiescent H-mode and development of a model for edge localized mode suppression via resonant magnetic perturbations

The EPED model predicts the H-mode pedestal height and width based upon two fundamental and calculable constraints: (1) onset of non-local peeling-ballooning modes at low to intermediate mode number, (2) onset of nearly local kinetic ballooning modes at high mode number. We present detailed tests of the EPED model in discharges with edge localized modes (ELMs), employing new high resolution measurements, and finding good quantitative agreement across a range of parameters. The EPED model is then applied for the first time to quiescent H-mode (QH), finding a similar level of agreement between predicted and observed pedestal height and width, and suggesting that the model can be used to predict the critical density for QH-mode operation. Finally, the model is applied toward understanding the suppression of ELMs with 3D resonant magnetic perturbations (RMP). Combining EPED with plasma response physics, a new working model for RMP ELM suppression is developed. We propose that ELMs are suppressed when a 'wall' associated with the RMP blocks the inward penetration of the edge transport barrier. A calculation of the required location of this 'wall' with EPED is consistent with observed profile changes during RMP ELM suppression and offers an explanation for the observed dependence on safety factor (q{sub 95}).