Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Parametric study of high-energy ring-shaped electron beams from a laser wakefield accelerator

Abstract Laser wakefield accelerators commonly produce on-axis, low-divergence, high-energy electron beams. However, a high charge, annular shaped beam can be trapped outside the bubble and accelerated to high energies. Here we present a parametric study on the production of low-energy-spread, ultra-relativistic electron ring beams in a two-stage gas cell. Ring-shaped beams with energies higher than 750 MeV are observed simultaneously with on axis, continuously injected electrons. Often multiple ring shaped beams with different energies are produced and parametric studies to control the generation and properties of these structures were conducted. Particle tracking and particle-in-cell simulations are used to determine properties of these beams and investigate how they are formed and trapped outside the bubble by the wake produced by on-axis injected electrons. These unusual femtosecond duration, high-charge, high-energy, ring electron beams may find use in beam driven plasma wakefield accelerators and radiation sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam dynamics challenges in linear colliders based on laser-plasma accelerators

In this paper we discuss design considerations and beam dynamics challenges associated with laser-driven plasma-based accelerators as applied to multi-TeV-scale linear colliders. Plasma accelerators provide ultra-high gradients and ultra-short bunches, offering the potential for compact linacs and reduced power requirements. We show that stable, efficient acceleration with beam quality preservation is possible in the nonlinear bubble regime of laser-plasma accelerators using beam shaping. Ion motion, naturally occuring for dense beams (i.e., low emittance and high energy) severely damps transverse beam instabilities. Coulomb scattering by the background ions is considered and it is shown that the strong focusing in the plasma strongly suppresses scattering-induced emittance growth. Finally, Betatron radiation emission from the transverse motion of the beam in the plasma will result in beam power loss and energy spread growth; however for sub-100 nm emittances, the beam power loss and energy spread growth will be sub-percent for multi-TeV-class plasma linacs.

47 OTHER INSTRUMENTATION↗

Propagation of an asymmetric Gaussian beam in a nonlinear absorbing medium

Propagation of an asymmetric Gaussian beam in a cubic-quintic absorbing medium is analyzed and compared with that of a symmetric beam in both lossless and lossy media. A 'collective variable approach' technique, based on trial functions, is used for solution of the general nonlinear Schroedinger equation. Using this variational approach, we investigate the self-focusing and breathing of an intense asymmetric Gaussian beam, taking into account both linear and nonlinear absorption. For a lossless medium, we define regions of oscillatory and diffractive beam propagation, for both symmetric and asymmetric beams. In particular, for an asymmetric beam, we find that there is no sharp boundary between the oscillatory self-focusing and oscillatory diffractive regimes of propagation. In the oscillatory region, we detect an interesting phenomenon -'beats' of the amplitude and perpendicular widths of the beam. For a lossy medium, significant differences between the amplitudes, widths, and phases of the symmetric and asymmetric beams have been predicted.

97 MATHEMATICS AND COMPUTING↗

Variational Self-Consistent Theory for Beam-Loaded Cavities

A new variational theory is presented for beam loading in microwave cavities. The beam{field interaction is formulated as a dynamical interaction whose stationarity according to Hamilton’s principle will naturally lead to steady-state solutions that indicate how a cavity’s resonant frequency, Q and optimal coupling coefficient will detune as a result of the beam loading. A driven cavity Lagrangian is derived from first principles, including the effects of cavity wall losses, input power and beam interaction. The general formulation is applied to a typical klystron input cavity to predict the appropriate detuning parameters required to maximize the gain (or modulation depth) in the average Lorentz factor boost, (Δ γ). Numerical examples are presented, showing agreement with the general detuning trends previously observed in the literature. The developed formulation carries several advantages for beam-loaded cavity structures. It provides a self-consistent model for the dynamical (nonlinear) beam{field interaction, a procedure for maximizing gain under beam-loading conditions, and a useful set of parameters to guide cavity-shape optimization during the design of beam-loaded systems. Enhanced clarity of the physical picture underlying the problem seems to be gained using this approach, allowing straightforward inclusion or exclusion of different field configurations in the calculation and expressing the final results in terms of measurable quantities. Two field configurations are discussed for the klystron input cavity, using finite magnetic confinement or no confinement at all. Formulating the problem in a language that is directly accessible to the powerful techniques found in Hamiltonian dynamics and canonical transformations may potentially carry an additional advantage in terms of analytical computational gains, under suitable conditions

43 PARTICLE ACCELERATORS↗

Experimental Generation of Extreme Electron Beams for Advanced Accelerator Applications

In this Letter, we report on the experimental generation of high energy (10 GeV), ultrashort (femtosecond-duration), ultrahigh current (∼ 0.1 MA), petawatt peak power electron beams in a particle accelerator. These extreme beams enable the exploration of a new frontier of high-intensity beam-light and beam-matter interactions broadly relevant across fields ranging from laboratory astrophysics to strong field quantum electrodynamics and ultrafast quantum chemistry. We demonstrate our ability to generate and control the properties of these electron beams by means of a laser-electron beam shaping technique. In conclusion, this experimental demonstration opens the door to on-the-fly customization of extreme beam current profiles for desired experiments and is poised to benefit a broad swath of cross-cutting applications of relativistic electron beams.

43 PARTICLE ACCELERATORS↗

Etching of Si 3 N 4 induced by electron beam plasma from hollow cathode plasma in a downstream reactive environment

An etching system based on the interaction of electrons extracted from a direct current (DC) hollow-cathode (HC) Ar plasma and injected towards a Si3N4 covered silicon substrate located in the downstream reactive environment created by an additional remote CF 4 /O 2 plasma source was developed and evaluated. By controlling the properties of the injected beam electrons, this approach allows to deliver energy to a surface functionalized by exposure to reactive species, and initiate surface etching. The energy of the primary beam electrons is controlled by the acceleration voltage relative to the HC discharge. Ar atoms flow from the high-pressure HC discharge into the low pressure downstream reactive environment in the process chamber. For an acceleration voltage greater than the ionization potential of Ar and/or process gas species, the energetic primary beam electrons produce a secondary plasma in the process chamber, and can also cause additional dissociation. We have characterized the properties of the secondary plasma and also surface etching of Si 3 N 4 as a function of process parameters, including acceleration voltage (0-80 V), discharge current of the HC discharge (1-2 A), pressure (3.5-20 mTorr), source to substrate distance (1.5 to 5 cm), and feed gas composition (20% and 80% O2 in CF 4 /O 2 ). The electron energy probability function (EEPF) measured with a Langmuir probe about 2.5 cm below the extraction ring suggests several major groups of electrons for this situation, including high energy primary beam electrons with an energy that varies as the acceleration voltage is changed and low energy electrons produced by beam electron-induced ionization of the Ar gas in the process chamber. When a remote CF 4 /O 2 plasma is additionally coupled to the process chamber, Si 3 N 4 surfaces can be functionalized, and by varying the energy of the beam electrons, Si 3 N 4 etching can be induced by electron-neutral synergy effect with plasma-surface interaction. For conditions without beam electron injection, the remote plasma etching rate (ER) of Si 3 N 4 depends strongly on the O 2 concentration in the CF 4 /O 2 processing gas mixture and can be suppressed for O 2 -rich process conditions by the formation of a SiONF passivation layer on the Si 3 N 4 surface. The combination of the HC electron beam source with the remote plasma source (HCEB-RP) makes it possible to induce Si 3 N 4 etching for O 2 -rich remote plasma conditions where remote plasma by itself produces negligible Si 3 N 4 etching. The electron enhanced etching of Si 3 N 4 depends strongly on O 2 /CF 4 mixing ratio reflecting changing arrival rates of O and F species at the surface. Optical emission spectroscopy was used to estimate the ratio of gas phase F and O densities and found to be controlled by the gas mixing ratio and independent of HC EB operating conditions. At this time the detailed sequence of events operative in the etching mechanism is unclear. While the increase of the electron energy is ultimately responsible for initiating surface etching, at present we cannot rule out a role of ions from the simultaneously produced secondary plasma in plasma surface interaction mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Replacement correction factors for cylindrical ion chambers in electron beams

Purpose: In the TG-21 dosimetry protocol, for cylindrical chambers in electron beams the replacement correction factor P{sub repl} (or the product p{sub dis}p{sub cav} in the IAEA's notation), was conceptually separated into two components: the gradient correction (P{sub gr}) accounting for the effective point of measurement and the fluence correction (P{sub fl}) dealing with the change in the electron fluence spectrum. At the depth of maximum dose (d{sub max}), P{sub gr} is taken as 1. There are experimental data available at d{sub max} for the values of P{sub fl} (or P{sub repl}). In the TG-51 dosimetry protocol, the calibration is at the reference depth d{sub ref}=0.6R{sub 50}-0.1 (cm) where P{sub gr} is required for cylindrical chambers and P{sub fl} is unknown and so the measured values at d{sub max} are used with the corresponding mean electron energy at d{sub ref}. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for cylindrical chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} and P{sub fl} are calculated with high statistical precision (<0.1%) for cylindrical cavities of a variety of diameters and lengths in a water phantom irradiated by various electron beams. The values of P{sub gr} as defined in the TG-51 dosimetry protocol are also calculated. Results: The calculated values of the fluence correction factors P{sub fl} are in good agreement with the measured values when the wall correction factors are taken into account for the plane-parallel chambers used in the measurements. An empirical formula for P{sub fl} for cylindrical chambers at d{sub ref} in electron beams is derived as a function of the chamber radius and the beam quality specifier R{sub 50}. Conclusions: The mean electron energy at depth is a good beam quality specifier for P{sub fl}. Thus TG-51's adoption of P{sub fl} at d{sub max} with the same mean electron energy for use at d{sub ref} is proven to be accurate. The values of P{sub gr} for a Farmer-type chamber as defined in the TG-51 dosimetry protocol may be wrong by 0.3% for high-energy electron beams and by more than 1% for low-energy electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum

Purpose: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. Methods: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. Results: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. Conclusions: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replacement correction factors for plane-parallel ion chambers in electron beams

Purpose: Plane-parallel chambers are recommended by dosimetry protocols for measurements in (especially low-energy) electron beams. In dosimetry protocols, the replacement correction factor P{sub repl} is assumed unity for ''well-guarded'' plane-parallel chambers in electron beams when the front face of the cavity is the effective point of measurement. There is experimental evidence that ion chambers which are not well-guarded (e.g., Markus) have nonunity P{sub repl} values. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for plane-parallel chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} are calculated with high statistical precision for the cavities of a variety of plane-parallel chambers in a water phantom irradiated by various electron beams. The dependences of the values of P{sub repl} on the beam quality, phantom depth, as well as the guard ring width are studied. Results: In the dose fall-off region for low-energy beams, the P{sub repl} values are very sensitive to depth. It is found that this is mainly due to the gradient effect, which originates from the fact that the effective point of measurement for many plane-parallel chambers should not be at the front face of the cavity but rather shifted toward the center of the cavity by a fraction of a millimeter. Using the front face of the cavity as the effective point of measurement, the calculated values of P{sub repl} at d{sub ref} are not unity for some well-guarded plane-parallel chambers. The calculated P{sub repl} values for the Roos chamber are close to 1 for all electron beams. The calculation results for the Markus chamber are in good agreement with the measured values. Conclusions: The appropriate selection of the effective point of measurement for plane-parallel chambers in electron beams is an important issue. If the effective point of measurement is correctly accounted for, the P{sub repl} values would be almost independent of depth. Both the guard ring width and the ratio of the collecting volume diameter to the cavity thickness can influence the values of P{sub repl}. For a diameter to thickness ratio of 5 (e.g., NACP02 chamber), the guard width has to be 6 mm for the chamber to be considered as well-guarded, i.e., have a P{sub repl} value of 1.00.

61 RADIATION PROTECTION AND DOSIMETRY↗

Oblique incidence for broad monoenergetic proton beams

Purpose: The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial Gaussian angular distribution. Methods: The Bortfeld model of depth dose in a broad normally incident proton beam has been extended to the case of oblique incidence. This extension uses an empirically determined Gaussian parameter {sigma}{sub x} which (roughly) characterizes the off-axis dose of a proton pencil beam. As with Bortfeld's work, the modeling is done in terms of parabolic cylinder functions. To obtain the depth dose for an initial angular distribution, the result is integrated over the angle of incidence, weighted by a Gaussian probability function. The predictions of the theory have been compared to MCNPX Monte Carlo calculations for four phantom materials (water, bone, aluminum, and copper) and for initial proton energies of 50, 100, 150, 200, and 250 MeV. Results: Comparisons of the depth dose predicted by this theory with Monte Carlo calculations have established that with very good accuracy, {sigma}{sub x} can be taken to be independent both of the depth and of the angle of incidence. As a function of initial proton range or of initial proton energy, {sigma}{sub x} has been found to obey a power law to very high accuracy. Good fits to Monte Carlo calculations have also been found for an initial Gaussian angular distribution. Conclusions: This investigation is the first step in the accurate modeling of a proton pencil beam with initial Gaussian angular distribution. It provides the longitudinal factor, with its Bragg peak buildup and sharp distal falloff. A transverse factor must still be incorporated into this theory and this will give the lateral penumbra of a collimated proton beam. Also, it will be necessary to model the dose of product particles from nuclear interactions of the proton beam. With the accurate modeling of a pencil beam, it will be possible to accurately take into account the effect of localized tissue inhomogeneities.

60 APPLIED LIFE SCIENCES↗

Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery

Purpose: The curative potential of external beam radiation therapy is critically dependent on having the ability to accurately aim radiation beams at intended targets while avoiding surrounding healthy tissues. However, existing technologies are incapable of real-time, volumetric, soft-tissue imaging during radiation beam delivery, when accurate target tracking is most critical. The authors address this challenge in the development and evaluation of a novel, minimally interfering, telerobotic ultrasound (U.S.) imaging system that can be integrated with existing medical linear accelerators (LINACs) for therapy guidance. Methods: A customized human-safe robotic manipulator was designed and built to control the pressure and pitch of an abdominal U.S. transducer while avoiding LINAC gantry collisions. A haptic device was integrated to remotely control the robotic manipulator motion and U.S. image acquisition outside the LINAC room. The ability of the system to continuously maintain high quality prostate images was evaluated in volunteers over extended time periods. Treatment feasibility was assessed by comparing a clinically deployed prostate treatment plan to an alternative plan in which beam directions were restricted to sectors that did not interfere with the transabdominal U.S. transducer. To demonstrate imaging capability concurrent with delivery, robot performance and U.S. target tracking in a phantom were tested with a 15 MV radiation beam active. Results: Remote image acquisition and maintenance of image quality with the haptic interface was successfully demonstrated over 10 min periods in representative treatment setups of volunteers. Furthermore, the robot's ability to maintain a constant probe force and desired pitch angle was unaffected by the LINAC beam. For a representative prostate patient, the dose-volume histogram (DVH) for a plan with restricted sectors remained virtually identical to the DVH of a clinically deployed plan. With reduced margins, as would be enabled by real-time imaging, gross tumor volume coverage was identical while notable reductions of bladder and rectal volumes exposed to large doses were possible. The quality of U.S. images obtained during beam operation was not appreciably degraded by radiofrequency interference and 2D tracking of a phantom object in U.S. images obtained with the beam on/off yielded no significant differences. Conclusions: Remotely controlled robotic U.S. imaging is feasible in the radiotherapy environment and for the first time may offer real-time volumetric soft-tissue guidance concurrent with radiotherapy delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Empirical binary tomography calibration (EBTC) for the precorrection of beam hardening and scatter for flat panel CT

Purpose: Scatter and beam hardening are prominent artifacts in x-ray CT. Currently, there is no precorrection method that inherently accounts for tube voltage modulation and shaped prefiltration. Methods: A method for self-calibration based on binary tomography of homogeneous objects, which was proposed by B. Li et al. [''A novel beam hardening correction method for computed tomography,'' in Proceedings of the IEEE/ICME International Conference on Complex Medical Engineering CME 2007, pp. 891-895, 23-27 May 2007], has been generalized in order to use this information to preprocess scans of other, nonbinary objects, e.g., to reduce artifacts in medical CT applications. Further on, the method was extended to handle scatter besides beam hardening and to allow for detector pixel-specific and ray-specific precorrections. This implies that the empirical binary tomography calibration (EBTC) technique is sensitive to spectral effects as they are induced by the heel effect, by shaped prefiltration, or by scanners with tube voltage modulation. The presented method models the beam hardening correction by using a rational function, while the scatter component is modeled using the pep model of B. Ohnesorge et al. [''Efficient object scatter correction algorithm for third and fourth generation CT scanners,'' Eur. Radiol. 9(3), 563-569 (1999)]. A smoothness constraint is applied to the parameter space to regularize the underdetermined system of nonlinear equations. The parameters determined are then used to precorrect CT scans. Results: EBTC was evaluated using simulated data of a flat panel cone-beam CT scanner with tube voltage modulation and bow-tie prefiltration and using real data of a flat panel cone-beam CT scanner. In simulation studies, where the ground truth is known, the authors' correction model proved to be highly accurate and was able to reduce beam hardening by 97% and scatter by about 75%. Reconstructions of measured data showed significantly less artifacts than the standard reconstruction. Conclusions: EBTC appears to be an efficient algorithm to precorrect CT raw data for beam hardening and scatter and it can account for ray-dependent spectral variations as they occur due to the heel effect, due to shaped prefiltration, or due to variations in tube voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual source model for Kilo-voltage cone beam CT: Source characteristics and model validation

Purpose: The purpose of this investigation was to study the source characteristics of a clinical kilo-voltage cone beam CT unit and to develop and validate a virtual source model that could be used for treatment planning purposes. Methods: We used a previously commissioned full Monte Carlo model and new bespoke software to study the source characteristics of a clinical kilo-voltage cone beam CT (CBCT) unit. We identified the main particle sources, their spatial, energy and angular distribution for all the image acquisition presets currently used in our clinical practice. This includes a combination of two energies (100 and 120 kVp), two filters (neutral and bowtie), and eight different x-ray beam apertures. We subsequently built a virtual source model which we validated against full Monte Carlo calculations. Results: We found that the radiation output of the clinical kilo-voltage cone beam CT unit investigated in this study could be reproduced with a virtual model comprising of two sources (target and filtration cone) or three sources (target, filtration cone and bowtie filter) when additional filtration was used. With this model, we accounted for more than 97% of the photons exiting the unit. Each source in our model was characterised by a origin distribution in both X and Y directions, a fluence map, a single energy spectrum for unfiltered beams and a two dimensional energy spectrum for bowtie filtered beams. The percentage dose difference between full Monte Carlo and virtual source model based dose distributions was well within the statistical uncertainty associated with the calculations ( {+-} 2%, one standard deviation) in all cases studied. Conclusions: The virtual source that we developed is accurate in calculating the dose delivered from a commercial kilo-voltage cone beam CT unit operating with routine clinical image acquisition settings. Our data have also shown that target, filtration cone, and bowtie filter sources needed to be all included in the model in order to accurately replicate the dose distribution from the clinical radiation beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances. Methods: A mobile light intraoperative accelerator (LIAC{sup Registered-Sign }, Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p-type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic{sup TM} EBT and EBT2) in PMMA and in a Solid Water{sup Registered-Sign} phantom. Several experimental set-ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set-ups and energies. Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon{sup Registered-Sign} and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any 'squircle-shaped' field. When one side of the rectangular field is held constant and the second side is reduced, both R{sub 50} and R{sub max} move towards the phantom surface. Comparing the PDDs obtained with the 5 cm circular applicator and with a 4.4 Multiplication-Sign 4.4 cm{sup 2} square field (that is the equivalent square of the 5 cm circular field) obtained with the beam shaper, a different behavior was observed in the region extending from the surface to a depth of 50% of the maximum dose. Isodoses measured for rectangular fields used for clinical cases (i.e., 4 Multiplication-Sign 9 cm{sup 2} 8 MeV) are shown, with different air gaps. For each energy investigated, the normalized OFs slowly increase, when the length of the side decreases down to about 4 cm, and then rapidly decreases for smaller field widths. MC simulation showed an excellent agreement with experimental data (<2%). Conclusions: The beam shaper device is able to provide square/rectangular/squircle fields with adequate dose homogeneity for mobile dedicated accelerators, thus allowing conformal treatment with IOERT. Monte Carlo simulation can be a very useful tool to simulate any clinical set up and can be used to create a data set to calculate MUs, thereby increasing the accuracy of the delivered dose during IOERT procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental analysis of general ion recombination in a liquid-filled ionization chamber in high-energy photon beams

Purpose: To study experimentally the general ion recombination effect in a liquid-filled ionization chamber (LIC) in high-energy photon beams. Methods: The general ion recombination effect on the response of a micro liquid ion chamber (microLion) was investigated with a 6 MV photon beam in normal and SRS modes produced from a Varian{sup Registered-Sign} Novalis Tx{sup TM} linear accelerator. Dose rates of the linear accelerator were set to 100, 400, and 1000 MU/min, which correspond to pulse repetition frequencies of 60, 240, and 600 Hz, respectively. Polarization voltages applied to the microLion were +800 and +400 V. The relative collection efficiency of the microLion response as a function of dose per pulse was experimentally measured with changing polarization voltage and pulse repetition frequencies and was compared with the theoretically calculated value. Results: For the 60 Hz pulse repetition frequency, the experimental relative collection efficiency was not different from the theoretical one for a pulsed beam more than 0.3% for both polarization voltages. For a pulsed radiation beam with a higher pulse repetition frequency, the experimental relative collection efficiency converged to the theoretically calculated efficiency for continuous beams. This result indicates that the response of the microLion tends toward the response to a continuous beam with increasing pulse repetition frequency of a pulsed beam because of low ion mobility in the liquid. Conclusions: This work suggests an empirical method to correct for differences in general ion recombination of a LIC between different radiation fields. More work is needed to quantitatively explain the LIC general ion recombination behavior in pulsed beams generated from linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality assurance of proton beams using a multilayer ionization chamber system

Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-121: Measuring Prompt Gamma Emission Profiles with a Multi-Stage Compton Camera During Proton Beam Irradiation: Initial Studies

Purpose: Recent studies have suggested that the characteristics of prompt gammas (PG) emitted during proton beam irradiation are advantageous for determining beam range during treatment delivery. The purpose of this work was to determine the feasibility of determining the proton beam range from PG data measured with a prototype Compton camera (CC) during proton beam irradiation. Methods: Using a prototype multi-stage CC the PG emission from a water phantom was measured during irradiation with clinical proton therapy beams. The measured PG emission data was used to reconstruct an image of the PG emission using a backprojection reconstruction algorithm. One dimensional (1D) profiles extracted from the PG images were compared to: 1) PG emission data measured at fixed depths using collimated high purity Germanium and Lanthanum Bromide detectors, and 2) the measured depth dose profiles of the proton beams. Results: Comparisons showed that the PG emission profiles reconstructed from CC measurements agreed very well with the measurements of PG emission as a function of depth made with the collimated detectors. The distal falloff of the measured PG profile was between 1 mm to 4 mm proximal to the distal edge of the Bragg peak for proton beam ranges from 4 cm to 16 cm in water. Doses of at least 5 Gy were needed for the CC to measure sufficient data to image the PG profile and localize the distal PG falloff. Conclusion: Initial tests of a prototype CC for imaging PG emission during proton beam irradiation indicated that measurement and reconstruction of the PG profile was possible. However, due to limitations of the operational parameters (energy range and count rate) of the current CC prototype, doses of greater than a typical treatment dose (∼2 Gy) were needed to measure adequate PG signal to reconstruct viable images. Funding support for this project provided by a grant from DoD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-586: Field Size Dependence of Output Factor for Uniform Scanning Proton Beams: A Comparison of TPS Calculation, Measurement and Monte Carlo Simulation

Purpose: Output dependence on field size for uniform scanning beams, and the accuracy of treatment planning system (TPS) calculation are not well studied. The purpose of this work is to investigate the dependence of output on field size for uniform scanning beams and compare it among TPS calculation, measurements and Monte Carlo simulations. Methods: Field size dependence was studied using various field sizes between 2.5 cm diameter to 10 cm diameter. The field size factor was studied for a number of proton range and modulation combinations based on output at the center of spread out Bragg peak normalized to a 10 cm diameter field. Three methods were used and compared in this study: 1) TPS calculation, 2) ionization chamber measurement, and 3) Monte Carlos simulation. The XiO TPS (Electa, St. Louis) was used to calculate the output factor using a pencil beam algorithm; a pinpoint ionization chamber was used for measurements; and the Fluka code was used for Monte Carlo simulations. Results: The field size factor varied with proton beam parameters, such as range, modulation, and calibration depth, and could decrease over 10% from a 10 cm to 3 cm diameter field for a large range proton beam. The XiO TPS predicted the field size factor relatively well at large field size, but could differ from measurements by 5% or more for small field and large range beams. Monte Carlo simulations predicted the field size factor within 1.5% of measurements. Conclusion: Output factor can vary largely with field size, and needs to be accounted for accurate proton beam delivery. This is especially important for small field beams such as in stereotactic proton therapy, where the field size dependence is large and TPS calculation is inaccurate. Measurements or Monte Carlo simulations are recommended for output determination for such cases.

07 ISOTOPE AND RADIATION SOURCES↗