Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Development of Instrumented Advanced Test Reactor Irradiation Capsule Experiment for In-situ Thermal Conductivity Measurements of High-Density Fuels

Idaho National Laboratory (INL) is developing a first-of-a-kind leadout instrumented capsule experiment design to enable in-situ measurement capabilities in the Advanced Test Reactor (ATR) core. The Ceramic Advanced Thermal Evolution Research (CRATER) experiment supports the aLEU program objective to accelerate fuel performance irradiation testing for identifying alternative high-assay, low enriched uranium (HALEU) fuel systems. CRATER is a fueled, instrumented capsule experiment to measure in-situ temperature and thermal conductivity of ceramic fuels. Two ceramic fuel types will be used, uranium mono-nitride (UN) and uranium mono-carbide (UC), with a third metallic fuel used for comparison (UMo). The three fuel specimens will use a stainless-steel cladding. Programmatic objectives include linear heat generation rates (LHGR) of 210 ± 25 Watts per cm. and an inner clad temperature of 300-450 °C. The evolution of fuel thermal conductivity during irradiation has never been successfully measured in-situ for these systems and this experiment is designed to use advances in measurement sciences to characterize how thermal transport properties evolve while in reactor. Neutronic simulations of the experiment and its surrounding reactor environment were conducted using the Monte Carlo N-Particle Transport code (MCNP) and result in optimized fuel enrichment to meet target linear heat generation rates (LHGRs) influencing fuel temperatures, and fuel burnup requirements. Fabrication research and development (R&D) efforts are underway to produce annular right cylinder UC and UN pellets using carbothermic reduction and nitridation (or hydride-dehydride-nitride) synthesis methods, followed double-action die cold isostatic pressing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerated aging test of new plastic scintillators

Fogging in plastic scintillators is a degradation mechanism that reduces light collection efficiency. In an effort to reduce maintenance costs, multiple groups have attempted to understand and prevent this problem by changing plastic compositions and system level designs. New formulations have been produced that are promising with respect to fogging resistance. In this paper, we study a variety of new compositions by subjecting them to an accelerated aging experiment with varying temperature and humidity profiles. Compositions are analyzed for their resistance to degradation after saturation periods, with those containing polymethyl methacrylate and divinyl benzene being the most promising. Pulse height spectra revealed that after environmental aging, many of the samples suffered a reduction in light yield to different degrees, a result that could be due to heating of the samples and may be prevented by further production optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Driven Neutron Source: A New Paradigm for Miniature Neutron Sources

Neutron interrogation techniques have specific advantages for detection of hidden, shielded, or buried threats over other detection modalities in that neutrons readily penetrate most materials providing backscattered gammas indicative of the elemental composition of the potential threat. Such techniques have broad application to military and homeland security needs. Present neutron sources and interrogation systems are expensive and relatively bulky, thereby making widespread use of this technique impractical. Development of a compact, high intensity crystal driven neutron source is described. The crystal driven neutron source approach has been previously demonstrated using pyroelectric crystals that generate extremely high voltages when thermal cycled. Placement of a sharpened needle on the positively polarized surface of the pyroelectric crystal results in sufficient field intensification to field ionize background deuterium molecules in a test chamber, and subsequently accelerate the ions to energies in excess of {approx}100 keV, sufficient for either D-D or D-T fusion reactions with appropriate target materials. Further increase in ion beam current can be achieved through optimization of crystal thermal ramping, ion source and crystal accelerator configuration. The advantage of such a system is the compact size along with elimination of large, high voltage power supplies. A novel implementation discussed incorporates an independently controlled ion source in order to provide pulsed neutron operation having microsecond pulse width.

07 ISOTOPE AND RADIATION SOURCES↗

Optics of the NIFS negative ion source test stand by infrared calorimetry and numerical modelling

At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H{sup −} production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron acceleration in solar flares

For the period Spetember 1978 to December 1982, 55 solar flare particle events for which the instruments on board the ISEE-3 spacecraft detected electrons above 10 MeV. Combining data with those from the ULEWAT spectrometer electron spectra in the range from 0.1 to 100 MeV were obtained. The observed spectral shapes can be divided into two classes. The spectra of the one class can be fit by a single power law in rigidity over the entire observed range. The spectra of the other class deviate from a power law, instead exhibiting a steepening at low rigidities and a flattening at high rigidities. Events with power-law spectra are associated with impulsive (less than 1 hr duration) soft X-ray emission, whereas events with hardening spectra are associated with long-duration (more than 1 hr) soft X-ray emission. The characteristics of long-duration events are consistent with diffusive shock acceleration taking place high in the corona. Electron spectra of short-duration flares are well reproduced by the distribution functions derived from a model assuming simultaneous second-order Fermi acceleration and Coulomb losses operating in closed flare loops.

Droge, Wolfgang↗

Uranus Orbiter and Probe: Mission Challenges and Concept Updates Since the Origins, Worlds, and Life Decadal Survey

Origins, Worlds, and Life: Planetary Science and Astrobiology in the Next Decade identified a Uranus Orbiter and Probe as the highest-priority strategic mission for the decade 2023–2032, as it enables broad cross-disciplinary science in the largely unexplored Uranian system. The mission architecture evaluated by the Decadal Survey was a singular proof of concept demonstrating that a moderately instrumented mission could deliver Decadal-priority science with a reduced cost and risk posture by leveraging existing technologies to the maximum extent possible. With revised assumptions since the Decadal, we have explored a large trade space including launch vehicles, propulsion options, cruise trajectories, available power sources, viable concept of operations, and science data return for later launch dates without a Jupiter gravity assist. The most repeatable trajectory solutions employ either a commercially derived solar electric propulsion (SEP) transfer stage or the availability of a more capable launch vehicle under development, such as the SpaceX Starship. Orbit insertion has been moved farther from Uranus to acknowledge the remaining uncertainty in Uranian ring structure. A streamlined, SEP-adaptable, orbiter design was developed using two Next Gen Radioisotope Thermoelectric Generators, and the probe design was matured, reducing the entry gravitational acceleration, and assuming the largest Decadal-recommended payload to provide margin for future instrument selections. With this updated design, we also constructed a detailed concept of operations for three representative science cases, returning 13–15 Gbit of science data and spacecraft telemetry per ∼34 day orbit.

Amy A Simon↗

A novel system for measurement of the transverse electron momentum distribution from photocathodes

The transverse momentum of electrons produced by a photocathode contributes significantly to the performance of several different types of accelerator-based light sources, such as Free Electron Lasers, as well as systems designed for ultrafast electron diffraction and dynamic transmission electron microscopy. Minimization of the transverse emittance from photocathodes is the subject of intensive research, and therefore measurement of this parameter is of great importance. Here, we describe a simple system that offers real time measurements of transverse emittance and can be easily integrated into the photocathode fabrication process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Control of liquid helium supply to cryopanels of Kolkata superconducting cyclotron

The Kolkata superconducting cyclotron utilises liquid helium to cool the main magnet niobium-titanium (NbTi) coil and the cryopanels. Three liquid helium cooled cryopanels, placed inside the dees of the radio-frequency system, maintain the high vacuum in the acceleration region of the superconducting cyclotron. The small cryostat placed inside the cryogenic distribution manifold located at the basement of the superconducting cyclotron building supplies liquid helium in parallel branches to three cold heads, used for cooling their associated cryopanels. The level in the cryostat has to be maintained at an optimum value to ensure uninterrupted flow of liquid helium to these three cold heads. This paper describes the transfer function of the overall system, its tuning parameters, and discusses the actual control of cryostat level by using these parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geophysical measurements of a demolition at NRF

On May 31 st , 2025, at approximately 14:40:00 UTC, the former Submarine First Westinghouse (SW1) structure housing a large crane was demolished at the Naval Reactors Facility (NRF) located within the perimeter of the Idaho National Laboratory (INL). Several targeted explosives were used to facilitate this demolition. The INL Seismic Monitoring Program (SMP) installed four temporary seismic instrument suites around the site of the demolition in order to monitor ground motion including measuring peak ground acceleration (PGA), peak ground velocity (PGV), and to calculate peak ground displacement (PGD). The demolition produced three types of waves: body waves, surface waves, and acoustic waves. The acoustic wave represents the largest signal received. The PGA, measured on the eastern component of the instrument located approximately 95m away from the demolition site, was 0.187g. The PGV measured was 0.0004 m/s, and the PGD was approximately 0.000006m. Rayleigh waves incident on an instrument located at the Advanced Test Reactor, about 7.6km away, were used to estimate a magnitude of 0.3 at the ATR, representing a yield of energy equivalent to approximately 3 grams of TNT.

58 - GEOSCIENCES↗

Evaluation of a digital data acquisition system and optimization of n-{gamma} discrimination for a compact neutron spectrometer

A compact NE213 liquid scintillation neutron spectrometer with a new digital data acquisition (DAQ) system is now in operation at the Physikalisch-Technische Bundesanstalt (PTB). With the DAQ system, developed by ENEA Frascati, neutron spectrometry with high count rates in the order of 5x10{sup 5} s{sup -1} is possible, roughly an order of magnitude higher than with an analog acquisition system. To validate the DAQ system, a new data analysis code was developed and tests were done using measurements with 14-MeV neutrons made at the PTB accelerator. Additional analysis was carried out to optimize the two-gate method used for neutron and gamma (n-{gamma}) discrimination. The best results were obtained with gates of 35 ns and 80 ns. This indicates that the fast and medium decay time components of the NE213 light emission are the ones that are relevant for n-{gamma} discrimination with the digital acquisition system. This differs from what is normally implemented in the analog pulse shape discrimination modules, namely, the fast and long decay emissions of the scintillating light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification to the accelerator of the NBI-1B ion source for improving the injection efficiency

Minimizing power loss of a neutral beam imposes modification of the accelerator of the ion source for further improvement of the beam optics. The beam optics can be improved by focusing beamlets. The injection efficiencies by the steering of ion beamlets are investigated numerically to find the optimum modification of the accelerator design of the NBI-1B ion source. The beam power loss was reduced by aperture displacement of three edge beamlets arrays considering power loadings on the beamline components. Successful testing and operation of the ion source at 60 keV/84% of injection efficiency led to the possibility of enhancing the system capability to a 2.4 MW power level at 100 keV/1.9 μP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurement of the matched spot size in a slow capillary discharge optical waveguide

This communication presents direct method for experimental determining the matched spot size in a plasma optical waveguide, created in a slow capillary discharge. It can be used for Laser Wakefield Acceleration experiments in addition to interferometry for fast control of optical properties of discharge plasma. The measurements are done by means of the comparison of the laser beam size at the entrance and at the exit of the plasma channel. They are direct in the sense that the interpretation is made in terms of the refractive index without usage of the information about electron density distribution. The method can be used for matched spot size measurement in conditions of the nonlinear effects (transmission of high power laser pulses)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of gridded energy analyzer and laser induced fluorescence measurements of a two-component ion distribution

We present ion velocity distribution function (IVDF) measurements obtained with a five grid retarding field energy analyzer (RFEA) and IVDF measurements obtained with laser induced fluorescence (LIF) for an expanding helicon plasma. The ion population consists of a background population and an energetic ion beam. When the RFEA measurements are corrected for acceleration due to the electric potential difference across the plasma sheath, we find that the RFEA measurements indicate a smaller background to beam density ratio and a much larger parallel ion temperature than the LIF. The energy of the ion beam is the same in both measurements. These results suggest that ion heating occurs during the transit of the background ions through the sheath and that LIF cannot detect the fraction of the ion beam whose metastable population has been eliminated by collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of barium ion jets in the magnetosphere using Doppler imaging systems and very sensitive imaging systems using imaging photon detectors

Observations of four shaped charge releases from rockets launched from Alaska are described. Results demonstrate that imaging and Doppler imaging instruments, based on exploiting the imaging photon detector, provide additional insight into the motion and development of low intensity targets such as the fast ion jets produced by shaped charge releases. It is possible to trace the motion of fast ion jets to very great distances, of the order of 50,000 km, outward along the Earth's magnetic field, when the conditions are suitable for the outward (upward) motion and/or acceleration of such ion jets. It is shown that ion jets, which fade below the lower sensitivity threshold of previous instruments, do not always disappear. There is no evidence of an abrupt field-aligned shear-type acceleration.

Rees, D.↗

A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of 1 × 10{sup −15}

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of 1 × 10{sup −15} at integration times between 1 and 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission Space-Time Explorer and QUantum Equivalence Principle Space Test (STE-QUEST) ( http://sci.esa.int/ste-quest/ ). It was therefore designed to be compact, to sustain accelerations occurring during rocket launch, to exhibit low vibration sensitivity, and to reach a low frequency instability. Overall dimensions of the optical system are 40 cm × 20 cm × 30 cm. The acceleration sensitivities of the optical frequency in the three directions were measured to be 1.7 × 10{sup −11}/g, 8.0 × 10{sup −11}/g, and 3.9 × 10{sup −10}/g, and the absolute frequency instability was determined via a three-cornered hat measurement. Two additional cavity-stabilized lasers were used for this purpose, one of which had an instability σ{sub y} < 4 × 10{sup −16} at 1 s integration time. The design is also appropriate and useful for terrestrial applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam simulation studies of ECR beam extraction and low energy beam transport for FRIB

To meet the beam power requirements of 400 kW at the fragmentation target for facility for Rare Isotope Beams (FRIB), simultaneous acceleration of two-charge states should be used for heavier ions. These intense multi-charged ion beams will be produced by a 28 GHz electron cyclotron resonance (ECR) ion source at a high voltage of 35 kV. After extraction, the ion beam will be pre-accelerated to 12 keV/u with a 50 kV platform, transported down to an achromatic charge state selection (CSS) system followed by a vertical transport line, and then injected into a radio frequency quadrupole accelerator. The TRACK code developed at ANL is used to perform the simulations of the ECR beam extraction and low energy beam transport for FRIB. In this study, we include the magnetic field of ECR ion source into simulations. Different initial beam conditions as well as different space charge neutralization levels are tested for the ECR beamline. The beam loss in CSS system and the corresponding protective measures are discussed. The detailed results about the beam dynamic simulation and beam loss in CSS system will be presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems

Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99 Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of a cascaded longitudinal space charge amplifier for coherent radiation generation

Longitudinal space charge (LSC) effects are generally considered as harmful in free-electron lasers as they can seed unfavorable energy modulations that can result in density modulations with associated emittance dilution. It was pointed out, however, that such \micro-bunching instabilities" could be potentially useful to support the generation of broadband coherent radiation. Therefore there has been an increasing interest in devising accelerator beam lines capable of controlling LSC induced density modulations. In the present paper we augment these previous investigations by combining a grid-less space charge algorithm with the popular particle-tracking program elegant. This high-fidelity model of the space charge is used to benchmark conventional LSC models. We then employ the developed model to optimize the performance of a cascaded longitudinal space charge amplifier using beam parameters comparable to the ones achievable at Fermilab Accelerator Science & Technology (FAST) facility currently under commissioning at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗