Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Endovascular Mechanical Recanalisation After Intravenous Thrombolysis in Acute Anterior Circulation Stroke: The Impact of a New Temporary Stent

Purpose: Treatment of acute stroke by endovascular mechanical recanalisation (EMR) has shown promising results and continues to be further refined. We evaluated the impact of a temporary stent compared with our results using other mechanical devices. Materials and Methods: We analysed clinical and radiological data of all patients who were treated by EMR after intravenous thrombolysis for acute carotid T- and middle-cerebral artery (M1) occlusions at our centre between 2007 and 2011. A comparison was performed between those patients in whom solely the stent-retriever was applied (group S) and those treated with other devices (group C). Results: We identified 14 patients for group S and 16 patients for group C. Mean age, National Institute of Health Stroke Scale score, and time to treatment were 67.1 years and 16.5 and 4.0 h for group S and 61.1 years and 17.6 and 4.5 h for group C, respectively. Successful recanalisation (thrombolysis in cerebral infarction scores {>=}IIb) was achieved in 93% of patients in group S and 56% of patients in group C (P < 0.05). Mean recanalisation times for M1 occlusions were 23 min (group S) and 29 min (group C) and for carotid-T occlusions were 39 min (group S) and 50 min (group C), and 45% of the patients in group S and 33% in group C had a favourable outcome (Modified Rankin Scale score {<=}2). Conclusion: The findings suggest an improvement in recanalisation success by the application of a temporary stent compared with previously used devices. These results are to be confirmed by larger studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Infrapopliteal Drug-Eluting Stents

IntroductionThere are no cost-utility data about below-the-knee placement of drug-eluting stents. The authors determined the cost-effectiveness of infrapopliteal drug-eluting stents for critical limb ischemia (CLI) treatment. The event-free individual survival outcomes defined by the absence of any major events, including death, major amputation, and target limb repeat procedures, were reconstructed on the basis of two published infrapopliteal series. The first included spot Bail-out use of Sirolimus-eluting stents versus bare metal stents after suboptimal balloon angioplasty (Bail-out SES).The second was full-lesion Primary Everolimus-eluting stenting versus plain balloon angioplasty and bail-out bare metal stenting as necessary (primary EES). The number-needed-to-treat (NNT) to avoid one major event and incremental cost-effectiveness ratios (ICERs) were calculated for a 3-year postprocedural period for both strategies. Overall event-free survival was significantly improved in both strategies (hazard ratio (HR) [confidence interval (CI)]: 0.68 [0.41-1.12] in Bail-out SES and HR [CI]: 0.53 [0.29-0.99] in Primary EES). Event-free survival gain per patient was 0.89 (range, 0.11-3.0) years in Bail-out SES with an NNT of 4.6 (CI: 2.5-25.6) and a corresponding ICER of 6,518 Euro-Sign (range 1,685-10,112 Euro-Sign ). Survival gain was 0.91 (range 0.25-3.0) years in Primary EES with an NNT of 2.7 (CI: 1.7-5.8) and an ICER of 11,581 Euro-Sign (range, 4,945-21,428 Euro-Sign ) per event-free life-year gained. Two-way sensitivity analysis showed that stented lesion length >10 cm and/or DES list price >1000 Euro-Sign were associated with the least economically favorable scenario in both strategies. Both strategies of bail-out SES and primary EES placement in the infrapopliteal arteries for CLI treatment exhibit single-digit NNT and relatively low corresponding ICERs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Infrarenal Aortic Stenting With or Without Iliac Stenting for Isolated and Aortoiliac Stenoses: Single-Centre Experience With Long-Term Follow-Up

The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 {+-} 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan-Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non-flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60-132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 {+-} -0.15 (right) and 0.61 {+-} -0.16 (left). After the procedure they were 0.86 {+-} -0.07 (right) and 0.90 {+-} -0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic stenotic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radioembolization as Locoregional Therapy of Hepatic Metastases in Uveal Melanoma Patients

To retrospectively evaluate the overall survival, safety, and efficacy of metastatic uveal melanoma patients after radioembolization as salvage therapy. Thirteen patients were treated with radioembolization of branches of the hepatic artery with resin-based yttrium-90 ({sup 90}Y)-labelled microspheres. Twelve patients underwent a single application, and 1 patient underwent 4 interventions. Dosages from 644 to 2,450 MBq (mean activity 1,780) were applied. Treatment response was evaluated by way of liver magnetic resonance imaging and computed tomography (CT) as well as whole-body fluorodeoxyglucose positron emission tomography (PET)/CT with evaluation of percentage changes in SUV{sub max} before and at 2-3 months after therapy. Kaplan-Meier analysis was calculated to determine overall survival. Partial remission (PR) was observed in 8 (62 %), stable disease (SD) in 2 (15 %), and progressive disease (PD) in 3 (23 %) patients under terms of standard criteria and PR in 3 (23 %), SD in 3 (23 %), and PD in 7 (54 %) patients according to PET criteria. Neither RECIST nor PET criteria showed a significant difference in predicting overall survival (P = 0.12 and 0.11, respectively). Median survival time after radioembolization was 7 months. No acute toxicity with in-hospital morbidity was observed. One patient developed hepatomegaly, and 1 patient developed gastric ulceration. Throughout follow-up, progression of extrahepatic metastases was observed. Radioembolization may be a promising therapy in uveal melanoma patients with predominant hepatic metastases. At first follow-up, we observed PR or SD in 77 % patients under terms of standard criteria with an acceptable toxicity profile.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unexpected Complication with the New C3 Excluder: Cause and Treatment

The new C3 Gore Excluder delivery system enables both up/downward and rotational repositioning of the device before complete deployment. This contributes to more precise proximal landing and permits facilitation of the contralateral gate cannulation. During separate deployment, the position of the ipsilateral limb can also be readjusted. We have used the modified C3 delivery system in more than 50 patients, and in most cases, we were able to utilize the repositioning options of the device to achieve optimal fixation and sealing. However, we present a case where our attempt to readjust the position of the ipsilateral limb led to upward migration of the main body with coverage of the left renal artery origin. The latter was secured with a bare stent implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Reliability and Quality of Online Uterine Fibroid Embolization Resources

This study was designed to examine the best internet resources about uterine fibroid embolization (UFE) pertinent to medical trainees, radiologists, gynecologists, family physicians, and patients. The terms 'uterine fibroid embolization,' 'uterine fibroid embolization,' and 'uterine artery embolization' were entered into Google, Yahoo, and Bing search engines; the top 20 hits were assessed. The hits were categorized as organizational or nonorganizational. Additionally, 23 radiological and obstetrical organizations were assessed. The DISCERN instrument and Journal of the American Medical Association (JAMA) benchmarks (authorship, attribution, currency, disclosure) were used to assess the information critically. The scope, strength, weaknesses, and unique features were highlighted for the top five organizational and nonorganizational websites. A total of 203 websites were reviewed; 23 were removed in accordance with the exclusion criteria and 146 were duplicate websites, for a total of 34 unique sites. It was found that 35 % (12/34 websites) were organizational (family medicine, radiology, obstetrics/gynecology) and 65 % (22/34 websites) were nonorganizational (teaching or patient resources). The overall mean DISCERN score was 49.6 (10.7). Two-tailed, unpaired t test demonstrated no statistically significant difference between organizational and nonorganizational websites (p = 0.101). JAMA benchmarks revealed 44 % (15/34 websites) with authorship, 71 % (24/34 websites) with attribution, 68 % (23/34 websites) with disclosure, and 47 % (16/34 websites) with currency. The overall quality of websites for UFE is moderate, with important but not serious shortcomings. The best websites provided relevant information about the procedure, benefits/risks, and were interactive. DISCERN scores were compromised by sites failing to provide resources for shared decision-making, additional support, and discussing consequence of no treatment. JAMA benchmarks revealed lack of authorship and currency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvement of Stent Retriever Design and Efficacy of Mechanical Thrombectomy in a Flow Model

In vitro experiments were performed to evaluate the efficacy of mechanical intracranial thrombectomy comparing the newly developed Aperio stent retriever and standard devices for stroke treatment. The Aperio (A), with an increased working length of 4 cm and a special cell design for capturing and withholding clots, was compared to three benchmark devices: the Solitaire retrievable stent (B), the Merci X6 (C), and the Merci L5 retriever (D). In a vascular glass model with pulsatile flow, reminiscent of the M1 segment of the middle cerebral artery, we repeatedly induced occlusion by generating thrombi via a modified Chandler loop system. The numbers of recanalization attempts, peripheral embolizations, and recanalizations at the site of occlusion were recorded during 10 retrieval experiments with each device. Eleven devices were able to remove the blood clots from the occluded branch. In 34 of 40 experiments, restoration of flow was obtained in 1-3 attempts. The main differences between the study devices were observed in terms of clot withholding and fragmentation during retrieval. Although there was only one fragmentation recorded for device A, disengagement of the whole clot or peripheral embolization of fragments occurred more frequently (5-7 times) with devices B, C, and D. In a vascular model, the design of device A was best at capturing and withholding thrombi during retrieval. Further study will be necessary to see whether this holds true in clinical applications.

42 ENGINEERING↗

Transseptal Guidewire Stabilization for Device Closure of a Large Pulmonary Arteriovenous Malformation

A 46-year-old man presenting with massive hemoptysis was found to have a large pulmonary arteriovenous malformation (PAVM) in the right lung. Closure of the PAVM with an Amplatzer-type duct occluder was hampered by inability to advance the device delivery sheath into the PAVM due to vessel tortuosity and inadequate guidewire support. Atrial septal puncture was performed and a femorofemoral arteriovenous guidewire loop through the right pulmonary artery, PAVM, and left atrium was created. Traction on both ends of the guidewire loop allowed advancement of the device delivery sheath into the PAVM and successful completion of the procedure. Transseptal guidewire stabilization can be a valuable option during device closure of large PAVMs when advancement, stability, or kinking of the device delivery sheath is an issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Active Splenic Bleeding After Colonoscopy: A Systematic Review of the Literature

Purpose: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. Methods: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reported case of PSAE) was performed and the three types of treatment compared. Results: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8 %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74 %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44 %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. Conclusion: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic ruptures after colonoscopy in hemodynamically stabilized patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two Cases of Postmyomectomy Pseudoaneurysm Treated by Transarterial Embolization

Pseudoaneurysm resulting from hysteroscopic myomectomy is a rare clinical situation, and interventional radiologists are not traditionally involved in the management. To our knowledge, endovascular treatment of a pseudoaneurysm resulting from hysteroscopic myomectomy has not yet been reported in the English-language literature. Here, two such cases are reported, including one of a woman who later became pregnant. The case is unique because little is known about the influence of unilateral coil embolization of the uterine artery on fertility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Embolization of Type II Endoleaks after EVAR: The Role of Ethylene Vinyl Alcohol Copolymer (Onyx)

Purpose: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx). Methods: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37-83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinical success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. Result: Mean follow-up time was 26.0 (range 6-50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels. Conclusion: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

Introduction: A root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data to determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Endovascular Recanalization of Splenic Vein in Patients with Regional Portal Hypertension Complicated by Gastrointestinal Bleeding

Purpose: Regional portal hypertension (RPH) is an uncommon clinical syndrome resulting from splenic vein stenosis/occlusion, which may cause gastrointestinal (GI) bleeding from the esophagogastric varices. The present study evaluated the safety and efficacy of transjugular endovascular recanalization of splenic vein in patients with GI bleeding secondary to RPH. Methods: From December 2008 to May 2011, 11 patients who were diagnosed with RPH complicated by GI bleeding and had undergone transjugular endovascular recanalization of splenic vein were reviewed retrospectively. Contrast-enhanced computed tomography revealed splenic vein stenosis in six cases and splenic vein occlusion in five. Etiology of RPH was chronic pancreatitis (n = 7), acute pancreatitis with pancreatic pseudocyst (n = 2), pancreatic injury (n = 1), and isolated pancreatic tuberculosis (n = 1). Results: Technical success was achieved in 8 of 11 patients via the transjugular approach, including six patients with splenic vein stenosis and two patients with splenic vein occlusion. Two patients underwent splenic vein venoplasty only, whereas four patients underwent bare stents deployment and two covered stents. Splenic vein pressure gradient (SPG) was reduced from 21.5 ± 7.3 to 2.9 ± 1.4 mmHg after the procedure (P < 0.01). For the remaining three patients who had technical failures, splenic artery embolization and subsequent splenectomy was performed. During a median follow-up time of 17.5 (range, 3–34) months, no recurrence of GI bleeding was observed. Conclusions: Transjugular endovascular recanalization of splenic vein is a safe and effective therapeutic option in patients with RPH complicated by GI bleeding and is not associated with an increased risk of procedure-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Graft Patency in Long-term Survivors after Renovisceral Debranching with VORTEC

PurposeThis study was designed to evaluate retrospectively the long-term stent-graft patency after renovisceral revascularization with Viabahn Open Revascularization Technique (VORTEC) using computed tomography angiography (CTA) and magnetic resonance angiography (MRA).MethodsIn 34 patients (seven women; mean age 72 ± 8 years) with aortic aneurysm, 63 renovisceral vessels (i.e., 54 renal, nine visceral arteries) were revascularized with VORTEC between 2004 and 2009. All patients obtained a pre- and postinterventional CTA and at least one follow-up CTA or MRA after 6 or more months following intervention (median follow up: 43 months). Detection of bypass occlusion, bypass stenosis, infolding, stent-graft fractures and dislocations, and kidney shrinkage were noted by two readers in consensus. Furthermore, mortality during follow-up was assessed using the medical report.ResultsDuring follow-up, 12.6 % of stent-grafts occluded. Cumulative patency rate was 95.2 ± 2.7 % at 12 months, 87.7 ± 4.4 % at 24 and 36 months, and 84.7 ± 5.2 % at 48, 60, 72, 84, and 89 months, respectively. Overall, 19 % of stent-grafts (12/63) developed bypass stenosis (<50 %, 10 stent-grafts; > 50 %, 2 stent-grafts), in one case stenosis (>70 %) was suspected to be hemodynamically significant. No secondary dislocation, no infolding of renovisceral stent-grafts, and no stent-graft fracture occurred. Kidney shrinkage occurred in nine patients, primarily in patients with an occluded Viabahn (n = 7). Eleven patients (32.3 %) died within the follow-up time period.ConclusionsIn long-term survivors after VORTEC cumulative patency rate remained high, and no stent-graft fractures or secondary dislocations occurred.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Retrieval of Foreign Bodies Around Vital Vessels Aided with Vascular Intervention: A Technical Note

ObjectiveTo describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.MethodsUnder fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB. Prior to removal of the FB, the position of the nearest vessel was identified using a guide wire or catheter placed into the vessel. Balloon catheter was also simultaneously used to temporarily stop the blood flow of the nearest artery during the FB removal in three of the nine patients.ResultsAll of the nine FBs with 0–2 mm interval to the nearest vessel were successfully removed in the nine patients without any serious complications. The removed FBs measured 3–12 mm in length and 1–3 mm in width. The total fluoroscopic time of retrieval of each FB was 5–9 min (mean, 6.4 min). The volume of intraoperative bleeding ranged from 5 to 12 ml (mean, 7.5 ml). The length of hospital stay for each patient ranged from 4 to 8 days (mean, 5.5 days).ConclusionVascular intervention-aided percutaneous FB removal is minimally invasive and an effective method for removal of FBs around vital vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗