Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

A novel method for experimental characterization of large-angle scattered particles in scanned carbon-ion therapy

Purpose: It is essential to consider large-angle scattered particles in dose calculation models for therapeutic carbon-ion beams. However, it is difficult to measure the small dose contribution from large-angle scattered particles. In this paper, the authors present a novel method to derive the parameters describing large-angle scattered particles from the measured results. Methods: The authors developed a new parallel-plate ionization chamber consisting of concentric electrodes. Since the sensitive volume of each channel is increased linearly with this type, it is possible to efficiently and easily detect small contributions from the large-angle scattered particles. The parameters describing the large-angle scattered particles were derived from pencil beam dose distribution in water measured with the new ionization chamber. To evaluate the validity of this method, the correction for the field-size dependence of the doses, “predicted-dose scaling factor,” was calculated with the new parameters. Results: The predicted-dose scaling factor calculated with the new parameters was compared with the existing one. The difference between the new correction factor and the existing one was 1.3%. For target volumes of different sizes, the calculated dose distribution with the new parameters was in good agreement with the measured one. Conclusions: Parameters describing the large-angle scattered particles can be efficiently and rapidly determined using the new ionization chamber. The authors confirmed that the field-size dependence of the doses could be compensated for by the new parameters. This method makes it possible to easily derive the parameters describing the large-angle scattered particles, while maintaining the dose calculation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculation of Dose Deposition in 3D Voxels by Heavy Ions and Simulation of gamma-H2AX Experiments

The biological response to high-LET radiation is different from low-LET radiation due to several factors, notably difference in energy deposition and formation of radiolytic species. Of particular importance in radiobiology is the formation of double-strand breaks (DSB), which can be detected by -H2AX foci experiments. These experiments has revealed important differences in the spatial distribution of DSB induced by low- and high-LET radiations [1,2]. To simulate -H2AX experiments, models based on amorphous track with radial dose are often combined with random walk chromosome models [3,4]. In this work, a new approach using the Monte-Carlo track structure code RITRACKS [5] and chromosome models have been used to simulate DSB formation. At first, RITRACKS have been used to simulate the irradiation of a cubic volume of 5 m by 1) 450 1H+ ions of 300 MeV (LET 0.3 keV/ m) and 2) by 1 56Fe26+ ion of 1 GeV/amu (LET 150 keV/ m). All energy deposition events are recorded to calculate dose in voxels of 20 m. The dose voxels are distributed randomly and scattered uniformly within the volume irradiated by low-LET radiation. Many differences are found in the spatial distribution of dose voxels for the 56Fe26+ ion. The track structure can be distinguished, and voxels with very high dose are found in the region corresponding to the track "core". These high-dose voxels are not found in the low-LET irradiation simulation and indicate clustered energy deposition, which may be responsible for complex DSB. In the second step, assuming that DSB will be found only in voxels where energy is deposited by the radiation, the intersection points between voxels with dose > 0 and simulated chromosomes were obtained. The spatial distribution of the intersection points is similar to -H2AX foci experiments. These preliminary results suggest that combining stochastic track structure and chromosome models could be a good approach to understand radiation-induced DSB and chromosome aberrations.

Plante, I.↗

Representative elementary volume estimation for porosity, moisture saturation, and air-water interfacial areas in unsaturated porous media: Data quality implications

Achieving a representative elementary volume (REV) has become a de facto criterion for demonstrating the quality of {mu}CT measurements in porous media systems. However, the data quality implications of an REV requirement have not been previously examined. In this work, deterministic REVs for porosity, moisture saturation (S{sub W}), and air-water interfacial area (A{sub I}) were estimated using a set of 49 {mu}CT images of eight unsaturated homogeneous porous media with heterogeneity in moisture distributions present in varying degrees. Estimated porosity REVs were <8 mm{sup 3} for all cases, smaller than typical CT image sizes ({approx}100 mm{sup 3}). Estimated S{sub W} and A{sub I} REVs were <55 mm{sup 3} for cases with homogeneous moisture distributions but could not be estimated for cases with heterogeneous moisture distributions, due to the absence of a distinct 'REV plateau' within the maximum imaged volume. Conventionally, S{sub W} and A{sub I} data from such non-REV cases would be excluded. The implications of excluding data on the basis of REV were examined by comparing A{sub I}-S{sub W} data measured on image windows of increasing size against the expected linear A{sub I}-S{sub W} relationship. At measurement scales exceeding porosity REV, random fluctuations in A{sub I}-S{sub W} data were excluded, even for cases containing heterogeneous moisture distributions. In contrast, requiring measurement scales to exceed S{sub W} and A{sub I} REV appeared overly restrictive and resulted in visible loss of reliable A{sub I}-S{sub W} data. We attribute these findings to overestimation of REVs due to inherently problematic estimation of deterministic REVs in real systems. Implications of these findings for ensuring CT data quality and the efficient use of CT data are discussed.

99 GENERAL AND MISCELLANEOUS↗

Fluorescence imaging of lattice re-distribution on step-index direct laser written Nd:YAG waveguide lasers

The laser performance and crystalline micro-structural properties of near-infrared step-index channel waveguides fabricated inside Neodymium doped YAG laser ceramics by means of three-dimensional sub-picosecond pulse laser direct writing are reported. Fluorescence micro-mapping of the waveguide cross-sections reveals that an essential crystal lattice re-distribution has been induced after short pulse irradiation. Such lattice re-distribution is evidenced at the waveguide core corresponding to the laser written refractive index increased volume. The waveguides core surroundings also present diverse changes including slight lattice disorder and bi-axial strain fields. The step-index waveguide laser performance is compared with previous laser fabricated waveguides with a stress-optic guiding mechanism in absence of laser induced lattice re-distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A CHANDRA X-RAY SURVEY OF EJECTA IN THE CASSIOPEIA A SUPERNOVA REMNANT

We present a survey of the X-ray-emitting ejecta in the Cassiopeia A supernova remnant (SNR) based on an extensive analysis of over 6000 spectral regions extracted on 2.''5-10'' angular scales using the Chandra 1 Ms observation. We interpret these results in the context of hydrodynamical models for the evolution of the remnant. The distributions of fitted temperature and ionization age, and the implied mass coordinates, are highly peaked and suggest that the ejecta were subjected to multiple secondary shocks following reverse shock interaction with ejecta inhomogeneities. Based on the fitted emission measure and element abundances, and an estimate of the emitting volume, we derive masses for the X-ray-emitting ejecta and also show the distribution of the mass of various elements over the remnant. An upper limit to the total shocked Fe mass visible in X-rays appears to be roughly 0.13 M{sub Sun }, which accounts for nearly all of the mass expected in Fe ejecta. We find two populations of Fe ejecta, that associated with normal Si burning and that possibly associated with {alpha}-rich freezeout, with a mass ratio of approximately 2:1. Essentially all of the observed Fe (both components) lies well outside the central regions of the SNR, possibly having been ejected by hydrodynamic instabilities during the explosion. We discuss this and its implications for the neutron star kick.

79 ASTRONOMY AND ASTROPHYSICS↗

Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field

Purpose: There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities in this field by proposing and examining by Monte Carlo simulations, a probable longitudinal configuration where the magnetic field is oriented in the same direction as the photon beam. Methods: The EGSnrc Monte Carlo (MC) radiation transport codes with algorithms implemented to account for the magnetic field deflection of charged particles were used to compare dose distributions for linac-MR systems in transverse and longitudinal geometries. Specifically, the responses to a 6 MV pencil photon beam incident on water and lung slabs were investigated for 1.5 and 3.0 T magnetic fields. Further a five field lung plan was simulated in the longitudinal and transverse geometries across a range of magnetic field strengths from 0.2 through 3.0 T. Results: In a longitudinal geometry, the magnetic field is shown to restrict the radial spread of secondary electrons to a small degree in water, but significantly in low density tissues such as lung in contrast to the lateral shift in dose distribution seen in the transverse geometry. These effects extend to the patient case, where the longitudinal configuration demonstrated dose distributions more tightly confined to the primary photon fields, which increased dose to the planning target volume (PTV), bettered dose homogeneity within a heterogeneous (in density) PTV, and reduced the tissue interface effects associated with the transverse geometry. Conclusions: Dosimetry issues observed in a transverse linac-MR geometry such as changes to the depth dose distribution and tissue interface effects were significantly reduced or eliminated in a longitudinal geometry on a representative lung plan. Further, an increase in dose to the PTV, resulting from the magnetic field confining electrons to the forward direction, shows potential for a reduction in dose to the surrounding tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-92: On-Line Cone Beam CT Based Planning for Emergency and Palliative Radiation Therapy

Purpose: To evaluate and develop the feasibility of on-line cone beam CT based planning for emergency and palliative radiotherapy treatments. Methods: Subsequent to phantom studies, a case library of 28 clinical megavoltage cone beam CT (MVCBCT) was built to assess dose-planning accuracies on MVCBCT for all anatomical sites. A simple emergency treatment plan was created on the MVCBCT and copied to its reference CT. The agreement between the dose distributions of each image pair was evaluated by the mean dose difference of the dose volume and the gamma index of the central 2D axial plane. An array of popular urgent and palliative cases was also evaluated for imaging component clearance and field-of-view. Results: The treatment cases were categorized into four groups (head and neck, thorax/spine, pelvis and extremities). Dose distributions for head and neck treatments were predicted accurately in all cases with a gamma index of >95% for 2% and 2 mm criteria. Thoracic spine treatments had a gamma index as low as 60% indicating a need for better uniformity correction and tissue density calibration. Small anatomy changes between CT and MVCBCT could contribute to local errors. Pelvis and sacral spine treatment cases had a gamma index between 90% and 98% for 3%/3 mm criteria. The limited FOV became an issue for large pelvis patients. Imaging clearance was difficult for cases where the tumor was positioned far off midline. Conclusion: The MVCBCT based dose planning and delivery approach is feasible in many treatment cases. Dose distributions for head and neck patients are unrestrictedly predictable. Some FOV restrictions apply to other treatment sites. Lung tissue is most challenging for accurate dose calculations given the current imaging filters and corrections. Additional clinical cases for extremities need to be included in the study to assess the full range of site-specific planning accuracies. This work is supported by Siemens.

60 APPLIED LIFE SCIENCES↗

Quantitative Highlights of 20 years Aqua Data Archive and Data Usage

NASA’s Aqua satellite carries six Earth-observing instruments Atmospheric Infrared Sounder (AIRS), Advanced Microwave Scanning Radiometer for EOS (AMSR-E), Advanced Microwave Sounding Unit (AMSU), Clouds and the Earth’s Radiant Energy System (CERES), Humidity Sounder for Brazil (HSB) and Moderate Resolution Imaging Spectroradiometer (MODIS). Currently only four of six instruments are collecting data, two instruments that stopped transmitting data are AMSR-E that suffered a major anomaly in October 2011 and was powered off in March 2016 while as HSB failed in February 2003. NASA’s Earth Science Data and Information System (ESDIS) Project makes these data, along with derived products, available to worldwide data users. Since the launch of Aqua on May 4, 2002, more than 10,000 data products have been archived and distributed by NASA-funded Distributed Active Archive Centers (DAACs) that are part of NASA’s Earth Observing System Data and Information System (EOSDIS). At the end of the 2021 Fiscal Year with over 100,000 orbits data, about 1,000 Aqua data products constituted almost 16.5 % of the entire EOSDIS data archive volume (8.6 PB out of approximately 55.2 PB), and 7.5 PB of Aqua data were distributed to over half-a-million public users worldwide. By categorizing the Aqua data products and their distribution, we can get a quantitative assessment of Aqua data usage. NASA’s ESDIS Project has collected archive, distribution, and user information from EOSDIS data users since February 2000. These metrics are available through the ESDIS Metrics System (EMS). EMS information is stored in a relational database from which quantitative metrics of Aqua data use can be retrieved and analyzed. The purposes of this study are to: 1) perform a comprehensive investigation of the 20-year trend in the archive and distribution of Aqua data products; 2) identify and characterize data product usage over the last 20 years; and 3) identify and characterize the global user community for these data. In addition to revealing how Aqua data use has evolved over time, the results of this study provide insights on identifying the various user communities for different kinds of Earth science data products. Also, because of the enormous quantity of data handled by EOSDIS DAACs, the study provides guidance of the requirements for future data systems that will be needed to effectively and efficiently handle the ever-increasing amounts of Earth science data produced by future (and ongoing) Earth science missions.

Lalit Wanchoo↗

Local Measurement in Annular Flows Using a Two-Sensor Droplet-Capable Conductivity Probe

Two-sensor electrical conductivity probes have been widely used for detailed local measurement in two-phase flow systems. However application of conductivity probes in liquid-dispersed flows has been limited. In the churn-turbulent to annular transition and annular flow regimes, the liquid phase exists as a continuous phase in the film and ligaments, and as a dispersed phase in the droplets. The conventional design of a conductivity probe is not valid because it cannot distinguish the dispersed liquid phase from the gas phase. In this paper, the Two-Sensor Droplet-Capable Conductivity Probe (DCCP-2) is designed in order to extend measurement capability to liquid-dispersed flows. The liquid phase is classified into droplets and ligaments. The interface velocity, volume fraction, interfacial area concentration, as well as the chord length of liquid droplets and ligaments, can be calculated from the raw signal. The radial distribution of these parameters and the probability distribution of chord length and velocity are obtained for downwards flow in a vertical pipe. The results show that although the average volume fraction of droplets is only on the order of 1%, droplets contribute to around 20%-30% to the entrained liquid phase in the gas core, the remainder as ligaments. The interfacial area concentration from droplets and ligaments are in the order of 300 m{sup -1}. (authors)

42 ENGINEERING↗

Probing the z > 6 universe with the first Hubble frontier fields cluster A2744

The Hubble Frontier Fields program combines the capabilities of the Hubble Space Telescope (HST) with the gravitational lensing of massive galaxy clusters to probe the distant universe to an unprecedented depth. Here, we present the results of the first combined HST and Spitzer observations of the cluster A-2744. We combine the full near-infrared data with ancillary optical images to search for gravitationally lensed high-redshift (z ≳ 6) galaxies. We report the detection of 15 I {sub 814} dropout candidates at z ∼ 6-7 and one Y {sub 105} dropout at z ∼ 8 in a total survey area of 1.43 arcmin{sup 2} in the source plane. The predictions of our lens model also allow us to identify five multiply imaged systems lying at redshifts between z ∼ 6 and z ∼ 8. Thanks to constraints from the mass distribution in the cluster, we were able to estimate the effective survey volume corrected for completeness and magnification effects. This was in turn used to estimate the rest-frame ultraviolet luminosity function (LF) at z ∼ 6-8. Our LF results are generally in agreement with the most recent blank field estimates, confirming the feasibility of surveys through lensing clusters. Although based on a shallower observations than what will be achieved in the final data set including the full Advanced Camera for Survey observations, the LF presented here goes down to M {sub UV} ∼–18.5, corresponding to 0.2L {sup *} at z ∼ 7 with one identified object at M {sub UV} ∼–15 thanks to the highly magnified survey areas. This early study forecasts the power of using massive galaxy clusters as cosmic telescopes and its complementarity to blank fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues.

60 APPLIED LIFE SCIENCES↗

Solar excitation of CdS/Cu2S photovoltaic cells

Solar radiation of five typical clear weather days and under a variety of conditions is used to determine the spectral distribution of the photonflux at different planes of a CdS/Cu2S solar cell. The fractions of reflected and absorbed flux are determined at each of the relevant interfaces and active volume elements of the solar cell. The density of absorbed photons is given in respect to spectral and spatial distribution. The variance of the obtained distribution, with changes in insolation and absorption spectra of the active solar cell layers, is indicated. A catalog of typical examples is given in the appendix.

Boer, K. W.↗

Mapping Aerosol Lidar Ratios Over Ocean Using Constrained Retrievals and A Global Aerosol Model

The current NASA Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) algorithms assign one lidar ratio (i.e., extinction-to-backscatter ratio; LR) value globally for each of the seven tropospheric aerosol types. In a future data products release, the CALIPSO project aims to improve these algorithms through the development of regional and seasonal LR climatologies. In this work, aerosol LRs are inferred through Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) backscatter profiles constrained by collocated aerosol optical depth (AOD) from Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data. This analysis is subsampled for those profiles that are cloud-free and contain only one CALIOP-classified aerosol type (e.g., marine). The CALIOP profiles are then collocated with aerosol volume fractions obtained through Goddard Chemistry Aerosol Radiation and Transport (GOCART) model simulations. In this presentation, we show that the twelve-year (June 2006-August 2018) mean spatial distributions of inferred aerosol LRs for CALIOP-classified marine aerosols correspond inversely with patterns of GOCART sea salt volume fraction (SSVF). For example, smaller SSVFs (< 65%) and larger LRs (> 55 sr), are found near land masses. This is indicative of the influence of over-land aerosols (e.g., pollution and biomass burning smoke). In the remote oceans (i.e., regions likely less impacted by non-sea salt aerosols), larger SSVFs (> 95%) and smaller LRs (< 25 sr) are found. The developed relationship between the GOCART SSVFs and MODIS AOD constrained LRs (polynomial fit intersect values of ~56 sr for SSVF of 0% and ~21 sr for SSVF of 100%) is used to produce model-assisted climatological LR maps on seasonal scales. Additionally, we show maps of inferred LRs from constrained retrievals using the CALIPSO Ocean Derived Column Optical Depth (ODCOD) product and comparisons with those from the MODIS analyses. The technique demonstrated in this study not only benefits CALIPSO in the near-term, but similar methods can be applied to future spaceborne elastic backscatter lidars with collocated passive sensors, such as those associated with the upcoming NASA Atmosphere Observing System (AOS).

Travis Toth↗

Soot Volume Fraction Maps for Normal and Reduced Gravity Laminar Acetylene Jet Diffusion Flames

The study of soot particulate distribution inside gas jet diffusion flames is important to the understanding of fundamental soot particle and thermal radiative transport processes, as well as providing findings relevant to spacecraft fire safety, soot emissions, and radiant heat loads for combustors used in air-breathing propulsion systems. Compared to those under normal gravity (1-g) conditions, the elimination of buoyancy-induced flows is expected to significantly change the flow field in microgravity (O g) flames, resulting in taller and wider flames with longer particle residence times. Work by Bahadori and Edelman demonstrate many previously unreported qualitative and semi-quantitative results, including flame shape and radiation, for sooting laminar zas jet diffusion flames. Work by Ku et al. report soot aggregate size and morphology analyses and data and model predictions of soot volume fraction maps for various gas jet diffusion flames. In this study, we present the first 1-g and 0-g comparisons of soot volume fraction maps for laminar acetylene and nitrogen-diluted acetylene jet diffusion flames. Volume fraction is one of the most useful properties in the study of sooting diffusion flames. The amount of radiation heat transfer depends directly on the volume fraction and this parameter can be measured from line-of-sight extinction measurements. Although most Soot aggregates are submicron in size, the primary particles (20 to 50 nm in diameter) are in the Rayleigh limit, so the extinction absorption) cross section of aggregates can be accurately approximated by the Rayleigh solution as a function of incident wavelength, particles' complex refractive index, and particles' volume fraction.

Greenberg, Paul S.↗

MO-FG-CAMPUS-IeP1-03: Establishment of Provincial Diagnostic Reference Levels in Pediatric Imaging

Purpose: To establish provincial diagnostic reference levels (DRLs) in pediatric general radiography and computed tomography (CT) as a tool for the optimization of exposure parameters. Methods: Patient dose survey was conducted in the only pediatric hospital in the province of Nova Scotia. The DRLs were established as the 75th percentile of patient dose distributions in different age groups. For routine radiography projections the DRLs were determined in terms of entrance surface dose (ESD) calculated from the radiation output measurements and the tube current-exposure time product (mAs) recorded for each examination. Patient thickness was measured by the technologist during the examination. The CR and DR systems, employing respectively a fixed technique and phototiming, were evaluated separately; a two-tailed Student’s t-test was used to determine the significance of differences between the means of dose distributions. The CT studies included routine head, chest, abdomen/pelvis, and chest/abdomen/pelvis. The volume CT dose index (CTDIvol) and dose-length product (DLP) values were extracted retrospectively from PACS. The correction factors based on the effective diameter of the patient were applied to the CT dosimetry metrics based on the standard phantoms. Results: The provincial DRLs were established in the following age groups: newborn, 1, 5, 10, and 15 year olds. In general radiography the DR systems demonstrated slightly lower dose than the CR for all views, however the differences were not statistically significant (p > 0.05) for all examinations. In CT the provincial DRLs were lower than the published data, except for head DLPs in all age categories. This might be due to the small patient sample size in the survey. Future work will include additional CT data collection over an extended period of time. Conclusion: Provincial DRLs were established in the dedicated children’s hospital to provide guidance for the other facilities in examinations of pediatric patients.

60 APPLIED LIFE SCIENCES↗

Precise and high-speed control of partial pressures of multiple gas species in plasma process chamber using pulse-controlled gas injection

Multiprocesses in a single plasma process chamber with high throughput require precise, sequential, high-speed alteration of partial pressures of multiple gas species. A conventional gas-distribution system cannot realize this because the system seriously overshoots gas pressure immediately following valve operation. Furthermore, chamber volume and conductance of gas piping between the system and chamber should both be considered because they delay the stabilizing time of gas pressure. Therefore, the authors proposed a new gas-distribution system without overshoot by controlling gas flow rate based on pressure measurement, as well as a method of pulse-controlled gas injection immediately following valve operation. Time variation of measured partial pressure agrees well with a calculation based on an equivalent-circuit model that represents the chamber and gas piping between the system and chamber. Using pulse-controlled gas injection, the stabilizing time can be reduced drastically to 0.6 s for HBr added to pure Ar plasma, and 0.7 s for O{sub 2} added to Ar/HBr plasma; without the pulse control, the stabilizing times are 3 and 7 s, respectively. In the O{sub 2} addition case, rapid stabilization can be achieved during the period of line/space pattern etching of poly-Si on a thin SiO{sub 2} film. This occurs without anomalous etching of the underlying SiO{sub 2} film or the Si substrate near the sidewall, thus obtaining a wide process margin with high throughput.

36 MATERIALS SCIENCE↗

Concerning neutral flux shielding in the U-3M torsatron

The volume of the torsatron U-3M vacuum chamber is about 70 m{sup 3}, whereas the plasma volume is about 0.3 m{sup 3}. The large buffer volume of the chamber serves as a source of a substantial neutral flux into the U-3M plasma. A fraction of this flux falls onto the torsatron helical coils located in front of the plasma, due to which the dynamics of neutral influx into the plasma modifies. The shielding of the molecular flux from the buffer volume into the plasma is estimated using numerical calculations. Only about 10% of the incident flux reaches the plasma volume. Estimates show that about 20% of atoms escape beyond the helical coils without colliding with them. Under these conditions, the helical coils substantially affect the neutral flux. A discharge regime with a hot low-density plasma produced by a frame antenna is considered. The spatial distribution of the molecular density produced in this regime by the molecular flux from the chamber buffer volume after it has passed between the helical coils is calculated. The contributions of the fluxes emerging from the side and inner surfaces of the helical coils are considered. The calculations show that the shape of the spatial distribution of the molecular density differs substantially from the shape of the magnetic surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incorporating uncertainties in respiratory motion into 4D treatment plan optimization

The purpose of this work is to investigate robust 4D optimization techniques which account for respiratory motion uncertainties. Two robust optimization techniques were applied to generate 4D optimized lung treatment plans. The probabilistic optimization approach minimizes the dose variance in the target volume while the worst case optimization minimizes a weighted combination of the nominal and worst case dose distributions which occur in the presence of respiratory motion variation. The two 4D optimization approaches were compared with a margin-based midventilation planning approach in five lung patients. Respiratory motion amplitude and baseline variations were quantified from tidal volume measurements during planning 4D CT acquisition. A similar target coverage was obtained for all three approaches, although the 4D optimization methods tended to be better at sparing the organs at risk. Both robust planning methods are suited for automatic determination of treatment plans which ensure target dose conformality under respiratory motion variations, while minimizing the dose burden of healthy lung tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗