Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tin”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Dose optimization in pediatric cardiac x-ray imaging

Purpose: The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance for pediatric patient sizes. The impact of antiscatter grid removal on the image quality to dose balance was also investigated. Methods: Image sequences of polymethyl methacrylate phantoms approximating chest sizes typical of pediatric patients were captured using a modern flat-panel receptor based x-ray imaging system. Tin was used to simulate iodine-based contrast medium used in clinical procedures. Measurements of tin detail contrast and flat field image noise provided the contrast to noise ratio. Entrance surface dose (ESD) and effective dose (E) measurements were obtained to calculate the figure of merit (FOM), CNR{sup 2}/dose, which evaluated the dose efficiency of the x-ray parameters investigated. The kVp, tube current (mA), and pulse duration were set manually by overriding the system's automatic dose control mechanisms. Images were captured with 0, 0.1, 0.25, 0.4, and 0.9 mm added Cu filtration, for 50, 55, 60, 65, and 70 kVp with the antiscatter grid in place, and then with it removed. Results: For a given phantom thickness, as the Cu filter thickness was increased, lower kVp was favored. Examining kVp alone, lower values were generally favored, more so for thinner phantoms. Considering ESD, the 8.5 cm phantom had the highest FOM at 50 kVp using 0.4 mm of Cu filtration. The 12 cm phantom had the highest FOM at 55 kVp using 0.9 mm Cu, and the 16 cm phantom had highest FOM at 55 kVp using 0.4 mm Cu. With regard to E, the 8.5 and 12 cm phantoms had the highest FOM at 50 kVp using 0.4 mm of Cu filtration, and the 16 cm phantom had the highest FOM at 50 kVp using 0.25 mm Cu. Antiscatter grid removal improved the FOM for a given set of x-ray conditions. Under aforesaid optimal settings, the 8.5 cm phantom FOM improved by 24% and 33% for ESD and E, respectively. Corresponding improvements were 26% and 24% for the 12 cm phantom and 6% and 15% for the 16 cm phantom. Conclusions: For pediatric patients, using 0.25-0.9 mm Cu filtration in the x-ray beam while maintaining 50-55 kVp, depending on patient size, provided optimal x-ray image quality to dose ratios. These settings, adjusted for x-ray tube loading limits and clinically acceptable image quality, should provide a useful strategy for optimizing iodine contrast agent based cardiac x-ray imaging. Removing the antiscatter grid improved the FOM for the 8.5 and 12 cm phantoms, therefore grid removal is recommended for younger children. Improvement for the 16 cm phantom declined into the estimated margin of error for the FOM; the need for grid removal for older children would depend on practical feasibility in the clinical environment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-88: Field’s Metal for Electron Beam Inserts and Blocks

Purpose: The aim of this work is to show that Field’s metal can be used as a viable alternative material to lead-based low-melting temperature alloys (e.g., Cerrobend) for electron beam inserts and blocks. The goal is to eliminate exposure risks associated with lead and cadmium. Methods: Field’s metal (51% Indium, 32.5% Bismuth, 16.5% Tin) is a low-melting point eutectic alloy, and is proposed as a lead-free replacement for Cadmium-free alloy (52.5% Bismuth, 32% Lead, 15.5% Tin). The experiments were done using a Varian 21EX linac equipped with 6, 9, 12, and 16 MeV beams. The 10×10 cone was used with 1.8cm thick insert made of Fields metal, Cd-Free alloy or open field. The transmitted radiation was measured using a diode at various depths in water. Block transmission factor (BTF) is determined as the ratio of maximum transmission radiation dose over the dose at dmax of the open field. Results: The data shows BTFs for both alloys are very similar, well below 5% for 6, 9, and 12 MeV beams. For 16 MeV, the BTF of the Fields metal is about 5.3%; the Cd-free metal 4.2%. The peak dose of the transmitted radiation occurs less than 1 cm below the water surface, at a much shallower depth than the dmax of the electron beam in the open field. The beam profile shows the maximum block transmission is along the central axis of the beam. Conclusion: The present study shows that Fields metal can be used to make electron cutouts and blocks for 6, 9, 12, and 16 MeV beams. Because it has a similar density as other lead-based alloys, the same thickness of Fields metal would be adequate for shielding the electron beams. This means that it can be used as a replacement without modification to the existing block holder.

43 PARTICLE ACCELERATORS↗

SU-F-T-424: Mitigation of Increased Surface Dose When Treating Through A Carbon Fiber Couch Top

Purpose: To study the effect of the Varian carbon fiber couch top on surface dose for patients being treated using single PA beams in the supine position and to identify simple methods for surface dose reduction. Methods: Measurements of surface dose were obtained in Solid Water phantoms using both a parallel plate ionization chamber (PTW Advanced Markus) and EBT2 Radiochromic films for both 6 and 10MV photons. All measurements were referenced to a depth considered a typical for PA Spine fields. Techniques used to reduce the surface dose included introducing an air standoff using Styrofoam sheets to suspend the phantom surface above the couch top and by adding a thin high Z scattering foil on the table surface. Surface doses were evaluated for typical field sizes, standoff heights, and various scattering materials. Comparisons were made to the surface dose obtainable when treating through a Varian Mylar covered tennis racket style couch top. Results: Dependence on typical spine field sizes was relatively minor. Dependence on air gap was much more significant. Surface doses decreased exponentially with increases in air standoff distance. Surface doses were reduced by approximately 50% for an air gap of 10cm and 40% for a 15cm air gap. Surface doses were reduced by an additional 15% by the addition of a 1mm Tin scattering foil. Conclusion: Using simple techniques, it is possible to reduce the surface dose when treating single PA fields through the Varian carbon fiber couch top. Surface doses can be reduced to levels observed when treating though transparent Mylar tops by adding about 15 cm of air gap. Further reductions are possible by adding thin scattering foils, such as Tin or Lead, on the couch surface. This is a low cost approach to reduce surface dose when using the Varian carbon fiber couch top.

07 ISOTOPE AND RADIATION SOURCES↗

Three-dimensional nanoscale metal, metal oxide, and semiconductor frameworks through DNA-programmable assembly and templating

Controlling the three-dimensional (3D) nanoarchitecture of inorganic materials is imperative for enabling their novel mechanical, optical, and electronic properties. Here, by exploiting DNA-programmable assembly, we establish a general approach for realizing designed 3D ordered inorganic frameworks. Through inorganic templating of DNA frameworks by liquid- and vapor-phase infiltrations, we demonstrate successful nanofabrication of diverse classes of inorganic frameworks from metal, metal oxide and semiconductor materials, as well as their combinations, including zinc, aluminum, copper, molybdenum, tungsten, indium, tin, and platinum, and composites such as aluminum-doped zinc oxide, indium tin oxide, and platinum/aluminum-doped zinc oxide. The open 3D frameworks have features on the order of nanometers with architecture prescribed by the DNA frames and self-assembled lattice. Structural and spectroscopic studies reveal the composition and organization of diverse inorganic frameworks, as well as the optoelectronic properties of selected materials. The work paves the road toward establishing a 3D nanoscale lithography.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electron microscopy study of an Old Russian (XII century) encolpion cross with black inlay

The phase compositions of the basic material (alloy) of a pre-Mongolian Old Russian encolpion cross found near Suzdal and its black inlay have been investigated by methods of scanning and transmission electron microscopy and energy-dispersive X-ray microanalysis. The cross material is lead–zinc–tin α-bronze, and the black is copper sulfide with lead inclusions. As a result of the corrosion, tin and copper oxides and zinc sulfides, which made the cross dark gray, were formed on its surface. It is shown that the corrosion depth is as large as 50 μm; thus, laps must be prepared to accurately determine the morphology and phase composition of the corrosion layer. Decoration with black was apparently performed by pouring with copper sulfide melt or melting a powder preliminarily placed in grooves forming an image on the surface.

36 MATERIALS SCIENCE↗

Silicon nanowire array architecture for heterojunction electronics

Photosensitive nanostructured heterojunctions n-TiN/p-Si were fabricated by means of titanium nitride thin films deposition (n-type conductivity) by the DC reactive magnetron sputtering onto nano structured single crystal substrates of p-type Si (100). The temperature dependencies of the height of the potential barrier and series resistance of the n-TiN/p-Si heterojunctions were investigated. The dominant current transport mechanisms through the heterojunctions under investigation were determined at forward and reverse bias. The heterojunctions under investigation generate open-circuit voltage V{sub oc} = 0.8 V, short-circuit current I{sub sc} = 3.72 mA/cm{sup 2} and fill factor FF = 0.5 under illumination of 100 mW/cm{sup 2}.

36 MATERIALS SCIENCE↗

Texturing in a Ni–W/TiN Thin-Film System

Double-layer thin-film compositions with a TiN coating based on a ferromagnetic Ni–5 at % W alloy and a paramagnetic Ni–9.5 at % W alloy have been prepared. Texturing in both components of the Ni–W/TiN system has been studied using X-ray diffraction analysis. It has been found that the coating layer causes crystal planes in the Ni–9.5 at % W strip to reorient and thereby enhances the cube texture in the substrate. It has been shown that under certain growth conditions, a thin TiN coating above the Ni–9.5 at % W/TiN substrate grows quasi-single-crystalline with a cube texture.

36 MATERIALS SCIENCE↗

Studies of LaSn{sub 3} as a negative electrode for lithium ion batteries.

The intermetallic compound LaSn{sub 3} has been explored as a possible negative electrode for lithium-ion batteries. A combination of experiment and density functional theory calculations provides evidence that the structure is intolerant to lithium insertion and that the electrochemical reaction occurs via a displacement mechanism. Experiment shows that approximately six Li react initially with LaSn{sub 3}; calculated energetics suggest that during the reaction La{sub 3}Sn{sub 5} and lithiated tin are formed and that the electrode operates by delithiation and relithiation of the Sn particles within an inert lanthanum-tin matrix. LaSn{sub 3} electrodes provide a reversible specific capacity of 200-250 mAh/g, whereas In-substituted electrodes that form a solid solution with LaSn{sub 3}, such as LaSn{sub 2.7}In{sub 0.3}, yield a slightly lower capacity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sustainable production of radionuclidically pure antimony-119

Background Radiopharmaceutical therapy (RPT) uses radionuclides that decay via one of three therapeutically relevant decay modes (alpha, beta, and internal conversion (IC) / Auger electron (AE) emission) to deliver short range, highly damaging radiation inside of diseased cells, maintaining localized dose distribution and sparing healthy cells. Antimony-119 ( 119 Sb, t 1/2 = 38.19 h, EC = 100%) is one such IC/AE emitting radionuclide, previously limited to in silico computational investigation due to barriers in production, chemical separation, and chelation. A theranostic (therapeutic/diagnostic) pair can be formed with 119 Sb’s radioisotopic imaging analogue 117 Sb (t 1/2 = 2.80 h, E γ = 158.6 keV, I γ = 85.9%, β + = 262.4 keV, I β+ = 1.81%). Results Within, we report techniques for sustainable and cost-effective production of pre-clinical quality and quantity, radionuclidically pure 119 Sb and 117 Sb, novel low energy photon measurement techniques for 119 Sb activity determination, and physical yields for various tin target isotopic enrichments and thicknesses using (p, n) and (d, n) nuclear reactions. Additionally, we present a two-column separation providing a radioantimony yield of 73.1% ± 6.9% (N = 3) and tin separation factor of (6.8 ± 5.5) x 10 5 (N = 3). Apparent molar activity measurements for deuteron produced 117 Sb using the chelator TREN-CAM were measured at 42.4 ± 25 MBq 117 Sb/µmol (1.14 ± 0.68 mCi/µmol), and we recovered enriched 119 Sn target material at a recycling efficiency of 80.2% ± 5.5% (N = 6) with losses of 11.6 mg ± 0.8 mg (N = 6) per production. Conclusion We report significant steps in overcoming barriers in 119 Sb production, chemical isolation and purification, enriched target material recycling, and chelation, helping promote accessibility and application of this promising therapeutic radionuclide. We describe a method for 119 Sb activity measurement using its low energy gamma (23.87 keV), negating the need for attenuation correction. Finally, we report the largest yet-measured 119 Sb production yields using proton and deuteron irradiation of natural and enriched targets and radioisotopic purity > 99.8% at end of purification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Giant optical second- and third-order nonlinearities at a telecom wavelength

A material platform that excels in both optical second- and third-order nonlinearities at a telecom wavelength is theoretically and experimentally demonstrated. In this TiN-based coupled metallic quantum well structure, electronic subbands are engineered to support doubly resonant inter-subband transitions for an exceptionally high second-order nonlinearity and provide single-photon transitions for a remarkable third-order nonlinearity within the 1400–1600 nm bandwidth. The second-order susceptibility χ (2) reaches 2840 pm/V at 1440 nm, while the Kerr coefficient n 2 arrives at 2.8 × 10 −10 cm 2 /W at 1460 nm. The achievement of simultaneous strong second- and third-order nonlinearities in one material at a telecom wavelength creates opportunities for multi-functional advanced applications in the field of nonlinear optics.

Chen, Ching-Fu (ORCID:0000000262510722)↗

Out-of-reactor test of corrosion and hydrogen pickup in fuel cladding materials in contact with nickel metal - 2016-0038

Increased reactor coolant hydrogen concentration in pressurized water reactors (PWRs) is under consideration for potential benefits in reducing primary water stress corrosion cracking (PWSCC) crack growth rate as well as increasing PWSCC crack initiation time in nickel-based alloys. Potential concerns related to fuel performance include possible increases in hydrogen pickup (HPU) by zirconium based alloys and the enhancement of the pickup through the so-called nickel-window effect. Although the risk of this occurrence may be low, the consequences of increased HPU could be substantial. We examined the impact of dissolved hydrogen (DH) concentrations on Zircaloy-4 corrosion and HPU when the samples are in contact with nickel sources. The work was completed in conjunction with a large project that evaluated the impact of dissolved hydrogen on various fuel cladding and spacer weld specimens of M5{sup R}, ZIRLO{sup R}, Optimized ZIRLO{sup TM}, Low-Tin ZIRLO{sup TM}, Optimized Low-Tin Zircaloy-4, and Zircaloy-2 in either as-received or pre-oxidized conditions for exposures up to 730 days in high-pressure, out-of-reactor autoclave systems operating with a simulated PWR coolant at three different DH concentrations: 30, 100, and 500 cm{sup 3} (cc) H{sub 2}/kg H{sub 2}O. A significant increase in HPU was observed for some Zircaloy-4 specimens in contact with synthetic crud at elevated DH levels. The HPU increased with increasing DH and a metallic nickel fraction in the synthetic crud. The formation of metallic nickel in the synthetic crud samples at elevated DH levels was confirmed. (authors)

36 MATERIALS SCIENCE↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Low RF loss DC conductive ceramic for RF windows

Charging of RF windows has historically been problematic, frequently resulting in damage to the window severe enough that the window needs to be replaced. Many attempts have been made to prevent charging and therefore improve window lifetime, the most successful and common of which is coating the window with titanium nitride (TiN). Surface coatings such as TiN rely on the secondary electron yield of the coating material being lower than that of the ceramic window material, reducing the number of electrons emitted from a variety of mechanisms. An alternative approach is to introduce a small amount of DC conductivity to the ceramic itself, turning the traditionally insulating window into a mildly conductive one. This allows any charge on the surface of the window to drain rather than build until a discharge happens. A magnesium titanate ceramic has been developed with a small DC conductivity and used to make RF windows. Several window assemblies have been produced and tested, including 1.3 GHz waveguide and 650 MHz coaxial designs. The results of the conductive ceramic window test program will be presented.

43 PARTICLE ACCELERATORS↗

Testing and Processing of Pre-production 325 MHz Single Spoke Resonator Power Couplers for PIP-II Project

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

43 PARTICLE ACCELERATORS↗

TECHNOLOGY EVALUATION FOR WATERBORNE MERCURY REMOVAL AT THE Y12 NATIONAL SECURITY COMPLEX

The Hg-contaminated processing water produced at Y-12 facility is discharged through the storm drain system, merged at Outfall 200, and then discharged to EFPC. Most of the baseflow mercury at Outfall 200 arises from a small number of short sections of storm drain. This report discusses the waterborne mercury treatment technologies to decrease mercury loading to the surface water of EFPC at Y-12 NSC. We reviewed current available waterborne Hg treatment technologies based on the specific conditions of Y-12 and identified two possible options: SnCl2 reduction coupled with air stripping (SnCl2/air stripping) and sorption. The ORNL 2008 and 2009 field studies suggested that SnCl2/air stripping has the capability to remove waterborne mercury with efficiency higher than 90% at Outfall 200. To achieve this goal, dechlorination (i.e., removing residual chlorine from water) using dechlorinating agents such as thiosulfate has to be performed before the reduction. It is unclear whether or not SnCl2/air stripping can reduce the mercury concentration from ~1000 ng/L to 51 ng/L at a full-scale operation. Therefore, a pilot test is a logical step before a full-scale design to answer questions such as Hg removal efficiency, selection of dechlorinating agents, and so on. The major advantages of the SnCl2/air stripping system are: (1) expected low cost at high flow (e.g., the flow at Outfall 200); and (2) production of minimum secondary waste. However, there are many environmental uncertainties associated with this technology by introducing tin to EFPC ecosystem, for example tin methylation causing abiotic Hg methylation, which should be addressed before a full-scale implementation. Mercury adsorption by granular activated carbon (GAC) is a proven technology for treating Hg at Y-12. The ONRL 2010 lab sorption studies suggest that thiol-based resins hold the promise to combine with GAC to form a more cost-effective treatment system. To achieve a treatment goal of 51 ng/L at Outfall 200 (flow rate: 1300 gpm), using a single GAC system will request very large reaction vessels and cost much more than a SnCl2/air stripping system (assuming it can achieve the 51 ng/L goal). However, the treatment cost depends on the treatment goal. If the treatment goal is 200 ng/L, the cost of GAC system will be significantly reduced while the cost of SnCl2/air stripping will remain the same. In addition, a GAC coupled with thiol-based resin system may further reduce the cost. Treating the Hg-contaminated water at source area with low flow rate (e.g., 40 gpm) may be another option to reduce the treatment cost. The advantages of the sorption technology are that it has proven treatment efficiency, reliability, and no environmental uncertainties. The disadvantages include that it produces large amount of secondary wastes. Based on the information evaluated in this report, we recommend that a pilot-scale test for SnCl2/air stripping process at Outfall 200 should be carried out before a full-scale implementation to address all the engineering and environmental risk questions. We also recommend continuing the sorbent lab studies at ORNL to optimize a sorption system that may be efficient and cost-effective enough for a full-scale implementation.

He, Feng↗

Electron Cloud in Steel Beam Pipe vs Titanium Nitride Coated and Amorphous Carbon Coated Beam Pipes in Fermilab's Main Injector

This paper documents the use of four retarding field analyzers (RFAs) to measure electron cloud signals created in Fermilab’s Main Injector during 120 GeV operations. The first data set was taken from September 11, 2009 to July 4, 2010. This data set is used to compare two different types of beam pipe that were installed in the accelerator. Two RFAs were installed in a normal steel beam pipe like the rest of the Main Injector while another two were installed in a one meter section of beam pipe that was coated on the inside with titanium nitride (TiN). A second data run started on August 23, 2010 and ended on January 10, 2011 when Main Injector beam intensities were reduced thus eliminating the electron cloud. This second run uses the same RFA setup but the TiN coated beam pipe was replaced by a one meter section coated with amorphous carbon (aC). This section of beam pipe was provided by CERN in an effort to better understand how an aC coating will perform over time in an accelerator. The research consists of three basic parts: (a) continuously monitoring the conditioning of the three different types of beam pipe over both time and absorbed electrons (b) measurement of the characteristics of the surrounding magnetic fields in the Main Injector in order to better relate actual data observed in the Main Injector with that of simulations (c) measurement of the energy spectrum of the electron cloud signals using retarding field analyzers in all three types of beam pipe.

Backfish, Michael↗

In-Situ Silver Acetylide Silver Nitrate Explosive Deposition Measurements Using X-Ray Fluorescence.

The Light Initiated High Explosive facility utilized a spray deposited coating of silver acetylide - silver nitrate explosive to impart a mechanical shock into targets of interest. A diagnostic was required to measure the explosive deposition in - situ. An X - ray fluorescence spectrometer was deployed at the facility. A measurement methodology was developed to measure the explosive quantity with sufficient accuracy. Through the use of a tin reference material under the silver based explosive, a field calibration relationship has been developed with a standard deviation of 3.2 % . The effect of the inserted tin material into the experiment configuration has been explored.

Covert, Timothy Todd↗