Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Effects of nitrogen ion implantation time on tungsten films deposited by DC magnetron sputtering on AISI 410 martensitic stainless steel

Nitrogen ion implantation time on tungsten thin film deposited on surface of AISI 410 steel has been performed. Tungsten thin film produced by dc magnetron sputtering method was deposited on AISI 410 martensitic stainless steel substrates, and then the nitrogen ions were implanted on tungsten thin film. The objective of this research is to investigate the effects of implantation deposition time on surface roughness, microhardness, specific wear and corrosion rate of nitrogen implanted on tungsten film. Magnetron sputtering process was performed by using plasma gas of argon (Ar) to bombardier tungsten target (W) in a vacuum chamber with a pressure of 7.6 x 10{sup −2} torr, a voltage of 300 V, a sputter current of 80 mA for sputtered time of 10 minutes. Nitrogen implantation on tungsten film was done with an initial pressure of 3x10{sup −6} mbar, a fluence of 2 x 10{sup 17} ions/cm{sup 2}, an energy of 100 keV and implantation deposition times of 0, 20, 30 and 40 minutes. The surface roughness, microhardness, specific wear and corrosion rate of the films were evaluated by surfcorder test, Vickers microhardness test, wear test and potentiostat (galvanostat) test respectively. The results show that the nitrogen ions implanted deposition time on tungsten film can modify the surface roughness, microhardness, specific wear and corrosion rate. The minimum surface roughness, specific wear and corrosion rate can be obtained for implantation time of 20 minutes and the maximum microhardness of the film is 329 VHN (Vickers Hardness Number) for implantation time of 30 minutes. The specific wear and corrosion rate of the film depend directly on the surface roughness.

36 MATERIALS SCIENCE↗

Distribution of tunnelling times for quantum electron transport

In electron transport, the tunnelling time is the time taken for an electron to tunnel out of a system after it has tunnelled in. We define the tunnelling time distribution for quantum processes in a dissipative environment and develop a practical approach for calculating it, where the environment is described by the general Markovian master equation. We illustrate the theory by using the rate equation to compute the tunnelling time distribution for electron transport through a molecular junction. The tunnelling time distribution is exponential, which indicates that Markovian quantum tunnelling is a Poissonian statistical process. The tunnelling time distribution is used not only to study the quantum statistics of tunnelling along the average electric current but also to analyse extreme quantum events where an electron jumps against the applied voltage bias. The average tunnelling time shows distinctly different temperature dependence for p- and n-type molecular junctions and therefore provides a sensitive tool to probe the alignment of molecular orbitals relative to the electrode Fermi energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Finding the “lost-time” in detonator function

Exploding bridgewire (EBW) detonators were invented during the Manhattan Project over 75 years ago. Initially developed for precise timing and reproducibility, they continue to be used in many applications. Despite widespread use and reliability, their mechanism for function remains controversial. They provide precision timing, yet their function is described in terms of a “lost time” accounting for nearly half of the function time. Buried in understanding the EBW function is the mystery of how an incoherent impulse such as powering a bridgewire yields the coherent energy output of a detonation. Even the general phenomena by which release of chemical energy in a crystalline organic explosive becomes associated with the sonic plane of a steady detonation wave remain uncertain. Here, we investigate the EBW function with a suite of diagnostics and show that stationary heating occurs during the “lost-time.” We use x-ray radiography to observe the propagation of a shock wave from bridgewire vaporization and establish that the origin of the radially emanating detonation wave is spatially separated from the initial shock. Utilizing the observed temperature as a boundary condition in our explosive response models yields a thermal ignition consistent with the “lost-time” and detonation location consistent with previous work. With these findings, we define a direct thermal initiation mechanism for the EBW function consistent with previous integral observations and explain the displacement of initiation from the bridgewire burst in time and space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining velocity of detonation using high-resolution time domain reflectometry

Two methods are presented to make measurements of the length of a coaxial cable with submillimeter and submicrosecond accuracy. If the cable is destroyed by the passage of a strong shock, for instance, from the detonation of an explosive, a measure of the phase velocity of the detonation (VOD) can be obtained with high accuracy (≈0.25%). The first method introduces a series of short Gaussian electrical pulses (<300 ps) into the cable that reflect off the cable end and are compared to the time of the original outgoing pulse by using a fast digitizer (100 gigasamples per second). By curve fitting a Gaussian form to the outgoing and reflected pulses, a measurement of the cable length can be made with subsample accuracy. So, as long as the pulses do not overlap, a large number may be present in the cable at any time allowing pulse repetition rates of 40–135 MHz depending on the cable length. Averaging allows accurate VOD measurements to be made that are comparable with the best traditional techniques. The second method replaces the pulser with a wide-spectrum (0.1–10 GHz) amplified random noise source. A similar setup and digitizer are used before autocorrelating short (80–160 ns) subsamples of the total waveform to measure the reflected delay time. That is, a smaller amplitude version of the original waveform appears time shifted by twice the transit time in the cable and this time is estimated via autocorrelation. The advantage of this method is that a new subsample needs only to be selected from a time increment in which new spectral information is present for a new measure of the length to be made. In this manner, many more length estimates can be averaged to establish the VOD than with the Gaussian approach. As a result, a detailed description of the implementation of both methods is presented together with an example of the type of data collected and limitations found.

47 OTHER INSTRUMENTATION↗

A time-resolved, in-chamber x-ray pinhole imager for Z

We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.

47 OTHER INSTRUMENTATION↗

Design of the high-yield time-gated x-ray hot-spot imager for OMEGA

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester’s OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium–tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick–Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 10 14 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 μm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal–oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. As a result, the technical design space for the instrument will be discussed and the conceptual design will be presented.

47 OTHER INSTRUMENTATION↗

Real-time steerable frequency-stepped Doppler backscattering (DBS) system for local helicon wave electric field measurements on the DIII-D tokamak

A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20–550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60–90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally “tagged” with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Coherence Conversion for Optimized Resolution in Optical Measurements - Example of Femtosecond Time Resolution Using the Transverse Coherence of 100-Picosecond X-Rays

A way is proposed to obtain a femtosecond time resolution over a picosecond range in x-ray spectroscopic measurements where the light source and the detector are much slower than that. It is based on the invariance of the modulus of the Fourier transform to object translations. The method geometrically correlates time in the sample with x-ray amplitudes over a spatial coordinate, and then takes the optical Fourier transform through far-field diffraction. Thus, explicitly time-invariant intensities that encode the time evolution of the sample can be measured with a slow detector. This corresponds to a phase-space transformation that converts the transverse coherence to become effective in the longitudinal direction. Because synchrotron-radiation sources have highly anisotropic coherence properties with about $10^5$ longitudinal electromagnetic-field modes at 1 eV bandwidth, but only tens to hundreds transverse modes, coherence conversion can drastically improve the time resolution. Reconstruction of the femtosecond time evolution in the sample from the Fourier intensities is subject to a phase ambiguity that is well-known in crystallography. However, a way is presented to resolve it that is not available in that discipline. Finally, data from a demonstration experiment are presented. The same concept can be used to obtain attosecond time resolution with an x-ray free-electron laser.

Adams, Bernhard W.↗

A TRANSIT TIMING ANALYSIS OF NINE RISE LIGHT CURVES OF THE EXOPLANET SYSTEM TrES-3

We present nine newly observed transits of TrES-3, taken as part of a transit timing program using the RISE instrument on the Liverpool Telescope. A Markov-Chain Monte Carlo analysis was used to determine the planet-star radius ratio and inclination of the system, which were found to be R{sub p} /R {sub *} = 0.1664{sup +0.0011} {sub -0.0018} and i = 81.73{sup +0.13} {sub -0.04}, respectively, consistent with previous results. The central transit times and uncertainties were also calculated, using a residual-permutation algorithm as an independent check on the errors. A re-analysis of eight previously published TrES-3 light curves was conducted to determine the transit times and uncertainties using consistent techniques. Whilst the transit times were not found to be in agreement with a linear ephemeris, giving {chi}{sup 2} = 35.07 for 15 degrees of freedom, we interpret this to be the result of systematics in the light curves rather than a real transit timing variation. This is because the light curves that show the largest deviation from a constant period either have relatively little out-of-transit coverage or have clear systematics. A new ephemeris was calculated using the transit times and was found to be T{sub c} (0) = 2454632.62610 {+-} 0.00006 HJD and P = 1.3061864 {+-} 0.0000005 days. The transit times were then used to place upper mass limits as a function of the period ratio of a potential perturbing planet, showing that our data are sufficiently sensitive to have probed sub-Earth mass planets in both interior and exterior 2:1 resonances, assuming that the additional planet is in an initially circular orbit.

99 GENERAL AND MISCELLANEOUS↗

MULTI-INSTRUMENT X-RAY OBSERVATIONS OF THERMONUCLEAR BURSTS WITH SHORT RECURRENCE TIMES

Type I X-ray bursts from low-mass X-ray binaries result from a thermonuclear runaway in the material accreted onto the neutron star. Although typical recurrence times are a few hours, consistent with theoretical ignition model predictions, there are also observations of bursts occurring as promptly as 10 minutes or less after the previous event. We present a comprehensive assessment of this phenomenon using a catalog of 3387 bursts observed with the BeppoSAX/WFCs and RXTE/PCA X-ray instruments. This catalog contains 136 bursts with recurrence times of less than 1 hr, that come in multiples of up to four events, from 15 sources. Short recurrence times are not observed from the so-called ultra-compact binaries, indicating that hydrogen-burning processes play a crucial role. As far as the neutron star spin frequency is known, these sources all spin fast at over 500 Hz; the rotationally induced mixing may explain burst recurrence times of the order of 10 minutes. Short recurrence time bursts generally occur at all mass accretion rates where normal bursts are observed, but for individual sources the short recurrence times may be restricted to a smaller interval of accretion rate. The fraction of such bursts is roughly 30%. We also report the shortest known recurrence time of 3.8 minutes.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE COMPLEMENTARITY OF PULSAR TIMING AND SPACE LASER INTERFEROMETRY FOR THE INDIVIDUAL DETECTION OF SUPERMASSIVE BLACK HOLE BINARIES

Gravitational waves coming from supermassive black hole binaries (SMBHBs) are targeted by both the Pulsar Timing Array (PTA) and Space Laser Interferometry (SLI). The possibility of a single SMBHB being tracked first by PTA, through inspiral, and later by SLI, up to merger and ring-down, has been previously suggested. Although the bounding parameters are drawn by the current PTA or the upcoming Square Kilometer Array (SKA), and by the New Gravitational Observatory (NGO), derived from the Laser Interferometer Space Antenna (LISA), this paper also addresses sequential detection beyond specific project constraints. We consider PTA-SKA, which is sensitive from 10{sup -9} to p Multiplication-Sign 10{sup -7} Hz (p = 4, 8), and SLI, which operates from s Multiplication-Sign 10{sup -5} up to 1 Hz (s = 1, 3). An SMBHB in the range of 2 Multiplication-Sign 10{sup 8}-2 Multiplication-Sign 10{sup 9} M {sub Sun} (the masses are normalized to a (1 + z) factor, the redshift lying between z = 0.2 and z = 1.5) moves from the PTA-SKA to the SLI band over a period ranging from two months to fifty years. By combining three supermassive black hole (SMBH)-host relations with three accretion prescriptions, nine astrophysical scenarios are formed. They are then related to three levels of pulsar timing residuals (50, 5, 1 ns), generating 27 cases. For residuals of 1 ns, sequential detection probability will never be better than 4.7 Multiplication-Sign 10{sup -4} yr{sup -2} or 3.3 Multiplication-Sign 10{sup -6} yr{sup -2} (per year to merger and per year of survey), according to the best and worst astrophysical scenarios, respectively; put differently this means one sequential detection every 46 or 550 years for an equivalent maximum time to merger and duration of the survey. The chances of sequential detection are further reduced by increasing values of the s parameter (they vanish for s = 10) and of the SLI noise, and by decreasing values of the remnant spin. The spread in the predictions diminishes when timing precision is improved or the SLI low-frequency cutoff is lowered. So while transit times and the SLI signal-to-noise ratio (S/N) may be adequate, the likelihood of sequential detection is severely hampered by the current estimates on the number-just a handful-of individual inspirals observable by PTA-SKA, and to a lesser extent by the wide gap between the pulsar timing and space interferometry bands, and by the severe requirements on pulsar timing residuals. Optimization of future operational scenarios for SKA and SLI is briefly dealt with, since a detection of even a single event would be of paramount importance for the understanding of SMBHBs and of the astrophysical processes connected to their formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Clues to the nature of SN 2009ip from photometric and spectroscopic evolution to late times

We present time series photometric and spectroscopic data for the transient SN 2009ip from the start of its outburst in 2012 September until 2013 November. These data were collected primarily with the new robotic capabilities of the Las Cumbres Observatory Global Telescope Network, a specialized facility for time domain astrophysics, and includes supporting high-resolution spectroscopy from the Southern Astrophysical Research Telescope, Kitt Peak National Observatory, and Gemini Observatory. Based on our nightly photometric monitoring, we interpret the strength and timing of fluctuations in the light curve as interactions between fast-moving ejecta and an inhomogeneous circumstellar material (CSM) produced by past eruptions of this massive luminous blue variable (LBV) star. Our time series of spectroscopy in 2012 reveals that, as the continuum and narrow Hα flux from CSM interactions declines, the broad component of Hα persists with supernova (SN)-like velocities that are not typically seen in LBVs or SN impostor events. At late times, we find that SN 2009ip continues to decline slowly, at ≲ 0.01 mag day{sup –1}, with small fluctuations in slope similar to Type IIn supernovae (SNe IIn) or SN impostors but no further LBV-like activity. The late-time spectrum features broad calcium lines similar to both late-time SNe and SN impostors. In general, we find that the photometric and spectroscopic evolution of SN 2009ip is more similar to SNe IIn than either continued eruptions of an LBV star or SN impostors but we cannot rule out a nonterminal explosion. In this context, we discuss the implications for episodic mass loss during the late stages of massive star evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

PULSAR TIMING ERRORS FROM ASYNCHRONOUS MULTI-FREQUENCY SAMPLING OF DISPERSION MEASURE VARIATIONS

Free electrons in the interstellar medium cause frequency-dependent delays in pulse arrival times due to both scattering and dispersion. Multi-frequency measurements are used to estimate and remove dispersion delays. In this paper, we focus on the effect of any non-simultaneity of multi-frequency observations on dispersive delay estimation and removal. Interstellar density variations combined with changes in the line of sight from pulsar and observer motions cause dispersion measure (DM) variations with an approximately power-law power spectrum, augmented in some cases by linear trends. We simulate time series, estimate the magnitude and statistical properties of timing errors that result from non-simultaneous observations, and derive prescriptions for data acquisition that are needed in order to achieve a specified timing precision. For nearby, highly stable pulsars, measurements need to be simultaneous to within about one day in order for the timing error from asynchronous DM correction to be less than about 10 ns. We discuss how timing precision improves when increasing the number of dual-frequency observations used in DM estimation for a given epoch. For a Kolmogorov wavenumber spectrum, we find about a factor of two improvement in precision timing when increasing from two to three observations but diminishing returns thereafter.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of solar surface magnetic fields on the time–distance analysis of solar subsurface meridional flows

The solar meridional flow in the deep convection zone can be measured with time–distance analysis. The difference between northward and southward acoustic wave travel times relates to the speed of meridional flow in the solar convection zone. We study the effects of surface magnetic field on the measured travel time difference in time–distance analysis by comparing the results using data with and without removing surface magnetic regions. Two results are significantly different if the field strength threshold used to remove magnetic regions is small enough, such as 50 G. The difference represents the surface magnetic effects. This difference strongly correlates with the sunspot number. The range of travel distance in this study is 7°–75°, corresponding to a depth range of 0.54−0.96 R{sub ⊙}. The difference depends on the travel time distance, and is greatest for the travel distance of 11{sup ∘}−20{sup ∘}. The study with different field strength thresholds indicates that a threshold of about 50 G can remove most surface magnetic effects. The measured surface magnetic effects can be explained by an effective downflow inside magnetic regions. These signals are not related to the large-scale meridional flow; they need to be considered in the measured travel time difference even when activity is low, if the travel time difference is used to infer meridional flow signals.

79 ASTRONOMY AND ASTROPHYSICS↗

The discrete-continuum connection in dislocation dynamics: I. Time coarse graining of cross slip

A recent continuum dislocation dynamics formalism (Xia and El-Azab 2015 Model. Simul. Mater. Sci. Eng. 23 055009) has been enriched by incorporating an improved cross slip model. 3D discrete dislocation dynamics simulations were used to collect cross slip rate data in the form of time series that were analysed to estimate the correlation time for cross slip, which was subsequently used as a time scale for local window averaging of the collected cross slip rate data. This time averaging filters out the cross slip rate fluctuations over time intervals less than the correlation time, thus resulting in relatively smoother time series for the cross slip rates. The coarse grained series were further cast in the form of smooth trends with superposed fluctuations and implemented in continuum dislocation dynamics simulations using a Monte Carlo scheme. Here, this approach resulted in a significant improvement of the predicted stress–strain response and a more realistic dislocation cell structure evolution. The similitude law for the average cell size evolution with inverse of stress, however, remains unaffected by the cross slip rates used in continuum dislocation dynamics.

36 MATERIALS SCIENCE↗

Watching proteins function with time-resolved x-ray crystallography

Macromolecular crystallography was immensely successful in the last two decades. To a large degree this success resulted from use of powerful third generation synchrotron x-ray sources. An expansive database of more than 100 000 protein structures, of which many were determined at resolution better than 2 Å, is available today. With this achievement, the spotlight in structural biology is shifting from determination of static structures to elucidating dynamic aspects of protein function. A powerful tool for addressing these aspects is time-resolved crystallography, where a genuine biological function is triggered in the crystal with a goal of capturing molecules in action and determining protein kinetics and structures of intermediates (Schmidt et al 2005a Methods Mol. Biol. 305 115–54, Schmidt 2008 Ultrashort Laser Pulses in Biology and Medicine (Berlin: Springer) pp 201–41, Neutze and Moffat 2012 Curr. Opin. Struct. Biol. 22 651–9, Šrajer 2014 The Future of Dynamic Structural Science (Berlin: Springer) pp 237–51). In this approach, short and intense x-ray pulses are used to probe intermediates in real time and at room temperature, in an ongoing reaction that is initiated synchronously and rapidly in the crystal. Time-resolved macromolecular crystallography with 100 ps time resolution at synchrotron x-ray sources is in its mature phase today, particularly for studies of reversible, light-initiated reactions. The advent of the new free electron lasers for hard x-rays (XFELs; 5–20 keV), which provide exceptionally intense, femtosecond x-ray pulses, marks a new frontier for time-resolved crystallography. The exploration of ultra-fast events becomes possible in high-resolution structural detail, on sub-picosecond time scales (Tenboer et al 2014 Science 346 1242–6, Barends et al 2015 Science 350 445–50, Pande et al 2016 Science 352 725–9). We review here state-of-the-art time-resolved crystallographic experiments both at synchrotrons and XFELs. We also outline challenges and further developments necessary to broaden the application of these methods to many important proteins and enzymes of biomedical relevance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time observation of toroidal current redistributions induced by three-dimensional MHD phenomena triggering vertical displacement events in tokamak plasmas

Three-dimensional MHD instabilities, including edge-localized modes (ELMs) and internal reconnection events (IREs), have been observed to precipitate loss of vertical stability in tokamak plasmas, resulting in vertical displacement events (VDEs). This vertical destabilization can occur due to toroidal current redistributions and/or shape changes resulting from these phenomena. Using a recently introduced method for rapidly reconstructing the two-dimensional toroidal plasma current density profile in real-time, results are presented that demonstrate the specific current distribution changes that occur during ELMs (on KSTAR) and IREs (on MAST-U) that lead to loss of vertical control. The method most efficiently reconstructs the toroidal current density profile by doing so on a basis of principal components of historical profiles. These principal components isolate dominant current profile dynamics, improving interpretability, increasing speed, and reducing dimensionality of the profile computation. On KSTAR, this computation is executed in the real-time plasma control system at a rate of 10 kHz (limited by available CPU cycle times), allowing the current profile evolution to be assessed at several times over the course of each ELM event. Further, by incorporating the reconstructions into a novel vertical stability metric, the contribution of specific current profile dynamics to the loss of vertical stability can be assessed in real-time for VDE avoidance and improved understanding of the causal relationship between three-dimensional MHD phenomena and VDEs. The success of this method in approximating toroidal current density profiles from kinetic equilibrium reconstructions is also presented ($R^2=0.990$), along with its capability to produce other equilibrium quantities of interest in real-time at high time resolution.

edge-localized modes↗