NASA TECHNICAL STANDARD, NASA-STD-7012A, LEAK TEST REQUIREMENTS
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Two people may analyze a visual scene in two completely different ways. Our study sought to determine whether human gaze may be used to establish the identity of an individual. To accomplish this objective we investigated the gaze pattern of twelve individuals viewing different still images with different spatial relationships. Specifically, we created 5 visual dot-pattern tests to be shown on a standard computer monitor. These tests challenged the viewer s capacity to distinguish proximity, alignment, and perceptual organization. Each test included 50 images of varying difficulty (total of 250 images). Eye-tracking data were collected from each individual while taking the tests. The eye-tracking data were converted into gaze velocities and analyzed with Hidden Markov Models to develop personalized gaze profiles. Using leave-one-out cross-validation, we observed that these personalized profiles could differentiate among the 12 users with classification accuracy ranging between 53% and 76%, depending on the test. This was statistically significantly better than random guessing (i.e., 8.3% or 1 out of 12). Classification accuracy was higher for the tests where the users average gaze velocity per case was lower. The study findings support the feasibility of using gaze as a biometric or personalized biomarker. These findings could have implications in Radiology training and the development of personalized e-learning environments.
Explore the source record for details and available documents.
A program for predicting the sound levels inside propeller driven aircraft arising from sidewall transmission of airborne exterior noise is validated through comparisons of predictions with both scale-model test results and measurements obtained in flight tests on a turboprop aircraft. The program produced unbiased predictions for the case of the scale-model tests, with a standard deviation of errors of about 4 dB. For the case of the flight tests, the predictions revealed a bias of 2.62-4.28 dB (depending upon whether or not the data for the fourth harmonic were included) and the standard deviation of the errors ranged between 2.43 and 4.12 dB. The analytical model is shown to be capable of taking changes in the flight environment into account.
This report discusses the relation between the temperature of the air at the entrance to the carburetor and the power developed by the engine. Its scope is limited to a consideration of the range of temperatures likely to result from changes of season, locality, or altitude, since its primary aim is the finding of a satisfactory basis for correcting power measurements to a standard temperature. The tests upon which this report is based were made upon aviation engines in the Altitude Laboratory of the Bureau of Standards. From the results of over 1,600 tests it is concluded that if calculations be based on the assumption that the indicated horsepower of an engine varies inversely as the square root of the absolute temperature of the carburetor air the values obtained will check closely experimental measurements. The extent to which this relationship would be expected from theoretical considerations is discussed and some suggestions are given relative to the use of this relationship in correcting horsepower measurements. (author)
One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980’s. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: 1) to verify natural circulation as a reliable means to safely remove decay heat, 2) to extend passive safety experience to a large-size LMR and obtain data for validating design analysis computer codes, and 3) to develop and test passive safety enhancements that might be used for future LMRs. These tests were designed to provide data sufficient to allow separation of fuel temperature effects from structural temperature effects. The data developed through this testing program were used to verify the predictive capability of passive safety analysis methods as well as provide a data base for calibrating design tools such as the SASSYS/SAS4A codes. These tests were instrumental in improving understanding of reactivity feedback mechanisms in LMRs and demonstrating passive safety margins available in an LMR. Knowledge preservation at the FFTF is focused on the areas of design, construction, startup, and operation of the reactor. This information may be of potential use for international exchanges with other LMR programs around the world. This information provides the basis for creating benchmarks for validating and testing large scale computer programs. All information preserved to date is now being stored and categorized consistent with the IAEA international standardized taxonomy. The test results information exists in several different formats depending upon the final stage of the test evaluation. Over 100 documents relevant to passive safety testing have been identified and are being recovered, scanned, and catalogued. Attempts to recover plant data tapes are also in progress. Documents related to passive safety testing are now being categorized consistent with internationally agreed upon IAEA standards. Documents are being converted to electronic format compatible with a general search engine being developed by INL. The data from the FFTF passive safety tests provides experimental verification of structural reactivity effects that should be very useful to innovative designers seeking to optimize passive safety in the design of new LMRs.
The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. In an effort to improve net heat input predictions, numerous tasks have been performed which provided a more accurate value for net heat input into the ASCs, including testing validation hardware, known as the Thermal Standard, to provide a direct comparison to numerical and empirical models used to predict convertor net heat input. This validation hardware provided a comparison for scrutinizing and improving empirical correlations and numerical models of ASC-E2 net heat input. This hardware simulated the characteristics of an ASC-E2 convertor in both an operating and non-operating mode. This paper describes the Thermal Standard testing and the conclusions of the validation effort applied to the empirical correlation methods used by the Radioisotope Power System (RPS) team at NASA Glenn.
Small-scale safety testing, while successful in screening out extremely dangerous explosive compositions, does not fully characterize the explosive hazards associated with handling larger, consolidated or bare charges. It is proposed that intermediate-scale tests using consolidated charges in the range 25 mg – 1 kg are warranted to satisfactorily address the hazards. A standard for this intermediate-scale testing should be developed, proofed, peer-reviewed and adopted to assist in the development of safe new high explosive compositions across the complex. This whitepaper explains why current small-scale safety testing is insufficient to characterize the handling hazard, identifies the guiding aspects of explosive response that drive the handling hazards associated with larger consolidated charges, and proposes a suite of tests/experiments that can serve as a starting point for an intermediate-scale safety standard.
A standard method in unconventional oil and gas production is the process of hydraulic fracturing followed by a shut-in period, during which the fracture fluid remains pressurized in the reservoir for up to three weeks before production begins. Despite this widely used process, very little is known about what occurs in the reservoir during this shut-in process. In order to properly delineate potential reservoir reactions that may occur during shut-in that would lead to corrosion and scaling events, experiments were conducted in high pressure, high temperature reactors to simulate conditions of the Wolfcamp Formation in the Delaware Basin. Experimental design allowed the assessment of the effect of proppant, microbiology, and time on the mineralogy and fluid chemistry in the reservoir. Results suggest the biggest impact on fluid chemistry and shale mineralogy during shut-in is time. Analyses demonstrate dissolution of the shale material, with maximum dissolved ions occurring after 7 days of the shut-in period. After 21 days, results suggest precipitation occurs. The Delaware Basin is demonstrated to be high in sulfate content, which further increases in the fluid due to dissolution reactions during shut-in. The pressure vessel experiments suggest there was no significant contribution to reactions from microbiology during the shut-in period. Furthermore, early production samples demonstrate a significant selection of the microorganism Caminicella, a genus of which has previously been correlated to corrosion and sulfide production. Results suggest shut-in conditions may provide high sulfate concentrations that could later be utilized by a shifted microbial community to drive potential well infrastructure failure. This is the first study to incorporate microbiology, mineralogy, and fluid chemistry to investigate the fundamental geochemical reactions that occur during shut-in and early phase production of the Delaware Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S032R001/2477425/urtec-2021-5219-ms.pdf/1 by Carol Worster on 28 February 2022 Basin. Results from this study can complement observations from the Hydraulic Fracture Test Site 2 observations
The minimum weight optimization of structural systems, subject to strength and displacement constraints as well as size side constraints, was investigated by the Simultaneous ANalysis and Design (SAND) approach. As an optimizer, the code NPSOL was used which is based on a sequential quadratic programming (SQP) algorithm. The structures were modeled by the finite element method. The finite element related input to NPSOL was automatically generated from the input decks of such standard FEM/optimization codes as NASTRAN or ASTROS, with the stiffness matrices, at present, extracted from the FEM code ANALYZE. In order to avoid ill-conditioned matrices that can be encountered when the global stiffness equations are used as additional nonlinear equality constraints in the SAND approach (with the displacements as additional variables), the matrix displacement method was applied. In this approach, the element stiffness equations are used as constraints instead of the global stiffness equations, in conjunction with the nodal force equilibrium equations. This approach adds the element forces as variables to the system. Since, for complex structures and the associated large and very sparce matrices, the execution times of the optimization code became excessive due to the large number of required constraint gradient evaluations, the Kreisselmeier-Steinhauser function approach was used to decrease the computational effort by reducing the nonlinear equality constraint system to essentially a single combined constraint equation. As the linear equality and inequality constraints require much less computational effort to evaluate, they were kept in their previous form to limit the complexity of the KS function evaluation. To date, the standard three-bar, ten-bar, and 72-bar trusses have been tested. For the standard SAND approach, correct results were obtained for all three trusses although convergence became slower for the 72-bar truss. When the matrix displacement method was used, correct results were still obtained, but the execution times became excessive due to the large number of constraint gradient evaluations required. Using the KS function, the computational effort dropped, but the optimization seemed to become less robust. The investigation of this phenomenon is continuing. As an alternate approach, the code MINOS for the optimization of sparse matrices can be applied to the problem in lieu of the Kreisselmeier-Steinhauser function. This investigation is underway.
The bypass flow in a prismatic high temperature gas-cooled reactor (HTGR) is the flow that occurs between adjacent graphite blocks. Gaps exist between blocks due to variances in their manufacture and installation and because of the expansion and shrinkage of the blocks from heating and irradiation. Although the temperature of fuel compacts and graphite is sensitive to the presence of bypass flow, there is great uncertainty in the level and effects of the bypass flow. The Next Generation Nuclear Plant (NGNP) program at the Idaho National Laboratory has undertaken to produce experimental data of isothermal bypass flow between three adjacent graphite blocks. These data are intended to provide validation for computational fluid dynamic (CFD) analyses of the bypass flow. Such validation data sets are called Standard Problems in the nuclear safety analysis field. Details of the experimental apparatus as well as several pre-test calculations of the bypass flow are provided. Pre-test calculations are useful in examining the nature of the flow and to see if there are any problems associated with the flow and its measurement. The apparatus is designed to be able to provide three different gap widths in the vertical direction (the direction of the normal coolant flow) and two gap widths in the horizontal direction. It is expected that the vertical bypass flow will range from laminar to transitional to turbulent flow for the different gap widths that will be available.
This document is a handout guide to the standard thermal insulation systems testing capabilities of the Cryogenics Test Laboratory at NASA Kennedy Space Center.
This report is provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-Band and L-Band Communications Standard Development and was based on direction provided by FAA project-level agreements for New ATM Requirements-Future Communications. Task 7 included two subtasks. Subtask 7-1 addressed C-band (5091- to 5150-MHz) airport surface data communications standards development, systems engineering, test bed and prototype development, and tests and demonstrations to establish operational capability for the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2 focused on systems engineering and development support of the L-band digital aeronautical communications system (L-DACS). Subtask 7-1 consisted of two phases. Phase I included development of AeroMACS concepts of use, requirements, architecture, and initial high-level safety risk assessment. Phase II builds on Phase I results and is presented in two volumes. Volume I is devoted to concepts of use, system requirements, and architecture, including AeroMACS design considerations. Volume II (this document) describes an AeroMACS prototype evaluation and presents final AeroMACS recommendations. This report also describes airport categorization and channelization methodologies. The purposes of the airport categorization task were (1) to facilitate initial AeroMACS architecture designs and enable budgetary projections by creating a set of airport categories based on common airport characteristics and design objectives, and (2) to offer high-level guidance to potential AeroMACS technology and policy development sponsors and service providers. A channelization plan methodology was developed because a common global methodology is needed to assure seamless interoperability among diverse AeroMACS services potentially supplied by multiple service providers.
Le Chatelier in 1887 and Powers in 1947 demonstrated that the volume of nanoscale C-S-H (calcium silicate hydrate) particles formed during hydration is smaller than the combined volume of the reactants—the anhydrous Portland cement and water. Hydration has thus been considered as contractive. An experiment shows that the opposite is true above the nanoscale. The porous skeleton of cement paste expands as the growing C-S-H particles push each other apart, similar to crystal growth pressure. This is significant for high-performance concretes (HPC) with low water-cement ratios (w/c ≤ 0.4), where chemical self-desiccation lowers pore relative humidity by 40%, compared to just 1% in traditional concretes (w/c ≈ 0.5). Standard American Society for Testing and Materials (ASTM) C1608 tests, using 10 mm thick water-immersed specimens, show large shrinkage because the half-time of water ingress is many decades, unable to offset shrinkage-causing self-desiccation. The present experiment, using a laser microscopy-topography technique, proves the opposite—expansion, evidenced by measuring the length changes of water-immersed HPC shards 0.5 mm thick in which the diffusion halftime, only about one hour, allows continuous resaturation of pores, canceling self-desiccation. The faster diffusion (halftime of one hour) enables continuous pore resaturation, preventing shrinkage. When sealed with paraffin oil, the shards self-desiccate and shrink. These findings align with studies since 2015, showing that models excluding hydration expansion cannot fit test data across various specimen sizes and sealing conditions. The results suggest that standardized ASTM tests for the so-called chemical shrinkage in modern concretes with very low water-cement ratios are misleading and need revision.
Introduction: Despite the proven effectiveness of immunization in preventing morbidity and mortality, adult vaccines remain underutilized. The objective of this study was to describe clinicians’ and pharmacists’ self-reported implementation of the Standards for Adult Immunization Practice (“the Standards”; i.e., routine assessment, recommendation, and administration/referral for needed vaccines, and documentation of administered vaccines, including in immunization information systems). Methods: Two Internet panel surveys (one among clinicians and one among pharmacists) were conducted during February–March 2017 and asked respondents about their practice’s implementation of the Standards. T-tests assessed associations between clinician medical specialty, vaccine type, and each component of the Standards (March–August 2017). Results: Implementation of the Standards varied substantially by vaccine and provider type. For example, >80.0% of providers, including obstetrician/gynecologists and subspecialists, assessed for and recommended influenza vaccine. However, 24.3% of obstetrician/gynecologists and 48.9% of subspecialists did not stock influenza vaccine for administration. Although zoster vaccine was recommended by >89.0% of primary care providers, <58.0% stocked the vaccine; by contrast, 91.6% of pharmacists stocked zoster vaccine. Vaccine needs assessments, recommendations, and stocking/referrals also varied by provider type for pneumococcal; tetanus, diphtheria, acellular pertussis; tetanus diphtheria; human papillomavirus; and hepatitis B vaccines. Conclusions: This report highlights gaps in access to vaccines recommended for adults across the spectrum of provider specialties. Greater implementation of the Standards by all providers could improve adult vaccination rates in the U.S. by reducing missed opportunities to recommend vaccinations and either vaccinate or refer patients to vaccine providers.
Explosive compositions loaded with various metal particulates were produced and tested using a unique experimental configuration. The high explosive HMX was used as the standard and was tested over a range of mass loading fractions using tungsten and tantalum as metal additives. The diagnostics used in this set of experiments included free-field blast sensors, dynamic force sensors, time-of-arrival sensors, and a high-speed digital camera. The experimental arrangement allowed for concurrent spatial measurements of the static pressure from expanding gaseous detonation products, along with the total force from the combination of gaseous products and solid particles. The total pressure from the multi-phase products was calculated by measuring the total force applied to the surface of a newly developed force sensor. The results from the force sensor and other measurement techniques were validated against existing numerical methods. The relationship between static and dynamic pressures as a function of metal loading fraction was examined empirically at several distances from the charge for two distinct metal additives.
Astronauts and cosmonauts may experience symptoms of orthostatic intolerance during re-entry, landing, and for several days post-landing following short- and long-duration spaceflight. Presyncopal symptoms have been documented in approximately 20% of short-duration and greater than 60% of long-duration flyers on landing day specifically during 5-10 min of controlled (no countermeasures employed at the time of testing) stand tests or 80 deg head-up tilt tests. Current operational countermeasures to orthostatic intolerance include fluid loading prior to and whole body cooling during re-entry as well as compression garments that are worn during and for up to several days after landing. While both NASA and the Russian space program have utilized compression garments to protect astronauts and cosmonauts traveling on their respective vehicles, a "next-generation" gradient compression garment (GCG) has been developed and tested in collaboration with a commercial partner to support future space flight missions. Unlike previous compression garments used operationally by NASA that provide a single level of compression across only the calves, thighs, and lower abdomen, the GCG provides continuous coverage from the feet to below the pectoral muscles in a gradient fashion (from approximately 55 mm Hg at the feet to approximately 16 mmHg across the abdomen). The efficacy of the GCG has been demonstrated previously after a 14-d bed rest study without other countermeasures and after short-duration Space Shuttle missions. Currently the GCG is being tested during a stand test following long-duration missions (~6 months) to the International Space Station. While results to date have been promising, interactions of the GCG with other space suit components have not been examined. Specifically, it is unknown whether wearing the GCG over NASA's Maximum Absorbency Garment (MAG; absorbent briefs worn for the collection of urine and feces while suited during re-entry and landing) will interfere with the effectiveness of the GCG or conversely whether the GCG will reduce the fluid absorption capabilities of the MAG. Methods: This operational, directed study, will (1) determine whether the effectiveness of the GCG is affected by the MAG with regard to cardiovascular responses to head-up tilt, the standard orthostatic intolerance test employed for astronauts and bed rest subjects; (2) determine whether the effectiveness of the MAG is compromised by the GCG tested by injecting a standard fluid volume (950 ml in 3 separate simulated "urine voids") at a standardized rate (30 ml/sec); and (3) determine whether comfort is affected by wearing the MAG under the GCG using a standardized questionnaire. Results from this study will guide future development and operational use of the GCG and MAG to maximize crew health, safety, and comfort.