Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Evaluation of Rectal Dose During High-Dose-Rate Intracavitary Brachytherapy for Cervical Carcinoma

High-dose-rate intracavitary brachytherapy (HDR-ICBT) for carcinoma of the uterine cervix often results in high doses being delivered to surrounding organs at risk (OARs) such as the rectum and bladder. Therefore, it is important to accurately determine and closely monitor the dose delivered to these OARs. In this study, we measured the dose delivered to the rectum by intracavitary applications and compared this measured dose to the International Commission on Radiation Units and Measurements rectal reference point dose calculated by the treatment planning system (TPS). To measure the dose, we inserted a miniature (0.1 cm{sup 3}) ionization chamber into the rectum of 86 patients undergoing radiation therapy for cervical carcinoma. The response of the miniature chamber modified by 3 thin lead marker rings for identification purposes during imaging was also characterized. The difference between the TPS-calculated maximum dose and the measured dose was <5% in 52 patients, 5-10% in 26 patients, and 10-14% in 8 patients. The TPS-calculated maximum dose was typically higher than the measured dose. Our study indicates that it is possible to measure the rectal dose for cervical carcinoma patients undergoing HDR-ICBT. We also conclude that the dose delivered to the rectum can be reasonably predicted by the TPS-calculated dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-459: Dosimetric Consequences of Rotated Elliptical Proton Spots in Modeling In-Air Proton Fluence for Calculating Doses in Water of Proton Pencil Beams

Purpose: We present a study of dosimetric consequences on doses in water in modeling in-air proton fluence independently along principle axes for rotated elliptical spots. Methods: Phase-space parameters for modeling in-air fluence are the position sigma for the spatial distribution, the angle sigma for the angular distribution, and the correlation between position and angle distributions. Proton spots of the McLaren proton therapy system were measured at five locations near the isocenter for the energies of 180 MeV and 250 MeV. An elongated elliptical spot rotated with respect to the principle axes was observed for the 180 MeV, while a circular-like spot was observed for the 250 MeV. In the first approach, the phase-space parameters were derived in the principle axes without rotation. In the second approach, the phase space parameters were derived in the reference frame with axes rotated to coincide with the major axes of the elliptical spot. Monte-Carlo simulations with derived phase-space parameters using both approaches to tally doses in water were performed and analyzed. Results: For the rotated elliptical 180 MeV spots, the position sigmas were 3.6 mm and 3.2 mm in principle axes, but were 4.3 mm and 2.0 mm when the reference frame was rotated. Measured spots fitted poorly the uncorrelated 2D Gaussian, but the quality of fit was significantly improved after the reference frame was rotated. As a Result, phase space parameters in the rotated frame were more appropriate for modeling in-air proton fluence of 180 MeV protons. Considerable differences were observed in Monte Carlo simulated dose distributions in water with phase-space parameters obtained with the two approaches. Conclusion: For rotated elliptical proton spots, phase-space parameters obtained in the rotated reference frame are better for modeling in-air proton fluence, and can be introduced into treatment planning systems.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-378: Evaluation of An Analytical Model for the Inter-Seed Attenuation Effect in 103-Pd Multi-Seed Implant Brachytherapy

Purpose: Brachytherapy treatment planning systems based on TG-43 protocol calculate the dose in water and neglects the heterogeneity effect of seeds in multi-seed implant brachytherapy. In this research, the accuracy of a novel analytical model that we propose for the inter-seed attenuation effect (ISA) for 103-Pd seed model is evaluated. Methods: In the analytical model, dose perturbation due to the ISA effect for each seed in an LDR multi-seed implant for 103-Pd is calculated by assuming that the seed of interest is active and the other surrounding seeds are inactive. The cumulative dosimetric effect of all seeds is then summed using the superposition principle. The model is based on pre Monte Carlo (MC) simulated 3D kernels of the dose perturbations caused by the ISA effect. The cumulative ISA effect due to multiple surrounding seeds is obtained by a simple multiplication of the individual ISA effect by each seed, the effect of which is determined by the distance from the seed of interest. This novel algorithm is then compared with full MC water-based simulations (FMCW). Results: The results show that the dose perturbation model we propose is in excellent agreement with the FMCW values for a case with three seeds separated by 1 cm. The average difference of the model and the FMCW simulations was less than 8%±2%. Conclusion: Using the proposed novel analytical ISA effect model, one could expedite the corrections due to the ISA dose perturbation effects during permanent seed 103-Pd brachytherapy planning with minimal increase in time since the model is based on multiplications and superposition. This model can be applied, in principle, to any other brachytherapy seeds. Further work is necessary to validate this model on a more complicated geometry as well.

60 APPLIED LIFE SCIENCES↗

Endocavitary in vivo Dosimetry for IMRT Treatments of Gynecologic Tumors

The accuracy and reproducibility of endometrial carcinoma treatment with intensity-modulated radiotherapy (IMRT) was assessed by means of in vivo dosimetry. Six patients who had previously undergone radical hysterectomy for endometrial carcinoma were treated with IMRT using a vaginal applicator with radio-opaque fiducial markers. An ion-chamber inserted into the applicator supplied an endocavitary in vivo dosimetry for quality assurance purposes. The ratio R = D/D{sub TPS} between the in vivo measured dose D and the predicted dose by the treatment planning system D{sub TPS} was determined for every fraction of the treatment. Results showed that 90% and 100% of the ratios resulted equal to 1 within 5% and 10%, respectively. The mean value of the ratios distribution for the 6 patients was R = 0.995 and the SD = 0.034. The ratio R* between the measured and predicted total doses for each patient was near to 1, within 2%. The dosimetric results suggest that the use of a vaginal applicator in an image-guided approach could make the interfractions target position stable and reproducible, allowing a safe use of the IMRT technique in the treatment of postoperative vaginal vault. In vivo dosimetry may supply useful information about the discrimination of random vs. systematic errors. The workload is minimum and this in vivo dosimetry can be applied also in the clinical routine.

61 RADIATION PROTECTION AND DOSIMETRY↗

Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P<.001; r = 0.44, P=.03, respectively) and the medial and central contralateral breast (r = 0.73, P<.001; r = 0.88, P<.001, respectively). With 3D-CRT there was a significant correlation in the medial and lateral ipsilateral breast (r = 0.45, P=.03; r = 0.68, P<.001, respectively); the medial and central contralateral breast (r = 0.62, P=.001; r = 0.86, P<.001, respectively); and the mid neck (r = 0.42, P=.04, respectively). On average, HT-calculated dose overestimated the measured dose by 14%; 3D-CRT underestimated the dose by 0.4%. There was a borderline association between highest measured skin dose and moist desquamation (P=.05). Skin-sparing HT had greater skin homogeneity (homogeneity index of 1.39 vs 1.65, respectively; P=.005) than 3D-CRT plans. HT plans had a lower skin{sub V50} (1.4% vs 5.9%, respectively; P=.001) but higher skin{sub V40} and skin{sub V30} (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients receiving adjuvant breast RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-SPS-05: Experimental Validation of Peripheral Dose Distribution of Electron Beams for Eclipse Electron Monte Carlo Algorithm

Purpose: In this study, the two available calculation algorithms of the Varian Eclipse treatment planning system(TPS), the electron Monte Carlo(eMC) and General Gaussian Pencil Beam(GGPB) algorithms were used to compare measured and calculated peripheral dose distribution of electron beams. Methods: Peripheral dose measurements were carried out for 6, 9, 12, 15, 18 and 22 MeV electron beams of Varian Triology machine using parallel plate ionization chamber and EBT3 films in the slab phantom. Measurements were performed for 6×6, 10×10 and 25×25cm{sup 2} cone sizes at dmax of each energy up to 20cm beyond the field edges. Using the same film batch, the net OD to dose calibration curve was obtained for each energy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution measured using parallel plate ionization chamber and EBT3 film and calculated by eMC and GGPB algorithms were compared. The measured and calculated data were then compared to find which algorithm calculates peripheral dose distribution more accurately. Results: The agreement between measurement and eMC was better than GGPB. The TPS underestimated the out of field doses. The difference between measured and calculated doses increase with the cone size. The largest deviation between calculated and parallel plate ionization chamber measured dose is less than 4.93% for eMC, but it can increase up to 7.51% for GGPB. For film measurement, the minimum gamma analysis passing rates between measured and calculated dose distributions were 98.2% and 92.7% for eMC and GGPB respectively for all field sizes and energies. Conclusion: Our results show that the Monte Carlo algorithm for electron planning in Eclipse is more accurate than previous algorithms for peripheral dose distributions. It must be emphasized that the use of GGPB for planning large field treatments with 6 MeV could lead to inaccuracies of clinical significance.

60 APPLIED LIFE SCIENCES↗

Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source--SmartSeed: Dosimetric impact of fluorescence x rays

Purpose: The detailed study of a new permanent iodine-125 brachytherapy source, SmartSeed, is presented in this article. It is the first iodine seed made with biocompatible polymer and is manufactured by the IBt-Bebig group. Methods: Three dosimetric studies have been performed: The first one used thermoluminescent detectors in a solid water phantom with NIST (National Institute of Standards and Technology, USA) calibrated seeds, and two separate studies were of Monte Carlo photon transport calculations (MCNP5 code). The TG-43U1 protocol was applied to derive dosimetric parameters for clinical applications. Results: The radial dose function g(r) was determined at different distances ranging from 0.5 to 10 cm; and the anisotropy function F(r,{theta}) at angles ranging from 0 deg. to 350 deg. in 10 deg. increments. Monte Carlo calculations were performed in liquid water to obtain values for {Lambda}, g(r), F(r,{theta}), and {phi}{sub an}(r) as recommended by the TG-43U1 protocol for use in treatment planning system software. SmartSeed's biocompatible polymer capsule permits fluorescence x rays (3, 5, and 12 keV), generated by lead glass marker, to be present in the emission spectrum, influencing the dose rate constant. The impact on near field dosimetry in water from these x rays was also investigated and reported. The capsule also attenuates iodine-125 energies much less than typical titanium encased sources, resulting in a highly isotropic source. Conclusions: SmartSeed has a dose rate constant of 0.895{+-}7.3% cGy h{sup -1} U{sup -1}, a radial dose function nearly identical to the IBt-Bebig model I25.S06 seed, and a highly isotropic dose distribution. Fluorescence x rays account for the relatively low value of {Lambda}, yet their variable contribution to dosimetry arising from seed dimensional uncertainties is estimated to be <0.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Glass Property Models and Constraints for Estimating the Glass to be Produced at Hanford by Implementing Current Advanced Glass Formulation Efforts

Recent glass formulation and melter testing data have suggested that significant increases in waste loading in HLW and LAW glasses are possible over current system planning estimates. The data (although limited in some cases) were evaluated to determine a set of constraints and models that could be used to estimate the maximum loading of specific waste compositions in glass. It is recommended that these models and constraints be used to estimate the likely HLW and LAW glass volumes that would result if the current glass formulation studies are successfully completed. It is recognized that some of the models are preliminary in nature and will change in the coming years. Plus the models do not currently address the prediction uncertainties that would be needed before they could be used in plant operations. The models and constraints are only meant to give an indication of rough glass volumes and are not intended to be used in plant operation or waste form qualification activities. A current research program is in place to develop the data, models, and uncertainty descriptions for that purpose. A fundamental tenet underlying the research reported in this document is to try to be less conservative than previous studies when developing constraints for estimating the glass to be produced by implementing current advanced glass formulation efforts. The less conservative approach documented herein should allow for the estimate of glass masses that may be realized if the current efforts in advanced glass formulations are completed over the coming years and are as successful as early indications suggest they may be. Because of this approach there is an unquantifiable uncertainty in the ultimate glass volume projections due to model prediction uncertainties that has to be considered along with other system uncertainties such as waste compositions and amounts to be immobilized, split factors between LAW and HLW, etc.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-247: Multi-Leaf Collimator Model Adjustments Improve Small Field Dosimetry in VMAT Plans

Purpose: The Elekta beam modulator linac employs a 4-mm micro multileaf collimator (MLC) backed by a fixed jaw. Out-of-field dose discrepancies between treatment planning system (TPS) calculations and output water phantom measurements are caused by the 1-mm leaf gap required for all moving MLCs in a VMAT arc. In this study, MLC parameters are optimized to improve TPS out-of-field dose approximations. Methods: Static 2.4 cm square fields were created with a 1-mm leaf gap for MLCs that would normally park behind the jaw. Doses in the open field and leaf gap were measured with an A16 micro ion chamber and EDR2 film for comparison with corresponding point doses in the Pinnacle TPS. The MLC offset table and tip radius were adjusted until TPS point doses agreed with photon measurements. Improvements to the beam models were tested using static arcs consisting of square fields ranging from 1.6 to 14.0 cm, with 45° collimator rotation, and 1-mm leaf gap to replicate VMAT conditions. Gamma values for the 3-mm distance, 3% dose difference criteria were evaluated using standard QA procedures with a cylindrical detector array. Results: The best agreement in point doses within the leaf gap and open field was achieved by offsetting the default rounded leaf end table by 0.1 cm and adjusting the leaf tip radius to 13 cm. Improvements in TPS models for 6 and 10 MV photon beams were more significant for smaller field sizes 3.6 cm or less where the initial gamma factors progressively increased as field size decreased, i.e. for a 1.6cm field size, the Gamma increased from 56.1% to 98.8%. Conclusion: The MLC optimization techniques developed will achieve greater dosimetric accuracy in small field VMAT treatment plans for fixed jaw linear accelerators. Accurate predictions of dose to organs at risk may reduce adverse effects of radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-431: Vertically-Oriented Farmer-Type Chamber for Small-Field Applications

Purpose: To introduce a non-conventional measurement setup using Farmer-type chambers to accommodate several situations of small-field dose measurements without compromising accuracy. The validation of this technique was demonstrated for photon small-field output measurements, and electron small-field percentage depth-dose (PDD) measurements. Methods: Initial chamber alignment was performed using the conventional (horizontally-oriented) chamber setup. A PDD was acquired for a 4×4 cm{sup 2} field size using this arrangement. This PDD was used as a positional reference for the vertically-oriented chamber (VOC) configuration. Next, a PDD was acquired for a 4×4 cm{sup 2} field size with the VOC. The PDD's were superimposed to find the effective shift of the VOC. Using the shifted VOC setup, photon small-field output factors were measured and compared to stereotactic diode output factor measurements. Additionally, electron smallfield PDD's were acquired using the VOC setup and results were compared to electron Monte Carlo (eMC) predictions in the Eclipse treatment planning system (TPS). Results: (1) For photon small-field output factors field-sizes 2×2 cm{sup 2} and larger, the difference between the VOC setup and SFD measurements were less than 0.8%. For field sizes less than 2×2 cm{sup 2} discrepancies ranged from 4.0 to 10.6%. (2) PDD's measured by VOC setup show better than 1.6% agreement as compared to eMC for all electron energies measured down to the 80% depth on the 2×2 cm{sup 2} PDD curve. Disagreement between the VOC setup measurement and eMC calculations for depths down to the 50% depth on the PDD curve is 3.6% or less. Conclusion: Using the VOC setup, it is possible to use a conventional farmer chamber for small field-size measurements down to 2×2 cm{sup 2} field size without sacrificing the accuracy of measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-220: Computational Accuracy of Adaptive Convolution (AC) and Collapsed Cone Convolution (CCC) Algorithms in the Presence of Air Gaps

Purpose: To compare the percentage depth dose (PDD) computational accuracy of Adaptive Convolution (AC) and Collapsed Cone Convolution (CCC) algorithms in the presence of air gaps. Methods: A 30×30×30 cm{sup 3} solid water phantom with two 5cm air gaps was scanned with a CT simulator unit and exported into the Phillips Pinnacle™ treatment planning system. PDDs were computed using the AC and CCC algorithms. Photon energy of 6 MV was used with field sizes of 3×3 cm{sup 2}, 5×5 cm{sup 2}, 10×10 cm{sup 2}, 15×15 cm{sup 2}, and 20×20 cm{sup 2}. Ionization chamber readings were taken at different depths in water for all the field sizes. The percentage differences in the PDDs were computed with normalization to the depth of maximum dose (dmax). The calculated PDDs were then compared with measured PDDs. Results: In the first buildup region, both algorithms overpredicted the dose for all field sizes and under-predicted for all other subsequent buildup regions. After dmax in the three water media, AC under-predicted the dose for field sizes 3×3 and 5×5 cm{sup 2} and overpredicted for larger field sizes, whereas CCC under-predicted for all field sizes. Upon traversing the first air gap, AC showed maximum differences of –3.9%, −1.4%, 2.0%, 2.5%, 2.9% and CCC had maximum differences of −3.9%, −3.0%,–3.1%, −2.7%, −1.8% for field sizes 3×3, 5×5, 10×10, 15×15, and 20×20 cm{sup 2} respectively. Conclusion: The effect of air gaps causes a significant difference in the PDDs computed by both the AC and CCC algorithms in secondary build-up regions. AC computed larger values for the PDDs except at smaller field sizes. For CCC, the size of the errors in prediction of the PDDs has an inverse relationship with respect to field size. These effects should be considered in treatment planning where significant air gaps are encountered.

60 APPLIED LIFE SCIENCES↗

SU-E-T-105: An FMEA Survey of Intensity Modulated Radiation Therapy (IMRT) Step and Shoot Dose Delivery Failure Modes

Purpose: To assess the perception of TG-142 tolerance level dose delivery failures in IMRT and the application of FMEA process to this specific aspect of IMRT. Methods: An online survey was distributed to medical physicists worldwide that briefly described 11 different failure modes (FMs) covered by basic quality assurance in step- and-shoot IMRT at or near TG-142 tolerance criteria levels. For each FM, respondents estimated the worst case H&N patient percent dose error and FMEA scores for Occurrence, Detectability, and Severity. Demographic data was also collected. Results: 181 individual and three group responses were submitted. 84% were from North America. Most (76%) individual respondents performed at least 80% clinical work and 92% were nationally certified. Respondent medical physics experience ranged from 2.5–45 years (average 18 years). 52% of individual respondents were at least somewhat familiar with FMEA, while 17% were not familiar. Several IMRT techniques, treatment planning systems and linear accelerator manufacturers were represented. All FMs received widely varying scores ranging from 1–10 for occurrence, at least 1–9 for detectability, and at least 1–7 for severity. Ranking FMs by RPN scores also resulted in large variability, with each FM being ranked both most risky (1st ) and least risky (11th) by different respondents. On average MLC modeling had the highest RPN scores. Individual estimated percent dose errors and severity scores positively correlated (p<0.10) for each FM as expected. No universal correlations were found between the demographic information collected and scoring, percent dose errors, or ranking. Conclusion: FMs investigated overall were evaluated as low to medium risk, with average RPNs less than 110. The ranking of 11 FMs was not agreed upon by the community. Large variability in FMEA scoring may be caused by individual interpretation and/or experience, thus reflecting the subjective nature of the FMEA tool.

60 APPLIED LIFE SCIENCES↗

Optimal field-splitting algorithm in intensity-modulated radiotherapy: Evaluations using head-and-neck and female pelvic IMRT cases

To develop an optimal field-splitting algorithm of minimal complexity and verify the algorithm using head-and-neck (H and N) and female pelvic intensity-modulated radiotherapy (IMRT) cases. An optimal field-splitting algorithm was developed in which a large intensity map (IM) was split into multiple sub-IMs (≥2). The algorithm reduced the total complexity by minimizing the monitor units (MU) delivered and segment number of each sub-IM. The algorithm was verified through comparison studies with the algorithm as used in a commercial treatment planning system. Seven IMRT, H and N, and female pelvic cancer cases (54 IMs) were analyzed by MU, segment numbers, and dose distributions. The optimal field-splitting algorithm was found to reduce both total MU and the total number of segments. We found on average a 7.9 ± 11.8% and 9.6 ± 18.2% reduction in MU and segment numbers for H and N IMRT cases with an 11.9 ± 17.4% and 11.1 ± 13.7% reduction for female pelvic cases. The overall percent (absolute) reduction in the numbers of MU and segments were found to be on average −9.7 ± 14.6% (−15 ± 25 MU) and −10.3 ± 16.3% (−3 ± 5), respectively. In addition, all dose distributions from the optimal field-splitting method showed improved dose distributions. The optimal field-splitting algorithm shows considerable improvements in both total MU and total segment number. The algorithm is expected to be beneficial for the radiotherapy treatment of large-field IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-356: Efficient Segmentation of Flattening Filter Free Photon Beamsfor 3D-Conformal SBRT Treatment Planning

Purpose: It has been argued that a 3D-conformal technique (3DCRT) is suitable for SBRT due to its simplicity for non-coplanar planning and delivery. It has also been hypothesized that a high dose delivered in a short time can enhance indirect cell death due to vascular damage as well as limiting intrafraction motion. Flattening Filter Free (FFF) photon beams are ideal for high dose rate treatment but their conical profiles are not ideal for 3DCRT. The purpose of our work is to present a method to efficiently segment an FFF beam for standard 3DCRT planning. Methods: A 10×10 cm Varian True Beam 6X FFF beam profile was analyzed using segmentation theory to determine the optimum segmentation intensity required to create an 8 cm uniform dose profile. Two segments were automatically created in sequence with a Varian Eclipse treatment planning system by converting isodoses corresponding to the calculated segmentation intensity to contours and applying the “fit and shield” tool. All segments were then added to the FFF beam to create a single merged field. Field blocking can be incorporated but was not used for clarity. Results: Calculation of the segmentation intensity using an algorithm originally proposed by Xia and Verhey indicated that each segment should extend to the 92% isodose. The original FFF beam with 100% at the isocenter at a depth of 10 cm was reduced to 80% at 4cm from the isocenter; the segmented beam had +/−2.5 % uniformity up to 4.4cm from the isocenter. An additional benefit of our method is a 50% decrease in the 80%-20% penumbra of 0.6cm compared to 1.2cm in the original FFF beam. Conclusion: Creation of two optimum segments can flatten a FFF beam and also reduce its penumbra for clinical 3DCRT SBRT treatment.

60 APPLIED LIFE SCIENCES↗

Combined Global Navigation Satellite Systems in the Space Service Volume

Besides providing position, velocity, and timing (PVT) for terrestrial users, the Global Positioning System (GPS) is also being used to provide PVT information for earth orbiting satellites. In 2006, F. H. Bauer, et. al., defined the Space Service Volume in the paper GPS in the Space Service Volume , presented at ION s 19th international Technical Meeting of the Satellite Division, and looked at GPS coverage for orbiting satellites. With GLONASS already operational, and the first satellites of the Galileo and Beidou/COMPASS constellations already in orbit, it is time to look at the use of the new Global Navigation Satellite Systems (GNSS) coming into service to provide PVT information for earth orbiting satellites. This presentation extends GPS in the Space Service Volume by examining the coverage capability of combinations of the new constellations with GPS GPS was first explored as a system for refining the position, velocity, and timing of other spacecraft equipped with GPS receivers in the early eighties. Because of this, a new GPS utility developed beyond the original purpose of providing position, velocity, and timing services for land, maritime, and aerial applications. GPS signals are now received and processed by spacecraft both above and below the GPS constellation, including signals that spill over the limb of the earth. Support of GPS space applications is now part of the system plan for GPS, and support of the Space Service Volume by other GNSS providers has been proposed to the UN International Committee on GNSS (ICG). GPS has been demonstrated to provide decimeter level position accuracy in real-time for satellites in low Earth orbit (centimeter level in non-real-time applications). GPS has been proven useful for satellites in geosynchronous orbit, and also for satellites in highly elliptical orbits. Depending on how many satellites are in view, one can keep time locked to the GNSS standard, and through that to Universal Time as long as at least one satellite is in view (the longest duration with no satellites in view is important in determining the maximum clock drift from GNSS time). Instantaneous position requires four satellites in view, but because orbital motion is predictable, it is possible to build up knowledge of the orbital position gradually through time without a need for constant four satellite coverage. However, it is desirable to have four satellite coverage when performing satellite maneuvers, since there can be significant changes in velocity, leading to large changes in orbit parameter, causing substantial divergence in position over time. The Space Service Volume has been defined as the volume between three thousand km altitude and geosynchronous altitude, and can be divided into medium orbit services between three thousand km altitude and eight thousand km altitude, and high orbit services above eight thousand km. The Terrestrial Service Volume includes the Earth s surface, the atmosphere, and space below the altitude of three thousand km. The Terrestrial Service Volume is the volume within which the GNSS systems will have very similar performance to the Earth surface, and satellites need only use the signals specified to provide terrestrial performance. Above three thousand km the use of signals passing by the Earth s limb becomes important, so it is desirable to have additional information on signal strength, phase delay, and group delay covering wider beam angles than are needed for terrestrial service (and which can be obtained by monitoring GNSS signals from the Earth s surface). This presentation will look at each of the new GNSS constellations in combination with GPS (GLONASS with GPS, Galileo with GPS, Beidou/COMPASS with GPS), and also at the combination of all four GNSS systems. The presentation will largely follow the format of GPS in the Space Service Volume , presenting data on the availability of one, two, three, or four of the various combinations of GNSS constellation satelles at approximately two thousand grid points evenly spaced and fixed in longitude and latitude, the duration of the longest single-fold outages (intervals when no satellites are available), and the duration of the longest four-fold outages (intervals when fewer than four satellites are available) at several altitudes. Following the original paper, we will use the altitudes of three hundred km (typical LEO satellite, and within the Terrestrial Service Volume), at three thousand km (border between Terrestrial Service Volume and Space Service Volume), at eight thousand km (the border between medium and high orbit service within the Space Service Volume), at fifteen thousand km (just below the GNSS constellations), at twenty five thousand km (just above the GNSS constellations), at thirty six thousand, five hundred km (limit of Space Service Volume definition, geosynchronous altitude), and at seventy thousand km (to show the potential usefulness of GNSS beyond geosynchronous altitude).

Force, Dale A.↗

SU-F-T-315: Comparative Studies of Planar Dose with Different Spatial Resolution for Head and Neck IMRT QA

Purpose: To quantitatively investigate the planar dose difference and the γ value between the reference fluence map with the 1 mm detector-to-detector distance and the other fluence maps with less spatial resolution for head and neck intensity modulated radiation (IMRT) therapy. Methods: For ten head and neck cancer patients, the IMRT quality assurance (QA) beams were generated using by the commercial radiation treatment planning system, Pinnacle3 (ver. 8.0.d Philips Medical System, Madison, WI). For each beam, ten fluence maps (detector-to-detector distance: 1 mm to 10 mm by 1 mm) were generated. The fluence maps with larger than 1 mm detector-todetector distance were interpolated using MATLAB (R2014a, the Math Works,Natick, MA) by four different interpolation Methods: for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. These interpolated fluence maps were compared with the reference one using the γ value (criteria: 3%, 3 mm) and the relative dose difference. Results: As the detector-to-detector distance increases, the dose difference between the two maps increases. For the fluence map with the same resolution, the cubic spline interpolation and the bicubic interpolation are almost equally best interpolation methods while the nearest neighbor interpolation is the worst.For example, for 5 mm distance fluence maps, γ≤1 are 98.12±2.28%, 99.48±0.66%, 99.45±0.65% and 82.23±0.48% for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. For 7 mm distance fluence maps, γ≤1 are 90.87±5.91%, 90.22±6.95%, 91.79±5.97% and 71.93±4.92 for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. Conclusion: We recommend that the 2-dimensional detector array with high spatial resolution should be used as an IMRT QA tool and that the measured fluence maps should be interpolated using by the cubic spline interpolation or the bicubic interpolation for head and neck IMRT delivery. This work was supported by Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

Comparison of Various Radiation Therapy Techniques in Breast Cancer Where Target Volume Includes Mammaria Interna Region

In breast cancer radiotherapy, the internal mammary lymphatic chain is treated in the target volume in a group of patients with high-risk criteria. Because of the variability of the anatomic region and structures in the irradiation field, there are a number of different techniques in breast radiotherapy. While irradiating the target volume, we also consider minimizing the dose to critical structures such as heart, lung, and contralateral breast tissue. In this study, we evaluated the dose distribution of different radiotherapy techniques in patients with left-sided breast cancer who had breast-conserving surgery. A three-dimensional computerized planning system (3DCPS) was used for each patient to compare wide-field, oblique photon-electron, and perpendicular photon-electron techniques in terms of dose homogeneities in the target volume; the doses received by the contralateral breast, heart, and lung; and the coverage of the internal mammary chain. Data from 3DCPS were controlled by the Rando-phantom and thermoluminescence dosimetry. Critical structures were irradiated with acceptable dose percentages in addition to the internal mammary chain with both wide-field and photon-electron techniques. We detected more frequent hot spots in the oblique photon-electron technique than in the other techniques, and this situation necessitated changing the junctions. The wide-field technique was easy to perform and exposed less radiation dose to the heart than photon-electron techniques. In conclusion, we suggest the use of the wide-field technique in breast irradiation when the internal mammary area is in the target volume.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beam properties and stability of a flattening-filter free 7 MV beam--An overview

Purpose: Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). Methods: Dosimetric properties of the 7XU beam were measured in May and September 2011. We present depth dose curves and beam profiles, output factors, and MLC transmission and assess the stability of the measurements. The 7XU beam was commissioned in the Pinnacle Superscript-Three treatment planning system (TPS), and modeling results including the spectrum are presented. Results: The percent depth dose curve of the 7XU beam is similar to the flat 6X beam line, with a slightly smaller surface dose. The beam profiles show the characteristic shape of flattening-filter free beams, with deviations between measurements of generally less than 1%. The output factors of the 7XU beam decrease more slowly than for the 6X beam. The MLC transmission is comparable but slightly less for the 7XU beam. The 7XU beam can be adequately modeled by the Pinnacle Superscript-Three TPS, with successful dosimetric verification. The spectrum of the 7XU beam has lower photon fluence up to approximately 2.5 MeV and higher fluence beyond, with a slightly higher mean energy. Conclusions: The 7XU beam has been commissioned for clinical use after successful modeling, stability checks, and dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗