Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Design and demonstration of tunable soft x-ray lateral shearing and Hartmann wavefront sensors

We describe design guidelines for soft x-ray wavefront sensors and experimentally demonstrate their performance, comparing grating-based lateral shearing interferometry and Hartmann wavefront sensing. We created a compact shearing interferometer concept with a dense array of binary amplitude gratings in a single membrane to support one-dimensional wavefront measurements across a wide wavelength range without the need for longitudinal position adjustment. We find that a common scaling parameter based on wavelength and the distance to the measurement plane guides the design of both systems toward optimal sensitivity. We show preliminary results from recent experiments demonstrating one and two-dimensional wavefront sensing below the Marechal criterion.

Chao, Weilun↗

Using resonant soft x-ray scattering to image patterns on undeveloped resists

Copyright © 2018 SPIE. Extreme ultraviolet lithography is one of the most promising printing techniques for high volume semiconductor manufacturing at the 14 nm half-pitch device node and beyond. However, key challenges around EUV photoresist materials such as the exposure-dose sensitivity or the line-width roughness continue to impede the full adoption into industrial nanofab facilities. New metrology tools are required to address these challenges by helping to determine the impact of the EUV materials' properties and processing conditions on the roughness through the different step of the process. Here, we apply the resonant soft x-ray scattering (RSOXS) technique to gain insights into the structure of patterned EUV resists before the development step takes place. By using energies around the carbon absorption edge to take advantage of small differences in chemistry, the electronic density contrast between the exposed and unexposed regions of the resists could be enhanced in order to image the patterns with sub-nm precision. Critical-dimension grazing incidence small-angle X-ray scattering (CDGISAXS) was then performed at energies where the contrast was maximized, enabling the reconstruction of the 3D shape of the latent image. This demonstrates the potential of RSOXS to provide a high-resolution heightsensitive profile of patterned EUV resists, which will help to quantify the evolution of critical features, such as the line edge roughness, at each step of the nanofabrication process.

Pandolfi, Ronald J↗

Hybrid method simulations of a soft x-ray beamline

A wavefront propagation analysis of a soft X-ray beamline using the HYBRID method is reported. All elements of the beamline: the energy dependence of the insertion device emission, the beamline mirrors and their measured figure errors, the variable-line-spacing grating and its measured figure error, and several exit slit settings, are included in the simulations. The analysis of the propagated undulator radiation through the beamline at two slightly different deflection parameter values demonstrates that, within the beamline angular acceptance and when the monochromator is tuned to the same energy, the flux is higher when the undulator is tuned to slightly higher energy than that of the monochromator. The energy resolution determined from the FWHM of the energy bandwidth transmitted through the exit slit is narrower when the undulator is tuned to higher energy than the monochromator. This is not the case when the resolution is based on the standard deviation of the transmitted energy band. The diffraction effects due to the exit slit size and their consequence on the spot size at the sample position are investigated for a few photon energies.

beamline↗

Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas

Purpose: To establish accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas. Methods: Protocol patients with advanced extremity sarcomas were treated with external beam radiation therapy and hyperthermia. Invasive temperature measures were compared to noninvasive magnetic resonance thermal imaging (MRTI) at 1.5 T performed during hyperthermia. Volumetric temperature rise images were obtained using the proton resonance frequency shift (PRFS) technique during heating in a 140 MHz miniannular phased array applicator. MRTI temperature changes were compared to invasive measurements of temperature with a multisensor fiber optic probe inside a no. 15 g catheter in the tumor. Since the PRFS technique is sensitive to drifts in the primary imaging magnetic field, temperature change distributions were corrected automatically during treatment using temperature-stable reference materials to characterize field changes in 3D. The authors analyzed MRT images and compared, in evaluable treatments, MR-derived temperatures to invasive temperatures measured in extremity sarcomas. Small regions of interest (ROIs) were specified near each invasive sensor identified on MR images. Temperature changes in the interstitial sensors were compared to the corresponding ROI PRFS-based temperature changes over the entire treatment and over the steady-state period. Nonevaluable treatments (motion/imaging artifacts, noncorrectable drifts) were not included in the analysis. Results: The mean difference between MRTI and interstitial probe measurements was 0.91 deg. C for the entire heating time and 0.85 deg. C for the time at steady state. These values were obtained from both tumor and normal tissue ROIs. When the analysis is done on just the tumor ROIs, the mean difference for the whole power on time was 0.74 deg. C and during the period of steady state was 0.62 deg. C. Conclusions: The data show that for evaluable treatments, excellent correlation ({Delta}T<1 deg. C) of MRTI-ROI and invasive measurements can be achieved, but that motion and other artifacts are still serious challenges that must be overcome in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking

Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID image acquisition at the frame rate of at least 4.29 Hz is recommended. Motion blurring in the images with frame rates below 4.29 Hz can significantly reduce the accuracy of autotracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking

Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the accuracy of auto-tracking. This work is supported in part by the Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-J-24: Can Fiducial Marker-Based Setup Using ExacTrac Be An Alternative to Soft Tissue-Based Setup Using Cone-Beam CT for Prostate IMRT?

Purpose: To assess an accuracy of fiducial maker-based setup using ExacTrac (ExT-based setup) as compared with soft tissue-based setup using Cone-beam CT (CBCT-based setup) for patients with prostate cancer receiving intensity-modulated radiation therapy (IMRT) for the purpose of investigating whether ExT-based setup can be an alternative to CBCT-based setup. Methods: The setup accuracy was analyzed prospectively for 7 prostate cancer patients with implanted three fiducial markers received IMRT. All patients were treated after CBCT-based setup was performed and corresponding shifts were recorded. ExacTrac images were obtained before and after CBCT-based setup. The fiducial marker-based shifts were calculated based on those two images and recorded on the assumption that the setup correction was carried out by fiducial marker-based auto correction. Mean and standard deviation of absolute differences and the correlation between CBCT and ExT shifts were estimated. Results: A total of 178 image dataset were analyzed. On the differences between CBCT and ExT shifts, 133 (75%) of 178 image dataset resulted in smaller differences than 3 mm in all dimensions. Mean differences in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) dimensions were 1.8 ± 1.9 mm, 0.7 ± 1.9 mm, and 0.6 ± 0.8 mm, respectively. The percentages of shift agreements within ±3 mm were 76% for AP, 90% for SI, and 100% for LR. The Pearson coefficient of correlation for CBCT and ExT shifts were 0.80 for AP, 0.80 for SI, and 0.65 for LR. Conclusion: This work showed that the accuracy of ExT-based setup was correlated with that of CBCT-based setup, implying that ExT-based setup has a potential ability to be an alternative to CBCT-based setup. The further work is to specify the conditions that ExT-based setup can provide the accuracy comparable to CBCT-based setup.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-14: Assessment of Inter- and Intra-Fractional Motion for Extremity Soft Tissue Sarcoma Patients by Using In-House Real-Time Optical Image-Based Monitoring System

Purpose: This study aimed to assess inter- and intra-fractional motion for extremity Soft Tissue Sarcoma (STS) patients, by using in-house real-time optical image-based monitoring system (ROIMS) with infra-red (IR) external markers. Methods: Inter- and intra-fractional motions for five extremity (1 upper, 4 lower) STS patients received postoperative 3D conformal radiotherapy (3D-CRT) were measured by registering the image acquired by ROIMS with the planning CT image (REG-ROIMS). To compare with the X-ray image-based monitoring, pre- and post-treatment cone beam computed tomography (CBCT) scans were performed once per week and registered with planning CT image as well (REG-CBCT). If the CBCT scan is not feasible due to the large couch shift, AP and LR on-board imager (OBI) images were acquired. The comparison was done by calculating mutual information (MI) of those registered images. Results: The standard deviation (SD) of the inter-fractional motion was 2.6 mm LR, 2.8 mm SI, and 2.0 mm AP, and the SD of the intra-fractional motion was 1.4 mm, 2.1 mm, and 1.3 mm in each axis, respectively. The SD of rotational inter-fractional motion was 0.6° pitch, 0.9° yaw, and 0.8° roll and the SD of rotational intra-fractional motion was 0.4° pitch, 0.9° yaw, and 0.7° roll. The derived averaged MI values were 0.83, 0.92 for REG-CBCT without rotation and REG-ROIMS with rotation, respectively. Conclusion: The in-house real-time optical image-based monitoring system was implemented clinically and confirmed the feasibility to assess inter- and intra-fractional motion for extremity STS patients while the daily basis and real-time CBCT scan is not feasible in clinic.

60 APPLIED LIFE SCIENCES↗

Visualizing subcellular rearrangements in intact β cells using soft x-ray tomography

Characterizing relationships between cell structures and functions requires mesoscale mapping of intact cells showing subcellular rearrangements following stimulation; however, current approaches are limited in this regard. Here, we report a unique application of soft x-ray tomography to generate three-dimensional reconstructions of whole pancreatic β cells at different time points following glucose-stimulated insulin secretion. Reconstructions following stimulation showed distinct insulin vesicle distribution patterns reflective of altered vesicle pool sizes as they travel through the secretory pathway. Our results show that glucose stimulation caused rapid changes in biochemical composition and/or density of insulin packing, increased mitochondrial volume, and closer proximity of insulin vesicles to mitochondria. Costimulation with exendin-4 (a glucagon-like peptide-1 receptor agonist) prolonged these effects and increased insulin packaging efficiency and vesicle maturation. This study provides unique perspectives on the coordinated structural reorganization and interactions of organelles that dictate cell responses.

59 BASIC BIOLOGICAL SCIENCES↗

Functional soft materials from blue phase liquid crystals

Blue phase (BP) liquid crystals are chiral fluids wherein millions of molecules self-assemble into cubic lattices that are on the order of hundred nanometers. As the unit cell sizes of BPs are comparable to the wavelength of light, they exhibit selective Bragg reflections in the visible. The exploitation of the photonic properties of BPs for technological applications is made possible through photopolymerization, a process that renders mechanical robustness and thermal stability. We review here the preparation and characterization of stimuli-responsive, polymeric photonic crystals based on BPs. We highlight recent studies that demonstrate the promise that polymerized BP photonic crystals hold for colorimetric sensing and dynamic light control. We review using Landau–de Gennes simulations for predicting the self-assembly of BPs and the potential for using theory to guide experimental design. Finally, opportunities for using BPs to synthesize new soft materials, such as highly structured polymer meshes, are discussed.

36 MATERIALS SCIENCE↗

Accessing bands with extended quantum metric in kagome Cs 2 Ni 3 S 4 through soft chemical processing

Flat bands that do not merely arise from weak interactions can produce exotic physical properties, such as superconductivity or correlated many-body effects. The quantum metric can differentiate whether flat bands will result in correlated physics or are merely dangling bonds. A potential avenue for achieving correlated flat bands involves leveraging geometrical constraints within specific lattice structures, such as the kagome lattice; however, materials are often more complex. In these cases, quantum geometry becomes a powerful indicator of the nature of bands with small dispersions. We present a simple, soft-chemical processing route to access a flat band with an extended quantum metric below the Fermi level. By oxidizing Ni-kagome material Cs 2 Ni 3 S 4 to CsNi 3 S 4 , we see a two orders of magnitude drop in the room temperature resistance. However, CsNi 3 S 4 is still insulating, with no evidence of a phase transition. Using experimental data, density functional theory calculations, and symmetry analysis, our results suggest the emergence of a correlated insulating state of unknown origin.

Science & Technology - Other Topics↗

Electron microscopy of phase and structural transformations in soft magnetic nanocrystalline Fe-Zr-N films

The effect of deposition conditions (film thickness) on the structure of soft magnetic Fe{sub 80-78}Zr{sub 10}N{sub 10-12} films formed by reactive magnetron deposition on a heat-resistant glass substrate has been investigated by analytical transmission electron microscopy, high-resolution electron microscopy, and diffraction analysis. The processes of evolution of the phase and structural state of films and the film-substrate interface upon annealing in the temperature range of 200-650 Degree-Sign C have been analyzed taking into account the thermodynamic, kinetic, and structural factors and the specific features of the nanocrystalline state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local-field anisotropy of a light wave in quasi-two-dimensional soft-matter objects

Experimental values of the Lorentz tensor components L{sub j} for uniaxial quasi-two dimensional 'soft matter' objects on substrates (bilayer lipid membranes, multilayer Langmuir films, smectics A, hexatic smectics B, submicron films of discotics Col{sub hd}, micron anisotropic films of liquid-crystal comblike polymers and macromolecular polymers, submicron films of conjugated conductive polymers), freely suspended submicron films of smectics A, and uniaxially stretched micron films of conjugated conductive polymers have been determined using dispersion of refractive indices in the visible range. The dependences of the components L{sub j} on the type of orientation (axial, planar) of uniaxial molecules (structural units of the film) with respect to the optical axis of the film, the film thickness, the substrate type, the chemical structure of molecules, and their long-range orientational order are established. It is revealed that the smectic A-hexatic B phase transition and two-dimensional crystallization of the smectic layer lead to changes in the components L{sub j} due to the change in the orientational ordering of molecules as a result of the relation between the orientational and hexatic order parameters. All the above objects are characterized by isotropization of the Lorentz tensor L and the local-field tensor f with a simultaneous decrease in the birefringence of the sample and in the anisotropy of the molecular polarizability due to the change in the electronic structure of molecules. The correction for the anisotropy of the local-field tensor f to the orientational order parameter or the anisotropy of the molecular polarizability increases. The existing model approaches to calculating the components L{sub j} for the objects under consideration are compared with the experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Universal statistics of soft gamma-ray repeating (SGR) bursts

Soft gamma repeater (SGR) bursts are considered as a release of magnetic energy stored in the baryon degrees of freedom of the magnetar crust. It is shown that this interpretation allows all observations of these bursts to be systematized and universal statistical properties to be revealed and explained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ON PERTURBATIVE QCD OF HARD AND SOFT PROCESSES

We discuss some problems concerning the application of perturbative QCD to high energy processes. In particular for hard processes, we analyze higher order and higher twist corrections. It is argued that these effects are of great importance for understanding the behaviour of pion electromagnetic form factor at moderately large momentum transfers. For soft processes, we show that summing the contributions of the lowest twist operators leads to a Regge-like amplitude.

EFREMOV, A. V.↗