Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum information processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Magnon-magnon coupling in an all-oxide insulator garnet Y 3 ⁢Fe 5 ⁢O 12 /Tm 3 ⁢Fe 5⁢ O 12 heterostructure

Hybrid magnonic systems have recently attracted significant attention due to their intriguing physics and potential applications in coherent information processing. In this regard, we have investigated magnon-magnon coupling in the all-oxide insulator garnet Y 3⁢ Fe 5⁢ O 12 (YIG)/Tm 3 ⁢Fe 5 ⁢O 12 (TmIG) heterostructure. The presence of an avoided mode crossing region between the ferromagnetic resonance modes of YIG and TmIG indicates interfacial exchange coupling. This all-insulator system enables interfacial coupling via magnon-magnon interactions. The mode crossing occurs at 𝑓 𝑐 = 6.88 GHz, corresponding to the minimal resonance separation between the two hybrid modes. The coupling strength is determined to be 78 MHz (or 2.8 mT), providing clear evidence of magnon-magnon coupling between the two Kittel modes in the YIG/TmIG insulator system at 200 K. As a result, these findings pave the way for engineering magnonic band structures, tunable coherent magnonic interactions, and nonreciprocal spin transport, which are crucial for advancing ultralow-power magnonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fault-tolerant neutral-atom architecture for universal quantum computation

Quantum error correction (QEC) is essential for the realization of large-scale quantum computers. However, owing to the complexity of operating on the encoded ‘logical’ qubits, understanding the physical principles for building fault-tolerant quantum devices and combining them into efficient architectures is an outstanding scientific challenge. Here we use reconfigurable arrays of up to 448 neutral atoms to implement the key elements of a universal, fault-tolerant quantum processing architecture and experimentally explore their underlying working mechanisms. We first use surface codes to study how repeated QEC suppresses errors, demonstrating 2.14(13)x below-threshold performance in a four-round characterization circuit by leveraging atom loss detection and machine learning decoding. We then investigate logical entanglement using transversal gates and lattice surgery and extend it to universal logic through transversal teleportation with three-dimensional [[15,1,3]] codes, enabling arbitrary-angle synthesis with polylogarithmic overhead. Finally, we develop mid-circuit qubit reuse16, increasing experimental cycle rates by two orders of magnitude and enabling deep-circuit protocols with dozens of logical qubits and hundreds of logical teleportations with [[7,1,3]] and high-rate [[16,6,4]] codes while maintaining constant internal entropy. Our experiments show key principles for efficient architecture design, involving the interplay between quantum logic and entropy removal, judiciously using physical entanglement in logic gates and magic state generation, and leveraging teleportations for universality and physical qubit reset. These results establish foundations for scalable, universal error-corrected processing and its practical implementation in neutral atom systems.

atomic and molecular physics↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermographic process monitoring in powderbed based additive manufacturing

Selective Laser Melting is utilized to build metallic parts directly from CAD-Data by solidification of thin powder layers through application of a fast scanning laser beam. In this study layerwise monitoring of the temperature distribution is used to gather information about the process stability and the resulting part quality. The heat distribution varies with different kinds of parameters including scan vector length, laser power, layer thickness and inter-part distance in the job layout which in turn influence the resulting part quality. By integration of an off-axis mounted uncooled thermal detector the solidification as well as the layer deposition are monitored and evaluated. Errors in the generation of new powder layers usually result in a locally varying layer thickness that may cause poor part quality. For effect quantification, the locally applied layer thickness is determined by evaluating the heat-up of the newly deposited powder. During the solidification process space and time-resolved data is used to characterize the zone of elevated temperatures and to derive locally varying heat dissipation properties. Potential quality indicators are evaluated and correlated to the resulting part quality: Thermal diffusivity is derived from a simplified heat dissipation model and evaluated for every pixel and cool-down phase of a layer. This allows the quantification of expected material homogeneity properties. Maximum temperature and time above certain temperatures are measured in order to detect hot spots or delamination issues that may cause a process breakdown. Furthermore, a method for quantification of sputter activity is presented. Since high sputter activity indicates unstable melt dynamics this can be used to identify parameter drifts, improper atmospheric conditions or material binding errors. The resulting surface structure after solidification complicates temperature determination on the one hand but enables the detection of potential surface defects on the other hand. These issues and proper key figures for thermographic monitoring of the Selective Laser Melting process are discussed in the paper. Even though microbolometric temperature measurement is limited to repetition rates in the Hz-regime and sub megapixel resolution, current results show the feasibility of process surveillance by thermography for a limited section of the building platform in a commercial system.

42 ENGINEERING↗

S-QGPU: Shared quantum gate processing unit for distributed quantum computing

We propose a distributed quantum computing (DQC) architecture in which individual small-sized quantum computers are connected to a shared quantum gate processing unit (S-QGPU). The S-QGPU comprises a collection of hybrid two-qubit gate modules for remote gate operations. In contrast to conventional DQC systems, where each quantum computer is equipped with dedicated communication qubits, S-QGPU effectively pools the resources (e.g., the communication qubits) together for remote gate operations, and, thus, significantly reduces the cost of not only the local quantum computers but also the overall distributed system. Our preliminary analysis and simulation show that S-QGPU's shared resources for remote gate operations enable efficient resource utilization. When not all computing qubits (also called data qubits) in the system require simultaneous remote gate operations, S-QGPU-based DQC architecture demands fewer communication qubits, further decreasing the overall cost. Alternatively, with the same number of communication qubits, it can support a larger number of simultaneous remote gate operations more efficiently, especially when these operations occur in a burst mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors' algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors' algorithm increases peak signal-to-noise ratio by 3-4 dB and the structural similarity index by 3%-5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It outperforms the conventional interpolation-based approaches by producing images with the markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Dimensionality and noise in energy selective x-ray imaging

Purpose: To develop and test a method to quantify the effect of dimensionality on the noise in energy selective x-ray imaging.Methods: The Cramèr-Rao lower bound (CRLB), a universal lower limit of the covariance of any unbiased estimator, is used to quantify the noise. It is shown that increasing dimensionality always increases, or at best leaves the same, the variance. An analytic formula for the increase in variance in an energy selective x-ray system is derived. The formula is used to gain insight into the dependence of the increase in variance on the properties of the additional basis functions, the measurement noise covariance, and the source spectrum. The formula is also used with computer simulations to quantify the dependence of the additional variance on these factors. Simulated images of an object with three materials are used to demonstrate the trade-off of increased information with dimensionality and noise. The images are computed from energy selective data with a maximum likelihood estimator.Results: The increase in variance depends most importantly on the dimension and on the properties of the additional basis functions. With the attenuation coefficients of cortical bone, soft tissue, and adipose tissue as the basis functions, the increase in variance of the bone component from two to three dimensions is 1.4 × 10{sup 3}. With the soft tissue component, it is 2.7 × 10{sup 4}. If the attenuation coefficient of a high atomic number contrast agent is used as the third basis function, there is only a slight increase in the variance from two to three basis functions, 1.03 and 7.4 for the bone and soft tissue components, respectively. The changes in spectrum shape with beam hardening also have a substantial effect. They increase the variance by a factor of approximately 200 for the bone component and 220 for the soft tissue component as the soft tissue object thickness increases from 1 to 30 cm. Decreasing the energy resolution of the detectors increases the variance of the bone component markedly with three dimension processing, approximately a factor of 25 as the resolution decreases from 100 to 3 bins. The increase with two dimension processing for adipose tissue is a factor of two and with the contrast agent as the third material for two or three dimensions is also a factor of two for both components. The simulated images show that a maximum likelihood estimator can be used to process energy selective x-ray data to produce images with noise close to the CRLB.Conclusions: The method presented can be used to compute the effects of the object attenuation coefficients and the x-ray system properties on the relationship of dimensionality and noise in energy selective x-ray imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutrino-Argon Interaction with GENIE Event Generator

Neutrinos are very special particles, have only weak interactions, except gravity, and are produced in very different processes in Nuclear and Particle Physics. Neutrinos are, also, messengers from astrophysical objects, as well as relics from Early Universe. Therefore, its can give us information on processes happening in the Universe, during its evolution, which cannot be studied otherwise. The underground instrumentation including a variety of large and very large detectors, thanks to technical breakthroughs, have achieved new fundamental results like the solution of the solar neutrino puzzle and the evidence for Physics beyond the Standard Model of elementary interactions in the neutrino sector with non-vanishing neutrino masses and lepton flavour violation.Two of the LAGUNA(Large Apparatus studying Grand Unification and Neutrino Astrophysics) detectors, namely: GLACIER (Giant Liquid Argon Charge Imaging ExpeRiment) and LENA (Low Energy Neutrino Astrophysics) could be emplaced in 'Unirea' salt mine from Slanic-Prahova, Romania. A detailed analysis of the conditions and advantages is necessary. A few results have been presented previously. In the present work, we propose to generate events and compute the cross sections for interactions between neutrino and Argon-40, to estimate possible detection performances and event types. For doing this, we use the code GENIE(G lowbar enerates E lowbar vents for N lowbar eutrino I lowbar nteraction E lowbar xperiments). GENIE Code is an Object-Oriented Neutrino MC Generator supported and developed by an international collaboration of neutrino interaction experts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reliability of unstable periodic orbit based control strategies in biological systems

Presence of recurrent and statistically significant unstable periodic orbits (UPOs) in time series obtained from biological systems is now routinely used as evidence for low dimensional chaos. Extracting accurate dynamical information from the detected UPO trajectories is vital for successful control strategies that either aim to stabilize the system near the fixed point or steer the system away from the periodic orbits. A hybrid UPO detection method from return maps that combines topological recurrence criterion, matrix fit algorithm, and stringent criterion for fixed point location gives accurate and statistically significant UPOs even in the presence of significant noise. Geometry of the return map, frequency of UPOs visiting the same trajectory, length of the data set, strength of the noise, and degree of nonstationarity affect the efficacy of the proposed method. Results suggest that establishing determinism from unambiguous UPO detection is often possible in short data sets with significant noise, but derived dynamical properties are rarely accurate and adequate for controlling the dynamics around these UPOs. A repeat chaos control experiment on epileptic hippocampal slices through more stringent control strategy and adaptive UPO tracking is reinterpreted in this context through simulation of similar control experiments on an analogous but stochastic computer model of epileptic brain slices. Reproduction of equivalent results suggests that far more stringent criteria are needed for linking apparent success of control in such experiments with possible determinism in the underlying dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the approximations applied in the continuum-distorted-wave-eikonal-initial-state theory for the evaluation of ionization cross sections: Post-prior discrepancy, axial symmetry, and ion-ion interaction

When the continuum distorted wave with eikonal initial state (CDW-EIS) [D. S. Crothers and J. F. McCann, J. Phys B 16, 3229 (1983)] theory is applied to the evaluation of ionization cross sections, many additional approximations are assumed. However, usually, the influence of these approximations is not clear. Aiming to estimate them, we compare the differential and total cross sections obtained with diverse approximations for ionization of He atoms by proton impact. We analyze the post-prior discrepancy, which depends on the perturbative Hamiltonian applied in the scattering amplitude. We study the dependence of the cross sections on the description of the initial and final states. For this purpose, we use the 1Z and 5Z variational and numerical Optimized Potential Model (OPM) [J. D. Talman, Comput. Phys. Commun. 54, 85 (1989)] bound states for the initial target state, and for the final target state we set Coulomb waves with proper effective charges or the continuum state of an OPM potential model. The cross sections resulting from OPM post and prior versions are identical and show excellent agreement with experimental data in each case. Nevertheless, the cross section derived by the prior CDW-EIS, 5Z initial wave, and corresponding continuum state gives comparable results, requiring shorter computational work. Then we study the determination of the impact parameter ionization probability from the transition amplitudes, also including an axial symmetry for the ionization process. The hypothesis of this axial symmetry saves an angular integration in the evaluation of the probabilities. We analyze the variation of these probabilities within the post and prior formalisms and mention initial and final states, according to the supposed symmetry. We found that the probabilities derived with the axial symmetry concentrate at a lower impact parameter than the usual ones and are quite sensitive to the approximations used for the CDW-EIS evaluation. Furthermore, these probabilities underestimate distant collisions. In the last section we introduce the projectile-residual ion potential, and we discuss the effect of the diverse approximations on the dependence of the cross section as a function of the projectile scattering angle. We compare the projectile angular distribution resulting from a full Coulomb interaction between the ions with the one obtained by a screened potential, but in the latter case the theoretical distributions underestimate the experimental data. The OPM and 5Z functions give a good description of the experimental data.

74 ATOMIC AND MOLECULAR PHYSICS↗

Theoretically informed Monte Carlo simulation of liquid crystals by sampling of alignment-tensor fields

A theoretically informed coarse-grained Monte Carlo method is proposed for studying liquid crystals. The free energy functional of the system is described in the framework of the Landau-de Gennes formalism. The alignment field and its gradients are approximated by finite differences, and the free energy is minimized through a stochastic sampling technique. The validity of the proposed method is established by comparing the results of the proposed approach to those of traditional free energy minimization techniques. Its usefulness is illustrated in the context of three systems, namely, a nematic liquid crystal confined in a slit channel, a nematic liquid crystal droplet, and a chiral liquid crystal in the bulk. It is found that for systems that exhibit multiple metastable morphologies, the proposed Monte Carlo method is generally able to identify lower free energy states that are often missed by traditional approaches. Importantly, the Monte Carlo method identifies such states from random initial configurations, thereby obviating the need for educated initial guesses that can be difficult to formulate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Out-of-Distribution Generalization for Learning Quantum Channels with Low-Energy Coherent States

When experimentally learning the action of a continuous-variable quantum process by probing it with inputs, there will often be some restriction on the input states used. One experimentally simple way to probe a quantum channel is to use low-energy coherent states. Learning a quantum channel in this way presents difficulties, due to the fact that two channels may act similarly on low-energy inputs but very differently for high-energy inputs. They may also act similarly on coherent-state inputs but differently on nonclassical inputs. Extrapolating the behavior of a channel for more general input states from its action on the far more limited set of low-energy coherent states is a case of out-of-distribution generalization. To be sure that such generalization gives meaningful results, one needs to relate error bounds for the training set to bounds that are valid for all inputs. We show that for any pair of channels that act sufficiently similarly on low-energy coherent-state inputs, one can bound how different the input-output relations are for any (high-energy or highly nonclassical) input. This proves that out-of-distribution generalization is always possible for learning quantum channels using low-energy coherent states, as long as enough samples are used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Bayesian 3D X-ray computed tomography image reconstruction with a scaled Gaussian mixture prior model

In order to improve quality of 3D X-ray tomography reconstruction for Non Destructive Testing (NDT), we investigate in this paper hierarchical Bayesian methods. In NDT, useful prior information on the volume like the limited number of materials or the presence of homogeneous area can be included in the iterative reconstruction algorithms. In hierarchical Bayesian methods, not only the volume is estimated thanks to the prior model of the volume but also the hyper parameters of this prior. This additional complexity in the reconstruction methods when applied to large volumes (from 512{sup 3} to 8192{sup 3} voxels) results in an increasing computational cost. To reduce it, the hierarchical Bayesian methods investigated in this paper lead to an algorithm acceleration by Variational Bayesian Approximation (VBA) [1] and hardware acceleration thanks to projection and back-projection operators paralleled on many core processors like GPU [2]. In this paper, we will consider a Student-t prior on the gradient of the image implemented in a hierarchical way [3, 4, 1]. Operators H (forward or projection) and H{sup t} (adjoint or back-projection) implanted in multi-GPU [2] have been used in this study. Different methods will be evalued on synthetic volume 'Shepp and Logan' in terms of quality and time of reconstruction. We used several simple regularizations of order 1 and order 2. Other prior models also exists [5]. Sometimes for a discrete image, we can do the segmentation and reconstruction at the same time, then the reconstruction can be done with less projections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative Density Functional Theory Study of Magnetic Exchange Couplings in Dinuclear Transition-Metal Complexes

Multicenter transition-metal complexes (MCTMs) with magnetically interacting ions have been proposed as components for information-processing devices and storage units. For any practical application of MCTMs as magnetic units, it is crucial to characterize their magnetic behavior, and in particular, the isotropic magnetic exchange coupling, J, between its magnetic centers. Due to the large size of typical MCTMs, density functional theory is the only practical electronic structure method for evaluating the J coupling. Here, we assess the accuracy of different density functional approximations for predicting the magnetic couplings of eight dinuclear transition-metal complexes, including five dimanganese, two dicopper, and one divanadium with known reliable experimental J couplings spanning from ferromagnetic to strong antiferromagnetic. The density functionals considered include global hybrid functionals which mix semilocal density functional approximations and exact exchange with a fixed admixing parameter, six local hybrid functionals where the admixing parameters are extended to be spatially dependent, the SCAN and r 2 SCAN meta-generalized gradient approximations (GGAs), and two widely used GGAs. We found that global hybrids tested in this work have a tendency to over-correct the error in magnetic coupling parameters from the Perdew–Burke–Ernzerhof (PBE) GGA as seen for manganese complexes. The performance of local hybrid density functionals shows no improvement in terms of bias and is scattered without a clear trend, suggesting that more efforts are needed for the extension from global to local hybrid density functionals for this particular property. The SCAN and r 2 SCAN meta-GGAs are found to perform as well as benchmark global hybrids on most tested complexes. We further analyze the charge density redistribution of meta-GGAs as well as global and local hybrid density functionals with respect to that of PBE, in connection to the self-interaction error or delocalization error.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Probing Linewidths and Biexciton Quantum Yields of Single Cesium Lead Halide Nanocrystals in Solution

Cesium lead halide (CsPbX 3 , X = Cl, Br, I) perovskite nanocrystals (PNCs) have recently become a promising material for optoelectronic applications due to their high emission quantum yields and facile band gap tunability via both halide composition and size. The spectroscopy of single PNCs enhances our understanding of the effect of confinement on excitations in PNCs in the absence of obfuscating ensemble averaging and can also inform synthetic efforts. However, single PNC studies have been hampered by poor PNC photostability under confocal excitation, precluding interrogation of all but the most stable PNCs, and leading to a lack of understanding of PNCs in the regime of high confinement. Here, we report the first comprehensive spectroscopic investigation of single PNC properties using solution-phase photon-correlation methods, including both highly confined and blue-emitting PNCs, previously inaccessible to single NC techniques. With minimally perturbative solution-phase photon-correlation Fourier spectroscopy (s-PCFS), we establish that the ensemble emission linewidth of PNCs of all sizes and compositions is predominantly determined by the intrinsic single PNC linewidth (homogeneous broadening). The single PNC linewidth, in turn, dramatically increases with increasing confinement, consistent with what has been found for II–VI semiconductor nanocrystals. With solution-phase photon antibunching measurements, we survey the biexciton-to-exciton quantum yield ratio (BX/X QY) in the absence of user-selection bias or photodegradation. Remarkably, the BX/X QY ratio depends both on the PNC size and halide composition, with values between ~2% for highly confined bromide PNCs and ~50% for intermediately confined iodide PNCs. Our results suggest a wide range of underlying Auger rates, likely due to transitory charge carrier separation in PNCs with relaxed confinement.

single nanocrystal spectroscopy↗

Purification of Zirconium Tetrachloride from UNF Cladding

The overarching objective of this project was to design and demonstrate (laboratory scale) a sublimation-based purification protocol to obtain pure zirconium chloride (ZrCl 4 ) from impure feeds derived from the direct chlorination of Zircaloy cladding materials. To achieve this objective the following goals were identified. (1) Design, construct and test an apparatus capable of subliming and purifying ZrCl 4 at room pressure and temperatures between 600 and 700K (sublimation point of ZrCl 4 606 K). (2) Investigate reactions that may be used to chemically alter the makeup of the impure ZrCl 4 feed materials to enhance their removal from ZrCl 4 in the sublimation-purification process. (3) Computationally model the reactions of metal chlorides in the gas phase under sublimation conditions (1 atm, 600 K) to determine if oligomers are formed and, if formed, how they would influence sublimation-based purification strategies. All experimental investigations performed as part of this project used stable (non-radioactive) compounds and materials as surrogates for the impure ZrCl 4 feedstocks that would be derived from the direct chlorination of Zircaloy claddings from spent nuclear fuel rods. No radiologically active materials were used at any time in this project. The impure ZrCl 4 feedstocks used in this study were derived from the direct chlorination of virgin Zircaloy claddings (Zirc-2, -4 and high Nb). The main goals of the project have been achieved during the three year period of this NEUP sponsored project. The impurities of greatest concern in the feedstocks were identified as the chloride salts of the alloying metals originally found in Zircaloy (Fe, Nb) and radiological contaminants (Cs, Sr, and Sb). A series of prototype sublimation apparatuses and heating arrangements were designed, constructed and tested. A general batch-sublimator design was identified and a 1.0 kg batch sublimator/oven system was fabricated from glass. Purification protocols developed on small scale runs were found to scale to 1.0 kg batches without problem. Purification factor ranges (PFs: wt% final / wt% initial ) for the impurity chlorides identified above have been measured: Fe (40 – 500); Nb (10 – 70); Cs (520 – 5000); Sr (250 – 1900); Sb (220 – 2300). Removal of iron is sensitive to the partial pressure of hydrogen (in nitrogen) flowing through the system. Lower PFs are obtained when the hydrogen partial pressure is lower. Lower flows are required to raise the iron PF. Removal of niobium is very sensitive to the endpoint determination of the forerun. When judged properly (color change yellow to white in sublimate) reasonable PFs (500) can be achieved. However, as discussed in the conclusions section, endpoint determination can be difficult and significantly lower PFs may be obtained when the endpoint is not correctly identified. Several methods of obtaining quantitative cesium, strontium and antimony PFs were investigated, the best being ICP-MS. The results reported here reflect very limited access to and ICP-MS instrument during the course of this project. It should be noted that, while significantly reduced amounts of antimony are observed in the product, antimony is also found in the exhaust trap after the condenser. Quantum chemical computational modeling studies of the reactions of metal chlorides in the gas phase provided important information about a chemical transport mechanism that could defeat sublimation-based purification strategies. Many metal chlorides are known to oligomerize in the gas phase to reduce their coordinative unsaturation. Dimerization of ZrCl 4 with iron or niobium chlorides would provide a mechanism by which both metal impurities could be carried over with the product during sublimation of the bulk material. Computational modeling conclusively showed that under sublimation conditions in the gas phase, dimerization reactions are not favored thermodynamically due to a significant entropic penalty for the reaction. Therefore, consistent with experimental observations, sublimation-based purification strategies remain viable. The experimental part of the report concludes with a short discussion of the issues that still remain in developing a technologically relevant Zircaloy recycling strategy. The final section of the report is a summary of the quantum chemical investigation of the reactions of metal chlorides in the gas phase under sublimation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗