Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Tunable and angle-insensitive plasmon resonances in graphene ribbon arrays with multispectral diffraction response

Plasmon resonances in graphene ribbon arrays are investigated numerically by means of the Finite Element Method. Numerical analysis shows that a series of multipolar resonances take place when graphene ribbon arrays are illuminated by a TM polarized electromagnetic wave. Moreover, these resonances are angle-independent, and can be tuned greatly by the width and the doping level of the graphene ribbons. Specifically, we demonstrate that for graphene arrays with several sets of graphene ribbons, which have different widths or doping levels, each of these multipolar resonances will be split into several ones. In addition, as plasmon resonances can confine electromagnetic field at the ribbon edges, graphene ribbons with different widths or doping levels offer intriguing application for electrically tunable spectral imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ptychography with broad-bandwidth radiation

Ptychography, a scanning Coherent Diffractive Imaging (CDI) technique, has quickly gained momentum as a robust method to deliver quantitative images of extended specimens. A current conundrum for the development of X-ray CDI is the conflict between a need for higher flux to reach higher resolutions and the requirement to strongly filter the incident beam to satisfy the tight coherence prerequisite of the technique. Latest developments in algorithmic treatment of ptychographic data indicate that the technique is more robust than initially assumed, so that some experimental limitations can be substantially relaxed. Here, we demonstrate that ptychography can be conducted in conditions that were up to now considered insufficient, using a broad-bandwidth X-ray beam and an integrating scintillator-based detector. Our work shows the wide applicability of ptychography and paves the way to high-throughput, high-flux diffractive imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluorescently tuned nitrogen-doped carbon dots from carbon source with different content of carboxyl groups

In this study, fluorescent nitrogen-doped carbon dots (NCDs) were tuned via varying the sources with different number of carboxyl groups. Owing to the interaction between amino and carboxyl, more amino groups conjugate the surface of the NCDs by the source with more carboxyl groups. Fluorescent NCDs were tuned via varying the sources with different content of carboxyl groups. Correspondingly, the nitrogen content, fluorescence quantum yields and lifetime of NCDs increases with the content of carboxyl groups from the source. Furthermore, cytotoxicity assay and cell imaging test indicate that the resultant NCDs possess low cytotoxicity and excellent biocompatibility.

36 MATERIALS SCIENCE↗

Acoustic planar hyperlens based on anisotropic density-near-zero metamaterials

Based on anisotropic density-near-zero metamaterials, we demonstrate a planar hyperlens with resolution beyond the diffraction limit in both one and two lateral dimensions. In contrast to the cylindrical hyperlens with elliptical dispersions of finite anisotropy, the proposed planar hyperlens is designed with flat near-zero dispersion that supports wave tunneling with extremely high phase velocity for infinite large transverse wave vectors. Therefore, the acoustic evanescent waves immediately concentrate into the designed oblique path till the output surface, leading to a subwavelength resolution. Prototype hyperlens is constructed with a membrane-network by means of equivalent lumped-circuit model, and the subwavelength magnifying performance for a pair of one-dimensional line objects as well as the complex two-dimensional structure is demonstrated. This method provides diverse routes to construct hyperlens operating without the limitation on imaging region in practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Q-switched Erbium-doped fiber laser at 1600 nm for photoacoustic imaging application

We present a nanosecond Q-switched Erbium-doped fiber (EDF) laser system operating at 1600 nm with a tunable repetition rate from 100 kHz to 1 MHz. A compact fiber coupled, acousto-optic modulator-based EDF ring cavity was used to generate a nanosecond seed laser at 1600 nm, and a double-cladding EDF based power amplifier was applied to achieve the maximum average power of 250 mW. In addition, 12 ns laser pulses with the maximum pulse energy of 2.4 μJ were obtained at 100 kHz. Furthermore, the Stokes shift by Raman scattering over a 25 km long fiber was measured, indicating that the laser can be potentially used to generate the high repetition rate pulses at the 1.7 μm region. Finally, we detected the photoacoustic signal from a human hair at 200 kHz repetition rate with a pulse energy of 1.2 μJ, which demonstrates that a Q-switched Er-doped fiber laser can be a promising light source for the high speed functional photoacoustic imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Terahertz imaging of Landau levels in HgTe-based topological insulators

We report on sub-terahertz photoconductivity under the magnetic field of a two dimensional topological insulator based on HgTe quantum wells. We perform a detailed visualization of Landau levels by means of photoconductivity measured at different gate voltages. This technique allows one to determine a critical magnetic field, corresponding to topological phase transition from inverted to normal band structure, even in almost gapless samples. The comparison with realistic calculations of Landau levels reveals a smaller role of bulk inversion asymmetry in HgTe quantum wells than it was assumed previously.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Combined Theoretical and Experimental Study of the Polymer Interchain Structure in Poly(phenylene vinylene) Derivatives

The structures and photophysical properties of single molecule MEH-PPV (2-methoxy-5-(2 -ethylhexyloxy)-p-phenylenevinylene) and CN-PPV (2,5,2 ,5 -tetrahexyloxy-7,8 -dicyano-pphenylenevinylene)nanoparticles are investigated with electronic structure theory and high resolution fluorescence experiments. It is shown that electron withdrawing substitutients, such as CN, on the vinyl group of the PPV polymer backbone cause substantial change in the π electronic structure which subsequently decreases the interchain distance. Not only does CN-PPV have a smaller interchain separation compared to MEH-PPV, but also an increased binding energy and more efficient charge transport (carrier mobility) due to larger electronic coupling (charge transfer integrals). These changes help explain the enhanced luminescence quantum yield, photo-stability, and lifetime for CN-PPV versus MEH-PPV observed in experimental high resolution fluorescence imaging of individual single molecule nanoparticles.

36 MATERIALS SCIENCE↗

Three-dimensional coherence of light speckles: Experiment

We provide an experimental detailed study of the three-dimensional coherence properties of light speckles produced by different tunable pseudothermal sources. Our findings confirm the theoretical prediction of the companion article [A. Gatti et al., Phys. Rev. A 78, 063806 (2008)], according to which the longitudinal coherence of the speckles is ruled by ordinary diffraction laws only in the deep-Fresnel zone close to the source, deviates from this behavior in the Fresnel zone, and tends to become infinite when approaching the Fraunhofer zone. A quantitative comparison with theory is presented for Gaussian speckles in all the three regimes and for Airy speckles in the deep-Fresnel zone. Potential applications to three-dimensional imaging techniques are briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interplay of Polarization Geometry and Rotational Dynamics in High-Order Harmonic Generation from Coherently Rotating Linear Molecules

Recent reports on intense-field pump-probe experiments for high-order harmonic generation (HHG) from coherently rotating linear molecules have revealed remarkable characteristic effects of the simultaneous variation of the polarization geometry and the time delay on the high-order harmonic signals. We analyze the effects and give a unified theoretical account of the experimental observations. Furthermore, characteristic behavior at critical polarization angles are found that can help to identify the molecular orbital symmetry in connection with the problem of molecular imaging from the HHG data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Doppler blood flow complementary metal oxide semiconductor imaging sensor with analog on-chip processing

A 4x4 pixel array with analog on-chip processing has been fabricated within a 0.35 {mu}m complementary metal oxide semiconductor process as a prototype sensor for laser Doppler blood flow imaging. At each pixel the bandpass and frequency weighted filters necessary for processing laser Doppler blood flow signals have been designed and fabricated. Because of the space constraints of implementing an accurate {omega}{sup 0.5} filter at the pixel level, this has been approximated using the ''roll off'' of a high-pass filter with a cutoff frequency set at 10 kHz. The sensor has been characterized using a modulated laser source. Fixed pattern noise is present that is demonstrated to be repeatable across the array and can be calibrated. Preliminary blood flow results on a finger before and after occlusion demonstrate that the sensor array provides the potential for a system that can be scaled to a larger number of pixels for blood flow imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Massive all-atom analysis of 2D materials with quantum properties (Final report)

Improvements in microscopy have enabled the acquisition of data at a scale that is difficult to process manually, making automated machine learning approaches to analyzing experimental images essential. In this project, we developed and applied machine learning (ML) workflows for atomic resolution scanning transmission electron microscopy (STEM) images. This development included improving both methodology as well as generating user-friendly codes. We developed machine learning architectures which, after training, automatically identify the location and types of defects throughout a material. We used these data to produce class-averaged images of 2D atomic coordinates with up to 0.3 pm precision, uncovering the structure and oscillations of long-range strain fields around point defects in WSe 2-2x Te 2x . We also resolved a long-standing problem in this field in the training of ML models, a lack of labeled experimental data, by developing a cycle-GAN that transformed simulated-generated labeled data into labeled data indistinguishable from experiment and therefore suitable for training. This removed the remaining parts of the ML data processing workflow where human intervention was still critical and therefore a bottleneck to working at scale. Codes have been developed and released for this full machine learning workflow. ML approaches to partially automate STEM acquisition were also developed. Finally we applied ML and other advanced data processing methods to several materials science problems in two-dimensional materials, including studying the evolution of hyperuniformity with defect concentration in WSe2, understanding phase transformations in transition metal dichalcogenides during in-situ heating in the STEM, and exploring how 2D interfaces transform from twisted into aligned structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long-Wavelength 640 x 486 GaAs/AlGaAs Quantum Well Infrared Photodetector Snap-Shot Camera

A 9-micrometer cutoff 640 x 486 snap-shot quantum well infrared photodetector (QWIP) camera has been demonstrated. The performance of this QWIP camera is reported including indoor and outdoor imaging. The noise equivalent differential temperature (NE.deltaT) of 36 mK has been achieved at 300 K background with f/2 optics. This is in good agreement with expected focal plane array sensitivity due to the practical limitations on charge handling capacity of the multiplexer, read noise, bias voltage, and operating temperature.

Gunapala, Sarath D.↗

Photoluminescence-Imaging-Based Evaluation of Non-Uniform CdTe Degradation

A control algorithm is designed to smooth the variability of PV power output using distributed batteries. The tradeoff between smoothing and battery size is shown. It is also demonstrated that large numbers of highly distributed current, voltage, and irradiance sensors can be utilized to control the distributed storage in a more optimal manner. It is also demonstrated that centralized energy storage control for PV ramp rate smoothing requires very fast communication, typically less than a 15-second update rate. Finally, advanced inverter dynamic reactive current is shown to provide voltage variability smoothing, hence reducing the number of voltage regulator tap changes without energy storage.

14 SOLAR ENERGY↗

Ordered dust structures in a glow discharge

Highly ordered three-dimensional dust structures are created in a striated glow discharge, and their horizontal cross-sectional images are analyzed. Calculated correlation functions, local correlation parameters, and corresponding approximations are used to classify the state of a structure according to the Kosterlitz-Thouless-Halperin-Nelson-Young (KTHNY) two-dimensional melting theory and a phenomenological approach. An orientational map based on an orientational parameter is proposed to expose domains in a cross section of a structure. It is shown that a plasma crystal is a polycrystal consisting of hexagonal domains (crystallites). Thermophoretic forces are used to create corners of various angles in the perimeter of the structure. Transition between hexagonal and square cell shapes is observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atom-atom correlations in time-of-flight imaging of ultracold bosons in optical lattices

We study the spatial correlations of strongly interacting bosons in a ground state, confined in a two-dimensional square and a three-dimensional cubic lattice. Using the combined Bogoliubov method and the quantum rotor approach, we map the Hamiltonian of strongly interacting bosons onto U(1) phase action in order to calculate the atom-atom correlations' decay along the principal axis and a diagonal of the lattice-plane direction as a function of distance. Lower tunneling rates lead to quicker decays of the correlations, whose character becomes exponential. Finally, correlation functions allow us to calculate quantities that are directly bound to experimental outcomes, namely time-of-flight absorption images and resulting visibility. Our results contain all the characteristic features present in experimental data (transition from Mott insulating blob to superfluid peaks, etc.), emphasizing the usability of the proposed approach.

74 ATOMIC AND MOLECULAR PHYSICS↗

Stochastic formulation of patient positioning using linac-mounted cone beam imaging with prior knowledge

Purpose: In this work, a novel stochastic framework for patient positioning based on linac-mounted CB projections is introduced. Based on this formulation, the most probable shifts and rotations of the patient are estimated, incorporating interfractional deformations of patient anatomy and other uncertainties associated with patient setup. Methods: The target position is assumed to be defined by and is stochastically determined from positions of various features such as anatomical landmarks or markers in CB projections, i.e., radiographs acquired with a CB-CT system. The patient positioning problem of finding the target location from CB projections is posed as an inverse problem with prior knowledge and is solved using a Bayesian maximum a posteriori (MAP) approach. The prior knowledge is three-fold and includes the accuracy of an initial patient setup (such as in-room laser and skin marks), the plasticity of the body (relative shifts between target and features), and the feature detection error in CB projections (which may vary depending on specific detection algorithm and feature type). For this purpose, MAP estimators are derived and a procedure of using them in clinical practice is outlined. Furthermore, a rule of thumb is theoretically derived, relating basic parameters of the prior knowledge (initial setup accuracy, plasticity of the body, and number of features) and the parameters of CB data acquisition (number of projections and accuracy of feature detection) to the expected estimation accuracy. Results: MAP estimation can be applied to arbitrary features and detection algorithms. However, to experimentally demonstrate its applicability and to perform the validation of the algorithm, a water-equivalent, deformable phantom with features represented by six 1 mm chrome balls were utilized. These features were detected in the cone beam projections (XVI, Elekta Synergy) by a local threshold method for demonstration purposes only. The accuracy of estimation (strongly varying for different plasticity parameters of the body) agreed with the rule of thumb formula. Moreover, based on this rule of thumb formula, about 20 projections for 6 detectable features seem to be sufficient for a target estimation accuracy of 0.2 cm, even for relatively large feature detection errors with standard deviation of 0.5 cm and spatial displacements of the features with standard deviation of 0.5 cm. Conclusions: The authors have introduced a general MAP-based patient setup algorithm accounting for different sources of uncertainties, which are utilized as the prior knowledge in a transparent way. This new framework can be further utilized for different clinical sites, as well as theoretical developments in the field of patient positioning for radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MEMS terahertz-to-infrared band converter using frequency selective planar metamaterial

A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8THz and 4.75THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A validation of the fibre orientation and fibre length attrition prediction for long fibre-reinforced thermoplastics

To improve the mechanical performance of polymeric parts, fibre reinforcement has established in industrial applications during the last decades. Next to the widely used Short Fibre-reinforced Thermoplastics (SFT) the use of Long Fibre-reinforced Thermoplastics (LFT) is increasingly growing. Especially for non-polar polymeric matrices like polypropylene (PP), longer fibres can significantly improve the mechanical performance. As with every kind of discontinuous fibre reinforcement the fibre orientations (FO) show a high impact on the mechanical properties. On the contrary to SFT where the local fibre length distribution (FLD) can be often neglected, for LFT the FLD show a high impact on the material’s properties and has to be taken into account in equal measure to the FOD. Recently numerical models are available in commercial filling simulation software and allow predicting both the local FOD and FLD in LFT parts. The aim of this paper is to compare i.) the FOD results and ii) the FLD results from available orientation- and fibre length attrition-models to those obtained from experimental data. The investigations are conducted by the use of different injection moulded specimens made from long glass fibre reinforced PP. In order to determine the FOD, selected part sections are examined by means of Computed Tomographic (CT) analyses. The fully three dimensional measurement of the FOD is then performed by digital image processing using grey scale correlation. The FLD results are also obtained by using digital image processing after a thermal pyrolytic separation of the polymeric matrix from the fibres. Further the FOD and the FLD are predicted by using a reduced strain closure (RSC) as well as an anisotropic rotary diffusion - reduced strain closure model (ARD-RSC) and Phelps-Tucker fibre length attrition model implemented in the commercial filling software Moldflow, Autodesk Inc., San Rafael, CA, USA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗