Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

VecPAC: A Vectorizable and Precision-Aware CGRA

This paper proposes VecPAC -- a vectorizable and precision-aware coarse-grained reconfigurable array (CGRA) design. VecPAC integrates CGRA tiles with scalar functional units and specialized tiles with vector functional units that can trade off the number of vector lanes for the accuracy of the computation. We discuss the architecture design and present the related compilation framework. The experimental evaluation on a set of applications from three different domains (embedded, machine learning, and high-performance computing) shows that the hybrid design of VecPAC outperforms CGRAs with only scalar functional units by 1.48x, while providing higher scalability.

Tan, Cheng↗

A Precision, Low-Cost GPS-Based Transmitter Synchronization Scheme for Improved AM Reception

This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to {approx}1 part in 10{sup 9} or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station's carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station's audio at the receiver and concurrent distortion of the audio modulation from the distant station(s) and often cause listeners to ldquotune outrdquo due to the low reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; hybrid digital (HD) signals will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1000-$2000), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long- term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific carrier frequency desired. The stability of the disciplining source, typically {approx}1 part in 10{sup 9} to 10{sup 11}, is thus transferred to the final AM transmitter carrier output frequency.

42 ENGINEERING↗

A Precision Dose Control Circuit for Maskless E-Beam Lithography With Massively Parallel Vertically Aligned Carbon Nanofibers

This paper describes a highly accurate dose control circuit (DCC) for the emission of a desired number of electrons from vertically aligned carbon nanofibers (VACNFs) in a massively parallel maskless e-beam lithography system. The parasitic components within the VACNF device cause a premature termination of the electron emission, resulting in underexposure of the photoresist. In this paper, we compensate for the effects of the parasitic components and noise while reducing the area of the chip and achieving a precise count of emitted electrons from the VACNFs to obtain the optimum dose for the e-beam lithography.

47 OTHER INSTRUMENTATION↗

A Novel Event Detection Method Using PMU Data with High Precision

To take full advantage of the considerably high reporting rate of phasor measurement units (PMU) data, this paper develops a novel PMU-based event detection methodology. Considering the huge amount of streaming PMU data, a data compression algorithm, swinging door trending (SDT), is first used to compress the PMU data and generate multiple compression intervals. Then dynamic programming is utilized to solve the optimization problem, which is recursively constituted by a score function. Based on predefined PMU event rules, dynamic programming merges adjacent compression intervals with the same slope direction. Finally, all the PMU event features are characterized. A conventional wavelet-based event detection method is compared with the developed dynamic programming based SDT (DPSDT) method. Numerical simulations on the real-time and synthetic PMU data show that the DPSDT method can accurately detect the start-time of an event and the event placement with relatively high precision. Furthermore, the PMU event features, including the magnitude and duration of strokes, are characterized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clarifying Terminology in Microbial Ecology: A Call for Precision in Scientific Communication

The rapid evolution of microbiology as a field of research has led to the introduction of new terminology and the adaptation of existing terms. However, inconsistencies in the use of these terms, including variations across different scientific disciplines, can lead to confusion and miscommunication within the scientific community. This article discusses the importance of precise terminology in microbiome research, highlighting examples where terms have been misused or redefined without clear justification. We also present a list of frequently used terms in microbial ecology along with their specific definitions. We argue that the misuse of terminology can hinder scientific progress by creating ambiguity and misunderstanding. To address this, we propose a set of guidelines for the consistent use of key terms and provide clear definitions for some of the most commonly misused or newly introduced terms in the field. The definitions provided herein will also function as a guide for young researchers new to the field of microbial ecology. Accurate and consistent use of terminology is crucial for effective communication and collaboration in microbiology research. By adhering to standardised definitions, researchers can ensure that their work is clearly communicated and contributes meaningfully to the progress of science.

definitions↗

High-Precision Zinc Isotopic Measurement of Certified Reference Materials Relevant to the Environmental, Earth, Planetary and Biomedical Sciences

The zinc (Zn) stable isotope system has emerged as a powerful tool for investigating natural and anthropogenic processes of interest to disciplines extending from the Earth and planetary sciences to biomedical research. In nature, Zn isotopes typically fractionate ( 66 Zn/ 64 Zn) within the range of –1 and +1 permil (‰), and however, analytical limitations restrict the application of the Zn isotope system. Specifically, there is a lack of well-characterised matrix-matched reference materials covering most Zn isotope applications that are essential for validating laboratory performance, particularly given the contamination prone nature of Zn. Furthermore, the increasing demand for analysis of size-limited materials and sample types displaying small, sub-permil level Zn isotope variations requires improvements in measurement procedures. To address these limitations, the δ 66 Zn values of two pure Zn solutions and eighteen reference materials including the previously uncharacterised RGM-2, BCR-279, DOLT-4, DOLT-5, NASS-7, SBC-1, SGR-1b, MESS-3 and HISS-1, and the understudied QLO-1, SDC-1, BCR-414, NASS-6 and COQ-1 materials are reported. Furthermore, a 70 Zn- 67 Zn double-spike design has been implemented that routinely achieves intermediate measurement precision better than ± 0.02‰. This represents at least a two-fold improvement when compared with other double-spike designs, providing a robust platform of δ 66 Zn values required for quality control procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precise and high-speed control of partial pressures of multiple gas species in plasma process chamber using pulse-controlled gas injection

Multiprocesses in a single plasma process chamber with high throughput require precise, sequential, high-speed alteration of partial pressures of multiple gas species. A conventional gas-distribution system cannot realize this because the system seriously overshoots gas pressure immediately following valve operation. Furthermore, chamber volume and conductance of gas piping between the system and chamber should both be considered because they delay the stabilizing time of gas pressure. Therefore, the authors proposed a new gas-distribution system without overshoot by controlling gas flow rate based on pressure measurement, as well as a method of pulse-controlled gas injection immediately following valve operation. Time variation of measured partial pressure agrees well with a calculation based on an equivalent-circuit model that represents the chamber and gas piping between the system and chamber. Using pulse-controlled gas injection, the stabilizing time can be reduced drastically to 0.6 s for HBr added to pure Ar plasma, and 0.7 s for O{sub 2} added to Ar/HBr plasma; without the pulse control, the stabilizing times are 3 and 7 s, respectively. In the O{sub 2} addition case, rapid stabilization can be achieved during the period of line/space pattern etching of poly-Si on a thin SiO{sub 2} film. This occurs without anomalous etching of the underlying SiO{sub 2} film or the Si substrate near the sidewall, thus obtaining a wide process margin with high throughput.

36 MATERIALS SCIENCE↗

Atomic precision imaging with an on-chip scanning tunneling microscope integrated into a commercial ultrahigh vacuum STM system

In this article, we replace the Z axis of the piezotube of a conventional Ultrahigh-Vacuum (UHV) Scanning Tunneling Microscope (STM) with a one-degree-of-freedom Microelectromechanical-System (MEMS) nanopositioner. As a result, a hybrid system is realized in which motions in the XY plane are carried out by the piezotube, while the MEMS device performs the Z-axis positioning with a smaller footprint and higher sensitivity. With the proposed system and a feedback loop, STM imaging is conducted on an H-passivated Si (100)-2×1 sample in a UHV condition, demonstrating that this on-chip STM is conducive to atomic precision scanning tunneling microscopy.

Engineering↗

Precision fabrication of large area silicon-based geometrically enhanced x-ray photocathodes using plasma etching

Geometrically enhanced photocathodes are currently being developed for use in applications that seek to improve detector efficiency in the visible to X-ray ranges. Various photocathode surface geometries are typically chosen based on the detector operational wavelength region, along with requirements such as spatial resolution, temporal resolution and dynamic range. Recently, a structure has been identified for possible use in the X-ray region. This anisotropic high aspect ratio structure has been produced in silicon using inductively coupled plasma (ICP) etching technology. The process is specifically developed with respect to the pattern density and geometry of the photocathode chip to achieve the desired sidewall profile angle. The tapered sidewall profile angle precision has been demonstrated to be within ± 2.5° for a ~ 12° wall angle, with feature sizes that range between 4-9 μm in diameter and 10-25 μm depth. Here we discuss the device applications, design and present the method used to produce a set of geometrically enhanced high yield X-ray photocathodes in silicon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increasing Baselines and Precision of Optical Interferometers Using Two-Photon Interference

Observations using interferometers provide sensitivity to features of images on angular scales much smaller than any single telescope, on the order of Δθ ~ λ/b where b is the interferometric baseline. Present-day optical interferometers are essentially classical, interfering single photons with themselves. However, there is a new wave of interest in interferometry using multiple photons, whose mechanisms are inherently quantum mechanical, which offer the prospects of increased baselines and finer resolutions among other advantages. We will discuss recent ideas and results for quantum-assisted interferometry using the resource of entangled pairs, and specifically a two-photon amplitude technique aimed at improved precision in astrometry.

47 OTHER INSTRUMENTATION↗

Anniversary Paper: Role of medical physicists and the AAPM in improving geometric aspects of treatment accuracy and precision

The last 50 years have seen great advances in the accuracy of external beam radiation therapy. Geometrical uncertainties have been reduced from a centimeter or more in presimulation, skin-mark guided days to 1-2 mm in today's image-guided radiation therapy treatments. Medical physicists, with the support and guidance of the American Association of Physicists in Medicine (AAPM), have been, and continue to be, at the forefront of research, development and clinical implementation in this area. This article reviews some of the major contributions of physicists to the improvement of treatment accuracy and precision, and speculates as to what the future may bring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MLC quality assurance using EPID: A fitting technique with subpixel precision

Amorphous silicon based electronic portal imaging devices (EPIDs) have been shown to be a good alternative to radiographic film for routine quality assurance (QA) of multileaf collimator (MLC) positioning accuracy. In this work, we present a method of acquiring an EPID image of a traditional strip-test image using analytical fits of the interleaf and leaf abutment image signatures. After exposure, the EPID image pixel values are divided by an open field image to remove EPID response and radiation field variations. Profiles acquired in the direction orthogonal to the leaf motion exhibit small peaks caused by interleaf leakage. Gaussian profiles are fitted to the interleaf leakage peaks, the results of which are, using multiobjective optimization, used to calculate the image rotational angle with respect to the collimator axis of rotation. The relative angle is used to rotate the image to align the MLC leaf travel to the image pixel axes. The leaf abutments also present peaks that are fitted by heuristic functions, in this case modified Lorentzian functions. The parameters of the Lorentzian functions are used to parameterize the leaf gap width and positions. By imaging a set of MLC fields with varying gaps forming symmetric and asymmetric abutments, calibration curves with regard to relative peak height (RPH) versus nominal gap width are obtained. Based on this calibration data, the individual leaf positions are calculated to compare with the nominal programmed positions. The results demonstrate that the collimator rotation angle can be determined as accurate as 0.01 deg. . A change in MLC gap width of 0.2 mm leads to a change in RPH of about 10%. For asymmetrically produced gaps, a 0.2 mm MLC leaf gap width change causes 0.2 pixel peak position change. Subpixel resolution is obtained by using a parameterized fit of the relatively large abutment peaks. By contrast, for symmetrical gap changes, the peak position remains unchanged with a standard deviation of 0.05 pixels, or 0.026 mm. A trial run of 36 test images, each with gap widths varying from 0.4 to 1.4 mm, were used to analyze 8640 abutments. The leaf position variations were detected with a precision of 0.1 mm at a 95% confidence level, with a mean of 0.04 mm and a standard deviation of 0.03 mm. The proposed method is robust and minimizes the effect of image noise and pixel size and may help physicists to establish reliable and reasonable action levels in routine MLC QA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Millimeter precision in ultrasound based patient positioning: Experimental quantification of inherent technical limitations

Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematic and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-E-05: Improving Contouring Precision and Consistency for Physicians-In-Training with Simple Lab Experiments

Purpose: Target contouring for high-dose treatments such as radiosurgery of brain metastases is highly critical in eliminating marginal failure and reducing complications as shown by recent clinical studies. In order to improve contouring accuracy and practice consistency for the procedure, we introduced a self-assessed physics lab practice for the physicians-in-training. Methods: A set of commercially acquired high-precision PMMA plastic spheres were randomly embedded in a Styrofoam block and then scanned with the CT/MR via the clinical procedural imaging protocol. A group of first-year physicians-in-training (n=6) from either neurosurgery or radiation oncology department were asked to contour the scanned objects (diameter ranged from 0.4 cm to 3.8 cm). These user-defined contours were then compared with the ideal contour sets of object shape for self assessments to determine the maximum areas of the observed discrepancies and method of improvements. Results: The largest discrepancies from initial practice were consistently found to be located near the extreme longitudinal portions of the target for all the residents. Discrepancy was especially prominent when contouring small objects < 1.0 cm in diameters. For example, the mean volumes rendered from the initial contour data set differed from the ideal data set by 7.7%±6.6% for the participants (p> 0.23 suggesting agreement cannot be established). However, when incorporating a secondary imaging scan such as reconstructed coronal or sagittal images in a repeat practice, the agreement was dramatically improved yielding p<0.02 in agreement with the reference data set for all the participants. Conclusion: A simple physics lab revealed a common pitfall in contouring small metastatic brain tumors for radiosurgical procedures and provided a systematic tool for physicians-in-training in improving their clinical contouring skills. Dr Ma is current a board member of international stereotactic radiosurgical society.

60 APPLIED LIFE SCIENCES↗

SU-E-P-54: Evaluation of the Accuracy and Precision of IGPS-O X-Ray Image-Guided Positioning System by Comparison with On-Board Imager Cone-Beam Computed Tomography

Purpose: The purpose of this study is to assess the positioning accuracy and precision of IGPS-O system which is a novel radiographic kilo-voltage x-ray image-guided positioning system developed for clinical IGRT applications. Methods: IGPS-O x-ray image-guided positioning system consists of two oblique sets of radiographic kilo-voltage x-ray projecting and imaging devices which were equiped on the ground and ceiling of treatment room. This system can determine the positioning error in the form of three translations and three rotations according to the registration of two X-ray images acquired online and the planning CT image. An anthropomorphic head phantom and an anthropomorphic thorax phantom were used for this study. The phantom was set up on the treatment table with correct position and various “planned” setup errors. Both IGPS-O x-ray image-guided positioning system and the commercial On-board Imager Cone-beam Computed Tomography (OBI CBCT) were used to obtain the setup errors of the phantom. Difference of the Result between the two image-guided positioning systems were computed and analyzed. Results: The setup errors measured by IGPS-O x-ray image-guided positioning system and the OBI CBCT system showed a general agreement, the means and standard errors of the discrepancies between the two systems in the left-right, anterior-posterior, superior-inferior directions were −0.13±0.09mm, 0.03±0.25mm, 0.04±0.31mm, respectively. The maximum difference was only 0.51mm in all the directions and the angular discrepancy was 0.3±0.5° between the two systems. Conclusion: The spatial and angular discrepancies between IGPS-O system and OBI CBCT for setup error correction was minimal. There is a general agreement between the two positioning system. IGPS-O x-ray image-guided positioning system can achieve as good accuracy as CBCT and can be used in the clinical IGRT applications.

60 APPLIED LIFE SCIENCES↗

SU-E-J-147: Monte Carlo Study of the Precision and Accuracy of Proton CT Reconstructed Relative Stopping Power Maps

Purpose: The quantification of the intrinsic performances of proton computed tomography (pCT) as a modality for treatment planning in proton therapy. The performance of an ideal pCT scanner is studied as a function of various parameters. Methods: Using GATE/Geant4, we simulated an ideal pCT scanner and scans of several cylindrical phantoms with various tissue equivalent inserts of different sizes. Insert materials were selected in order to be of clinical relevance. Tomographic images were reconstructed using a filtered backprojection algorithm taking into account the scattering of protons into the phantom. To quantify the performance of the ideal pCT scanner, we study the precision and the accuracy with respect to the theoretical relative stopping power ratios (RSP) values for different beam energies, imaging doses, insert sizes and detector positions. The planning range uncertainty resulting from the reconstructed RSP is also assessed by comparison with the range of the protons in the analytically simulated phantoms. Results: The results indicate that pCT can intrinsically achieve RSP resolution below 1%, for most examined tissues at beam energies below 300 MeV and for imaging doses around 1 mGy. RSP maps accuracy of less than 0.5 % is observed for most tissue types within the studied dose range (0.2–1.5 mGy). Finally, the uncertainty in the proton range due to the accuracy of the reconstructed RSP map is well below 1%. Conclusion: This work explores the intrinsic performance of pCT as an imaging modality for proton treatment planning. The obtained results show that under ideal conditions, 3D RSP maps can be reconstructed with an accuracy better than 1%. Hence, pCT is a promising candidate for reducing the range uncertainties introduced by the use of X-ray CT alongside with a semiempirical calibration to RSP.Supported by the DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP)

60 APPLIED LIFE SCIENCES↗

SU-E-T-627: Precision Modelling of the Leaf-Bank Rotation in Elekta’s Agility MLC: Is It Necessary?

Purpose: To demonstrate the method used to determine the leaf bank rotation angle (LBROT) as a parameter for modeling the Elekta Agility multi-leaf collimator (MLC) for Monte Carlo simulations and to evaluate the clinical impact of LBROT. Methods: A detailed model of an Elekta Infinity linac including an Agility MLC was built using the EGSnrc/BEAMnrc Monte Carlo code. The Agility 160-leaf MLC is modelled using the MLCE component module which allows for leaf bank rotation using the parameter LBROT. A precise value of LBROT is obtained by comparing measured and simulated profiles of a specific field, which has leaves arranged in a repeated pattern such that one leaf is opened and the adjacent one is closed. Profile measurements from an Agility linac are taken with gafchromic film, and an ion chamber is used to set the absolute dose. The measurements are compared to Monte Carlo (MC) simulations and the LBROT is adjusted until a match is found. The clinical impact of LBROT is evaluated by observing how an MC dose calculation changes with LBROT. A clinical Stereotactic Body Radiation Treatment (SBRT) plan is calculated using BEAMnrc/DOSXYZnrc simulations with different input values for LBROT. Results: Using the method outlined above, the LBROT is determined to be 9±1 mrad. Differences as high as 4% are observed in a clinical SBRT plan between the extreme case (LBROT not modeled) and the nominal case. Conclusion: In small-field radiation therapy treatment planning, it is important to properly account for LBROT as an input parameter for MC dose calculations with the Agility MLC. More work is ongoing to elucidate the observed differences by determining the contributions from transmission dose, change in field size, and source occlusion, which are all dependent on LBROT. This work was supported by OCAIRO (Ontario Consortium of Adaptive Interventions in Radiation Oncology), funded by the Ontario Research Fund.

61 RADIATION PROTECTION AND DOSIMETRY↗