Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a high efficiency for the calibration method.

, standards, surface roughness, interference micro↗

Nuclear ground-state masses and deformations: FRDM(2012)

We tabulate the atomic mass excesses and binding energies, ground-state shell-plus-pairing corrections, ground-state microscopic corrections, and nuclear ground-state deformations of 9318 nuclei ranging from {sup 16}O to A=339. The calculations are based on the finite-range droplet macroscopic and the folded-Yukawa single-particle microscopic nuclear-structure models, which are completely specified. Relative to our FRDM(1992) mass table in Möller et al. (1995), the results are obtained in the same model, but with considerably improved treatment of deformation and fewer of the approximations that were necessary earlier, due to limitations in computer power. The more accurate execution of the model and the more extensive and more accurate experimental mass data base now available allow us to determine one additional macroscopic-model parameter, the density-symmetry coefficient L, which was not varied in the previous calculation, but set to zero. Because we now realize that the FRDM is inaccurate for some highly deformed shapes occurring in fission, because some effects are derived in terms of perturbations around a sphere, we only adjust its macroscopic parameters to ground-state masses. The values of ten constants are determined directly from an optimization to fit ground-state masses of 2149 nuclei ranging from {sup 16}O to {sub 106}{sup 265}Sg and {sub 108}{sup 264}Hs. The error of the mass model is 0.5595 MeV for the entire region of nuclei included in the adjustment, but is only 0.3549 MeV for the region N≥65. We also provide masses in the FRLDM, which in the more accurate treatments now has an error of 0.6618 MeV, with 0.5181 MeV for nuclei with N≥65, both somewhat larger than in the FRDM. But in contrast to the FRDM, it is suitable for studies of fission and has been extensively so applied elsewhere, with FRLDM(2002) constants. The FRLDM(2012) fits 31 fission-barrier heights from {sup 70}Se to {sup 252}Cf with a root-mean-square deviation of 1.052 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of deoxygenation-aeration cycling to control the predatory bacterium Vampirovibrio chlorellavorus in Chlorella sorokiniana cultures

A previously untested approach was evaluated to enable management of the predatory bacterium, Vampirovibrio chlorellavorus, a pathogen of Chlorella sorokiniana, in suspension cultures grown in a laboratory test reactor. Because V. chlorellavorus is an obligate aerobic bacterium, whereas C. sorokiniana grows under aerobic and anaerobic conditions, deoxygenation of the culture was expected to be detrimental to the pathogen, but not to the algal host. The effect of deoxygenation on the uninfected (healthy) C. sorokiniana suspension cells, compared to the C. sorokiniana-V. chlorellavorus co-culture, was studied in relation to biomass, dissolved oxygen, ratio of C. sorokiniana to V. chlorellavorus DNA, and visual and light microscopic observations. Preliminary experiments were conducted to test the effects of different deoxygenation-aeration cycling regimes on performance of V. chlorellavorus-free C. sorokiniana cultures. To an aerobic culture, pure nitrogen gas was introduced to create anoxic conditions, followed by the injection of ambient air to re-establish an aerobic environment. Under this repeated cycling regime, C. sorokiniana was shown to tolerate the anoxic conditions for extended timespans that ranged from 2 to 8 h over a 5-day test period. The analogous aerobic-anoxic cycling with the C. sorokiniana-V. chlorellavorus co-cultures resulted in ‘near-normal’ growth cycle and harvestable biomass, whereas the continuously-aerated (aerobic) co-cultures that were grown without the deoxygenation step in the cycle collapsed in 3 days. Visual and light microscopic observations revealed intact C. sorokiniana cells were present in the deoxygenated cultures, compared to the aerobically-grown, brown-colored algal cultures consisting of collapsed cells. Quantitative polymerase chain reaction analysis showed continuous increases in the ratio of V. chlorellavorus (16S rDNA) to C. sorokiniana (18S rDNA) DNA in the aerated co-cultures, with greater increases during dark periods, while the pathogen-to-host DNA ratio in the deoxygenated co-cultures was relatively low and algal cells did not collapse, as would be expected following pathogen attack.

Algae, Anoxic, Bomass, Infection, Nitrogen, Quanti↗

Determinants of Toxicity, Patterns of Failure, and Outcome Among Adult Patients With Soft Tissue Sarcomas of the Extremity and Superficial Trunk Treated With Greater Than Conventional Doses of Perioperative High-Dose-Rate Brachytherapy and External Beam Radiotherapy

Purpose: The present study was undertaken to determine factors predictive of toxicity, patterns of failure, and survival in 60 adult patients with soft tissue sarcomas of the extremity and superficial trunk treated with combined perioperative high-dose-rate brachytherapy and external beam radiotherapy. Methods and Materials: The patients were treated with surgical resection and perioperative high-dose-rate brachytherapy (16 or 24 Gy) for negative and close/microscopically positive resection margins, respectively. External beam radiotherapy (45 Gy) was added postoperatively to reach a 2-Gy equivalent dose of 62.9 and 72.3 Gy, respectively. Adjuvant chemotherapy with ifosfamide and doxorubicin was given to patients with advanced high-grade tumors. Results: Grade 3 toxic events were observed in 18 patients (30%) and Grade 4 events in 6 patients (10%). No Grade 5 events were observed. A location in the lower limb was significant for Grade 3 or greater toxic events on multivariate analysis (p = .013), and the tissue volume encompassed by the 150% isodose line showed a trend toward statistical significance (p = .086). The local control, locoregional control, and distant control rate at 9 years was 77.4%, 69.5%, and 63.8%, respectively. On multivariate analysis, microscopically involved margins correlated with local control (p = .036) and locoregional control (p = .007) and tumor size correlated with distant metastases (p = .004). The 9-year disease-free survival and overall survival rate was 47.0% and 61.5%, respectively. Multivariate analysis showed poorer disease-free survival rates for patients with tumors >6 cm (p = .005) and microscopically involved margins (p = .043), and overall survival rates decreased with increasing tumor size (p = .011). Conclusions: Grade 3 or greater wound complications can probably be decreased using meticulous treatment planning to decrease the tissue volume encompassed by the 150% isodose line, especially in lower limb locations. Microscopically involved margins remain a predictor of local and locoregional failure, despite radiation doses >70 Gy. Patients with tumors {>=}6 cm and microscopically involved margins are at high risk of treatment failure and death from the development of distant metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Recipe for Clinical Target Volume and Planning Target Volume Margins

Purpose: To develop a combined recipe for clinical target volume (CTV) and planning target volume (PTV) margins. Methods and Materials: A widely accepted PTV margin recipe is M{sub geo} = aΣ{sub geo} + bσ{sub geo}, with Σ{sub geo} and σ{sub geo} standard deviations (SDs) representing systematic and random geometric uncertainties, respectively. On the basis of histopathology data of breast and lung tumors, we suggest describing the distribution of microscopic islets around the gross tumor volume (GTV) by a half-Gaussian with SD Σ{sub micro}, yielding as possible CTV margin recipe: M{sub micro} = ƒ(N{sub i}) × Σ{sub micro}, with N{sub i} the average number of microscopic islets per patient. To determine ƒ(N{sub i}), a computer model was developed that simulated radiation therapy of a spherical GTV with isotropic distribution of microscopic disease in a large group of virtual patients. The minimal margin that yielded D{sub min} <95% in maximally 10% of patients was calculated for various Σ{sub micro} and N{sub i}. Because Σ{sub micro} is independent of Σ{sub geo}, we propose they should be added quadratically, yielding for a combined GTV-to-PTV margin recipe: M{sub GTV-PTV} = √([aΣ{sub geo}]{sup 2} + [ƒ(N{sub i})Σ{sub micro}]{sup 2}) + bσ{sub geo}. This was validated by the computer model through numerous simultaneous simulations of microscopic and geometric uncertainties. Results: The margin factor ƒ(N{sub i}) in a relevant range of Σ{sub micro} and N{sub i} can be given by: ƒ(N{sub i}) = 1.4 + 0.8log(N{sub i}). Filling in the other factors found in our simulations (a = 2.1 and b = 0.8) yields for the combined recipe: M{sub GTV-PTV} = √((2.1Σ{sub geo}){sup 2} + ([1.4 + 0.8log(N{sub i})] × Σ{sub micro}){sup 2}) + 0.8σ{sub geo}. The average margin difference between the simultaneous simulations and the above recipe was 0.2 ± 0.8 mm (1 SD). Calculating M{sub geo} and M{sub micro} separately and adding them linearly overestimated PTVs by on average 5 mm. Margin recipes based on tumor control probability (TCP) instead of D{sub min} criteria yielded similar results. Conclusions: A general recipe for GTV-to-PTV margins is proposed, which shows that CTV and PTV margins should be added in quadrature instead of linearly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual Tumor After Neoadjuvant Chemoradiation Outside the Radiation Therapy Target Volume: A New Prognostic Factor for Survival in Esophageal Cancer

Purpose/Objective(s): The aim of this study was to analyze the accuracy of gross tumor volume (GTV) delineation and clinical target volume (CTV) margins for neoadjuvant chemoradiation therapy (neo-CRT) in esophageal carcinoma at pathologic examination and to determine the impact on survival. Methods and Materials: The study population consisted of 63 esophageal cancer patients treated with neo-CRT. GTV and CTV borders were demarcated in situ during surgery on the esophagus, using anatomical reference points to provide accurate information regarding tumor location at pathologic evaluation. To identify prognostic factors for disease-free survival (DFS) and overall survival (OS), a Cox regression analysis was performed. Results: After resection, macroscopic residual tumor was found outside the GTV in 7 patients (11%). Microscopic residual tumor was located outside the CTV in 9 patients (14%). The median follow-up was 15.6 months. With multivariate analysis, only microscopic tumor outside the CTV (hazard ratio [HR], 4.96; 95% confidence interval [CI], 1.03-15.36), and perineural growth (HR, 5.77; 95% CI, 1.27-26.13) were identified as independent prognostic factors for OS. The 1-year OS was 20% for patients with tumor outside the CTV and 86% for those without (P<.01). For DFS, microscopic tumor outside the CTV (HR, 5.92; 95% CI, 1.89-18.54) and ypN+ (HR, 3.36; 95% CI, 1.33-8.48) were identified as independent adverse prognostic factors. The 1-year DFS was 23% versus 77% for patients with or without tumor outside the CTV (P<.01). Conclusions: Microscopic tumor outside the CTV is associated with markedly worse OS after neo-CRT. This may either stress the importance of accurate tumor delineation or reflect aggressive tumor behavior requiring new adjuvant treatment modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AM metal substrates for inkjet-printing of smart devices

Highlights: • An experimental study to characterize 3D-printed metal substrates and their surfaces for inkjet-printing is presented. • Multilayer structures composed of an insulating layer and a superposed conductive layer, inkjet-printed onto various metallic substrates. • Characterization based on microscopic and Focused Ion Beam (FIB) images, profilometer and contact angle measurements of the substrates. • Microscopic images and four-point-probe resistance- and profilometer measurements to gain insight into the quality of the multilayer print. - Abstract: A study to characterize surface and structural properties of 3D-printed metal substrates for multilayer inkjet-printing is presented. Such substrates can enable and alleviate the fabrication of smart and functional packages, implants or spare parts. For the characterization, a multilayer structure composed of an insulating layer and a superposed conductive layer is inkjet-printed onto the various 3D-printed metallic substrates. The printing is done using equivalent settings for all substrates. The characterization is based on microscopic and Focused Ion Beam (FIB) images, as well as profilometer and contact angle measurements of the substrates. Furthermore, microscopic images and four-point-probe resistance- and profilometer measurements are carried out, to gain insight into the quality of the multilayer print. We show the diversity in surface and structural properties of 3D-printed substrates, also for those fabricated using the same process. Also, the 3D-printed samples exhibit different wettability properties than metals processed using standard processes. Finally, we can also demonstrate the suitability of selected substrates for inkjet-printing.

36 MATERIALS SCIENCE↗

Effect of Nb micro-alloying on microstructure and properties of thermo-mechanically processed high carbon pearlitic steel

Highlights: • Effect of Nb micro-alloying on high carbon steels has been established. • Fine and degenerated pearlite with fine PAGS is achieved due to Nb micro-alloying. • AFM study indicates true interlamellar spacing which conforms well to TEM study. • Hardness and yield strength have been obviously improved with the addition of Nb. - Abstract: Two C-Mn-Si steels with and without Nb micro-alloying are selected in the present study. Both these high carbon steels have been thermo-mechanically processed using Gleeble 3800 simulator. Optical microscope (OM), scanning electron microscope (SEM), transmission electron microscope (TEM), atomic force microscope (AFM) were utilised for microstructural characterisation. The austenitising temperature was varied from 1150 °C to 1200 °C followed by hot compression and subjected to free cooling to evaluate the influence of austenite grain size on transformed microstructure and mechanical properties. It is evident that higher austenite grain size is obtained for both types of steels subjected to higher austenitising temperature. The refinement of pearlite interlamellar spacing (<0.20 μm) with degenerated morphology as well as finer prior austenite grain size (<40 μm) is found to be more prominent for Nb micro-alloyed sample. The average hardness values of both the steels are higher for the specimens, treated at a higher austenitising temperature which is attributed to finer interlamellar spacing. Finally, the correlation between the evolving microstructure and resulting mechanical properties (hardness and yield strength) has been made.

36 MATERIALS SCIENCE↗

Facile synthesis, optical and photoconductive properties of novel ZnO nanocones

Large-scale, uniform ZnO nanocones with tips about 200 nm and length about 50 {mu}m have been synthesized by a facile hydrothermal method. The morphology and structures were characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), transmission electron microscope (TEM) and high-resolution transmission electron microscope (HR-TEM). The effects of reaction time and PEG-400 on the morphology of ZnO nanostructures were investigated, also an oriented attachment mechanism has been briefly proposed. The optical properties were investigated by lasing confocal microscope and photoluminescence spectrum, a strong near band edge emission peak centered at 387 nm from the ZnO nanocones was observed in photoluminescence spectrum. Finally, we have fabricated UV photodetector based on single ZnO nanocone, which present good switching properties by turning the UV light on and off.

36 MATERIALS SCIENCE↗

Microemulsion-assisted solvothermal synthesis of Nd{sub 2}(CO{sub 3}){sub 3}.8H{sub 2}O microstructures

Research highlights: {yields} Pyramid-like and spherical Nd{sub 2}(CO{sub 3}){sub 3}.8H{sub 2}O microstructures were synthesized using a microemulsion-assisted solvothermal method with precise control of the reaction time and reaction temperature. {yields} The obtained products were characterized by X-ray diffraction (XRD), differential scanning calorimetry and thermal gravimetric analysis (DSC-TGA), scanning electron microscope (SEM), transmission electron microscope (TEM) and electron diffraction (ED). {yields} The increase in size of pyramid-like Nd{sub 2}(CO{sub 3}){sub 3}.8H{sub 2}O microstructures with increasing reaction time was attributed to the typical Ostwald ripening process, while the increase in size of spherical Nd{sub 2}(CO{sub 3}){sub 3}.8H{sub 2}O microstructures with increasing reaction temperature was explained by the increasing collision probability of microemulsion droplets. -- Abstract: Microstructures of Nd{sub 2}(CO{sub 3}){sub 3}.8H{sub 2}O with various morphological structures and sizes were successfully synthesized using the microemulsion-assisted solvothermal method. The obtained products were characterized by X-ray diffraction (XRD), differential scanning calorimetry and thermal gravimetric analysis (DSC-TGA), scanning electron microscope (SEM), transmission electron microscope (TEM) and electron diffraction (ED). The results showed that pyramid-like and spherical Nd{sub 2}(CO{sub 3}){sub 3}.8H{sub 2}O microstructures were synthesized depending on the reaction time and reaction temperature. Moreover, the reaction time and temperature also played important roles in controlling the morphologies and sizes of the resulting Nd{sub 2}(CO{sub 3}){sub 3}.8H{sub 2}O microstructures.

36 MATERIALS SCIENCE↗

Magneto acoustical emission in nanocrystalline Mn–Zn ferrites

Graphical abstract: Mn{sub 0.4}Zn{sub 0.6}Fe{sub 2}O{sub 4} powders were prepared by microwave hydrothermal method. The powders were characterized by X-ray diffraction, transmission electron microscope. The powders were sintered at different temperatures 400, 500, 600, 700, 800 and 900 °C/30 min using microwave sintering method. The grain size was estimated by scanning electron microscope. The room temperature dielectric and magnetic properties were studied in the frequency range (100 kHz–1.8 GHz). The magnetization properties were measured upto 1.5 T. The acoustic emission has been measured along the hysteresis loops from 80 K to Curie temperature. It is found that the magneto-acoustic emission (MAE) activity along hysteresis loop is proportional to the hysteresis losses during the same loop. This law has been verified on series of polycrystalline ferrites and found that the law is valid whatever the composition, the grain size and temperature. It is also found that the domain wall creation/or annihilation processes are the origin of the MAE. - Highlights: • The AE been measured along the hysteresis loops from 80 K to Curie temperature. • The MAE activity along hysteresis loop is proportional to P{sub h} during the same loop. • It is found that the domain wall creation/or annihilation processes are the origin of the MAE. - Abstract: Mn{sub 0.4}Zn{sub 0.6}Fe{sub 2}O{sub 4} powders were prepared by microwave hydrothermal method. The powders were characterized by X-ray diffraction, transmission electron microscope. The powders were sintered at different temperatures 400, 500, 600, 700, 800 and 900 °C/30 min using microwave sintering method. The grain size was estimated by scanning electron microscope. The room temperature dielectric and magnetic properties were studied in the frequency range (100 kHz–1.8 GHz). The magnetization properties were measured upto 1.5 T. The acoustic emission has been measured along the hysteresis loops from 80 K to Curie temperature. It is found that the magneto-acoustic emission (MAE) activity along hysteresis loop is proportional to the hysteresis losses during the same loop. This law has been verified on series of polycrystalline ferrites and found that the law is valid whatever the composition, the grain size and temperature. It is also found that the domain wall creation/or annihilation processes are the origin of the MAE.

36 MATERIALS SCIENCE↗

Multicolor Three-Dimensional Tracking for Single-Molecule Fluorescence Resonance Energy Transfer Measurements

Single-molecule fluorescence resonance energy transfer (smFRET) remains a widely utilized and powerful tool for quantifying heterogeneous interactions and conformational dynamics of biomolecules. However, traditional smFRET experiments either are limited to short observation times (typically less than 1 ms) in the case of “burst” confocal measurements or require surface immobilization which usually has a temporal resolution limited by the camera framing rate. We developed a smFRET 3D tracking microscope that is capable of observing single particles for extended periods of time with high temporal resolution. The confocal tracking microscope utilizes closed-loop feedback to follow the particle in solution by recentering it within two overlapping tetrahedral detection elements, corresponding to donor and acceptor channels. We demonstrated the microscope’s multicolor tracking capability via random walk simulations and experimental tracking of 200 nm fluorescent beads in water with a range of apparent smFRET efficiency values, 0.45-0.69. We also demonstrated the microscope’s capability to track and quantify double-stranded DNA undergoing intramolecular smFRET in a viscous glycerol solution. In future experiments, the smFRET 3D tracking system will be used to study protein conformational dynamics while diffusing in solution and native biological environments with high temporal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Connecting Hindered Transport in Porous Media across Length Scales: From Single-Pore to Macroscopic

Hindered mass transport is widely observed in various porous media, including filtration membranes and porous rocks. However, there is no universal model capable of predicting transport in porous media due to the heterogeneity of porous structures and the complexity of the underlying microscopic mechanisms, including electrostatic and hydrodynamic effects. Here, we used a highly ordered porous medium (i.e. a silica inverse opal film) as a model system to directly explore the effects of geometric parameters (i.e. pore size, pore throat size and tracer particle size) and microscopic interaction parameters (e.g. controlled by ionic strength) on nanoparticle transport in porous environments using three-dimensional single-particle tracking. We found a linear scaling relation between the macroscopic diffusion coefficient and microscopic diffusion behaviors and a combination of parameters associated with microscopic features and phenomena, including both geometric effects and particle-level interactions. The proportionality coefficient relating micro and macro behaviors was complex and related to the connectivity of the matrix and pore-size variation, which could lead to tortuous diffusion pathways, hindering macroscopic transport. Furthermore, these findings provide important insights into nanoparticles and macromolecules transport in various porous media.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Coarse-Grained Modeling of Cholesterol-Containing Lipid Bilayers

In mammalian cells cholesterol is essential for membrane function, but in excess can be cytototoxic. The cellular response to acute cholesterol loading involves biophysical-based mechanisms that regulate cholesterol levels, through modulation of the “activity” or accessibility of cholesterol to extra-membrane acceptors. Experiments and united atom (UA) simulations show that at high concentrations of cholesterol, lipid bilayers thin significantly and cholesterol availability to external acceptors increases substantially. Such cholesterol activation is critical to its trafficking within cells. Here we aim to reduce the computational cost to enable simulation of large and complex systems involved in cholesterol regulation, such as those including oxysterols and cholesterol-sensing proteins. To accomplish this, we have modified the published MARTINI coarse-grained force field to improve its predictions of cholesterol-induced changes in both macroscopic and microscopic properties of membranes. Most notably, MARTINI fails to capture both the (macroscopic) area condensation and membrane thickening seen at less than 30% cholesterol and the thinning seen above 40% cholesterol. The thinning at high concentration is critical to cholesterol activation. Microscopic properties of interest include cholesterol-cholesterol radial distribution functions (RDFs), tilt angle, and accessible surface area. First, we develop an “angle-corrected” model wherein we modify the coarse-grained bond angle potentials based on atomistic simulations. This modification significantly improves prediction of macroscopic properties, most notably the thickening/thinning behavior, and also slightly improves microscopic property prediction relative to MARTINI. Second, we add to the angle correction a “volume correction” by also adjusting phospholipid bond lengths to achieve a more accurate volume per molecule. The angle + volume correction substantially further improves the quantitative agreement of the macroscopic properties (area per molecule and thickness) with united atom simulations. However, this improvement also reduces the accuracy of microscopic predictions like radial distribution functions and cholesterol tilt below that of either MARTINI or the angle-corrected model. Thus, while both of our forcefield corrections improve MARTINI, the combined angle and volume correction should be used for problems involving sterol effects on the overall structure of the membrane, while our angle-corrected model should be used in cases where the properties of individual lipid and sterol models are critically important.

biomembrane↗

Pathways of aqueous Cr(VI) attenuation in a slightly alkaline oxic subsurface

Column experiments combined with geochemical modeling, microscopic inspections and spectroscopic interrogations were conducted with four freshly or naturally aged contaminated sediments with concentrated Cr(VI) waste fluids. The objective was to determine sediment-dependent Cr(VI) desorption extent and rates, Cr(VI) physical location and soil mineral associations, and mechanism(s) of Cr(VI) attenuation under mild alkaline conditions. Results showed that majority of Cr(VI) mass was easily removed from all sediments. Equilibrium site Kd varied from 0 to 0.33 ml g-1 and equilibrium site fraction was greater than 95 %. In addition, long tailings of time-dependent Cr(VI) concentrations above Environmental Protection Agency maximum concentration limit (MCL) of 1.9 µmol L-1, were also observed (kinetic site Kd and desorption reaction half-life varied from 0 to 45 ml g-1, and 76.1 to 126 h, respectively). Aqueous phase pH, particle size distribution and pore water composition contributed to the variability observed among sediments. Microscopic and spectroscopic studies confirmed that Cr was concentrated within fine-grained coatings in small areas rich in phyllosilicates that contained mixed valence [Cr(III)/Cr(VI)]. However, Cr(VI) reduction was neither significant nor complete. The kinetically controlled Cr(VI) desorption may have resulted from the transport (diffusion) of Cr(VI) out of these areas. In summary, at least four pools of Cr(VI) with different leaching behavior might be present in sediments exposed to concentrated waste fluids: i.) The pool of highly mobile and easily removed Cr(VI) (over 95% of total Cr); ii.) The pool of Cr(VI) held in remote sites that provided a long-term continuing source of contaminant Cr; iii.) The pool of reduced immobile Cr(III) which was formed, most likely, by redox reactions of aqueous Cr(VI) and aqueous, sorbed, or structural Fe(II); vi.) The pool of sparingly soluble Cr(VI) phases (e.g., BaCrO4) or solid solutions which did not contribute to the overall Cr(VI) transport under these conditions.

54 ENVIRONMENTAL SCIENCES↗

Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields

Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.

Kang, Iksung↗

Electronic Structure, Dielectric Response and Surface Charge Distribution of RGD (1FUV) Peptide

Long and short range molecular interactions govern molecular recognition and self-assembly of biological macromolecules. Microscopic parameters in the theories of these molecular interactions are either phenomenological or need to be calculated within a microscopic theory. We report a unified methodology for the ab initio quantum mechanical (QM) calculation that yields all the microscopic parameters, namely the partial charges as well as the frequency-dependent dielectric response function, that can then be taken as input for macroscopic theories of electrostatic, polar, and van der Waals-London dispersion intermolecular forces. We apply this methodology to obtain the electronic structure of the cyclic tripeptide RGD-4C (1FUV). This ab initio unified methodology yields the relevant parameters entering the long range interactions of biological macromolecules, providing accurate data for the partial charge distribution and the frequency-dependent dielectric response function of this peptide. These microscopic parameters determine the range and strength of the intricate intermolecular interactions between potential docking sites of the RGD-4C ligand and its integrin receptor.

36 MATERIALS SCIENCE↗

Validation of x-ray microfocus computed tomography as an imaging tool for porous structures

X-ray microfocus computed tomography (micro-CT) is recently put forward to qualitatively and quantitatively characterize the internal structure of porous materials. However, it is known that artifacts such as the partial volume effect are inherently present in micro-CT images, thus resulting in a visualization error with respect to reality. This study proposes a validation protocol that in the future can be used to quantify this error for porous structures in general by matching micro-CT tomograms to microscopic sections. One of the innovations of the protocol is the opportunity to reconstruct an interpolated micro-CT image under the same angle as the physical cutting angle of the microscopic sections. Also, a novel thresholding method is developed based on matching micro-CT and microscopic images. In this study, titanium porous structures are assessed as proof of principle. It is concluded for these structures that micro-CT visualizes 89% of the total amount of voxels (solid and pore) correctly. However, 8% represents an overestimation of the real structure and 3% are real structural features not visualized by micro-CT. When exclusively focusing on the solid fraction in both the micro-CT and microscopic images, only an overestimation of about 5% is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗