Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Efficiency and Demand Flexibility in Large Office Buildings

Data is associated with Report "Efficiency and Demand Flexibility in Large Office Buildings" by Joyce McLaren, Thomas Bowen, and Chioke Harris ( https://doi.org/10.2172/1989231 ). Results are created from repos GEB_ECM_Impact_Estimator ( https://github.nlr.gov/tbowen/GEB_ECM_Impact_Estimator ). Results outline the changes in building load in large office buildings based on measures from NREL's Scout, and the impacts those changes in load have on grid-induced emissions, grid operating costs, and customer bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection: Preprint

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

Design optimization of an ethanol heavy-duty engine using design of experiments and bayesian optimization

Diesel-fueled engines still hold a large market share in the medium and heavy-duty transportation sector. However, the increase in fossil fuel prices and the strict emission regulations are leading engine manufacturers to seek cleaner alternatives without a compromise in performance. Alcohol-based fuels, such as ethanol, offer a promising alternative to diesel fuel in meeting regulatory demands. Ethanol provides cleaner combustion and lower levels of soot due to its chemical properties, in particular its lower level of carbon content. In addition, the stoichiometric operating conditions of alcohol fueled engines enable the mitigation of NOx emissions in aftertreatment stage. With the promise of retrofitting diesel engines to run on ethanol to reduce emissions, the thermal efficiency of these engines remains the primary optimization target. In order to find the optimal ethanol-fueled engine design that maximizes the thermal efficiency, a large design space needs to be investigated using engineering tools. In this study, previous research by the authors on optimizing the design of a single-cylinder ethanol-fueled engine was extended to explore the design space for a heavy-duty multi-cylinder engine configuration. A heavy-duty engine setup with multiple operating conditions at different engine speeds and loads were considered. A design optimization analysis was performed to identify the potential designs that maximize the indicated thermal efficiency in an ethanol-fueled compression ignition engine. First, a computational fluid dynamics (CFD) model of the engine was validated using experimental data for four drive cycle points. Using a design of experiments (DoE) approach and a parameterized piston bowl geometry, the model was then exercised to explore the relationship among geometric features of the piston bowl and spray targeting angle and indicated thermal efficiency across all tested operating conditions. After evaluating 165~candidate designs, a piston bowl geometry was identified that yielded an increase between 1.3 to 2.2 percentage points in indicated thermal efficiency for all tested conditions, while satisfying the operational design constraints for peak pressure and maximum pressure rise rate. The increased performance was attributed to enhanced mixing that led to the formation of a more homogeneous distribution of in-cylinder temperature and equivalence ratio, higher combustion temperatures, and shorter combustion duration. Finally, a Bayesian optimization (BOpt) analysis was employed to find the optimal piston bowl geometry with a fixed spray injector angle for one of the operating conditions. Using BOpt, a piston candidate was identified that resulted in a 1.9~percentage point increase in thermal efficiency from the baseline design, yet only required 65\% of the design samples investigated using the DoE approach.

Tekgul, Bulut↗

FTR for: Reducing plug-load electricity footprint of residential buildings through low-cost, non-intrusive sub-metering and personalized feedback technology

The project started in October 2016 and ended in December 2022. The project's principal goals and achievements were: (i) Measure real and reactive electric power consumption in ~400 apartments in multifamily settings of varying size and vintage and publish the data; data was published according to New York State's recommended 15x15 rule continuously from Jan 2019 through December 2022 (10 second time resolution); with the combination of large number of apartments, real and reactive power, as well as high time resolution (10-seconds), the dataset is first of its kind worldwide; because the dataset New York City apartment consumption pre, during, and post pandemic, it further offers unique insights into changes in residential electricity consumption during lockdowns and after modified work from home schedules. (ii) Measure effectiveness of different feedback types to prompt residents to lower their electricity consumption; achieved 11% (kWh-weighted) reduction versus baseline consumption; confirmed previous studies that social comparisons elicit above average responses; showed, for the first time, that the so called boomerang effect in power consumption feedback projects can be explained by a previously hypothesized norm-conforming "magnet effect" (rather than a non-conforming defiance effect), thus substantially advancing the research in the field. (iii) Disaggregate apartment-level consumption to appliance level; because the hardware for electricity consumption unexpectedly allowed only for 10-second time resolution (rather than the 1-second resolution we had planned on), the disaggregation algorithms we developed on sample data could not be applied to the actual field data we collected. The project has yielded high visibility, with a total of 17 publications, from peer reviewed journals, published data sets (free access), blog posts, NY Times, National Public Radio, and CNN.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multiscale modeling of twinning and detwinning behavior of HCP polycrystals

A multiscale scheme is presented here to capture the twinning and detwinning mechanisms during cyclic loading of HCP polycrystals. In the current framework, the crystal plasticity finite element (CPFE) method is employed at the microstructural scale. The response of twinned regions at a material point is calculated using a novel homogenization scheme via a Taylor-type model. The homogenized behavior is then used in the CPFE to obtain the response of a polycrystal. An efficient rate-independent crystal plasticity model that has been incorporated into the open source PRISMS-Plasticity software is introduced here to capture the response of the twinned region. Accordingly, the corresponding algorithmic tangent modulus is derived. Finally, this multiscale scheme is validated against data available for the cyclic response of Mg alloy ZK60A. The results show that the multiscale model can capture the key elements of the sample response observed during the experiment.

36 MATERIALS SCIENCE↗

One‐Pot Synthesis of Xanthone by Carbonylative Suzuki Coupling Reaction

Abstract Xanthone derivatives have a dibenzo‐y‐pyrone scaffold which has gained great interest in Medicinal Chemistry due to their diverse biological activities. Usually, its synthesis requires multi‐step synthetic routes using harsh conditions and high catalyst loadings. In this communication, we report for the first time a one‐pot synthesis of the xanthone scaffold based on a carbonylative Suzuki coupling. Iodophenol and (2‐methoxyphenyl)boronic acid were coupled under carbon monoxide, generated from a carbon monoxide surrogate. An experimental data‐based model was built to guide the reaction optimization. The optimized conditions were 1 mol% of a pincer complex as palladium catalyst, 5 equivalents of K 2 CO 3 as base, and DMF:water (7 : 3) as solvent. The robustness of the synthetic method, namely in terms of the reactants scope, was also evaluated. This approach provided the xanthone scaffold in high yields and provided a deep insight into the carbonylative Suzuki couplings.

Loureiro, Daniela R. P.↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

Combining cross-pivot flexures to generate improved kinematically equivalent flexure systems

In this work, we show that new kinematic equivalents with improved performance of standard flexure elements can be systematically synthesized by combination of cross-pivot flexures. Cross-pivot flexures provide a unique feature of kinematic stability under both high loading and large displacement conditions which can be exploited to synthesize a range of kinematic equivalents to standard flexure elements which retain much greater stiffness, load capacity and range capacity than the traditional elements. Cross-pivot synthetic elements provide a means to expand the performance of a large range of flexure-based structures including motion stages, manufacturing equipment and optical systems. This could result in better data collection, smaller systems, and less distortion in operation.

42 ENGINEERING↗

Net Load Redistribution Attacks on Nodal Voltage Magnitude Estimation in AC Distribution Networks

A high penetration level of smart devices and communication networks increases the threat of cyber-attacks in the distribution system. In this paper, we model a hidden, coordinated, net load redistribution attack (NLRA) in an AC distribution system. Based on local information of an attack region, the attacker’s goal is to create violations in nodal voltage magnitude estimation. Acting as a system operator equipped with global AC state estimation and bad data detection, we validate the stealthiness of the hidden NLRA in multiple attack cases. Simulation results on a modified PG&E 69-node distribution system show the validity of the proposed NLRA. The influence of NLRA on the distribution system is assessed and the impact of attack regions, attack timing, and system observability is also revealed.

Zhang, Hang↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗

Effect of Fatigue on the Capacity and Performance of Structural Concrete

The goal of this project was to enhance the understanding of the fatigue behavior of concrete structures for the purpose of improving the design and assessment of towers and foundations that support wind turbines, which must endure repeated loadings from wind, waves, operations, and other dynamic effects that cause material degradation. This was achieved through physical experiments, a review of the technical literature, and collaboration with experts in key subject areas. The project produced a comprehensive database of publicly available fatigue data, several technical papers presenting the research findings, and two Technotes to be published by the American Concrete Institute that advance best practices in fatigue testing and enable the development of concrete-specific fatigue (S-N) (stress-life) curves. These contributions are expected to enhance the durability and cost-effectiveness of wind turbine support structures.

17 WIND ENERGY↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1d Raw Data

Fig1d results were obtained using a 3-electrode configuration with IrOx as the counter electrode and saturated calomel electrode as the reference electrode. Two Si/GaN photocathodes were compared. Sample #1 (named as S#1) was the as-received sample, and sample #2 (named as S#2) was CA tested for 4 hours under same testing conditions described in Fig.1a. The PEC performance (J-V curve) was recorded for both samples. Then a photodeposition of Pt was performed on both samples, each loading time was set to be 5 minutes, then the J-V curve was recorded to track the changes of the performance. The Pt photodeposition was stopped until the J-V curve won't shift (the maximum onset potential was achieved). The results show that, S#1 needs at least 20 minutes of Pt photodeposition to achieve its best PEC performance while S#2, which is after CA testing, only needs 5 minutes of Pt photodeposition to achieve its best PEC performance.

photocathode↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building-to-Grid Modeling Framework with a Case Study of Battery Systems

Coordinating electricity load shifting operations of multiple buildings has the potential to achieve significant benefits for both building owners and grid operation. In support of this research, this paper develops a novel building-to-grid modeling framework, which uses EnergyPlus to develop physics-based building energy models and GridLAB-D to develop distribution-level grid models. The data exchanges between buildings and distribution-level grid are conducted using Python script and HELICS co-simulation platform. Then, by using this modeling framework, this paper conducts a case study of battery systems in a connected community, which consists of 10 multi-family buildings with appropriately sized batteries. The three scenarios, baseline operation, tolerant to price fluctuations, and opportune usage, are studied. The result displays that, by adopting onsite batteries, both electricity costs for building owners and aggregated peak power demands are reduced.

Building-to-grid, connected community, co-simulati↗

Data Centers and Digital Assurance Workshop 2 – Prioritizing Digital Assurance Challenges, Session 2

The second session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 10, 2025, focused on prioritizing digital assurance challenges at the intersection of data centers and the electric grid. Building on the foundational concepts introduced in Workshop 1, this session deepened the application of the Threat–Vulnerability–Consequence (TVC) framework and emphasized the urgency of addressing cybersecurity, supply chain integrity, and operational reliability. Participants explored the growing convergence of digital and physical systems, the expanding attack surface due to global supply chain dependencies, and the implications of AI-driven load behavior. Real-world incidents—including the Volt Typhoon campaign and vulnerabilities in Solarman and Deye platforms—were analyzed to illustrate the risks of unpatched systems, insecure APIs, and inadequate vendor oversight. Key themes included architecture and interface weaknesses, governance gaps, and human and procedural shortcomings. The workshop also examined the evolving regulatory landscape, highlighting new federal mandates around Foreign Entity of Concern (FEOC) compliance and large-load reliability standards. Through interactive exercises, stakeholders ranked and mapped digital assurance risks from their respective perspectives—utilities, operators, and vendors—laying the groundwork for mitigation strategies and shared accountability models to be developed in Workshop 3. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Autoignition of CRC diesel surrogates at low temperature combustion conditions: Rapid compression machine experiments and modeling

As federal programs require increasingly stringent engine emissions and fuel economy standards, these ambitions can only be met if next-generation combustion technology is developed focusing on high-efficiency and low-emissions engines. Recent research has indicated the need to operate engines at higher compression ratios and with low temperature combustion (LTC) to achieve the needed gains in engine efficiency and reductions in emissions. Because there is a lack of understanding of the chemistry of diesel fuel components and their mixtures at these LTC conditions, this limits the ability to develop predictive chemical kinetic models that can be used to optimize engine combustion. The current study aims to fill in gaps in fundamental combustion data on surrogate fuel mixtures relevant to diesel fuels. Specifically, four multicomponent diesel surrogates formulated by the Coordinating Research Council (CRC) to emulate an ultra-low-sulfur research-grade #2 certification diesel fuel (CFA), namely V0a (4 components), V0b (5 components), V1 (8 components), and V2 (9 components), have been investigated in a rapid compression machine (RCM) through determination of total and first-stage ignition delay times. Autoignition characteristics of lean to rich fuel/O 2 /N 2 mixtures, for the four CRC surrogates and CFA, have been measured using an RCM at LTC relevant pressures and temperatures, in the ranges of 10–20 bar and 650–1000 K, respectively. The equivalence ratios have been varied by independently changing the oxygen mole fraction and the fuel mole fraction in the test mixtures, thereby illustrating the individual effects of oxygen concentration and fuel loading on diesel autoignition. Autoignition results of these four CRC surrogates are compared among them and with those of CFA. Some degree of agreement in autoignition response between each CRC surrogate and CFA is observed, while discrepancies are also identified and discussed. In addition, a detailed chemical kinetic model for diesel surrogates has been developed and validated against these newly-acquired RCM data. We find that this model shows reasonable agreement with the overall ignition delay time results of the current RCM experiments. Chemical kinetic analyses of the developed model were further conducted to help identify the reactions controlling the autoignition processes and the consumption of fuel components in CRC surrogates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗