Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Sugar loading is not required for phloem sap flow in maize plants

We report phloem transport of photoassimilates from leaves to non-photosynthetic organs, such as the root and shoot apices and reproductive organs, is crucial to plant growth and yield. For nearly 90 years, evidence has been generally consistent with the theory of a pressure-flow mechanism of phloem transport. Central to this hypothesis is the loading of osmolytes, principally sugars, into the phloem to generate the osmotic pressure that propels bulk flow. Here we used genetic and light manipulations to test whether sugar import into the phloem is required as the driving force for phloem sap flow. Using carbon-11 radiotracer, we show that a maize sucrose transporter1 (sut1) loss-of-function mutant has severely reduced export of carbon from photosynthetic leaves (only ~4% of the wild type level). Yet, the mutant remarkably maintains phloem pressure at ~100% and sap flow speeds at ~50–75% of those of wild type. Potassium (K+) abundance in the phloem was elevated in sut1 mutant leaves. Fluid dynamic modelling supports the conclusion that increased K+ loading compensated for decreased sucrose loading to maintain phloem pressure, and thereby maintained phloem transport via the pressure-flow mechanism. Furthermore, these results suggest that sap flow and transport of other phloem-mobile nutrients and signalling molecules could be regulated independently of sugar loading into the phloem, potentially influencing carbon–nutrient homoeostasis and the distribution of signalling molecules in plants encountering different environmental conditions.

36 MATERIALS SCIENCE↗

Paclitaxel loading in cationic liposome vectors is enhanced by replacement of oleoyl with linoleoyl tails with distinct lipid shapes

Abstract Lipid carriers of hydrophobic paclitaxel (PTX) are used in clinical trials for cancer chemotherapy. Improving their loading capacity requires enhanced PTX solubilization. We compared the time-dependence of PTX membrane solubility as a function of PTX content in cationic liposomes (CLs) with lipid tails containing one (oleoyl; DOPC/DOTAP) or two (linoleoyl; DLinPC/newly synthesized DLinTAP) cis double bonds by using microscopy to generate kinetic phase diagrams. The DLin lipids displayed significantly increased PTX membrane solubility over DO lipids. Remarkably, 8 mol% PTX in DLinTAP/DLinPC CLs remained soluble for approximately as long as 3 mol% PTX (the solubility limit, which has been the focus of most previous studies and clinical trials) in DOTAP/DOPC CLs. The increase in solubility is likely caused by enhanced molecular affinity between lipid tails and PTX, rather than by the transition in membrane structure from bilayers to inverse cylindrical micelles observed with small-angle X-ray scattering. Importantly, the efficacy of PTX-loaded CLs against prostate cancer cells (their IC50 of PTX cytotoxicity) was unaffected by changing the lipid tails, and toxicity of the CL carrier was negligible. Moreover, efficacy was approximately doubled against melanoma cells for PTX-loaded DLinTAP/DLinPC over DOTAP/DOPC CLs. Our findings demonstrate the potential of chemical modifications of the lipid tails to increase the PTX membrane loading while maintaining (and in some cases even increasing) the efficacy of CLs. The increased PTX solubility will aid the development of liposomal PTX carriers that require significantly less lipid to deliver a given amount of PTX, reducing side effects and costs.

36 MATERIALS SCIENCE↗

On the effect of metal loading on the reducibility and redox chemistry of ceria supported Pd catalysts

The effect of Pd loading on the redox characteristics of a ceria support was examined using in situ Pd K-edge XAS, Ce L 3 -edge XAS and in situ X-ray diffraction techniques. Analysis of the data obtained from these techniques indicates that the onset temperature for the partial reduction of Ce(IV) to Ce(III), by exposure to H 2 , varies inversely with the loading of Pd. Whilst the onset and completion temperatures of the reduction of Ce(IV) to Ce(III) are different, both samples yield the same maximal fraction of Ce(III) formation independent of Pd loading. Furthermore, the partial reduction of Ce is found to be concurrent with the reduction of PdO and demonstrated that the presence of metallic Pd is necessary for the reduction of the CeO 2 support. Upon passivation by room temperature oxidation, a full oxidation of the reduced ceria support was observed. However, only a mild surface oxidation of Pd was identified. The mild passivation of the Pd is found to lead to a highly reactive sample upon a second reduction by H 2 . The onset of the reduction of Pd and Ce has been demonstrated to be independent of the Pd loading after a mild passivation with both samples exhibiting near room temperature reduction in the presence of H 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon nanodot precursors enable ultrahigh-loading copper single-atom catalysts for oxygen reduction reaction

Single-atom catalysts (SACs) have attracted significant attention in electrocatalysis due to their high metal utilization and tunable electronic structures; however, their practical implementation is often limited by poor atomic dispersion, low metal loadings (typically < 1 wt%), and insufficient anchoring of single metal atoms on catalyst supports. Herein, we report a simple and versatile strategy to synthesize copper single-atom catalysts (Cu-SACs) with ultrahigh metal loading using citric-acid-derived carbon nanodots as metal-capturing precursors. Through hydrothermal treatment followed by pyrolysis in the presence of urea, atomically dispersed copper atoms coordinated with nitrogen are incorporated into a carbon framework, achieving a Cu loading of up to 20 wt% while maintaining atomic dispersion. Notably, a significant fraction of the copper single atoms exists as Cu+–N2 coordination, which provides under-coordinated and catalytically active sites. The resulting Cu-SAC exhibits promising oxygen reduction reaction (ORR) activity in alkaline media, delivering a limiting current density comparable to that of commercial 20 wt% Pt/C with a predominant four-electron reduction pathway. Despite this high intrinsic activity, durability tests reveal gradual performance degradation under prolonged electrochemical operation, which is attributed to demetallation and aggregation of copper single atoms into metallic nanoparticles. These results demonstrate the potential of carbon nanodot-based platforms for synthesizing high-loading SACs, while underscoring the critical need to simultaneously control carbon porosity and metal–nitrogen coordination to enhance active-site accessibility and durability.

Sharma, Prakhar [University of Kentucky]↗

Surface runoff from full-scale coal combustion product pavements during accelerated loading

In this study, the release of metals and metalloids from full-scale portland cement concrete pavements containing coal combustion products (CCPs) was evaluated by laboratory leaching tests and accelerated loading of full-scale pavement sections under well-controlled conditions. An equivalent of 20 years of highway traffic loading was simulated at the OSU/OU Accelerated Pavement Load Facility (APLF). Three types of portland cement concrete driving surface layers were tested, including a control section (i.e., ordinary portland cement (PC) concrete) containing no fly ash and two sections in which fly ash was substituted for a fraction of the cement; i.e., 30% fly ash (FA30) and 50% fly ash (FA50). In general, the concentrations of minor and trace elements were higher in the toxicity characteristic leaching procedure (TCLP) leachates than in the leachates obtained from synthetic precipitation leaching procedure and ASTM leaching procedures. Importantly, none of the leachate concentrations exceeded the TCLP limits or primary drinking water standards. Surface runoff monitoring results showed the highest release rates of inorganic elements from the FA50 concrete pavement, whereas there were little differences in release rates between PC and FA30 concretes. The release of elements generally decreased with increasing pavement loading. Except for Cr, elements were released as particulates (>0.45 {mu} m) rather than dissolved constituents. The incorporation of fly ash in the PC cement concrete pavements examined in this study resulted in little or no deleterious environmental impact from the leaching of inorganic elements over the lifetime of the pavement system.

01 COAL, LIGNITE, AND PEAT↗

Effect of the Initial Load Parameters on the K-shell Output of Al Planar Wire Arrays Operating in the Microsecond Implosion Regime

A set of microsecond implosion experiments was carried on the GIT-12 generator to study the radiative performance of Al planar wire arrays. The load parameters such as a wire diameter, a gap between the wires, the number of wires, and the total planar wire mass and width were varied during the experiments, however the implosion time and the peak implosion current were almost the same for all load configurations. This ensured equal energy deposition to the plasma due to kinetic mechanisms for all load configurations. Two implosion regimes with the implosion times of 1050 ns and 850 ns were investigated. The experimental data on the K-shell radiation yield and power at varying load parameters are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SHOCKLESS LOADING WITH RECOVERY FOR CHARACTERIZATION OF MATERIAL RESPONSE

A new recovery based method for investigating material response to non-Hugoniot loading paths is described. The work makes use of a laser generated plasma piston that produces ramped loading at high strain rates (> {approx} 10{sup 7}/s). Large sample sizes are utilized to prevent reflected wave interactions. The overall deformation path is characterized by two transients: one at very high strain rate on the 5-10 nanosecond time scale and one at a lower strain rate occurring over a 1-2 microsecond timescale. It was found that a sufficiently large region of material experiences shockless loading conditions such that recovery based characterization is feasible. The presence of two strain transients makes the method more applicable to comparative assessments between shockless and shock loading conditions.

36 MATERIALS SCIENCE↗

Note: A novel method for in situ loading of gases via x-ray induced chemistry

We have developed and demonstrated a novel method to load oxygen in a sealed diamond anvil cell via the x-ray induced decomposition of potassium chlorate. By irradiating a pressurized sample of an oxidizer (KClO{sub 3}) with either monochromatic or white beam x-rays from the Advanced Photon Source at ambient temperature and variable pressure, we succeeded in creating a localized region of molecular oxygen surrounded by unreacted sample which was confirmed via Raman spectroscopy. We anticipate that this technique will be useful in loading even more challenging, difficult-to-load gases such as hydrogen and also to load multiple gases.

08 HYDROGEN↗

Investigation of a high impedance magnetically insulated transmission line oscillator with hollow load

A novel high-impedance magnetically insulated transmission line oscillator (MILO) with greatly restrained power deposition on the anode has been investigated. Methods to increase the MILO impedance and decrease the anode current are discussed. A MILO with impedance of 30 {Omega} and power conversion efficiency of 25% is presented by particle-in-cell simulations. Compared with the previous MILO in our lab, the anode current of the proposed MILO is reduced about 50%, the power conversion efficiency doubles, and the power deposition on anode is reduced nearly one half. Furthermore, considerations for reducing the power deposition on load have also been carried out in MILO design, and the load current is reduced to 4.6 kA, only 17% of the total anode current. Finally, a hollow load was introduced to reduce the power deposition density on the load, without decreasing the power conversion efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the inductance of imploding wire array Z-pinches using measurements of load voltage

The inductance of imploding cylindrical wire array z-pinches has been determined from measurements of load voltage and current. A thorough analysis method is presented that explains how the load voltage of interest is found from raw signals obtained using a resistive voltage divider. This method is applied to voltage data obtained during z-pinch experiments carried out on the MAGPIE facility (1.4 MA, 240 ns rise-time) in order to calculate the load inductance and thereafter the radial trajectory of the effective current sheath during the snowplough implosion. Voltage and current are monitored very close to the load, allowing these calculations to be carried out without the need for circuit modelling. Measurements give a convergence ratio for the current of between 3.1 and 5.7 at stagnation of the pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a cryogenic load frame for the neutron diffractometer at Takumi in Japan Proton Accelerator Research Complex

To prepare for projects such as the Large Hadron Collider upgrade, International Thermonuclear Experimental Reactor and Demonstration reactor, it is important to form a clear understanding of stress-strain properties of the materials that make up superconducting magnets. Thus, we have been studying the mechanical properties of superconducting wires using neutron diffraction measurements. To simulate operational conditions such as temperature, stress, and strain, we developed a cryogenic load frame for stress-strain measurements of materials using a neutron diffractometer at Japan Proton Accelerator Research Complex (J-PARC) Takumi beam line. The maximum load that can be applied to a sample using an external driving machine is 50 kN. Using a Gifford-MacMahon cryocooler, samples can be measured down to temperatures below 10 K when loaded. In the present paper, we describe the details of the cryogenic load frame with its test results by using type-304 stainless steel wire.

43 PARTICLE ACCELERATORS↗

A portable hydro-thermo-mechanical loading cell for in-situ small angle neutron scattering studies of proton exchange membranes

A portable hydro-thermo-mechanical loading cell has been designed to enable in-situ small angle neutron scattering (SANS) studies of proton exchange membranes (PEM) under immersed tensile loadings at different temperatures. The cell consists of three main parts as follows: a letter-paper-size motor-driven mechanical load frame, a SANS friendly reservoir that provides stable immersed and thermal sample conditions, and a data acquisition & control system. The ex-situ tensile tests of Nafion 212 membranes demonstrated a satisfactory thermo-mechanical testing performance of the cell for either dry or immersed conditions at elevated temperatures. The in-situ SANS tensile measurements on the Nafion 212 membranes immersed in D2O at 70oC proved the feasibility and capability of the cell for small angle scattering study on deformation behaviors of PEM and other polymer materials under hydro-thermo-mechanical loading.

hydro-thermo-mechanical.↗

Load responsive multilayer insulation performance testing

Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

42 ENGINEERING↗

Mechanical properties of stanene under uniaxial and biaxial loading: A molecular dynamics study

Stanene, a graphene like two dimensional honeycomb structure of tin has attractive features in electronics application. In this study, we performed molecular dynamics simulations using modified embedded atom method potential to investigate mechanical properties of stanene. We studied the effect of temperature and strain rate on mechanical properties of α-stanene for both uniaxial and biaxial loading conditions. Our study suggests that with the increasing temperature, both the fracture strength and strain of the stanene decrease. Uniaxial loading in zigzag direction shows higher fracture strength and strain compared to the armchair direction, while no noticeable variation in the mechanical properties is observed for biaxial loading. We also found at a higher loading rate, material exhibits higher fracture strength and strain. These results will aid further investigation of stanene as a potential nano-electronics substitute.

36 MATERIALS SCIENCE↗

Cavitation erosion prediction based on analysis of flow dynamics and impact load spectra

Cavitation erosion is the consequence of repeated collapse-induced high pressure-loads on a material surface. The present paper assesses the prediction of impact load spectra of cavitating flows, i.e., the rate and intensity distribution of collapse events based on a detailed analysis of flow dynamics. Data are obtained from a numerical simulation which employs a density-based finite volume method, taking into account the compressibility of both phases, and resolves collapse-induced pressure waves. To determine the spectrum of collapse events in the fluid domain, we detect and quantify the collapse of isolated vapor structures. As reference configuration we consider the expansion of a liquid into a radially divergent gap which exhibits unsteady sheet and cloud cavitation. Analysis of simulation data shows that global cavitation dynamics and dominant flow events are well resolved, even though the spatial resolution is too coarse to resolve individual vapor bubbles. The inviscid flow model recovers increasingly fine-scale vapor structures and collapses with increasing resolution. We demonstrate that frequency and intensity of these collapse events scale with grid resolution. Scaling laws based on two reference lengths are introduced for this purpose. We show that upon applying these laws impact load spectra recorded on experimental and numerical pressure sensors agree with each other. Furthermore, correlation between experimental pitting rates and collapse-event rates is found. Locations of high maximum wall pressures and high densities of collapse events near walls obtained numerically agree well with areas of erosion damage in the experiment. The investigation shows that impact load spectra of cavitating flows can be inferred from flow data that captures the main vapor structures and wave dynamics without the need for resolving all flow scales.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical response of lithium fluoride under off-principal dynamic shock-ramp loading

Single crystal lithium fluoride (LiF), oriented [100], was shock loaded and subsequently shocklessly compressed in two experiments at the Z Machine. We employed velocimetry measurements in order to obtain an impactor velocity, shock transit times, and in-situ particle velocities for LiF samples up to ~1.8 mm thick. We also performed a dual thickness Lagrangian analysis on the in-situ velocimetry data to obtain the mechanical response along the loading path of these experiments. Finally, we observed an elastic response on one experiment during initial shockless compression from 100 GPa before yielding. The relatively large thickness differences utilized for the dual sample analyses (up to ~1.8 mm) combined with a relative timing accuracy of ~0.2 ns resulted in an uncertainty of less than 1% on density and stress at ~200 GPa peak loading on one experiment and <4% on peak loading at ~330 GPa for another. The stress-density analyses from these experiments compare favorably with recent equation of state models for LiF.

36 MATERIALS SCIENCE↗

Detection of an anomalous pressure on a magneto-inertial-fusion load current diagnostic

Recent Magnetized Liner Inertial Fusion experiments at the Sandia National Laboratories Z pulsed power facility have featured a PDV (Photonic Doppler Velocimetry) diagnostic in the final power feed section for measuring load current. In this paper, we report on an anomalous pressure that is detected on this PDV diagnostic very early in time during the current ramp. Early time load currents that are greater than both B-dot upstream current measurements and existing Z machine circuit models by at least 1 MA would be necessary to describe the measured early time velocity of the PDV flyer. This leads us to infer that the pressure producing the early time PDV flyer motion cannot be attributed to the magnetic pressure of the load current but rather to an anomalous pressure. Using the MHD code ALEGRA, we are able to compute a time-dependent anomalous pressure function, which when added to the magnetic pressure of the load current, yields simulated flyer velocities that are in excellent agreement with the PDV measurement. As a result, we also provide plausible explanations for what could be the origin of the anomalous pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of toroidal variation in conducted heat loads in locked mode induced disruptions on DIII-D

Locked mode disruptions with controlled toroidal phase are produced in the DIII-­D tokamak by locking to large non-­axisymmetric applied magnetic perturbations with different toroidal phases. Additionally, the disruption conducted heat loads are found to go almost completely to the outer divertor region, possibly due to strong inner leg detachment, but possibly also due to plasma motion and limiting on the outer divertor leg shelf. The outer leg conducted heat loads are found to have a significant toroidal variation of order ±30%, with a dominantly n = 1 structure. The heat load phase is shifted from initial locked mode phase in a way that is approximately consistent with heat loss into the scrape-­off layer being enhanced at the mode island O-­point outer midplane crossing. These measurements suggest that pre-­existing locked modes can affect the conducted heat load structure during the thermal quench by affecting the thermal quench MHD phase. This is consistent with previous MHD simulations which indicated that pre-­disruption locked mode structures can persist and survive to some degree through the large thermal quench MHD. Finally, this work complements previous work [Shiraki2015] which showed that n = 1 structures in mitigated disruptions can create toroidal variation in the disruption radiated power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗