Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Impaired phloem loading in zmsweet13a,b,c sucrose transporter triple knock‐out mutants in Zea mays

Summary Crop yield depends on efficient allocation of sucrose from leaves to seeds. In Arabidopsis, phloem loading is mediated by a combination of SWEET sucrose effluxers and subsequent uptake by SUT 1/ SUC 2 sucrose/H + symporters. Zm SUT 1 is essential for carbon allocation in maize, but the relative contribution to apoplasmic phloem loading and retrieval of sucrose leaking from the translocation path is not known. Here we analysed the contribution of SWEET s to phloem loading in maize. We identified three leaf‐expressed SWEET sucrose transporters as key components of apoplasmic phloem loading in Zea mays L. Zm SWEET 13 paralogues (a, b, c) are among the most highly expressed genes in the leaf vasculature. Genome‐edited triple knock‐out mutants were severely stunted. Photosynthesis of mutants was impaired and leaves accumulated high levels of soluble sugars and starch. RNA ‐seq revealed profound transcriptional deregulation of genes associated with photosynthesis and carbohydrate metabolism. Genome‐wide association study (GWAS) analyses may indicate that variability in Zm SWEET 13s correlates with agronomical traits, especifically flowering time and leaf angle. This work provides support for cooperation of three Zm SWEET 13s with Zm SUT 1 in phloem loading in Z. mays .

59 BASIC BIOLOGICAL SCIENCES↗

Combining RAVEN, RELAP5-3D, and PHISICS for Fuel Cycle and Core Design Analysis for New Cladding Criteria

The Nuclear Regulatory Commission (NRC) has considered revision of 10 CFR 50.46C rule to account for the effects of burn-up rate in future analysis of reactor accident scenarios so that safety margins may evolve with the operation and reloading of the reactor as dynamic limits. In order to find these limiting conditions, both cladding oxidation and maximum temperature must be cast as functions of fuel exposure. It is computationally intensive to run a plant model through a long duration operational transient to the time of fuel reload, and this must be repeated for each reload until the time of the accident scenario. Moreover, fuel reload patterns may differ in many ways so that calculations with many different core configurations must be considered. To perform such new analyses in a reasonable amount of computational time with good accuracy, Idaho National Laboratory (INL) has developed new multi-physics tools by combining existing codes and adding new capabilities. The Parallel Highly Innovative Simulation INL Code System (PHISICS) toolkit for neutronic and reactor physics is coupled with the Reactor Excursion and Leak Analysis Program (RELAP5-3D) for the Loss of Coolant Accident (LOCA) analysis and RAVEN for the Probabilistic Risk Assessment (PRA) and margin characterization analysis. Expansion of code capability was also necessary. For RELAP5-3D to process a single sequence of cores in a continuous run required modification of RELAP5-3D to restart a sequence of input decks, each with a slightly modified neutronics model or thermal-hydraulic flow region and culminating in an accident scenario. A new multi-deck input processing capability was developed and verified for this analysis. In conclusion, the combined RAVEN/PHISICS/RELAP5-3D tool is used to analyze a typical Pressurized Water Reactor (PWR).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Air-to-Liquid Heat Exchanger Fabricated Using Deposition-Based Additive Manufacturing Processes

Abstract This work describes the use of deposition-based additive manufacturing (AM) techniques to fabricate air-cooled, two-fluid heat exchangers. The project focused on a Heating, Ventilation and Air Conditioning application and used an industry-standard copper/aluminum heat exchanger manufactured with conventional technology as the basis for assessing performance. The manufacturing constraints associated with using deposition-based AM technology for this application include the need for a continuous tool path within each build layer that allows uninterrupted extrusion and therefore defect-free water channel walls that correspond to a reliably leak-tight heat exchanger. A geometry that respects these constraints was developed, simulated, optimized and finally manufactured and tested. The material used was a composite of polymer filled with conductive flakes in order to provide high conductivity in the direction that heat must flow in this heat exchanger, across the wall separating the fluids. The measured performance for several test coupons matched the predicted performance and the test coupons exhibited performance that approach and in some cases exceeds conventional technology

Engineering↗

Large-Eddy Simulation Study of Flow and Combustion Dynamics in a Full-Scale Hydrogen–Air Rotating Detonation Combustor-Stator Integrated System

In the present work, a first-of-its-kind three-dimensional (3D) large-eddy simulation (LES) study is conducted to numerically investigate the combustion dynamics as well as aero-thermal phenomena in a full-scale nonpremixed hydrogen–air rotating detonation engine (RDE) (with a diverging-shaped lower-end wall), when integrated with nozzle guide vanes (NGV) acting as the turbine stator. The wall-modeled LES framework incorporates hydrogen–air detailed chemical kinetics and adaptive mesh refinement (AMR). A comparative analysis is carried out for two operating conditions with different fuel/air mass flow rates but global equivalence ratio of unity, and considering RDE configurations without and with stator. The LES model is validated against available experimental data for the low mass flux condition with respect to detonation wave speed/height, wave dynamics, and axial static pressure distribution. Numerical results indicate significant deflagrative combustion occurring in the fill region near the inner wall due to formation of recirculation zones in the injection near-field driven by the backward facing step. The leading detonation wave is found to be trailed by an azimuthal reflected-shock combustion (ARSC) wave, consistent with experimental observations, which consumes unburned vitiated reactants that leak through the main detonation wave. The main detonation wave characteristics, such as detonation wave speed/height and combustion efficiency, do not change appreciably with the presence of NGV. A novel combustion diagnostic technique based on chemical explosive mode analysis (CEMA) is employed to quantify the fraction of heat release occurring in the detonative mode versus deflagrative mode for the simulated conditions. The exit flow is found to be nearly fully subsonic and supersonic for the low and high mass flux conditions, respectively. Further analysis of the exit flow profiles shows that the presence of NGV renders the flow more axial and significantly impacts the exit Mach number and total pressure, while the total temperature shows negligible change. In addition, the low mass flux operating point, despite exhibiting more deflagrative losses within the combustor, yields overall lower pressure drop from plenum to exhaust, which is mainly attributed to lower pressure drop across the injectors. Lastly, the rotating detonation engine-nozzle guide vanes (RDE-NGV) configuration exhibits higher total pressure loss compared to rotating detonation engine (RDE) without stator across both the mass flux conditions. In conclusion, this study extends the state-of-the-art in numerical modeling of pressure gain combustion (PGC) systems by demonstrating high-fidelity 3D reacting LES of full-scale RDE-NGV systems relevant to RDE-turbine integration for stationary power generation.

Combustion↗

Risk reporting in the Chinese news media in response to radiation threat from the Fukushima nuclear reactor crisis

On March 11, 2011, the northeastern coast of Japan was struck by 9.0-magnitude earthquake that triggered a devastating tsunami. Aside from the huge toll in people's lives and severe damages to property, the tremor sent the Fukushima Daiichi Nuclear Power Plant on a tailspin, causing hydrogen explosions in three reactors, and sending radioactive materials into the air and bodies of water. Declared the largest nuclear disaster since Chernobyl, the crisis threatened neighboring countries, including China (International Business Times, 2011). On March 28, low levels of iodine-131, cesium-137 and strontium, believed to have drifted from Japan, were detected in the air over Heilongjiang province in the northeast part of China and in seawater samples collected in the eastern coastal areas (Qianjiang Eve News, 2011). Because these chemicals can enter the food chain and adversely affect human health (Ifeng.com, 2011), people became understandably anxious and the government had to avert panic. This study asks: How did the Chinese media report the risks attendant to this event? A content analysis of 45 straight news reports published by the Chinese press from March 16, 2011 to April 25, 2011 was conducted. The analysis focused on how the media explained the risk, portrayed potential harm, reported on government actions to safeguard public health, and provided suggestions to reduce public fear. The sources of information cited in the reports were also identified. The articles examined were collected from People.com, a comprehensive online archive of news reports, using 'Fukushima' and 'nuclear radiation' as search terms. The results indicated journalistic practices that left much to be desired in terms of risk reporting. First, the articles explained little about the technical aspects of the radiation leaks and failed to give audiences a general indication of levels of risk. Second, the media over-emphasized the government's position that the environment was safe despite the more rampant word-of-mouth reports to the contrary, a slant that may have done nothing to allay public fear. Third, there was a dearth of information about what the government intends to do to alleviate the situation and suggestions about what people can do to protect themselves. The themes of news reports may be attributed to experts from research institutions and government officials who were the most frequently cited sources of facts, analyses, interpretations, and opinions. Scientists and nuclear experts were cited the most in the news reports. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regulatory Issues Associated with Shipment of Small Quantities of Radioactive Material

Following decertification of the ubiquitous and simple DOT 6M specification package, radioactive materials package Shippers have been faced with the need to use Certified Type B packagings. Many DOE, commercial and academic programs have a need to ship small masses of radioactive material, where the identity of the material or radionuclides is known but the individual activity of some may not be known. For quantities which are small enough to be fissile exempt and have adequate shielding to ensure low radiation levels, these materials could be transported in a package which provides the required containment level. Because their Chalfant type containment vessels meet the ANSI N14.5 definition for leak-tight ( ≤ 1x10 -7 ref cm 3 air/sec), the 9975, 9977, and 9978 are capable of transporting contents requiring the highest standard of containment. The issues associated with certification of a high-integrity, general purpose package for shipping small quantities of such radioactive material are discussed and certification of the packages for this mission is recommended.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DESIGN ISSUES AND QUALIFICATION OF HYDROFORMED DOUBLE WALLED EXPANSION JOINTS IN VACUUM SERVICE

The Vacuum Auxiliary System for ITER is devoted to pumping out, venting, and purging the vacuum volumes of the tokamak. Over 5000 clients including the cryostat and vacuum vessel, at 8500 m3 and 1400 m3 respectively, are serviced by approximately 150 pumping stations through 6 km of pipework. The piping and functions provided to the clients include component operation, routing of potentially tritiated gases, and timely leak localization. Expansion joints are used to reduce loadings on pumps and piping stresses but also to qualify in-line components having low allowable design loads. The ITER project utilizes vacuum valves that are not designed to withstand typical piping system loadings and require detailed design and evaluation. Loading scenarios prescribed by governing system specifications must be considered. To maintain allowable design loads for components and to keep piping stresses below code requirements, double walled hydroformed expansion joints have been employed in the design. These are not standard items and require custom fabrication. Installation space constraints and adjacent pipe support attachment location availability at ITER limit standard expansion joint installation guidelines provided by the Expasion Joint Manufacturers Association (EJMA). Careful consideration must be given to the analysis model to ensure proper function and life expectancy of the component. These considerations include accurate accounting of thrust forces, thermal movements, seismic accelerations, equipment and building differential displacements. In addition to displacements, the process internal, external, and interspace pressures affect the qualification and selection of the double walled expansion joints. The calculation results shall confirm that deflections, forces, and moments are reasonable for the size and type required for the system’s demands as evaluated against the manufacturer’s design.

Clark, Forrest [ORNL] (ORCID:0009000678106843)↗

Beyond hard x-ray photoelectron spectroscopy: Simultaneous combination with x-ray diffraction

Hard x-ray photoelectron spectroscopy (HAXPES) is a powerful and novel emerging technique for the nondestructive determination of electronic properties and chemical composition of bulk, buried interfaces and surfaces. It benefits from the exceptionally large escape depth of high kinetic energy photoelectrons, increasing the information depth up to several tens of nanometers. Complementing HAXPES with an atomic structure sensitive technique (such as x-ray diffraction) opens a new research field with major applications for materials science. At SpLine, the Spanish CRG beamline at the European Synchrotron Radiation Facility, we have developed a novel experimental set-up that combines HAXPES and x-ray diffraction (x-ray reflectivity, surface x-ray diffraction, grazing incidence x-ray diffraction, and reciprocal space maps). Both techniques can be operated simultaneously on the same sample and using the same excitation source. The set-up includes a robust 2S + 3D diffractometer hosting a ultrahigh vacuum chamber equipped with a unique photoelectron spectrometer (few eV < electron kinetic energy < 15 keV), x-ray tube (Mg/Ti), 15 keV electron gun, and auxiliary standard surface facilities (molecular beam epitaxy evaporator, ion gun, low energy electron diffraction, sample heating/cooling system, leak valves, load-lock sample transfer, etc.). This end-station offers the unique possibility of performing simultaneous HAXPES + x-ray diffraction studies. In the present work, we describe the experimental set-up together with two experimental examples that emphasize its outstanding capabilities: (i) nondestructive characterization of the Si/Ge and HfO{sub 2}/SiO{sub 2} interfaces on Ge-based CMOS devices, and (ii) strain study on La{sub 0.7}Ca{sub 0.3}MnO{sub 3} ultrathin films grown on SrTiO{sub 3}(001) substrate.

36 MATERIALS SCIENCE↗

Chamber wall interactions with HBr/Cl{sub 2}/O{sub 2} plasmas

The authors have studied the interaction of HBr/Cl{sub 2}/O{sub 2} inductively coupled plasmas with reactor chamber wall deposits, with and without Si etching, using the “spinning wall” technique. The spinning wall is part of the reactor chamber walls, allowing near-real-time analysis of the composition of surface layers via Auger electron spectrometry and determination of species desorbing off the walls by mass spectrometry. In HBr plasmas with no bias voltage on the Si substrate, and hence no Si etching, HBr is ∼30% dissociated, and H{sub 2} and Br{sub 2} form in the plasma. Layers deposited on the reactor chamber contained little if any Br under these conditions. Adding O{sub 2} to an HBr plasma leads to formation of H{sub 2}O and increased Br{sub 2} (compared to a pure HBr plasma) products that desorb from the spinning wall. H{sub 2}O has a very long residence time on the surface. With bias voltage applied to the Si substrate in an HBr plasma, mass spectrometer signals are prominent for SiBr and SiBr{sub 3}, and weaker for SiBr{sub 2}, SiBr{sub 4}, Si{sub 2}Br{sub 4}, Si{sub 2}Br{sub 5}, and Si{sub 2}OBr{sub 5}. Under these conditions, a SiO{sub x}Br{sub y} layer deposits on the spinning wall. Adding 20% O{sub 2} to HBr stops etching and eliminates Br from the surface layer, indicating that Br on the reactor walls is a result of SiBr{sub x} impingement and not from bromination by impinging Br. With HBr/Cl{sub 2} plasmas and no bias on the stage, a SiO{sub x}Cl{sub y} layer deposits, and no Br is detected. HCl, BrCl, and Br{sub 2} were detected in the line-of-sight leak, around the spinning wall, of a HBr/Cl{sub 2} (1:1) gas mixture in the absence of a plasma. Residence time analysis of species in the chamber and a change in the product distribution with a change in the composition of the layer deposited on the chamber wall suggest that reactions forming these products in the absence of a plasma occur on the reactor walls. With a plasma and bias on the Si substrate, both Br and Cl incorporate in the layer, and a rich spectrum with numerous SiCl{sub x}Br{sub y} peaks was observed up to at least 500 amu. The spectrum does not change with the addition of 6% O{sub 2}. Adding 20% O{sub 2} suppresses Br adsorption, but Cl still adsorbs. In 40% O{sub 2}/HBr/Cl{sub 2} plasmas with stage bias, Cl adsorption also ceases and no etching products are observed in the mass spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Leakage and scatter radiation from a double scattering based proton beamline

Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines at the Loma Linda University Proton Treatment Facility were measured during the acceptance testing that occurred in the early 1990s, recent discussions in the radiotherapy community have prompted a reinvestigation of this contribution to the dose equivalent a patient receives. The dose and dose equivalent delivered to a large phantom patient outside a primary proton field were determined using five methods: simulations using Monte Carlo calculations, measurements with silver halide film, measurements with ionization chambers, measurements with rem meters, and measurements with CR-39 plastic nuclear track detectors. The Monte Carlo dose distribution was calculated in a coronal plane through the simulated patient that coincided with the central axis of the beam. Measurements with the ionization chambers, rem meters, and plastic nuclear track detectors were made at multiple locations within the same coronal plane. Measurements with the film were done in a plane perpendicular to the central axis of the beam and coincident with the surface of the phantom patient. In general, agreement between the five methods was good, but there were some differences. Measurements and simulations also tended to be in agreement with the original acceptance testing measurements and results from similar facilities published in the literature. Simulations illustrated that most of the neutrons entering the patient are produced in the final patient-specific aperture and precollimator just upstream of the aperture, not in the scattering system. These new results confirm that the dose equivalents received by patients outside the primary proton field from primary particles that leak through the nozzle are below the accepted standards for x-ray and electron beams. The total dose equivalent outside of the field is similar to that received by patients undergoing treatments with intensity modulated x-ray therapy. At the center of a patient for a whole course of treatment, the dose equivalent is comparable to that delivered by a single whole-body XCT scan.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-G-BRE-07: Proton Therapy Enhanced by Tumor-Targeting Gold Nanoparticles: A Pilot in Vivo Experiment at The Proton Therapy Center at MD Anderson Cancer Center

Purpose: Assess tumor-growth delay and survival in a mouse model of prostate cancer treated with tumor-targeting gold nanoparticles (AuNPs) and proton therapy. Methods: We first examined the accumulation of targeting nanoparticles within prostate tumors by imaging AuNPs with ultrasound-guided photoacoustics at 24h after the intravenous administration of goserelin-conjugated AuNPs (gAuNP) in three mice. Nanoparticles were also imaged at the cellular level with TEM in PC3 cells incubated with gAuNP for 24h. Pegylated AuNPs (pAuNP) were also imaged in vivo and in vitro for comparison. PC3 cells were then implanted subcutaneously in nude mice; 51mice with 8–10mm tumors were included. AuNPs were injected intravenously at 0.2%w/w final gold concentration 24h before irradiation. A special jig was designed to facilitate tumor irradiation perpendicular to the proton beam. Proton energy was set to 180MeV, the radiation field was 18×18cm{sup 2}, and 9cm or 13.5cm thick solid-water compensators were used to position the tumors at either the beam entrance (BE) or the SOBP. Physical doses of 5Gy were delivered to all tumors on a patient beam line at MD Anderson's Proton Therapy Center. Results: The photoacoustic experiment reveled that our nanoparticles leak from the tumor-feeding vasculature and accumulate within the tumor volume over time. Additionally, TEM images showed gAuNP are internalized in cancer cells, accumulating within the cytoplasm, whereas pAuNP are not. Tumor-growth was delayed by 11 or 32days in mice receiving gAuNP irradiated at the BE or the SOBP, relative to proton radiation alone. Survival curves (ongoing experiment) reveal that gAuNPs improved survival by 36% or 74% for tumors irradiated at the BE or SOBP. Conclusion: These important, albeit preliminary, in vivo findings reveal nanoparticles to be potent sensitizers to proton therapy. Further, conjugation of AuNPs to tumor-specific antigens that promote enhanced cellular internalization improved both tumor-growth delay and survival of mice after proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-C-213-07: Fabrication and Testing of a 3D-Printed Small Animal Rectal Cooling Device to Evaluate Local Hypothermia as a Radioprotector During Prostate SBRT

Purpose: The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to SBRT treatments. Relevant to prostate SBRT, this work details the fabrication and testing of a 3D-printed cooling device to facilitate the investigation of the radioprotective effect of local hypothermia on the rat rectum. Methods: A 3cm long, two-channel rectal cooling device was designed in SOLIDWORKS CAD for 3D printing. The water intake nozzle is connected to a 1mm diameter brass pipe from which water flows and circulates back around to the exit nozzle. Both nozzles are connected by plastic tubing to a water chiller pump. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within a rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. CBCT images from a small-animal irradiator were evaluated for imaging artifacts which could affect Monte Carlo dose calculations during treatment planning. Results: The rectal temperature adjacent to the cooling device decreased from body temperature (37°C) to 15°C in 10–20 minutes from device insertion. Rectal temperature was maintained at 15±3°C during active cooling. MRI thermometry tests revealed a steep temperature gradient with increasing distance from the cooling device, with the desired temperature range maintained within the surrounding few millimeters. Conclusion: A 3D printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in rat rectums. Rectal cooling capabilities were characterized in-vivo to facilitate an investigation of the radioprotective effect of hypothermia for late rectal toxicity following a single large dose of radiation. Funding support provided by RSNA research seed grant.

60 APPLIED LIFE SCIENCES↗

SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-04: Radiation Heat Load On the MR System of the Elekta Atlantic System

Purpose: The Elekta Atlantic system combines a digital linear accelerator system with a 1.5T Philips MRI machine.This study aimed to assess the energy deposited within the cryostat system when the radiation beam passes through the cryostat. The cryocooler on the magnet has a cooling capacity which is about 1 Watt in excess of the cryogenic heat leak into the magnet’s cold mass. A pressure-controlled heater inside the magnet balances the excess refrigeration power such that the helium pressure in the tank is kept slightly above ambient air pressure. If radiation power is deposited in the cold mass then this heater will need less power to maintain pressure equilibrium and if the radiation heat load exceeds the excess cryocooler capacity the pressure will rise. Methods: An in-house CAD based Monte Carlo code based on Penelope was used to model the entire MR-Linac system to quantify the heat load on the magnet’s cold mass. These results were then compared to experimental results obtained from an Elekta Atlantic system installed in UMC-Utrecht. Results: For a field size of 25 cm x 22 cm and a dose rate of 107 mu.min-1, the energy deposited by the radiation beam led to a reduction in heater power from 1.16 to 0.73 W. Simulations predicted a reduction to 0.69 W which is in good agreement. For the worst case field size (largest) and maximum dose rate the cryostat cooler capacity was exceeded. This resulted in a pressure rise within the system but was such that continuous irradiation for over 12 hours would be required before the magnet would start blowing off helium. Conclusion: The study concluded that the Atlantic system does not have to be duty cycle restricted, even for the worst case non-clinical scenario and that there are no adverse effects on the MR system. Stephen Towe and David Roberts Both work for Elekta; Ezra Van Lanen works for Philips Healthcare; Johan Overweg works for Philips Innovative Technologies.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-01: Can EPID Based Measurement Replace Traditional Daily Output QA On Megavoltage Linac?

Purpose: To investigate the long term stability and viability of using EPID-based daily output QA via in-house and vendor driven protocol, to replace conventional QA tools and improve QA efficiency. Methods: Two Varian TrueBeam machines (TB1&TB2) equipped with electronic portal imaging devices (EPID) were employed in this study. Both machines were calibrated per TG-51 and used clinically since Oct 2014. Daily output measurement for 6/15 MV beams were obtained using SunNuclear DailyQA3 device as part of morning QA. In addition, in-house protocol was implemented for EPID output measurement (10×10 cm fields, 100 MU, 100cm SID, output defined over an ROI of 2×2 cm around central axis). Moreover, the Varian Machine Performance Check (MPC) was used on both machines to measure machine output. The EPID and DailyQA3 based measurements of the relative machine output were compared and cross-correlated with monthly machine output as measured by an A12 Exradin 0.65cc Ion Chamber (IC) serving as ground truth. The results were correlated using Pearson test. Results: The correlations among DailyQA3, in-house EPID and Varian MPC output measurements, with the IC for 6/15 MV were similar for TB1 (0.83–0.95) and TB2 (0.55–0.67). The machine output for the 6/15MV beams on both machines showed a similar trend, namely an increase over time as indicated by all measurements, requiring a machine recalibration after 6 months. This drift is due to a known issue with pressurized monitor chamber which tends to leak over time. MPC failed occasionally but passed when repeated. Conclusion: The results indicate that the use of EPID for daily output measurements has the potential to become a viable and efficient tool for daily routine LINAC QA, thus eliminating weather (T,P) and human setup variability and increasing efficiency of the QA process.

60 APPLIED LIFE SCIENCES↗

TU-H-206-02: Novel Linearly-Filled Derenzo PET Phantom Design

Purpose: To design a linearly-filled Derenzo positron emission tomography (PET) phantom, eliminating the extraneous radioisotope volumes in a conventional reservoir-type design. This activity reduction combined with the elimination of bubbles in smaller phantom channels would significantly reduce personnel dose, radioisotope cost, and would improve image quality by reducing out-of-slice activity scatter. Methods: A computer-aided design (CAD) was created of a modular Derenzo phantom consisting of three phantom layers with gaskets between the layers. The central piece contains the active pattern volume and channels connecting adjacent rods in a serpentine pattern. The two end-pieces contained an inlet and an outlet for filling purposes. Phantom prototypes were 3D printed on a Viper Si2 stereolithography machine. The two gaskets were fabricated from silicon sheets using a PLS 6.75 laser cutter. Phantoms were held together by pass-through glass-filled nylon bolts and nuts. Phantoms were filled with {sup 52}Mn, {sup 64}Cu, {sup 74}Br, and {sup 124}I for testing, and were imaged on a Siemens Inveon MicroPET scanner. Results: Four phantom prototypes were constructed using male Leur Lock fittings for inlet/outlet ports. 3D printed layers were sanded to ensure proper coupling to the silicon gaskets. The filling volume for each prototype was approximately 2.4 mL. The filling process was found to be rapid, leak-tight, and with minimal back-pressure. PET images were reconstructed by OSEM3D, and axial slices along the phantom pattern length were averaged to provide final images. Image distortion was isotope dependent with {sup 52}Mn and {sup 64}Cu having the least distortion and {sup 124}I having the most distortion. Conclusion: These results indicate that the linearlyfilled Derenzo design improves on conventional reservoir-type designs by eliminating potential bubbles in small channels and by reducing activity level, radioisotope volume, radioisotope cost, personnel dose, filling time, and out-of-slice activity scatter The method described in this abstract has been filed as a patent application to the US Patent and Trade Office by the Wisconsin Alumni Research Foundation (WARF).

60 APPLIED LIFE SCIENCES↗

Investigating the Unique Ability of Trichodesmium To Fix Carbon and Nitrogen Simultaneously Using MiMoSA

The open ocean is an extremely competitive environment, partially due to the dearth of nutrients. Trichodesmium erythraeum, a marine diazotrophic cyanobacterium, is a keystone species in the ocean due to its ability to fix nitrogen and leak 30 to 50% into the surrounding environment, providing a valuable source of a necessary macronutrient to other species. While there are other diazotrophic cyanobacteria that play an important role in the marine nitrogen cycle, Trichodesmium is unique in its ability to fix both carbon and nitrogen simultaneously during the day without the use of specialized cells called heterocysts to protect nitrogenase from oxygen. Here, we use the advanced modeling framework called multiscale multiobjective systems analysis (MiMoSA) to investigate how Trichodesmium erythraeum can reduce dimolecular nitrogen to ammonium in the presence of oxygen. Our simulations indicate that nitrogenase inhibition is best modeled as Michealis-Menten competitive inhibition and that cells along the filament maintain microaerobia using high flux through Mehler reactions in order to protect nitrogenase from oxygen. We also examined the effect of location on metabolic flux and found that cells at the end of filaments operate in distinctly different metabolic modes than internal cells despite both operating in a photoautotrophic mode. These results give us important insight into how this species is able to operate photosynthesis and nitrogen fixation simultaneously, giving it a distinct advantage over other diazotrophic cyanobacteria because they can harvest light directly to fuel the energy demand of nitrogen fixation.

09 BIOMASS FUELS↗