Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hybrids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

A Near Ideal Edge Termination Technique for 4500V 4H-SiC Devices: The Hybrid Junction Termination Extension

This letter presents a new edge termination technique named a hybrid junction termination extension (Hybrid-JTE), which combines ring-assisted JTE and multiple floating zone JTE. Based on the parameters of the drift layer specified by the wafer vendor, the measured breakdown voltage of the fabricated p-i-n diode using the Hybrid-JTE is as high as 5450 V, which is close (~99%) of the ideal parallel plane p-n junction. As a result, measured breakdown voltages from randomly chosen 32 p-i-n diodes across the wafer show very tight distribution: 29 diodes provide breakdown voltages higher than 5000 V at 100 μA.

42 ENGINEERING↗

Hybrid Modeling of Three-Phase Grid-Supporting Inverters for Dynamic Studies

Grid technologies connected by power electronic converter (PEC) interfaces continually implement grid support functions mandated by grid codes and standards. The transition to converter-based generation demands precise PEC models to assess system dynamics, which have been previously overlooked in conventional power systems. This study proposes a hybrid method for analyzing grid-connected three-phase PEC dynamics with the IEEE standard 1547-2018 Volt-VAr mode that combines physics and data-driven techniques. The physics model reflects the PEC’s internal behavior, whereas the data-driven modeling technique evaluates the grid-supporting capabilities of the smart PEC. The system identification approach is used to generate dynamic PEC models based on changing grid voltage and measured current injected into the grid by the PEC. In the Volt-VAr support mode, a detailed topological model including switches is utilized to compare the goodness-of-fit of the extracted hybrid dynamic model. The results demonstrate that the hybrid PEC model in the Volt-VAr mode accurately matches the dynamics with the topological model.

Subedi, Sunil↗

Hybrid Quantum-Classical Neural Networks

Deep learning is one of the most successful and far-reaching strategies used in machine learning today. However, the scale and utility of neural networks is still greatly limited by the current hardware used to train them. These concerns have become increasingly pressing as conventional computers are soon expected to approach the physical limitations that will slow their performance improvements in the near future. For these reasons, scientists have begun to explore alternative computing platforms, like quantum computers, for training neural networks. In recent years, variational quantum circuits have emerged as one of the most successful approaches to quantum deep learning on noisy intermediate scale quantum devices. We propose a hybrid quantum-classical neural network architecture where each neuron is a variational quantum circuit. We empirically analyze the performance of this hybrid neural network on a series of binary classification data sets using a simulated IBM universal quantum computer and a state-of-the-art IBM universal quantum computer. On the simulated hardware, we observe that the hybrid neural network achieves around 10% higher classification accuracy and 20% better minimization of the cost function than an individual variational quantum circuit. On the quantum hardware, we observe that each model only performs well when the qubit and gate count is sufficiently small.

Arthur, Davis↗

A New Hybrid Quantum-Classical Algorithm for Solving the Unit Commitment Problem

Solving problems related to planning and operations of large-scale power systems is challenging on classical computers due to their inherent nature as mixed-integer and nonlinear problems. Quantum computing provides new avenues to approach these problems. We develop a hybrid quantum-classical algorithm for the Unit Commitment (UC) problem in power systems which aims at minimizing the total cost while optimally allocating generating units to meet the hourly demand of the power loads. The hybrid algorithm combines a variational quantum algorithm (VQA) with a classical Benders-type heuristic. The resulting algorithm computes approximate solutions to UC in three stages: i) a collection of UC vectors capable meeting the power demand with lowest possible operating costs is generated based on VQA; ii) a classical sequential least squares programming (SLSQP) routine is leveraged to find the optimal power level corresponding to a predetermined number of candidate vectors; iii) in the last stage, the approximate solution of UC along with generating units power level combination is given. To demonstrate the effectiveness of the presented method, three different systems with 3 generating units, 10 generating units, and 26 generating units were tested for different time periods. In addition, convergence of the hybrid quantum-classical algorithm for select time periods is proven out on IonQ's Forte system.

Aboumrad, Willie [IonQ, Inc]↗

FEM Analysis of Hybrid LTS/HTS Cos-Theta Dipole Magnet With Heterogeneous Cable Model

The Lawrence Berkeley National Laboratory (LBNL) and the National High Magnetic Field Laboratory (NHMFL) have published results on Bi-2212 superconductive magnets realized and tested in the canted cosine-theta and solenoid designs, respectively. Fermilab is now preparing for the assembly of the first Bi-2212 stress-managed cosine-theta insert magnet. The insert will be part of the first hybrid cosine-theta magnet made of Nb$_3$Sn outer layers within the US-MDP effort to reach a 20 T bore field. This paper presents the analytical analysis of the cosine-theta Nb$_3$Sn/Bi-2212 hybrid magnet. We report the parameters, logic, and implementation method of the 2D electromagnetic and mechanical FEM analysis of the LTS/HTS hybrid magnet. Results from a detailed heterogeneous model are compared to the homogeneous model implemented in the past. A Python code has been developed to simulate the current degradation due to stresses in the detail-modeled conductor areas. The current degradation has been introduced in the simulation dynamics for the HTS conductor as an iteration process, updating the input load of Lorentz forces of the energization at each step. The magnetic and mechanical analysis results of the 2D cosine-theta LTS/HTS dipole magnet have been described and analyzed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Hybrid Method to Estimate Specific Differential Phase and Rainfall With Linear Programming and Physics Constraints

A hybrid method of combining linear programming (LP) and physical constraints is developed to estimate specific differential phase (K DP ) and to improve rain estimation. Moreover, the hybrid K DP estimator and the existing estimators of LP, least squares fitting, and a self-consistent relation of polarimetric radar variables are evaluated and compared using simulated data. Our simulation results indicate the new estimator's superiority, particularly in regions where backscattering phase (δ hv ) dominates. Further, a quantitative comparison between auto-weather-station rain-gauge observations and K DP -based radar rain estimates for a Meiyu event also demonstrate the superiority of the hybrid K DP estimator over existing methods.

54 ENVIRONMENTAL SCIENCES↗

Grid Forming Control Tuning for a Hybrid Inverter-Based Resource Power Plant

A hybrid inverter-based resource (IBR) power plant consists of grid-following (GFL) and grid-forming inverter-based resources (GFM-IBR) connected in parallel. Here, this research focuses on how to design and tune GFM's control parameters to ensure stable operation of the hybrid power plant for weak and strong grid conditions. We consider two design cases: one where the GFL-IBR does not provide frequency support, and one where it does. It is found that the GFM's power-frequency synchronizing system can lose stability when the power-frequency droop constant is large and/or the grid is strong. Additionally, if the GFL has its frequency support enabled, oscillation stability worsens. To explain the mechanism of the interactions, we construct a feedback system for the synchronizing loop, which consists of the GFM's power-frequency droop control that generates the GFM's synchronizing angle, the GFL's phase-locked loop that measures the voltage phase angle, the GFL's frequency-power control that generates its power order, and the rest of the system. The feedback system is effective in illustrating the potential stability risks. Successful design ensures that the hybrid power plant can operate smoothly and ride through grid disturbances.

feedback systems↗

Radiation capture and conversion efficiencies of Miscanthus sacchariflorus , M. sinensis and their naturally occurring hybrid M . × giganteus

Abstract Miscanthus is a rhizomatous C4 grass of great interest as a biofuel crop because it has the potential to produce high yields over a wide geographical area with low agricultural inputs on marginal land less suitable for food production. At the moment, a clonal interspecific hybrid Miscanthus × giganteus is the most widely cultivated and studied in Europe and the United States, but breeding programmes are developing newer more productive varieties. Here, we quantified the physiological processes relating to whole season yield in a replicated plot trial in Wales, UK . Light capture and conversion efficiency were parameterized for four carefully selected genotypes ( M. sinensis , M. sacchariflorus and Miscanthus × giganteus ). Differences in the canopy architecture in mature stands as measured by the extinction coefficient ( k ) were small (0.55–0.65). Sensitivity analysis on a mathematical model of Miscanthus was performed to quantify the accumulative intercepted photosynthetically active radiation ( iPAR ) in the growing season using (i) k, (ii) variation in the thermal responses of leaf expansion rate, (iii) base temperature for degree days and (iv) date start of canopy expansion. A 10% increase in k or leaf area per degree day both had a minimal effect on iPAR (3%). Decreasing base temperature from 10 to 9 °C gave an 8% increase in iPAR . If the starting date for canopy expansion was the same as shoot emergence date, then the iPAR increases by 12.5%. In M . × giganteus, the whole season above ground and total (including below ground) radiation‐use efficiency ( RUE ) ranged from 45% to 37% higher than the noninterspecific hybrid genotypes. The greater yields in the interspecific hybrid M. × giganteus are explained by the higher RUE and not by differences in iPAR or partitioning effects. Studying the mechanisms underlying this complex trait could have wide benefits for both fuel and food production.

Davey, Christopher Lyndon↗

In situ embryo rescue for generation of wide intra‐ and interspecific hybrids of Panicum virgatum L.

Summary Wide crosses have been used for decades as a method for transferring novel genetic material and traits in plant breeding. Historically, many products of wide crosses require tedious and inefficient surgical embryo rescue prior to embryo abortion to recover single plantlets. We have utilized transgenic switchgrass ( Panicum virgatum L. cv Alamo) as a pollen donor in conjunction with antibiotic or herbicide selection for recovery of intra‐and interspecific F 1 crosses by using developing ovules from the female parent and selecting for embryogenic cultures derived from the in situ immature embryo. Using this approach, several intravarietial crosses were generated between transgenic Alamo and the switchgrass varieties Kanlow, Blackwell and Cave ‐ in ‐ Rock as well as an interspecific cross with Atlantic coastal panicgrass. This procedure selected F 1 embryogenic callus produced from the developing embryo contained within isolated immature ovules. Several clonal plants were successfully regenerated from each cross. Southern blot, PCR , phenotypic analyses and genomic analysis confirmed F 1 hybrids. Using genotyping‐by‐sequencing shows the hybridization of the recovered plants by determining the ratio of transgressive markers to total compared markers between parents and their potential offspring. The ratio of transgressive markers to total compared markers was significantly lower between parents and their predicted offspring than between parents and offspring unrelated to them. This approach provides the possibility to move useful transgenes into varieties that are recalcitrant to direct transformation which can be optionally segregated thus useful to create new hybrids, as well as recovery of wide crosses that are either difficult or impossible using traditional techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Hybrid-Electric Turbocharger and High-Speed SiC Variable-Frequency Drive Using Sensorless Control Algorithm

Electrically assisted engine boosting systems lend themselves to better throttle response, wider effective operating ranges, and can provide the ability to extract excess energy during deceleration and high-load events (and store it in a vehicle's onboard batteries). This can lead to better overall vehicle performance, emissions, and efficiency while allowing for further engine downsizing and increased power density. In this research effort, a hybrid-electric turbocharger, variable-frequency drive (VFD), and novel sensorless control algorithm were developed. An 11 kW permanent-magnet (PM) machine was coupled to a commercial turbocharger via an in-line, bolt-on housing attached to the compressor inlet. A high-efficiency, high-temperature VFD, consisting of custom control and power electronics, was also developed. The VFD uses SiC MOSFETS to achieve high-switching frequency and can be cooled using an existing engine coolant loop operating at up to 105 °C at an efficiency greater than 98%. A digital sliding mode-observer sensorless speed control algorithm was created to command and regulate speed and achieved ramp rates of over 68,000 rpm/s. A two-machine benchtop motor/generator test stand was constructed for initial testing and tuning of the VFD and sensorless control algorithm. A gas blow-down test stand was constructed to test the mechanical operation of the hybrid-electric turbocharger and speed control using the VFD. In addition, a liquid-pump cart was assembled for high-temperature testing of the VFD. Initial on-engine testing is planned for later this year. This paper intends to present a design overview of the in-line, hybrid-electric device, VFD, and performance characterization of the electronics and sensorless control algorithm.

Engineering↗

Energy demand reduction in the built environment using shallow geothermal integrated energy systems: Part II – Hybrid ground source heat pump for building heating

The research collection aims at finding the various possible opportunities for the effective integration of shallow geothermal energy (SGE) to decrease the energy demand in the built environment and to reduce emission associated with it. The direct utilization of SGE using a ground source heat pump (GSHP) has been reviewed in comprehensive review part I and part II. From the extensive review, we have found that the hybrid GSHP is needed to avoid ground thermal imbalance and peak demand. Hybrid GSHP can adopt various supplemental heat sources and sinks according to the local climatic conditions and the balance of energy demands. The primary focus on the integration of subsystems such as biomass, solar energy (PV, PVT, and collector), phase change material, micro gas turbine, and absorption heat pump with GSHP is presented for heating application. This comprehensive review part III highlights the recent research findings and a potential gap in hybrid GSHP for further research and developments

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hybrid approach for rapid, accurate, and direct kilovoltage radiation dose calculations in CT voxel space

Purpose: To develop and validate a fast and accurate method that uses computed tomography (CT) voxel data to estimate absorbed radiation dose at a point of interest (POI) or series of POIs from a kilovoltage (kV) imaging procedure. Methods: The authors developed an approach that computes absorbed radiation dose at a POI by numerically evaluating the linear Boltzmann transport equation (LBTE) using a combination of deterministic and Monte Carlo (MC) techniques. This hybrid approach accounts for material heterogeneity with a level of accuracy comparable to the general MC algorithms. Also, the dose at a POI is computed within seconds using the Intel Core i7 CPU 920 2.67 GHz quad core architecture, and the calculations are performed using CT voxel data, making it flexible and feasible for clinical applications. To validate the method, the authors constructed and acquired a CT scan of a heterogeneous block phantom consisting of a succession of slab densities: Tissue (1.29 cm), bone (2.42 cm), lung (4.84 cm), bone (1.37 cm), and tissue (4.84 cm). Using the hybrid transport method, the authors computed the absorbed doses at a set of points along the central axis and x direction of the phantom for an isotropic 125 kVp photon spectral point source located along the central axis 92.7 cm above the phantom surface. The accuracy of the results was compared to those computed with MCNP, which was cross-validated with EGSnrc, and served as the benchmark for validation. Results: The error in the depth dose ranged from -1.45% to +1.39% with a mean and standard deviation of -0.12% and 0.66%, respectively. The error in the x profile ranged from -1.3% to +0.9%, with standard deviations of -0.3% and 0.5%, respectively. The number of photons required to achieve these results was 1x10{sup 6}. Conclusions: The voxel-based hybrid method evaluates the LBTE rapidly and accurately to estimate the absorbed x-ray dose at any POI or series of POIs from a kV imaging procedure.

60 APPLIED LIFE SCIENCES↗

FusionArc optimization: A hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy

Purpose: To introduce a hybrid volumetric modulated arc therapy/intensity modulated radiation therapy (VMAT/IMRT) optimization strategy called FusionArc that combines the delivery efficiency of single-arc VMAT with the potentially desirable intensity modulation possible with IMRT.Methods: A beamlet-based inverse planning system was enhanced to combine the advantages of VMAT and IMRT into one comprehensive technique. In the hybrid strategy, baseline single-arc VMAT plans are optimized and then the current cost function gradients with respect to the beamlets are used to define a metric for predicting which beam angles would benefit from further intensity modulation. Beams with the highest metric values (called the gradient factor) are converted from VMAT apertures to IMRT fluence, and the optimization proceeds with the mixed variable set until convergence or until additional beams are selected for conversion. One phantom and two clinical cases were used to validate the gradient factor and characterize the FusionArc strategy. Comparisons were made between standard IMRT, single-arc VMAT, and FusionArc plans with one to five IMRT/hybrid beams.Results: The gradient factor was found to be highly predictive of the VMAT angles that would benefit plan quality the most from beam modulation. Over the three cases studied, a FusionArc plan with three converted beams achieved superior dosimetric quality with reductions in final cost ranging from 26.4% to 48.1% compared to single-arc VMAT. Additionally, the three beam FusionArc plans required 22.4%-43.7% fewer MU/Gy than a seven beam IMRT plan. While the FusionArc plans with five converted beams offer larger reductions in final cost-32.9%-55.2% compared to single-arc VMAT-the decrease in MU/Gy compared to IMRT was noticeably smaller at 12.2%-18.5%, when compared to IMRT.Conclusions: A hybrid VMAT/IMRT strategy was implemented to find a high quality compromise between gantry-angle and intensity-based degrees of freedom. This optimization method will allow patients to be simultaneously planned for dosimetric quality and delivery efficiency without switching between delivery techniques. Example phantom and clinical cases suggest that the conversion of only three VMAT segments to modulated beams may result in a good combination of quality and efficiency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique

Purpose: Active matrix flat-panel imagers (AMFPIs) incorporating thick, segmented scintillators have demonstrated order-of-magnitude improvements in detective quantum efficiency (DQE) at radiotherapy energies compared to systems based on conventional phosphor screens. Such improved DQE values facilitate megavoltage cone-beam CT (MV CBCT) imaging at clinically practical doses. However, the MV CBCT performance of such AMFPIs is highly dependent on the design parameters of the scintillators. In this paper, optimization of the design of segmented scintillators was explored using a hybrid modeling technique which encompasses both radiation and optical effects. Methods: Imaging performance in terms of the contrast-to-noise ratio (CNR) and spatial resolution of various hypothetical scintillator designs was examined through a hybrid technique involving Monte Carlo simulation of radiation transport in combination with simulation of optical gain distributions and optical point spread functions. The optical simulations employed optical parameters extracted from a best fit to measurement results reported in a previous investigation of a 1.13 cm thick, 1016μm pitch prototype BGO segmented scintillator. All hypothetical designs employed BGO material with a thickness and element-to-element pitch ranging from 0.5 to 6 cm and from 0.508 to 1.524 mm, respectively. In the CNR study, for each design, full tomographic scans of a contrast phantom incorporating various soft-tissue inserts were simulated at a total dose of 4 cGy. Results: Theoretical values for contrast, noise, and CNR were found to be in close agreement with empirical results from the BGO prototype, strongly supporting the validity of the modeling technique. CNR and spatial resolution for the various scintillator designs demonstrate complex behavior as scintillator thickness and element pitch are varied—with a clear trade-off between these two imaging metrics up to a thickness of ∼3 cm. Based on these results, an optimization map indicating the regions of design that provide a balance between these metrics was obtained. The map shows that, for a given set of optical parameters, scintillator thickness and pixel pitch can be judiciously chosen to maximize performance without resorting to thicker, more costly scintillators. Conclusions: Modeling radiation and optical effects in thick, segmented scintillators through use of a hybrid technique can provide a practical way to gain insight as to how to optimize the performance of such devices in radiotherapy imaging. Assisted by such modeling, the development of practical designs should greatly facilitate low-dose, soft tissue visualization employing MV CBCT imaging in external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-P-06: A Novel Hybrid Planning Approach to Allow More Patients Benefited by the Intensity Modulated Proton Therapy

Purpose: We report a hybrid scattering and scanning beam delivery approach, termed as (HimpsPT), which demonstrated that majority IMPT delivery can be potentially replaced with hybrid IMPT and PSPT delivery with similar or better plan quality. Methods: Three representative clinical cases, including head and neck (HN), skull base chordoma (CNS) and lung cancer, treated in MDACC Proton Therapy Center with IMPT were retrospectively redesigned using HimpsPT. The PSPT plans are designed with the same prescriptions as those of IMPT plans. The whole treatment can be delivered by either alternating or sequential PSPT and IMPT delivery. The dosimetric data and dose distributions of HimpsPT plans are compared with those of IMPT plans. We also performed a worst-case robust analysis for all plans. Results: The target coverages for all cases are comparable. For the HN case, the mean dose of esophagus larynx, left parotid and right submandibular, oral cavity V20, the max dose of cord is 18.0, 36.1, 23.6, 47.2, 0.1, 31.7 Gy in HimpsPT plan, and 25.5, 33.8, 24.9, 49.1, 0.2, 33.8 Gy in IMPT plan. For the lung case, the lung V5, V20, V30, mean lung dose, heart V40, esophagus V70, cord maximum dose are 50.5%, 37.0%, 31.7%, 21.3 Gy, 7.2%, 4.9%, 35.5 Gy in HimpsPT plan, and 55.4%, 36.7%, 30.1%, 21.3 Gy, 7.7%, 8.4%, 36.8Gy in IMPT plans. For the CNS case, brainstem maximum dose is 50.5 Gy in HimpsPT plan and 55.4 Gy in IMPT plan due to sharp penumbra offered by the aperture of the PSPT plan in HimpsPT technique. Conclusion: For majority disease sites, the dosimetric advantage of IMPT technique can be achieved by the hybrid PSPT and IMPT technique, which enables the centers equipped with both scattering and scanning beam facilities to treat more patients which can be benefited by the scanning beam.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-I-02: Estimation of the Dosimetric Error Caused by the Voxelization of Hybrid Computational Phantoms Using Triangle Mesh-Based Monte Carlo Transport

Purpose: Computational voxel phantom provides realistic anatomy but the voxel structure may result in dosimetric error compared to real anatomy composed of perfect surface. We analyzed the dosimetric error caused from the voxel structure in hybrid computational phantoms by comparing the voxel-based doses at different resolutions with triangle mesh-based doses. Methods: We incorporated the existing adult male UF/NCI hybrid phantom in mesh format into a Monte Carlo transport code, penMesh that supports triangle meshes. We calculated energy deposition to selected organs of interest for parallel photon beams with three mono energies (0.1, 1, and 10 MeV) in antero-posterior geometry. We also calculated organ energy deposition using three voxel phantoms with different voxel resolutions (1, 5, and 10 mm) using MCNPX2.7. Results: Comparison of organ energy deposition between the two methods showed that agreement overall improved for higher voxel resolution, but for many organs the differences were small. Difference in the energy deposition for 1 MeV, for example, decreased from 11.5% to 1.7% in muscle but only from 0.6% to 0.3% in liver as voxel resolution increased from 10 mm to 1 mm. The differences were smaller at higher energies. The number of photon histories processed per second in voxels were 6.4×10{sup 4}, 3.3×10{sup 4}, and 1.3×10{sup 4}, for 10, 5, and 1 mm resolutions at 10 MeV, respectively, while meshes ran at 4.0×10{sup 4} histories/sec. Conclusion: The combination of hybrid mesh phantom and penMesh was proved to be accurate and of similar speed compared to the voxel phantom and MCNPX. The lowest voxel resolution caused a maximum dosimetric error of 12.6% at 0.1 MeV and 6.8% at 10 MeV but the error was insignificant in some organs. We will apply the tool to calculate dose to very thin layer tissues (e.g., radiosensitive layer in gastro intestines) which cannot be modeled by voxel phantoms.

60 APPLIED LIFE SCIENCES↗

Hybrid detection of lung nodules on CT scan images

Purpose: The diversity of lung nodules poses difficulty for the current computer-aided diagnostic (CAD) schemes for lung nodule detection on computed tomography (CT) scan images, especially in large-scale CT screening studies. We proposed a novel CAD scheme based on a hybrid method to address the challenges of detection in diverse lung nodules. Methods: The hybrid method proposed in this paper integrates several existing and widely used algorithms in the field of nodule detection, including morphological operation, dot-enhancement based on Hessian matrix, fuzzy connectedness segmentation, local density maximum algorithm, geodesic distance map, and regression tree classification. All of the adopted algorithms were organized into tree structures with multi-nodes. Each node in the tree structure aimed to deal with one type of lung nodule. Results: The method has been evaluated on 294 CT scans from the Lung Image Database Consortium (LIDC) dataset. The CT scans were randomly divided into two independent subsets: a training set (196 scans) and a test set (98 scans). In total, the 294 CT scans contained 631 lung nodules, which were annotated by at least two radiologists participating in the LIDC project. The sensitivity and false positive per scan for the training set were 87% and 2.61%. The sensitivity and false positive per scan for the testing set were 85.2% and 3.13%. Conclusions: The proposed hybrid method yielded high performance on the evaluation dataset and exhibits advantages over existing CAD schemes. We believe that the present method would be useful for a wide variety of CT imaging protocols used in both routine diagnosis and screening studies.

60 APPLIED LIFE SCIENCES↗

SU-F-J-58: Evaluation of RayStation Hybrid Deformable Image Registration for Accurate Contour Propagation in Adaptive Planning

Purpose: Adaptive radiotherapy requires complete new sets of regions of interests (ROIs) delineation on the mid-treatment CT images. This work aims at evaluating the accuracy of the RayStation hybrid deformable image registration (DIR) algorithm for its overall integrity and accuracy in contour propagation for adaptive planning. Methods: The hybrid DIR is based on the combination of intensity-based algorithm and anatomical information provided by contours. Patients who received mid-treatment CT scans were identified for the study, including six lung patients (two mid-treatment CTs) and six head-and-neck (HN) patients (one mid-treatment CT). DIRpropagated ROIs were compared with physician-drawn ROIs for 8 ITVs and 7 critical organs (lungs, heart, esophagus, and etc.) for the lung patients, as well as 14 GTVs and 20 critical organs (mandible, eyes, parotids, and etc.) for the HN patients. Volume difference, center of mass (COM) difference, and Dice index were used for evaluation. Clinical-relevance of each propagated ROI was scored by two physicians, and correlated with the Dice index. Results: For critical organs, good agreement (Dice>0.9) were seen on all 7 for lung patients and 13 out of 20 for HN patients, with the rest requiring minimal edits. For targets, COM differences were within 5 mm on average for all patients. For Lung, 5 out of 8 ITVs required minimal edits (Dice 0.8–0.9), with the rest 2 needed re-drawn due to their small volumes (<10 cc). However, the propagated HN GTVs resulted in relatively low Dice values (0.5–0.8) due to their small volumes (3–40 cc) and high variability, among which 2 required re-drawn due to new nodal target identified on the mid-treatment CT scans. Conclusion: The hybrid DIR algorithm was found to be clinically useful and efficient for lung and HN patients, especially for propagated critical organ ROIs. It has potential to significantly improve the workflow in adaptive planning.

60 APPLIED LIFE SCIENCES↗