Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Development of a Residential Integrated Ventilation Controller

The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20%, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

30 DIRECT ENERGY CONVERSION↗

Secure Control Systems for the Energy Sector

Schweitzer Engineering Laboratories (SEL) will conduct the Hallmark Project to address the need to reduce the risk of energy disruptions because of cyber incidents on control systems. The goals is to develop solutions that can be both applied to existing control systems and designed into new control systems to add the security measures needed to mitigate energy network vulnerabilities. The scope of the Hallmark Project contains four primary elements: 1. Technology transfer of the Secure Supervisory Control and Data Acquisition (SCADA) Communications Protocol (SSCP) from Pacific Northwest National Laboratories (PNNL) to Schweitzer Engineering Laboratories (SEL). The project shall use this technology to develop a Federal Information Processing Standard (FIPS) 140-2 compliant original equipment manufacturer (OEM) module to be called a Cryptographic Daughter Card (CDC) with the ability to directly connect to any PC enabling that computer to securely communicate across serial to field devices. Validate the OEM capabilities with another vendor. 2. Development of a Link Authenticator Module (LAM) using the FIPS 140-2 validated Secure SCADA Communications Protocol (SSCP) CDC module with a central management software kit. 3. Validation of the CDC and Link Authenticator modules via laboratory and field tests. 4. Creation of documents that record the impact of the Link Authenticator to the operators of control systems and on the control system itself. The information in the documents can assist others with technology deployment and maintenance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Genomics-enabled sensor platform for rapid detection of viruses related to disease outbreak.

Bioweapons and emerging infectious diseases pose growing threats to our national security. Both natural disease outbreak and outbreaks due to a bioterrorist attack are a challenge to detect, taking days after the outbreak to identify since most outbreaks are only recognized through reportable diseases by health departments and reports of unusual diseases by clinicians. In recent decades, arthropod-borne viruses (arboviruses) have emerged as some of the most significant threats to human health. They emerge, often unexpectedly, from cryptic transmission foci causing localized outbreaks that can rapidly spread to multiple continents due to increased human travel and trade. Currently, diagnosis of acute infections requires amplification of viral nucleic acids, which can be costly, highly specific, technically challenging and time consuming. No diagnostic devices suitable for use at the bedside or in an outbreak setting currently exist. The original goals of this project were to 1) develop two highly sensitive and specific diagnostic assays for detecting RNA from a wide range of arboviruses; one based on an electrochemical approach and the other a fluorescent based assay and 2) develop prototype microfluidic diagnostic platforms for preclinical and field testing that utilize the assays developed in goal 1. We generated and characterized suitable primers for West Nile Virus RNA detection. Both optical and electrochemical transduction technologies were developed for DNA-RNA hybridization detection and were implemented in microfluidic diagnostic sensing platforms that were developed in this project.

Brozik, Susan M↗

Environmental Responses to Carbon Mitigation through Geological Storage

In summary, this DOE EPSCoR project is contributing to the study of carbon mitigation through geological storage. Both deep and shallow subsurface research needs are being addressed through research directed at improved understanding of environmental responses associated with large scale injection of CO 2 into geologic formations. The research plan has two interrelated research objectives. Objective 1: Determine the influence of CO 2 -related injection of fluids on pore structure, material properties, and microbial activity in rock cores from potential geological carbon sequestration sites. Objective 2: Determine the Effects of CO 2 leakage on shallow subsurface ecosystems (microbial and plant) using field experiments from an outdoor field testing facility.

54 ENVIRONMENTAL SCIENCES↗

Effects of precipitation manipulation on carbohydrate dynamics and mortality in a pinon-juniper woodland

Drought-induced forest mortality is an increasing global problem with farreaching consequences, yet mortality mechanisms remain poorly understood. Depletion of non-structural carbohydrate (NSC) stores has been implicated as a major factor in drought-induced mortality, but experimental field tests are rare. We conducted an ecosystem-scale precipitation manipulation experiment and evaluated leaf and twig NSC dynamics of two co-occurring conifers with different water regulation strategies; the relatively drought-averse piñon pine (Pinus edulis) and relatively drought-tolerant oneseed juniper (Juniperus monosperma). Experimental drought caused decreased leaf starch in dying trees of both species and increased allocation to glucose and fructose in juniper, consistent with osmoregulation requirements. For both species, average leaf starch content between drought treatment initiation and mortality was a good predictor (R2 = 0.77) of the survival duration. These results, along with observations of drought-induced reductions to photosynthesis and growth, implicate carbon starvation as an important process during mortality of these two conifer species.

54 ENVIRONMENTAL SCIENCES↗

Low Cost Sorbent for Capturing CO 2 Emissions Generated by Existing Coal-fired Power Plants

TDA Research, Inc. has developed a novel sorbent based post-combustion CO 2 removal technology. This low cost sorbent can be regenerated with low-pressure (ca. 1 atm) superheated steam without temperature swing or pressure-swing. The isothermal and isobaric operation is a unique and advantageous feature of this process. The objective of this project was to demonstrate the technical and economic merit of this sorbent based CO 2 capture approach. Through laboratory, bench-scale and field testing we demonstrated that this technology can effectively and efficiently capture CO 2 produced at an existing pulverized coal power plants. TDA Research, Inc is developing both the solid sorbent and the process designed around that material. This project addresses the DOE Program Goal to develop a capture technology that can be added to an existing or new coal fired power plant, and can capture 90% of the CO 2 produced with the lowest possible increase in the cost of energy. .

20 FOSSIL-FUELED POWER PLANTS↗

Multiple-Input Data Acquisition System (MIDAS) for Measuring the Carbon Content in Soil Using Inelastic Neutron Scattering

This report describes work funder under STTR grants Phase I and II and carried out jointly by XIA LLC and Brookhaven National Laboratory (BNL). The project goal was to develop a mobile nuclear activation analysis instrument that could be towed behind a tractor to document soil carbon levels in agricultural lands for carbon credit certification. XIA developed large NaI(Tl) detectors with integrated digital pulse processors controlled over USB 2.0 and delivered 16 of these units to BNL for integration into the prototype instrument, together with the necessary software to calibrate them and collect data. For reasons that are unknown to XIA, the BNL participants never completed the prototype vehicle, performed system integration, or carried out the proposed qualification and field tests, leaving the project incomplete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Power Controls from Wind Power: Bridging the Gaps

This paper details a comprehensive study undertaken by the National Renewable Energy Laboratory, Electric Power Research Institute, and the University of Colorado to understand how the contribution of wind power providing active power control (APC) can benefit the total power system economics, increase revenue streams, improve the reliability and security of the power system, and provide superior and efficient response while reducing any structural and loading impacts that may reduce the life of the wind turbine or its components. The study includes power system simulations, control simulations, and actual field tests using turbines at NREL's National Wind Technology Center (NWTC). The study focuses on synthetic inertial control, primary frequency control, and automatic generation control, and analyzes timeframes ranging from milliseconds to minutes to the lifetime of wind turbines, locational scope ranging from components of turbines to large wind plants to entire synchronous interconnections, and additional topics ranging from economics to power system engineering to control design.

17 WIND ENERGY↗

Developing Spent Fuel Assembly for Advanced NDA Instrument Calibration - NGSI Spent Fuel Project

This report summarizes the work by Oak Ridge National Laboratory to investigate the application of modeling and simulation to support the performance assessment and calibration of the advanced nondestructive assay (NDA) instruments developed under the Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) Project. Advanced NDA instrument calibration will likely require reference spent fuel assemblies with well-characterized nuclide compositions that can serve as working standards. Because no reference spent fuel standard currently exists, and the practical ability to obtain direct measurement of nuclide compositions using destructive assay (DA) measurements of an entire fuel assembly is prohibitive in the near term due to the complexity and cost of spent fuel experiments, modeling and simulation will be required to construct such reference fuel assemblies. These calculations will be used to support instrument field tests at the Swedish Interim Storage Facility (Clab) for Spent Nuclear Fuel.

Hu, Jianwei↗

99 Tc Process Monitoring System In-Lab Performance Characterization

A 99 Tc Process Monitoring (Tc-Mon) System has been designed and built for deployment at the recently constructed 200 West Pump & Treat (200W P&T) Plant in the 200 West Area ZP-1 Operable Unit of the Hanford Site. The plant is operated by CH2M Hill Plateau Remediation Company (CHPRC). The Tc-Mon system was created through collaboration between Pacific Northwest National Laboratory (PNNL) and Burge Environmental, Inc. The design of the new system has been optimized based on experience from an earlier field test (2011) of a prototype system at the 200W-ZP-1 Interim Pump & Treat Plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wave Energy Converter Effects on Wave Fields: Evaluation of SNL-SWAN and Sensitivity Studies in Monterey Bay CA.

A modified version of an indust ry standard wave modeling tool was evaluated, optimized, and utilized to investigate model sensitivity to input parameters a nd wave energy converter ( WEC ) array deployment scenarios. Wave propagation was investigated d ownstream of the WECs to evaluate overall near - and far - field effects of WEC arrays. The sensitivity study illustrate d that wave direction and WEC device type we r e most sensitive to the variation in the model parameters examined in this study . Generally, the changes in wave height we re the primary alteration caused by the presence of a WEC array. Specifically, W EC device type and subsequently their size directly re sult ed in wave height variations; however, it is important to utilize ongoing laboratory studies and future field tests to determine the most appropriate power matrix values for a particular WEC device and configuration in order to improve modeling results .

Roberts, Jesse D.↗

Smart and Green Energy (SAGE) for Base Camps Final Report

The U.S. Army Logistics Innovation Agency’s (LIA’s) Smart and Green Energy (SAGE) for Base Camps project was to investigate how base camps’ fuel consumption can be reduced by 30% to 60% using commercial off-the-shelf (COTS) technologies for power generation, renewables, and energy efficient building systems. Field tests and calibrated energy models successfully demonstrated that the fuel reductions are achievable.

energy↗

Subtask 4.27 - Evaluation of the Multielement Sorbent Trap (MEST) Method at an Illinois Coal-Fired Plant

Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer a potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels that would interfere with accurate measurement at U.S. hazardous air pollutant emission limits for existing coal-fired power plant units. Longer sampling times employed during this test program did appear to improve comparative results for these metals. Although the sorbent contribution to the sample was reduced through improved trap design, additional research is still needed to explore lower-background materials before the MEST-M application can be considered as a potential alternative method for all of the trace metals. This subtask was funded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Electric Power Research Institute, the Illinois Clean Coal Institute, Southern Illinois Power Company, and the Center for Air Toxic Metals Affiliates Program.

Pavlish, John↗

Deep Borehole Disposal Research: Geological Data Evaluation Alternative Waste Forms and Borehole Seals

This report documents deep borehole disposal research during FY2014, as directed by U.S. Department of Energy (DOE) Used Fuel Disposition (UFD) Campaign. These research efforts are principally directed at advancing the deep borehole disposal project to the implementation of a full-scale Research, Development, and Demonstration (RD&D) project. Activities of particular relevance to this goal include evaluation of guidelines for selection of a deep borehole field test site, analyses of deep borehole disposal of alternative waste forms, and technical planning for borehole seals research.

Arnold, Bill W.↗

Minimizing User Burden in Building Energy Analysis

Infrared (IR) imagery can provide valuable data to building energy auditors and the developers of Building Energy Models (BEM). IR by itself is not a panacea to the challenges facing energy auditors and modelers, but when combined with other techniques and Open Studio software, IR can play an important role in the minimization of the burden of creating building energy models and the diagnosing of building energy problems. While IR can be used to detect and quantify many aspects of a building’s thermal and energy performance, in Phase I we focused on a single capability: determining the R value of exterior walls. Two key attributes of using IR methods for R value determination is that IR methods measure the actual, installed performance in-situ – as opposed to relying on manufacturer or handbook values – and they can integrate performance over a wide area and thus can accurately account for thermal bridging and spatial anomalies such as “spotty” insulation installation. There is a trade between user burden and accuracy when using IR to determine a wall’s R value. The least burdensome approach is computing R values from a single IR snapshot. The most burdensome method we considered was to combine IR images with thermocouple and heat flux sensor (HFS) measurements made over the course of several days. The more effort users expend in making the measurements, the more accurate and robust the method becomes. Through a series of field tests at the ThermoAnalytics Inc. (TAI) HQ at Calumet, MI and a simulation of a 1980s era office building in Flagstaff, AZ we investigated methods to compute the R value of exterior walls using data from IR cameras, thermocouples and heat flux sensors. To compute R values the heat flux through the wall, along with temperatures on either side of the wall, must be known, modeled, or estimated – and the temperature difference through the wall should be at least 10 C. If only outdoor IR images are used in the method, the inside ambient air temperature must be estimated, and a simulation model created to predict heat fluxes and the indoor wall temperature. The accuracy of the resulting R value depends on the accuracy of the simulation and the assumptions it employs. Applying thermocouple sensors, either as iButtons or as part of a wireless sensor network, to the walls allows for the acquisition of temperatures over time. The longer the duration of the measurements, the more accurate and robust the method will be. Even with this level of measurement effort, modeling is still required to calculate the heat flux through the wall. The addition of a heat flux sensor alleviates the need for any modeling, and that results in improved accuracy. Driving the accuracy of the methods are several factors that can be quantified. How well are the wall surface temperatures known? Modeling the heat flux through walls requires knowing the details of the surrounding radiant environment and the heat transfer due to convection. How well are these boundary conditions known? Even when the heat flux is measured, error can arise when some of the measured heat is not conducted through the wall but rather goes into the thermal mass of the wall. Thermal mass effects occur when conditions and the heat flux values are fluctuating. A technique that is not robust will suffer in accuracy when these fluctuations occur. The R value determination method must be incorporated into the Open Studio process. In our proposed process, IR images and other measured sensor data are input into a module that would send R value estimates to a building library developed by team member Skidmore, Owings, & Merrill (SOM). This library of parameterized building models would use these R values along with information about the building’s age, type, and location to query the Open Studio BCL to identify the most likely constructions for walls, roof, and windows. Being based on the IMF feature of Energyplus, the SOM building library can quickly produce Energyplus models of buildings based on a limited number of user inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground water and snow sensor based on directional detection of cosmogenic neutrons

A fast neutron detector is being developed to measure the cosmic ray neutron flux in order to measure soil moisture. Soil that is saturated with water has an enhanced ability to moderate fast neutrons, removing them from the backscatter spectrum. The detector is a two-element, liquid scintillator detector. The choice of liquid scintillator allows rejection of gamma background contamination from the desired neutron signal. This enhances the ability to reconstruct the energy and direction of a coincident neutron event. The ability to image on an event-by-event basis allows the detector to selectively scan the neutron flux as a function of distance from the detector. Calibrations, simulations, and optimization have been completed to understand the detector response to neutron sources at variable distances and directions. This has been applied to laboratory background measurements in preparation for outdoor field tests.

47 OTHER INSTRUMENTATION↗

Low-Cost Co-Production of Hydrogen and Electricity

The purpose of this study is to further the efforts of low-cost co-production of hydrogen and electricity. Hydrogen price parity with gasoline is an imperative if hydrogen is to be used for transportation fuel. A distributed, rather than centralized, generation approach to hydrogen production avoids infrastructure costs and allows for safer and more convenient distribution to customers. Bloom Energy’s (BE’s) systems, when manufactured in high volume, can produce low cost hydrogen by co-producing hydrogen and electricity simultaneously with one common set of lowcost equipment. The main objectives of this project have been to 1) deliver and field test a pilot plant producing high purity hydrogen and electricity in Alaska; 2) show the feasibility of a delivered cost of hydrogen below $2.50 per gge; 3) demonstrate that our systems can run on liquid fuels; and 4) create learning opportunities regarding commercial customer needs so that the DOE and BE can use this demonstration project to gain critical insights necessary to build, deliver and install a commercially viable stationary fuel cell-based hydrogen/electricity coproduction system. Over the course of this project, BE has successfully demonstrated the ability to build and operate a PSOFC for 12 months, with a peak efficiency over 50%, while improving the understanding of operating requirements in cold weather. BE also demonstrated the capability to co-produce electricity and hydrogen, and to generate pure hydrogen in volumes of 19.3 kg/day; and additionally demonstrated the feasibility of a delivered cost of hydrogen below $2.50 per gge.

08 HYDROGEN↗