Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Precision time distribution within a deep space communications complex

The Precision Time Distribution System (PTDS) at the Golstone Deep Space Communications Complex is a practical application of existing technology to the solution of a local problem. The problem was to synchronize four station timing systems to a master source with a relative accuracy consistently and significantly better than 10 microseconds. The solution involved combining a precision timing source, an automatic error detection assembly and a microwave distribution network into an operational system. Upon activation of the completed PTDS two years ago, synchronization accuracy at Goldstone (two station relative) was improved by an order of magnitude. It is felt that the validation of the PTDS mechanization is now completed. Other facilities which have site dispersion and synchronization accuracy requirements similar to Goldstone may find the PTDS mechanization useful in solving their problem. At present, the two station relative synchronization accuracy at Goldstone is better than one microsecond.

Curtright, J. B.↗

Method and system for redundancy management of distributed and recoverable digital control system

A method and system for redundancy management is provided for a distributed and recoverable digital control system. The method uses unique redundancy management techniques to achieve recovery and restoration of redundant elements to full operation in an asynchronous environment. The system includes a first computing unit comprising a pair of redundant computational lanes for generating redundant control commands. One or more internal monitors detect data errors in the control commands, and provide a recovery trigger to the first computing unit. A second redundant computing unit provides the same features as the first computing unit. A first actuator control unit is configured to provide blending and monitoring of the control commands from the first and second computing units, and to provide a recovery trigger to each of the first and second computing units. A second actuator control unit provides the same features as the first actuator control unit.

Stange, Kent↗

Robust and resilient coordination of feeders with uncertain distributed energy resources: from real-time control to long-term planning

To enable flexible demand and ensure reliable and economical operation of distribution systems, we present a novel hierarchical scheme that actively coordinates responsive behind-the-meter grid resources, including distributed energy resources (DERs), to reliably manage each unbalanced distribution feeder and exploits the available flexibility to economically optimize the entire network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

14 SOLAR ENERGY↗

Digitalization in Electric Power Systems and Regulation: A Primer

This report defines grid digitalization, provides concrete examples, and assesses five elements of digital systems that have evolved over the past three decades relevant to the electric distribution system: (1) network interconnection, (2) interoperability, (3) modularity, (4) open source, and (5) automation. This report also discusses the benefits and challenges of digitalization and provides a set of actions regulators can take to support the transition and realize the benefits of the transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A new communication protocol family for a distributed spacecraft control system

In this paper we describe the concepts behind and architecture of a communication protocol family, which was designed to fulfill the communication requirements of ESOC's new distributed spacecraft control system SCOS 2. A distributed spacecraft control system needs a data delivery subsystem to be used for telemetry (TLM) distribution, telecommand (TLC) dispatch and inter-application communication, characterized by the following properties: reliability, so that any operational workstation is guaranteed to receive the data it needs to accomplish its role; efficiency, so that the telemetry distribution, even for missions with high telemetry rates, does not cause a degradation of the overall control system performance; scalability, so that the network is not the bottleneck both in terms of bandwidth and reconfiguration; flexibility, so that it can be efficiently used in many different situations. The new protocol family which satisfies the above requirements is built on top of widely used communication protocols (UDP and TCP), provides reliable point-to-point and broadcast communication (UDP+) and is implemented in C++. Reliability is achieved using a retransmission mechanism based on a sequence numbering scheme. Such a scheme allows to have cost-effective performances compared to the traditional protocols, because retransmission is only triggered by applications which explicitly need reliability. This flexibility enables applications with different profiles to take advantage of the available protocols, so that the best rate between sped and reliability can be achieved case by case.

Baldi, Andrea↗

Estimation of discontinuous coefficients in parabolic systems - Applications to reservoir simulation

Spline-based techniques for estimating spatially varying parameters that appear in parabolic distributed systems (typical of those found in reservoir simulation problems) are presented. In particular, the problem of determining discontinuous coefficients is discussed, estimating both the functional shape and points of discontinuity for such parameters. In addition, the ideas may also be applied to problems with unknown initial conditions and unknown parameters appearing in terms representing external forces. Convergence results and a summary of numerical performance of the resulting algorithms are given.

Lamm, Patricia K.↗

A Spatial Analysis and Modeling System (SAMS) for environment management

This is a proposal to develop a uniform global environmental data gathering and distribution system to support the calibration and validation of remotely sensed data. SAMS is based on an enhanced version of FE MA's Integrated Emergency Management Information Systems and the Department of Defense's Air Land Battlefield Environment Software Systems. This system consists of state-of-the-art graphics and visualization techniques, simulation models, database management and expert systems for conducting environmental and disaster preparedness studies. This software package will be integrated into various Landsat and UNEP-GRID stations which are planned to become direct readout stations during the EOS timeframe. This system would be implemented as a pilot program to support the Tropical Rainfall Measuring Mission (TRMM). This will be a joint NASA-FEMA-University-Industry project.

Vermillion, Charles H.↗

A Spatial Analysis and Modeling System (SAMS) for environment management

This is a proposal to develop a uniform global environmental data gathering and distribution system to support the calibration and validation of remotely sensed data. SAMS is based on an enhanced version of FEMA's Integrated Emergency Management Information Systems and the Department of Defense's Air land Battlefield Environment Software Systems. This system consists of state-of-the-art graphics and visualization techniques, simulation models, database management and expert systems for conducting environmental and disaster preparedness studies. This software package will be integrated into various Landsat and UNEP-GRID stations which are planned to become direct readout stations during the EOS (Earth Observing System) timeframe. This system would be implemented as a pilot program to support the Tropical Rainfall Measuring Mission (TRMM). This will be a joint NASA-FEMA-University-Industry project.

Stetina, Fran↗

Thermal Integration of DETAIL Systems

A thermal connection between the Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) and the thermal energy distribution system (TEDS) has been a key part of the Dynamic Energy Transport and Integration Laboratory (DETAIL) plan since the development of the Integrated Energy Systems Roadmap in 2020. This connection provides an expanding demonstration capability for integrated system operations. The thermal connection between MAGNET and TEDS required the selection of a heat exchanger and valves to isolate flow. Research staff within the NEET Crosscutting Technology Development program selected equipment after receiving proposals from multiple vendors. A helical coil heat exchanger from Graham Corporation was selected for its small volume relative to its heat transfer surface area to fit in the limited space available. Triple offset butterfly valves with pneumatic actuators from Flowserve were selected to isolate and/or control flow of the hot gas through the heat exchanger. Staff from Idaho National Laboratory’s (INL) Facilities and Site Services Engineering department designed the piping and structural support. A mechanical construction firm was contracted to install the system. This report documents the design and construction of this thermal connection.

25 ENERGY STORAGE↗

Towards Robustness Guarantees for Feedback-Based Optimization

Feedback-based online optimization algorithms have gained traction in recent years because of their simple implementation, their ability to reject disturbances in real time, and their increased robustness to model mismatch. While the robustness properties have been observed both in simulation and experimental results, the theoretical analysis in the literature is mostly limited to nominal conditions. In this work, we propose a framework to systematically assess the robust stability of feedback-based online optimization algorithms. We leverage tools from monotone operator theory, variational inequalities and classical robust control to obtain tractable numerical tests that guarantee robust convergence properties of online algorithms in feedback with a physical system, even in the presence of disturbances and model uncertainty. The results are illustrated via an academic example and a case study of a power distribution system.

approximation algorithms↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Optimally sited microgrids for energy resilience in Mount Desert Island, ME

Mount Desert Island (MDI) (≈110 sq mi; ≈10,000 year‑round residents) is located on the eastern coast of Maine. Acadia National Park is located on the island, protecting 47,000+ acres of land which draws millions of visitors annually. The island is divided into four towns (Tremont, Southwest Harbor, Mount Desert, Bar Harbor). The island’s distribution system is supplied by a single 35‑kV mainland feeder and a mix of aging distribution components; outage exposure is not uniform across the island. Residents fear that outage events are starting to exceed resilience expectations. MDI community leaders asked Sandia National Laboratories to characterize energy system vulnerability and to develop conceptual microgrid solutions that improve community resilience while also producing co‑benefits for reliability, access, and sustainable development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

All-Source Competitive Solicitations: State and Electric Utility Practices

This report provides an overview of principles, practices, and emerging issues in all-source competitive solicitations. It reviews the history of electric utility all-source solicitations and recent results; provides an overview of goals, design tradeoffs, and stages; and examines solicitation design and implementation options and issues, including methodological issues around bid evaluation. The report draws on a review of regulatory documents, resource plans, solicitation materials, independent evaluator reports, and scholarly literature. While the report focuses on solicitations by investor-owned utilities for bulk power system needs, it also briefly discusses solicitations for non-wires alternatives for distribution system needs, as well as nascent practices for integrating both types of procurements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Test results from a breadboard cryogenic propellant condition assembly

Cryogenic auxiliary propulsion systems consist of five major subsystems: propellant tanks, propellant conditioning assemblies, accumulators, propellant distribution systems, and thrustors. The propellant conditioning assembly (PCA) converts low pressure liquid to high pressure gas for use by the thrustors, and is one of the most complex subsystems of the cryogenic propulsion system. The ability to achieve rapid starts and at the same time maintain system control are two critical areas of PCA operation. To investigate these critical areas of operation, a PCA of the general type required was designed, fabricated, and tested using existing hardware. Realistic start times were achieved and system control was maintained at all operating conditions.

Stinson, H. P., Jr.↗

Solar Power Satellite (SPS) fiber optic link assessment

A feasibility demonstration of a 980 MHz fiber optic link for the Solar Power Satellite (SPS) phase reference distribution system was accomplished. A dual fiber-optic link suitable for a phase distribution frequency of 980 MHz was built and tested. The major link components include single mode injection laser diodes, avalanche photodiodes, and multimode high bandwidth fibers. Signal throughput was demonstrated to be stable and of high quality in all cases. For a typical SPS link length of 200 meters, the transmitted phase at 980 MHz varies approximately 2.5 degrees for every deg C of fiber temperature change. This rate is acceptable because of the link length compensation feature of the phase control design.

Source record↗

Saturn's magnetic tail - Structure and dynamics

Voyager 1 magnetic field observations have provided evidence of a Saturnian magnetic tail. Tail current system distributions are inferred through comparison of the observations with a realistic magnetotail current system model. Temporal variations observed in the tail were probably produced by solar wind variations.

Behannon, K. W.↗

Extending the granularity of representation and control for the MIL-STD CAIS 1.0 node model

The Common APSE (Ada 1 Program Support Environment) Interface Set (CAIS) (DoD85) node model provides an excellent baseline for interfaces in a single-host development environment. To encompass the entire spectrum of computing, however, the CAIS model should be extended in four areas. It should provide the interface between the engineering workstation and the host system throughout the entire lifecycle of the system. It should provide a basis for communication and integration functions needed by distributed host environments. It should provide common interfaces for communications mechanisms to and among target processors. It should provide facilities for integration, validation, and verification of test beds extending to distributed systems on geographically separate processors with heterogeneous instruction set architectures (ISAS). Additions to the PROCESS NODE model to extend the CAIS into these four areas are proposed.

Rogers, Kathy L.↗

Investigation of Silver Biocide as a Disinfection Technology for Spacecraft-An Early Literature Review

An ideal spacecraft water disinfection system should prevent or control microbial growth, inhibit or prevent biofilm formation, and prevent microbial-induced corrosion. In addition, the selected biocide system should be chemically compatible with materials used in the water storage and distribution system, have minimal maintenance requirements, especially for long-duration missions, and should be safe for crew consumption at levels appropriate for biocidal control. Silver ion is a proven broad spectrum biocide. There has been an increased interest in the biocidal function of silver, both due to its potential to control biocide resistant species and due to advances in silver and nanosilver biocide technologies. NASA is considering silver as the future biocide for exploration over the iodine biocide system. In order to select and design a successful silver biocide delivery system to meet NASA's requirements, it is essential to understand the advantages and disadvantages of moving to a silver disinfection system. To enhance the knowledge base for the application of silver biocides in spacecraft water systems, this paper provides a first compilation of review data related to: (1) Silver as a biocide technology, (2) Options and concepts for silver biocide delivery, and (3) Silver biocide compatibility studies for spacecraft systems.

Li, Wenyan↗