Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Use of 2nd and 3rd Level Correlation Analysis for Studying Degradation in Polycrystalline Thin-Film Solar Cells

The correlation of stress-induced changes in the performance of laboratory-made CdTe solar cells with various 2nd and 3rd level metrics is discussed. The overall behavior of aggregated data showing how cell efficiency changes as a function of open-circuit voltage (Voc), short-circuit current density (Jsc), and fill factor (FF) is explained using a two-diode, PSpice model in which degradation is simulated by systematically changing model parameters. FF shows the highest correlation with performance during stress, and is subsequently shown to be most affected by shunt resistance, recombination and in some cases voltage-dependent collection. Large decreases in Jsc as well as increasing rates of Voc degradation are related to voltage-dependent collection effects and catastrophic shunting respectively. Large decreases in Voc in the absence of catastrophic shunting are attributed to increased recombination. The relevance of capacitance-derived data correlated with both Voc and FF is discussed.

14 SOLAR ENERGY↗

Nanoscale determinant to brighten up GaN:Eu red light-emitting diode: Local potential of Eu-defect complexes

Emission sites in GaN:Eu red light-emitting diodes (LEDs) were investigated using a new spectroscopy technique, namely, site-selective pulse-driven emission spectroscopy (PDES). The PDES, in which the emission intensity of a pulse-driven LED is recorded with respect to the pulse frequency, revealed the charge-trapping dynamics of the Eu emission sites. We found that a determinant of the emission intensity of the sites was not their relative abundance, but rather the spatial extent of the local potential, which determines the effectiveness of the capture of injection charges. Minor sites with wider potentials enhanced the emission intensity of the LED, resulting in emission spectra that differ from those obtained using the photoluminescence of a GaN:Eu thin film. The potential curve is determined by the atomic structure of the complexes, which consist of a Eu dopant and nearby defects in the GaN host. The extent was characterized by a parameter, namely, cutoff frequency, and the emission sites with the wider and narrower potentials in the GaN:Eu LED were found to have cutoff frequencies of 400 kHz and 3 MHz, respectively. The cutoff frequency of 3 MHz was found to be the upper limit for emission sites in the LED. The emission site with the wider potential is useful for slower devices such as light fixtures, while the site with the narrower potential is useful for faster devices such as opto-isolators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2020 U.S. Lighting Market Characterization

The Lighting Market Characterization report details how many lighting products (lamps and luminaires) were installed in the U.S. as of 2020, where they were installed, and how much energy they consumed. It also highlights key changes in U.S. lighting market characteristics between 2015 and 2020. This is the fourth edition of the LMC report; previous versions were released in 2002, 2012 and 2017. By publishing summary estimates of installed stock and energy use of various general illumination lighting products, these reports help DOE and others plan effective lighting research and development programs based on changing needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Welding Induced Alignment Distortion in Dual-in-Line LD Packages

The tolerance for the movement of a single mode fiber relative to the laser is extremely tight, a submicron movement can often lead to a significant misalignment and thus the reduction in the power coupled into the fiber. Among various fiber pigtailing assembly technologies, pulsed laser welding is the method with submicron accuracy and is most conducive to automation. However, the melting-solidification process during laser welding can often distort the pre-achieved fiber-optic alignment. This Welding-Induced-Alignment-Distortion (WIAD) is a serious concern and significantly affects the yield for single mode fiber pigtailing to a semiconductor laser. In this paper, effect of laser welding sequence on WIAD in a dual-in-line packager is numerically investigated by means of Finite Element Method (FEM). Optimal welding sequence may minimize WIAD in dual-in-line package. Additionally, unsymmetrical space between fiber and U-channel induced by laser welding of U-channel–to-plate in DIP LD packages is found to have obvious effect on WIAD.

42 ENGINEERING↗

Soft holographic interference lithography microlens for enhanced organic light emitting diode light extraction

Very uniform 2 {micro}m-pitch square microlens arrays ({micro}LAs), embossed on the blank glass side of an indium-tin-oxide (ITO)-coated 1.1 mm-thick glass, are used to enhance light extraction from organic light-emitting diodes (OLEDs) by {approx}100%, significantly higher than enhancements reported previously. The array design and size relative to the OLED pixel size appear to be responsible for this enhancement. The arrays are fabricated by very economical soft lithography imprinting of a polydimethylsiloxane (PDMS) mold (itself obtained from a Ni master stamp that is generated from holographic interference lithography of a photoresist) on a UV-curable polyurethane drop placed on the glass. Green and blue OLEDs are then fabricated on the ITO to complete the device. When the {mu}LA is {approx}15 x 15 mm{sup 2}, i.e., much larger than the {approx}3 x 3 mm{sup 2} OLED pixel, the electroluminescence (EL) in the forward direction is enhanced by {approx}100%. Similarly, a 19 x 25 mm{sup 2} {mu}LA enhances the EL extracted from a 3 x 3 array of 2 x 2 mm{sup 2} OLED pixels by 96%. Simulations that include the effects of absorption in the organic and ITO layers are in accordance with the experimental results and indicate that a thinner 0.7 mm thick glass would yield a {approx}140% enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feedback-Controlled LED Photobioreactor for Photophysiological Studies of Cyanobacteria

A custom photobioreactor (PBR) was designed to enable automatic light adjustments using computerized feedback control. A black anodized aluminum enclosure, constructed to surround the borosilicate reactor vessel, prevents the transmission of ambient light and serves as a mount for arrays of light-emitting diodes (LEDs). The high-output LEDs provide narrow-band light of either 630 or 680 nm for preferential excitation of the cyanobacterial light-harvesting pigments, phycobilin or chlorophyll a, respectively. Custom developed software BioLume provides automatic control of optical properties and a computer feedback loop can automatically adjust the incident irradiance as necessary to maintain a fixed transmitted light through the culture, based on user-determined set points. This feedback control serves to compensate for culture dynamics which have optical effects, (e.g., changing cell density, pigment adaptations) and thus can determine the appropriate light conditions for physiological comparisons or to cultivate light-sensitive strains, without prior analyses. The LED PBR may also be controlled as a turbidostat, using a feedback loop to continuously adjust the rate of media-dilution based on the transmitted light measurements, with a fast and precise response. This cultivation system gains further merit as a high-performance analytical device, using non-invasive tools (e.g., dissolved gas sensors, online mass spectrometry) to automate real-time measurements, thus permitting unsupervised experiments to search for optimal growth conditions, to monitor physiological responses to perturbations, as well as to quantitate photophysiological parameters using an in situ light-saturation response routine.

controlled cultivation↗

Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period was 5 s, with the resulting average motion speed of 1.45 cm/s. The motion-perturbed high resolution (2 mm voxel) volumetric dose grids on the MC2 phantom were generated for each beam. From each grid, a coronal dose plane at the detector level was extracted and compared to the corresponding moving MC2 measurement, using gamma analysis with both global (G) and local (L) dose-error normalization. Results: Using the TG-119 criteria of (3%G/3 mm), per beam average gamma analysis passing rates exceeded 95% in all cases. No individual beam had a passing rate below 91%. LDVE correction eliminated systematic disagreement patterns at the beams’ aperture edges. In a representative example, application of LDVE correction improved (2%L/2 mm) gamma analysis passing rate for an IMRT beam from 74% to 98%. Conclusions: The effect of motion on the moving region-of-interest IMRT dose can be estimated with a standard, static phantom QA measurement, provided the motion characteristics are independently known from 4D CT or otherwise. The motion-perturbed absolute dose estimates were validated by the direct planar diode array measurements, and were found to reliably agree with them in a homogeneous phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultranarrow electroluminescence from magnetic excitons in the van der Waals antiferromagnetic semiconductor NiPS 3

Electrically driven light emission from two-dimensional (2D) semiconducting materials has enabled numerous optoelectronic technologies, including light-emitting diodes, solid-state lasers, and single-photon sources for quantum communication. Here we report ultranarrow electroluminescence from the magnetic excitonic state of the van der Waals antiferromagnetic semiconductor NiPS 3 . This electroluminescence is enabled by the fabrication of gate-tunable NiPS 3 devices that remain electrically conductive below the antiferromagnetic ordering temperature of 155 K, ultimately allowing field-effect mobilities of 1.3 cm 2 V –1 s –1 and 4.5 cm 2 V –1 s –1 to be directly measured at room temperature and 7 K, respectively. By applying a high-frequency square wave voltage to the gate electrode of the resulting field-effect transistors, electroluminescence is capacitively induced from the magnetic excitons of NiPS 3 . Due to the coupling of these excitons with the underlying NiPS 3 antiferromagnetic order, the electroluminescence has an ultranarrow linewidth of 1 meV and a high degree of linear polarization (ρ = 0.78). In addition to facilitating fundamental studies of the coupling between spin states and excitons in van der Waals magnetic semiconductors, this work will accelerate the development of emerging 2D opto-spintronic applications.

two-dimensional materials↗

Solitary pulse-on-demand production by optical injection locking of passively Q-switched InGaN diode laser near lasing threshold

In this letter, we investigate the behavior of a Q-switched InGaN multi-section laser diode (MSLD) under optical injection from a continuous wave external cavity diode laser. We obtain solitary optical pulse generation when the slave MSLD is driven near free running threshold, and the peak output power is significantly enhanced with respect to free running configuration. When the slave laser is driven well above threshold, optical injection reduces the peak power. Using standard semiconductor laser rate equation model, we find that both power enhancement and suppression effects are the result of partial bleaching of the saturable absorber by externally injected photons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Threshold Switching and Memory Behaviors of Epitaxially Regrown GaN-on-GaN Vertical $p-n$ Diodes With High Temperature Stability

This letter reports the observation of threshold switching and memory behaviors of epitaxially regrown GaN-on-GaN vertical p-n diodes. This mechanism was ascribed to the conductive path formed by traps in the insulating layer at the regrowth interface after soft breakdown. The device can reliably switch more than 1000 cycles at both room temperature and 300 °C with small fluctuation on the set and reset voltage. The set voltage increased with the increasing temperature due to the enhanced thermal detrapping effect that made it harder to form conductive path at high temperatures. Besides, the device showed memory behaviors when the reset voltage was higher than 4.4 V. This letter can serve as an important reference to further developing GaN-based memory devices and integrated circuits.

36 MATERIALS SCIENCE↗

SU-F-T-579: Extrapolation Techniques for Small Field Dosimetry Using Gafchromic EBT3 Film

Purpose: The purpose of this project is to test an experimental approach using an extrapolation technique for Gafchromic EBT3 film for small field x-ray dosimetry. Methods: Small fields from a Novalis Tx linear accelerator with HD Multileaf Collimators with 6 MV was used. The field sizes ranged from 5 × 5 to 50 × 50 mm2 MLC fields and a range of circular cones of 4 to 30 mm2 diameters. All measurements were performed in water at an SSD of 100 cm and at a depth of 10 cm. The relative output factors (ROFs) were determined from an extrapolation technique developed to eliminate the effects of partial volume averaging in film scan by scanning films with high resolution (1200 DPI). The size of the regions of interest (ROI) was varied to produce a plot of ROFs versus ROI which was then extrapolated to zero ROI to determine the relative output factor. The results were compared with other solid state detectors with proper correction, namely, IBA SFD diode, PTW 60008 and PTW 60012 diode. Results: For the 4 mm cone, the extrapolated ROF had a value of 0.658 ± 0.014 as compared to 0.642 and 0.636 for 0.5 mm and 1 mm2 ROI analysis, respectively. This showed a change in output factor of 2.4% and 3.3% at this comparative ROI sizes. In comparison, the 25 mm cone had a difference in measured output factor of 0.3% and 0.5% between 0.5 and 1.0 mm, respectively compared to zero volume. For the fields defined by MLCs a difference of up to 2% for 5×5 mm2 was observed. Conclusion: A measureable difference can be seen in ROF based on the ROI when radiochromic film is used. Using extrapolation technique from high resolution scanning a good agreement can be achieved.

60 APPLIED LIFE SCIENCES↗

Countermeasure for Radiation Protection and Repair

Exposure to ionizing radiation during long-duration space missions is expected to cause short-term illness and increase long-term risk of cancer for astronauts. Radiation-induced free radicals overload the antioxidant defense mechanisms and lead to cellular damage at the membrane, enzyme, and chromosome levels. A large number of radioprotective agents were screened, but most had significant side effects. But there is increasing evidence that significant radioprotective benefit is achieved by increasing the dietary intake of foods with high antioxidant potential. Early plant-growing systems for space missions will be limited in both size and volume to minimize power and mass requirements. These systems will be well suited to producing plants containing high concentrations of bioprotective antioxidants. This project explored whether the production of bioprotective compounds could be increased by altering the lighting system, without increasing the space or power requirements for production, and evaluated the effects of environmental conditions (light quantity, light quality, and carbon dioxide [CO2] concentration) on the production of bioprotective compounds in lettuce, which provide a biological countermeasure for radiation exposure. The specific deliverables were to develop a database of bioprotectant compounds in plants that are suitable for use on longduration space missions, develop protocols for maintaining and increasing bioprotectant production under light emitting diodes (LEDs), recommend lighting requirements to produce dietary countermeasures of radiation, and publish results in the Journal of the American Society for Horticultural Science.

Source record↗

A hole modulator for InGaN/GaN light-emitting diodes

The low p-type doping efficiency of the p-GaN layer has severely limited the performance of InGaN/GaN light-emitting diodes (LEDs) due to the ineffective hole injection into the InGaN/GaN multiple quantum well (MQW) active region. The essence of improving the hole injection efficiency is to increase the hole concentration in the p-GaN layer. Therefore, in this work, we have proposed a hole modulator and studied it both theoretically and experimentally. In the hole modulator, the holes in a remote p-type doped layer are depleted by the built-in electric field and stored in the p-GaN layer. By this means, the overall hole concentration in the p-GaN layer can be enhanced. Furthermore, the hole modulator is adopted in the InGaN/GaN LEDs, which reduces the effective valance band barrier height for the p-type electron blocking layer from ∼332 meV to ∼294 meV at 80 A/cm{sup 2} and demonstrates an improved optical performance, thanks to the increased hole concentration in the p-GaN layer and thus the improved hole injection into the MQWs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge Separation of Wurtzite/Zinc-blende Heterojunction GaN Nanowires

The electronic properties of wurtzite/zinc-blende (WZ/ZB) heterostructure GaN are investigated using first-principles methods. A small component of ZB stacking formed along the growth direction in the WZ GaN nanowires does not show a significant effect on the electronic property, whereas a charge separation of electrons and holes occurs along the directions perpendicular to the growth direction in the ZB stacking. The later case provides an efficient way to separate the charge through controlling crystal structure. These results should have significant implications for most state of the art excitonic solar cells and the tuning region in tunable laser diodes.

14 SOLAR ENERGY↗

Realization of BaZrS 3 chalcogenide perovskite thin films for optoelectronics

BaZrS 3 is a prototypical chalcogenide perovskite, an emerging class of unconventional semiconductor. Recent results on powder samples reveal that it is a material with a direct band gap of 1.7–1.8 eV, a very strong light-matter interaction, and a high chemical stability. Due to the lack of quality thin films, however, many fundamental properties of chalcogenide perovskites remain unknown, hindering their applications in optoelectronics. In this work, we report the fabrication of BaZrS 3 thin films, by sulfurization of oxide films deposited by pulsed laser deposition. We show that these films are n-type with carrier densities in the range of 10 19 -10 20 cm -3 . Depending on the processing temperature, the Hall mobility ranges from 2.1 to 13.7 cm 2 /Vs. The absorption coefficient is > 10 5 cm -1 at photon energy >1.97 eV. Temperature dependent conductivity measurements suggest shallow donor levels. By assuring that BaZrS 3 is a promising candidate, these results potentially unleash the family of chalcogenide perovskites for optoelectronics such as photodetectors, photovoltaics, and light emitting diodes.

36 MATERIALS SCIENCE↗

Time-resolved study of the extreme-ultraviolet emission and plasma dynamics of a sub-Joule, fast capillary discharge

In this work, we discuss experimental observations on the dynamics of a fast, low energy capillary discharge when operated in argon and its properties as an intense source of extreme-ultraviolet (EUV) radiation. The discharge pre-ionization and self-triggering were accomplished by the use of the hollow cathode effect. This allowed a compact size and low inductance discharge with multi-kA current level and a quarter-period of ∼10 ns at sub-Joule energy level. We used the novel moiré and schlieren diagnostics with a 12 ps laser to obtain the time evolution of the line electron density and to study the plasma dynamics. EUV spectroscopy and filtered diodes were also implemented to estimate the plasma temperature and density throughout the evolution of the discharge. EUV source size was measured by using a filtered slit-wire camera. We observed that EUV emission starts from a compressed plasma on axis during the second quarter-period of the current and continues until the fifth quarter-period. Ionization levels from Ar VII to X were observed. By comparing the EUV emission spectra with synthetic spectra, we found that at the onset of emission (∼7 ns), the plasma is well fitted by a single Maxwellian electron distribution function with T{sub e} ∼ 12 eV and n{sub e} ∼ 10{sup 17 }cm{sup −3}. Close to peak emission (∼13 ns), plasma temperature and density increase to ∼20 eV and n{sub e} ∼ 10{sup 18 }cm{sup −3}, respectively. However, in order to successfully match the experimental data, a two component electron distribution function was necessary. Later in time, a smaller fraction in the high energy component and higher temperature suggests homogenization of the plasma. The moiré and schlieren diagnostics showed multiple radial compression-waves merging on axis throughout the discharge; they are an important heating mechanism that leads to a period of severe turbulence at peak EUV emission. It was also observed that emission ceases when the axial maximum of the electron density collapses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature-Dependent Characterization, Modeling, and Switching Speed-Limitation Analysis of Third-Generation 10-kV SiC MOSFET

The temperature-dependent characteristics of the third-generation 10-kV/20-A SiC MOSFET including the static characteristics and switching performance are carried out in this paper. The steady-state characteristics, including saturation current, output characteristics, antiparallel diode, and parasitic capacitance, are tested. Here, a double pulse test platform is constructed including a circuit breaker and gate drive with >10-kV insulation and also a hotplate under the device under test for temperature-dependent characterization during switching transients. The switching performance is tested under various load currents and gate resistances at a 7-kV dc-link voltage from 25 to 125 C and compared with previous 10-kV MOSFETs. A simple behavioral model with its parameter extraction method is proposed to predict the temperature-dependent characteristics of the 10-kV SiC MOSFET. The switching speed limitations, including the reverse recovery of SiC MOSFET's body diode, overvoltage caused by stray inductance, crosstalk, heat sink, and electromagnetic interference to the control are discussed based on simulations and experimental results.

10-kV silicon carbide (SiC) metal–oxide–semiconduc↗