Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

EdgeCortix SAKURA-I Machine-Learning, PCIe Accelerator SEE Heavy Ion Test Report

To enable autonomy in space, machine-learning and computer vision applications become invaluable for sensor processing. However, these algorithms are computationally complex and unfeasible for many embedded central processing units (CPUs) and usually require external coprocessors, such as graphics processing units (GPUs) or accelerators specific to the application, including application specific integrated circuits (ASICs). In power-constrained systems, GPUs tend to consume more power than is acceptable (>40W), so lower-power accelerators have shown promise to provide the performance needed under spacecraft constraints. For radiation engineers, developing methodologies that can properly test CPUs, GPUs, and accelerators, and enable comparisons between them remains a necessary complication to solve as the devices become more complex. The methodology in this test aims to be a start in developing a baseline single-event effect (SEE) test for client-device machine learning accelerators. This category of devices do not host their own operating system. This testing campaign is a continuation of a previous 200 MeV proton test performed in January 2024. This report covers two heavy ion tests of the SAKURA-I card: one in April 2024, and one in June 2024. Additional data was needed after the April test due to ion-range issues experienced at higher linear-energy transfers (LETs). These range issues are described in more detail in Section 8. This experiment characterizes SEEs and data error susceptibility of the EdgeCortix SAKURA-I machine-learning accelerator under heavy ions. The device was monitored for single event upsets (SEUs) and single event functional interrupts (SEFIs) at the Lawrence Berkeley National Laboratory’s 88-inch cyclotron. The SAKURA-I board accelerates machine-learning inference applications on a host computer through a PCIex16 connection. For the purposes of devising an end to end automated analysis workflow for this experiment, the YOLO-V5 and SSD300 objection-detection models, and the ResNet-50, EfficientNet, and MobileNetV2 image classification models were used as a representative suite of analytical machine-learning models.

Seth S Roffe↗

Thermionic energy conversion technology - Present and future

Aerospace and terrestrial applications of thermionic direct energy conversion and advances in direct energy conversion (DEC) technology are surveyed. Electrode materials, the cesium plasma drop (the difference between the barrier index and the collector work function), DEC voltage/current characteristics, conversion efficiency, and operating temperatures are discussed. Attention is centered on nuclear reactor system thermionic DEC devices, for in-core or out-of-core operation. Thermionic fuel elements, the radiation shield, power conditions, and a waste heat rejection system are considered among the thermionic DEC system components. Terrestrial applications include topping power systems in fossil fuel and solar power generation.

Shimada, K.↗

Carbon Nanotube-Based Digital Vacuum Electronics and Miniature Instrumentation for Space Exploration

JPL has developed high performance cold cathodes using arrays of carbon nanotube bundles that produce > 15 A/sq cm at applied fields of 5 to 8 V/micron without any beam focusing. They have exhibited robust operation in poor vacuums of 10(exp -6) to 10(exp -4) Torr- a typically achievable range inside hermetically sealed microcavities. Using these CNT cathodes JPL has developed miniature X-ray tubes capable of delivering sufficient photon flux at acceleration voltages of <20kV to perform definitive mineralogy on planetary surfaces; mass ionizers that offer two orders of magnitude power savings, and S/N ratio better by a factor of five over conventional ionizers. JPL has also developed a new class of programmable logic gates using CNT vacuum electronics potentially for Venus in situ missions and defense applications. These digital vacuum electronic devices are inherently high-temperature tolerant and radiation insensitive. Device design, fabrication and DC switching operation at temperatures up to 700 C are presented in this paper.

Carbon Nanotube↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced underwater lift device

Flexible underwater lift devices ('lift bags') are used in underwater operations to provide buoyancy to submerged objects. Commercially available designs are heavy, bulky, and awkward to handle, and thus are limited in size and useful lifting capacity. An underwater lift device having less than 20 percent of the bulk and less than 10 percent of the weight of commercially available models was developed. The design features a dual membrane envelope, a nearly homogeneous envelope membrane stress distribution, and a minimum surface-to-volume ratio. A proof-of-concept model of 50 kg capacity was built and tested. Originally designed to provide buoyancy to mock-ups submerged in NASA's weightlessness simulators, the device may have application to water-landed spacecraft which must deploy flotation upon impact, and where launch weight and volume penalties are significant. The device may also be useful for the automated recovery of ocean floor probes or in marine salvage applications.

Flanagan, David T.↗

Stirling Cooler Designed for Venus Exploration

Venus having an average surface temperature of 460 degrees Celsius (about 860 degrees Fahrenheit) and an atmosphere 150 times denser than the Earth's atmosphere, designing a robot to merely survive on the surface to do planetary exploration is an extremely difficult task. This temperature is hundreds of degrees higher than the maximum operating temperature of currently existing microcontrollers, electronic devices, and circuit boards. To meet the challenge of Venus exploration, researchers at the NASA Glenn Research Center studied methods to keep a pressurized electronics package cooled, so that the operating temperature within the electronics enclosure would be cool enough for electronics to run, to allow a mission to operate on the surface of Venus for extended periods.

Landis, Geoffrey A.↗

Exploring the effects of molecular beam epitaxy growth characteristics on the temperature performance of state-of-the-art terahertz quantum cascade lasers

This study conducts a comparative analysis, using non-equilibrium Green’s functions (NEGF), of two state-of-the-art two-well (TW) Terahertz Quantum Cascade Lasers (THz QCLs) supporting clean 3-level systems. The devices have nearly identical parameters and the NEGF calculations with an abrupt-interface roughness height of 0.12 nm predict a maximum operating temperature (T max ) of ~ 250 K for both devices. However, experimentally, one device reaches a T max of ~ 250 K and the other a T max of only ~ 134 K. Both devices were fabricated and measured under identical conditions in the same laboratory, with high quality processes as verified by reference devices. The main difference between the two devices is that they were grown in different MBE reactors. Our NEGF-based analysis considered all parameters related to MBE growth, including the maximum estimated variation in aluminum content, growth rate, doping density, background doping, and abrupt-interface roughness height. From our NEGF calculations it is evident that the sole parameter to which a drastic drop in T max could be attributed is the abrupt-interface roughness height. We can also learn from the simulations that both devices exhibit high-quality interfaces, with one having an abrupt-interface roughness height of approximately an atomic layer and the other approximately a monolayer. However, these small differences in interface sharpness are the cause of the large performance discrepancy. This underscores the sensitivity of device performance to interface roughness and emphasizes its strategic role in achieving higher operating temperatures for THz QCLs. We suggest Atom Probe Tomography (APT) as a path to analyze and measure the (graded)-interfaces roughness (IFR) parameters for THz QCLs, and subsequently as a design tool for higher performance THz QCLs, as was done for mid-IR QCLs. Our study not only addresses challenges faced by other groups in reproducing the record T max of ~ 250 K and ~ 261 K but also proposes a systematic pathway for further improving the temperature performance of THz QCLs beyond the state-of-the-art.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Custom Integration of Multiple Medical Functionalities

INTRODUCTION: Previous spaceflight experience and results from probabilistic risk assessment of spaceflight medical risk have highlighted the need for vital sign measurements, medical scopes, and clinical imaging tools for managing medical conditions during spaceflight. The Human Research Program’s Exploration Medical Capability (ExMC) Element and the Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) have performed ground-based evaluations of two Commercial-off-the-Shelf (COTS) Multi-functional Integrated Medical (MIM) devices, which integrate various medical capabilities together in one device. The key findings from these evaluations are presented in a complementary presentation, leaving this presentation to focus on forward recommendations for customized integration of multiple medical functionalities. KEY COMPONENTS: The key features of a custom integration of multiple medical functionalities includes devices and capabilities that optimally reduce medical risk. The COTS MIM devices incorporated functionality for best supporting Earth-based, emergency, pre-hospital care. Our custom integration will use probabilistic risk assessment tools, such as the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT), to determine the optimal functionality to include based on medical risk minimization. An additional feature of custom integration includes the ability to adapt to different requirements within different vehicles and/or missions. The COTS MIM devices store data in patient specific records, however, the format of the records is not modifiable, and data are not easily transferred from the MIM device to a central data architecture outside of the manufacturer’s established system. Our concept for custom integration will use devices that have an open application programming interface, which can easily connect to independent data architectures and third-party visualization software. The ultrasound capabilities included within the COTS MIM devices did not satisfy many of the Artemis Research and Operations Working Group’s ultrasound functional needs, and therefore, incorporation of higher quality ultrasound capabilities within a customized integration will be beneficial. The COTS MIM devices included minimal procedural guidance and clinical decision support tools. Supplemental tools of this type would need to be supplied along with the COTS MIM devices if they were to be used operationally, so another advantage of customization is the ability to integrate these support tools along with the medical functionality, for a more streamlined user experience. CONCLUSION: Investigation of a customized integration of medical functionality provides a method for further understanding the needs of a long-term exploration spaceflight medical system. The crew members of these exploration missions will need to operate more and more independently from Earth-based ground support. Therefore, having an optimized, streamlined medical system, which contains the functionality and supporting information needed, while remaining within mission and vehicle constraints, will help to maintain crew health and performance, which is necessary for achieving high levels of mission success.

B E Lewandowski↗

Transverse Mode Dynamics of VCSELs Through Space-Time Domain Simulation

Modeling and simulation are important to understand laser operation and to optimize and design device functions. Numerical simulation of VCSEL (Vertical Cavity Surface Emitting Lasers) has been largely based on solving time-independent Helmholtz equation or time dependent coupled mode equations. There are various advantages for choosing these approaches. However, the disadvantages are also apparent. The former cannot handle dynamical mode competition seen in VCSELs, while the latter assumes a given type and number of modes a priori. Furthermore, the microscopic physics of heterstructures and electron-hole plasma is very often represented by a few parameters such as linear gain coefficients and the linewidth enhancement factor. These are over simplification of space and frequency (wavelength) dependent gain and refractive index functions. When the space-time dynamical operation of VCSELs becomes important, these simple approximations become questionable. In this paper, we apply a recently developed model for edge-emitting lasers to a gain guided VCSEL for space-time domain simulation. This model takes into account the actual nonlinear dependence of gain and refractive index on frequency and carrier density within the frame work of the effective Bloch equations. The corresponding partial differential equations are solved directly by finite difference methods. Laser behavior with increasing pumping current is investigated in detail. Special attention is paid to the dynamical competition of the transverse modes.

Goorjian, Peter M.↗

Nanocoral Ag for nonenzymatic glucose detection at extremely low operational potential

Silver (Ag) metal has excellent antibacterial properties, which makes it an ideal candidate for nonenzymatic glucose sensing devices. However, Ag nonenzymatic glucose sensors function at significantly high operating potential and suffer from poor selectivity. Here, we report that nanocoral reduced Ag (R-Ag) based nonenzymatic glucose sensors can be operated at potential as low as 0.1 V vs. Ag/AgCl and exhibits more than one order magnitude higher sensitivity in comparison to the Ag film. The R-Ag sensors can detect glucose in a wide range of concentrations varying from 100 u M to 2.5 mM linearly. Finally, the R-Ag sensors are also very robust, as performance remains unchanged even if sensors are stored under ambient conditions for 45 days.

36 MATERIALS SCIENCE↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

AlGaAs/InGaAs heterostructures with doped channels for discrete devices and monolithic amplifiers

AlGaAs/InGaAs/GaAs-type heterostructure with one or two doped channels have been used to fabricate both discrete devices and monolithic amplifiers for millimeter-wave operation. Maximum current densities of 1 A/mm and maximum transconductances of 530 mS/mm were obtained. 0.25 x 50 micron discrete devices delivered a power density of 1 W/mm with 2.9-dB gain and 25 percent efficiency at 60 GHz. A 100-micron monolithic one-stage amplifier demonstrated 93 mW (0.93-W/mm power density) at 31.5 GHz with 4.2-dB gain and 29 percent efficiency. A record 34 percent efficiency was achieved with a 53.7-mW output power and 4.8-dB gain.

Saunier, Paul↗

The impact of non-ideal phase change properties on phase change thermal energy storage device performance

Phase change materials have been known to improve the performance of energy storage devices by shifting or reducing thermal/electrical loads. While an ideal phase change material is one that undergoes a sharp, reversible phase transition, real phase change materials do not exhibit this behavior and often have one or more non-idealities – glide, hysteresis, supercooling – associated with them. Experimental and modeling techniques to characterize these non-ideal properties are reasonably well understood, however, their impact on the performance of a thermal energy storage system is not fully understood. Herein, we analyze the performance of a heat exchanger with a phase change material as a function of the different non-idealities, for a heating and a cooling application. We focus on the impact of these non-ideal behaviors on different modes of operation of the thermal energy storage device, which will serve as a useful guide to researchers on the relative importance of the non-ideal properties, along with the necessary accuracy required during an experimental characterization.

25 ENERGY STORAGE↗

Overcoming the sensitivity vs. throughput tradeoff in Coulter counters: A novel side counter design

We report microfabricated Coulter counters are attractive for point of care (POC) applications since they are label free and compact. However, these approaches inherently suffer from a trade off between sample throughput and sensitivity. The counter measures a change in impedance due to displaced fluid volume by passing cells, and thus the counter's signal increases with the fraction of the sensing volume displaced. Reducing the size of the sensing region requires reductions in volumetric throughput in the absence of increased hydraulic pressure and sensor bandwidth. The risk of mechanical clog formation, rendering the counter inoperable, increases markedly with reductions in the size of the constriction aperture. We present here a microfluidic coplanar Coulter counter device design that overcomes the problem of constriction clogging while capable of operating in microfluidic channels filled entirely with highly conductive sample. The device utilizes microfabricated planar electrodes projecting into one side of the microfluidic channel and is easily integrated with upstream electronic, hydrodynamic, or other focusing units to produce efficient counting which could allow for dramatically increased volumetric and sample throughput. The design lends itself to simple, cost effective POC applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchro phase selector aid

Phase selector permits multiple leads of synchro devices to be randomly connected while proper interconnections are determined by operating selector switches. Operation of these switches varies both phase and rotation relationship of synchro devices.

Austin, F. H.↗

Direct-current polarization characteristics of various AlGaAs laser diodes

Polarization characteristics of AlGaAs laser diodes having various device geometries have been measured. Measurements were performed with the laser diodes operating under dc conditions. Results show that laser diodes having different device geometries have optical outputs that exhibit varying degrees of polarization purity. Implications of this result, with respect to incoherent polarization-beam combining, are addressed.

Fuhr, P. L.↗

Evaluation of fuel preparation systems for lean premixing-prevaporizing combustors

A series of experiments was carried out in order to produce design data for a premixing prevaporizing fuel-air mixture preparation system for aircraft gas turbine engine combustors. The fuel-air mixture uniformity of four different system design concepts was evaluated over a range of conditions representing the cruise operation of a modern commercial turbofan engine. Operating conditions including pressure, temperature, fuel-to-air ratio, and velocity, exhibited no clear effect on mixture uniformity of systems using pressure-atomizing fuel nozzles and large-scale mixing devices. However, the performance of systems using atomizing fuel nozzles and large-scale mixing devices was found to be sensitive to operating conditions. Variations in system design variables were also evaluated and correlated. Mixing uniformity was found to improve with system length, pressure drop, and the number of fuel injection points per unit area. A premixing system capable of providing mixing uniformity to within 15 percent over a typical range of cruise operating conditions is demonstrated.

Dodds, W. J.↗

Overview of Wendelstein 7-X high-performance operation

The Wendelstein 7-X (W7-X) stellarator has completed two consecutive experimental campaigns OP 2.2 (Sep.-Dec. 2024) and OP 2.3 (Feb.-May 2025) under a new operational strategy enabling more than one year of uninterrupted device availability. This approach, supported by exceptionally high subsystem reliability, allowed sustained high-efficiency plasma operations with up to 80–100 discharges per day across a broad range of magnetic configurations. Several key technical upgrades-most notably the first operation of a 1.5 MW class steady-state gyrotron, a new steady-state pellet injector, and advanced real-time feedback control systems significantly enhanced heating, fueling, and plasma control capabilities. Together, these improvements enabled major advances in long-pulse performance, high-β operation, and confinement optimization. Long-pulse discharges achieved 1.8 GJ of injected energy under fully detached divertor conditions, while reduced-field scenarios facilitated record volume-averaged β values approaching 3%. High-performance plasmas with centrally peaked density profiles, created via neutral beam injection (NBI) or sustained pellet fueling, demonstrated strongly reduced turbulent transport and stellarator-record fusion triple products. Complementary studies of power exhaust and divertor heat loads revealed the role of scrape-off-layer drift physics in shaping strike-line patterns under attached conditions. Together, the results from OP 2.2 and OP 2.3 significantly expand the operational space of W7-X and strengthen its role as a leading platform for steady-state stellarator research and reactor-relevant plasma scenarios.

Wendelstein 7-X↗