Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Tailoring electrode microstructure via ink content to enable improved rated power performance for platinum cobalt/high surface area carbon based polymer electrolyte fuel cells

Improvements in polymer electrolyte fuel cell (PEFC) electrode performance have primarily focused on catalyst and ionomer developments, marginalizing the importance of catalyst ink formulation. In this study, the effect of ink formulation is examined across a series of cathodes comprised of PtCo supported on high surface area carbon (PtCo/ HSC ) and Nafion ionomer using an array of in situ electrochemical and ex situ characterization techniques. In contrast to prior work on Pt/Vu systems, ink water content had little effect on the electrochemically determined ionomer coverage for the PtCo/HSC electrocatalyst examined here. Characterization using nano-scale resolution X-ray computed tomography (nano-CT) demonstrated that water-rich ink formulations lead to a reduction in aggregate size (ionomer + PtCo/HSC), improving local O 2 transport. This understanding, combined with the use of a commercially-available electrocatalyst was used to produced state-of-the-art membrane electrode assemblies with Pt loadings of 0.03/0.08 mg Pt /cm 2 on the anode and cathode respectively, having; i) > 1 A/mg Pt (0.9 V iR-free , 150 kPa, 80 °C, 100% RH, H 2 /O 2 ), ii) 320 mA/cm 2 at 0.8 V, 150 kPa, 80 ° C, 100% RH, H 2 /Air), and iii) > 1 W/cm 2 elec at rated power (0.67 V, 250 kPa, 94 °C, 65% RH, H 2 /Air) or < 0.11 g Pt /kW rated .

25 ENERGY STORAGE↗

The HITRAN2016 molecular spectroscopic database

This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is comprised of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 200 additional significant molecules have been added to the database.

Gordon, I. E.↗

Fabrication of oriented zeolite L monolayer via covalent molecular linkers

For the first time, 1,4-diisocyanatobutane (DICB) was used as the covalent molecular linker in this study to prepare the uniformly oriented zeolite L monolayer with relatively high coverage degree and close packing degree. This could be ascribed to substantial amounts of DICB self-assemble and standing on the substrate surface instead of folding up into a U-shape. This point has been further verified by the quality of oriented zoelite L monolayers obtained from the procedure involving DICB, 1, 4-bis (triethoxysilyl) benzene (BTSEB) and 1,2-bis(trimethoxysilyl)ethane (BTMSE) as covalent molecular linkers. - Graphical abstract: 1, 4-diisocyanatobutane (DICB) was used as the covalent molecular linker in this study to prepare the uniformly oriented zeolite L monolayer with a relatively high coverage degree and close packing degree. This could be ascribed to substantial amounts of DICB self-assemble and standing on the substrate surface instead of folding up into a U-shape. This point has been further verified by the quality of oriented zoelite L monolayers obtained from the procedure involving DICB, 1, 4-bis (triethoxysilyl) benzene (BTSEB) and 1,2-bis(trimethoxysilyl)ethane (BTMSE) as covalent molecular linkers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The “quiet Goldschmidt”—a mechanochemical, thermoanalytical, and spectroscopic study of selected steps of the aluminothermic reaction

The Goldschmidt reaction (2Al+α-Fe{sub 2}O{sub 3}) was investigated both under mechanical and thermal activation by employing a combination of analytical methods such as ESR and Mössbauer spectroscopy, magnetic susceptibility, X-ray powder diffraction, and thermal analysis (TA). Both the mechanical treatment and the TA runs under air caused the reaction conditions of “quiet redox reactions” due to a retarding effect and enabled a reaction study in a “slow motion mode”. This allowed to establish distinct partial steps of the integral reaction process depending on the intensity of the mechanical impact, the educt composition, the gas phase composition, and, finally, the thermal excitation in the TA runs. Particular attention was payed to the role of the gas phase and to the reaction of aluminum with differently activated oxygen species. The phlegmatizing effect was traced back to the formation of Al{sub 2}O{sub 3} coverages of the Al particles. - Highlights: • The usually extremely violent Goldschmidt reaction was studied in a “slow motion mode”. • Both the mechanochemical and the thermal treatment caused a phlegmatizing effect on the reaction. • Early reaction stages were sensitively indicated by ESR and magnetic measurements. • Intermediates and final products were characterized by XRD and Mössbauer data. • Differently activated oxygen species react with aluminum to form an oxide coverage retarding the vigorous reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of annealing conditions on the formation of hollow Al{sub 2}O{sub 3} microspheres studied by in situ ESEM

The transformation of Al microparticles into hollow and broken Al{sub 2}O{sub 3} microspheres was investigated by in situ environmental scanning electron microscopy (ESEM) up to 1150 °C under different heating rates and 120 Pa of gas atmospheres. Slow heating rates (2 °C min{sup −1}) resulted in a better coverage of the particles shell than with fast heating rates (20 °C min{sup −1}) that delayed the threshold temperature at which the particles opened. Above this threshold, the amount of opened spheres increased with heating rate, with the coarser particles opening more than the small ones. It appeared that inert atmospheres (He–4%H{sub 2}) increased the temperature at which the particles transformed, while air and pure oxygen tended to lower it. In contrast, the temperature interval was larger and was size-dependent when using water vapour. Irrespective of the gas atmosphere, opening of the spheres allowed molten Al to flow out from the core and aluminise the substrate while leaving behind a top coat of hollow alumina spheres. - Graphical abstract: (a) Effect of the increasing of oxidizing power of the gas atmosphere and of the heating rate. The former provokes in a better surface coverage of the Al microparticles while the latter results in thinner alumina shells. (b) The supply of Al to the substrate and the interdiffusion mechanisms result in an aluminised layer underneath the top coat of Al microparticles. - Highlights: • Transformations of Al microparticles with temperature demonstrated by in-situ SEM • The gas atmospheres changed the temperature of transformation of the Al microparticles. • The Al supply from the microparticles aluminized the superalloy substrate. • A potential thermal barrier coating was thus obtained in a single step process.

36 MATERIALS SCIENCE↗

Effect of microstructure on exfoliation corrosion resistance in an Al-Zn-Mg alloy

Highlights: • A quantitative method was proposed to characterize EXCO resistance. • The EXCO product lead to strain in ND and elongation in RD on nearby grains. • Recrystallized grains are more susceptible to EXCO than fibrous grains. • High fraction of high-angle grain boundaries reduces EXCO resistance. • High coverage ratio of η phases on high-angle grain boundaries reduces EXCO resistance. - Abstract: In this work, the effect of microstructure on exfoliation corrosion (EXCO) resistance in an Al-Zn-Mg alloy were investigated using standard EXCO test, together with detailed microstructural examinations mainly by scanning electron microscopy (SEM) and high-angle annular detector dark-field scanning transmission electron microscopy (HAADF-STEM). An EXCO product model was built based on morphologies of EXCO product on longitudinal section and cross section for further measurement and analysis. A quantitative characterization of EXCO resistance by measuring average thickness of EXCO product was conducted, showing average results of 6.94 μm, 10.21 μm and 18.14 μm, which are corresponding to EXCO ratings of P, EA and EB under ASTM G34 standard, respectively. It was concluded that recrystallization, high fraction of high-angle grain boundaries (HAGBs) and high coverage ratio of η phases on HAGBs reduced EXCO resistance.

36 MATERIALS SCIENCE↗

Feasibility Study of Intensity-Modulated Radiotherapy (IMRT) Treatment Planning Using Brain Functional MRI

The purpose of this work was to study the feasibility of incorporating functional magnetic resonance imaging (fMRI) information for intensity modulated radiotherapy (IMRT) treatment planning of brain tumors. Three glioma patients were retrospectively replanned for radiotherapy (RT) with additional fMRI information. The fMRI of each patient was acquired using a bilateral finger-tapping paradigm with a gradient echo EPI (Echo Planer Imaging) sequence. The fMRI data were processed using the Analysis of Functional Neuroimaging (AFNI) software package for determining activation volumes, and the volumes were fused with the simulation computed tomography (CT) scan. The actived pixels in left and right primary motor cortexes (PMCs) were contoured as critical structures for IMRT planning. The goal of replanning was to minimize the RT dose to the activation volumes in the PMC regions, while maintaining a similar coverage to the planning target volume (PTV) and keeping critical structures within accepted dose tolerance. Dose-volume histograms of the treatment plans with and without considering the fMRI information were compared. Beam angles adjustment or additional beams were needed for 2 cases to meet the planning criteria. Mean dose to the contralateral and ipsilateral PMC was significantly reduced by 66% and 55%, respectively, for 1 patient. For the other 2 patients, mean dose to contralateral PMC region was lowered by 73% and 69%. In general, IMRT optimization can reduce the RT dose to the PMC regions without compromising the PTV coverage or sparing of other critical organs. In conclusion, it is feasible to incorporate the fMRI information into the RT treatment planning. IMRT planning allows a significant reduction in RT dose to the PMC regions, especially if the region does not lie within the PTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Radiotherapy for Gastric Cancer: A Dosimetric Comparison of 3-Dimensional Conformal Radiotherapy, Tomotherapy (registered) and Conventional Intensity Modulated Radiotherapy Treatment Plans

Some patients with gastric cancer benefit from post-operative chemo-radiotherapy, but adequately irradiating the planning target volume (PTV) whilst avoiding organs at risk (OAR) can be difficult. We evaluate 3-dimensional conformal radiotherapy (CRT), conventional intensity-modulated radiotherapy (IMRT) and helical tomotherapy (TT). TT, 2 and 5-field (F) CRT and IMRT treatment plans with the same PTV coverage were generated for 5 patients and compared. Median values are reported. The volume of left/right kidney receiving at least 20Gy (V20) was 57/51% and 51/60% for 2 and 5F-CRT, and 28/14% for TT and 27/19% for IMRT. The volume of liver receiving at least 30Gy (V30) was 45% and 62% for 2 and 5F-CRT, and 37% for TT and 35% for IMRT. With TT, 98% of the PTV received 95-105% of the prescribed dose, compared with 45%, 34% and 28% for 2F-CRT, 5F-CRT and IMRT respectively. Using conventional metrics, conventional IMRT can achieve comparable PTV coverage and OAR sparing to TT, but at the expense of PTV dose heterogeneity. Both irradiate large volumes of normal tissue to low doses. Additional studies are needed to demonstrate the clinical impact of these technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic and Dosimetric Changes During the Treatment Course of Intensity-Modulated Radiotherapy for Locally Advanced Nasopharyngeal Carcinoma

Many patients with nasopharyngeal carcinoma (NPC) have marked anatomic change during intensity-modulated radiation therapy (IMRT). In this study, the magnitude of anatomic changes and its dosimetric effects were quantified. Fifteen patients with locally advanced NPC treated with IMRT had repeated computed tomography (CT) after 18 fractions. A hybrid plan was made to the anatomy of the second computed tomography scan. The dose of the original plan, hybrid plan, and new plan were compared. The mean volume of left and right parotid decreased 6.19 mL and 6.44 mL, respectively. The transverse diameters of the upper bound of odontoid process, the center of odontoid process, and the center of C2 vertebral body slices contracted with the mean contraction of 8.2 mm, 9.4 mm, and 7.6 mm. Comparing the hybrid plan with the treatment plan, the coverage of target was maintained while the maximum dose to the brain stem and spinal cord increased by 0.08 to 6.51 Gy and 0.05 to 7.8 Gy. The mean dose to left and right parotid increased by 2.97 Gy and 2.57 Gy, respectively. A new plan reduced the dose of spinal cord, brain stem, and parotids. Measurable anatomic changes occurring during the IMRT for locally advanced NPC maintained the coverage of targets but increased the dose to critical organs. Those patients might benefit from replanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Sparing of Brainstem and Spinal Cord for Re-Irradiating Recurrent Head and Neck Cancer with Intensity-Modulated Radiotherapy

Because of the dose limit for critical structures such as brainstem and spinal cord, administering a dose of 60 Gy to patients with recurrent head and neck cancer is challenging for those who received a previous dose of 60-70 Gy. Specifically, previously irradiated head and neck patients may have received doses close to the tolerance limit to their brainstem and spinal cord. In this study, a reproducible intensity-modulated radiation therapy (IMRT) treatment design is presented to spare the doses to brainstem and spinal cord, with no compromise of prescribed dose delivery. Between July and November 2008, 7 patients with previously irradiated, recurrent head and neck cancers were treated with IMRT. The jaws of each field were set fixed with the goal of shielding the brainstem and spinal cord at the sacrifice of partial coverage of the planning target volume (PTV) from any particular beam orientation. Beam geometry was arranged to have sufficient coverage of the PTV and ensure that the constraints of spinal cord <10 Gy and brainstem <15 Gy were met. The mean maximum dose to the brainstem was 12.1 Gy (range 6.1-17.3 Gy), and the corresponding mean maximum dose to spinal cord was 10.4 Gy (range 8.2-14.1 Gy). For most cases, 97% of the PTV volume was fully covered by the 95% isodose volume. We found empirically that if the angle of cervical spine curvature (Cobb's angle) was less than {approx}30{sup o}, patients could be treated by 18 fields. Six patients met these criteria and were treated in 25 minutes per fraction. One patient exceeded a 30{sup o} Cobb's angle and was treated by 31 fields in 45 minutes per fraction. We have demonstrated a new technique for retreatment of head and neck cancers. The angle of cervical spine curvature plays an important role in the efficiency and effectiveness of our approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Analysis of 3D Image-Guided HDR Brachytherapy Planning for the Treatment of Cervical Cancer: Is Point A-Based Dose Prescription Still Valid in Image-Guided Brachytherapy?

The purpose of this study was to analyze the dosimetric outcome of 3D image-guided high-dose-rate (HDR) brachytherapy planning for cervical cancer treatment and compare dose coverage of high-risk clinical target volume (HRCTV) to traditional Point A dose. Thirty-two patients with stage IA2-IIIB cervical cancer were treated using computed tomography/magnetic resonance imaging-based image-guided HDR brachytherapy (IGBT). Brachytherapy dose prescription was 5.0-6.0 Gy per fraction for a total 5 fractions. The HRCTV and organs at risk (OARs) were delineated following the GYN GEC/ESTRO guidelines. Total doses for HRCTV, OARs, Point A, and Point T from external beam radiotherapy and brachytherapy were summated and normalized to a biologically equivalent dose of 2 Gy per fraction (EQD2). The total planned D90 for HRCTV was 80-85 Gy, whereas the dose to 2 mL of bladder, rectum, and sigmoid was limited to 85 Gy, 75 Gy, and 75 Gy, respectively. The mean D90 and its standard deviation for HRCTV was 83.2 {+-} 4.3 Gy. This is significantly higher (p < 0.0001) than the mean value of the dose to Point A (78.6 {+-} 4.4 Gy). The dose levels of the OARs were within acceptable limits for most patients. The mean dose to 2 mL of bladder was 78.0 {+-} 6.2 Gy, whereas the mean dose to rectum and sigmoid were 57.2 {+-} 4.4 Gy and 66.9 {+-} 6.1 Gy, respectively. Image-based 3D brachytherapy provides adequate dose coverage to HRCTV, with acceptable dose to OARs in most patients. Dose to Point A was found to be significantly lower than the D90 for HRCTV calculated using the image-based technique. Paradigm shift from 2D point dose dosimetry to IGBT in HDR cervical cancer treatment needs advanced concept of evaluation in dosimetry with clinical outcome data about whether this approach improves local control and/or decreases toxicities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Results of Helical Tomotherapy in Patients with Complex-Shaped Meningiomas Close to the Optic Pathway

Meningiomas are the most common benign intracranial tumor. Meningiomas close to the optic pathway represent a treatment challenge both for surgery and radiotherapy. The aim of this article is to describe early results of helical tomotherapy treatment in complex-shaped meningiomas close to the optic pathway. Twenty-eight patients were consecutively treated. All patients were immobilized with a thermoplastic head mask and planned with the aid of a magnetic resonance imaging-computed tomography fusion. All treatments included daily image guidance. Pretreatment symptoms and acute toxicity were recorded. Median age was 57.5 years, and 92.8% patients had Eastern Cooperative Oncology Group performance status scale {<=}1. The most common localizations were the sella turcica, followed by the cavernous sinus and the sphenoid. The most common symptoms were derived from cranial nerve deficits. Tomotherapy was administered as primary treatment in 35.7% of patients, as an adjuvant treatment in 32.4%, and as a rescue treatment after postsurgical progression in 32.1% patients. Most patients were either inoperable or Simpson IV. Total dose varied between 5000 and 5400 cGy; fractionation varied between 180 and 200 cGy. Median dose to the planning target volume was 51.7 Gy (range, 50.2-55.9 Gy). Median coverage index was 0.89 (range, 0.18-0.97). Median homogeneity index was 1.05 (range, 1-1.12). Acute transient toxicity was grade 1 and included headache in 35.7% patients, ocular pain/dryness in 28.5%, and radiation dermatitis in 25%. Thus far, with a maximal follow-up of 3 years, no late effects have been seen and all patients have a radiological stabilization of the disease. Helical tomotherapy offered a safe and effective therapeutic alternative for patients with inoperable or subtotally resected complex-shaped meningiomas close to the optic pathway. Acceptable coverage and homogeneity indexes were achieved with appropriate values for maximal doses delivered to the eyes, lenses, and chiasm, despite the proximity of the tumor to these structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Comparison of RapidArc with Fixed Gantry Intensity-Modulated Radiotherapy Treatment for Multiple Liver Metastases Radiotherapy

We wanted to compare the dosimetric difference and treatment efficiency of RapidArc and fixed gantry intensity-modulated radiotherapy treatment (IMRT) for multiple liver metastases. Computed tomography datasets of 10 patients were studied retrospectively. IMRT plans were generated using 5 fields and RapidArc using either 1 or 2 arcs. The dose distribution of planning target volume (PTV), organs at risk (OARs), and the normal tissue were compared. Monitor units and treatment time were scored to measure expected treatment efficiency. Both RapidArc and IMRT plans resulted in equivalent target coverage. There was no statistically significant difference for the maximum and the minimum dose of PTV. RapidArc plans achieved an improved conformity index compared with IMRT (RA1 = 1.68 {+-} 0.27, RA2 = 1.61 {+-} 0.25, IMRT = 1.80 {+-} 0.37). For OARs, all techniques respected planning objectives. RapidArc plans had a lower dose in V{sub 40} of small bowel than IMRT, but were higher in mean dose of kidneys. Concerning the V{sub 5}, V{sub 10}, and V{sub 15} of healthy tissue, RapidArc plans were higher than IMRT. However, the V{sub 20}, V{sub 25}, and V{sub 30} of healthy tissue in RapidArc plans were lower than IMRT. Monitor units per fraction of RapidArc plans were about 40% or 46% of IMRT. Compared with IMRT plans, treatment time of RapidArc plans were reduced by 60% or 70%. All techniques respected planning objectives. RapidArc showed statistical improvements in conformity index and healthy tissue sparing with uncompromised target coverage. This, in combination with fewer monitor units and short delivery time, can lead to clinically significant advances for the treatment of multiple liver metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of MLC leaf width on the quality of the dose distribution in partial breast irradiation

Partial-breast irradiation (PBI) aims to limit the target volume for radiotherapy in women with early breast cancer after partial mastectomy to the region at highest risk of local recurrence, the tumor bed. Multileaf collimators are used to achieve conformal radiation beam portals required for PBI. Narrower leaf widths are generally assumed to allow more conformal shaping of beam portals around irregularly shaped target volumes. The aim was to compare 5-mm and 10-mm leaf widths for patients previously treated using PBI and assess subsequent planning target volume (PTV) coverage and organ at risk (OAR) doses for 16 patients. Several plans (5-mm leaf width or 10-mm leaf width) were generated for each patient using the original treated plan as the basis for attempts at further optimization. Alternating between different leaf widths found no significant difference in terms of overall PTV coverage and OAR doses between treatment plans. Optimization of the original treated plan allowed a small decrease in ipsilateral breast dose, which was offset by a lower PTV minimum. No significant dosimetric difference was found to support an advantage of 5-mm over 10-mm leaf width in this setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric modulated arc radiotherapy for esophageal cancer

A treatment planning study was performed to evaluate the performance of volumetric arc modulation with RapidArc (RA) against 3D conformal radiation therapy (3D-CRT) and conventional intensity-modulated radiation therapy (IMRT) techniques for esophageal cancer. Computed tomgraphy scans of 10 patients were included in the study. 3D-CRT, 4-field IMRT, and single-arc and double-arc RA plans were generated with the aim to spare organs at risk (OAR) and healthy tissue while enforcing highly conformal target coverage. The planning objective was to deliver 54 Gy to the planning target volume (PTV) in 30 fractions. Plans were evaluated based on target conformity and dose-volume histograms of organs at risk (lung, spinal cord, and heart). The monitor unit (MU) and treatment delivery time were also evaluated to measure the treatment efficiency. The IMRT plan improves target conformity and spares OAR when compared with 3D-CRT. Target conformity improved with RA plans compared with IMRT. The mean lung dose was similar in all techniques. However, RA plans showed a reduction in the volume of the lung irradiated at V{sub 20Gy} and V{sub 30Gy} dose levels (range, 4.62-17.98%) compared with IMRT plans. The mean dose and D{sub 35%} of heart for the RA plans were better than the IMRT by 0.5-5.8%. Mean V{sub 10Gy} and integral dose to healthy tissue were almost similar in all techniques. But RA plans resulted in a reduced low-level dose bath (15-20 Gy) in the range of 14-16% compared with IMRT plans. The average MU needed to deliver the prescribed dose by RA technique was reduced by 20-25% compared with IMRT technique. The preliminary study on RA for esophageal cancers showed improvements in sparing OAR and healthy tissue with reduced beam-on time, whereas only double-arc RA offered improved target coverage compared with IMRT and 3D-CRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Total dural irradiation: RapidArc versus static-field IMRT: A case study

The purpose of this study was to compare conventional fixed-gantry angle intensity-modulated radiation therapy (IMRT) with RapidArc for total dural irradiation. We also hypothesize that target volume-individualized collimator angles may produce substantial normal tissue sparing when planning with RapidArc. Five-, 7-, and 9-field fixed-gantry angle sliding-window IMRT plans were generated for comparison with RapidArc plans. Optimization and normal tissue constraints were constant for all plans. All plans were normalized so that 95% of the planning target volume (PTV) received at least 100% of the dose. RapidArc was delivered using 350 Degree-Sign clockwise and counterclockwise arcs. Conventional collimator angles of 45 Degree-Sign and 315 Degree-Sign were compared with 90 Degree-Sign on both arcs. Dose prescription was 59.4 Gy in 33 fractions. PTV metrics used for comparison were coverage, V{sub 107}%, D1%, conformality index (CI{sub 95}%), and heterogeneity index (D{sub 5}%-D{sub 95}%). Brain dose, the main challenge of this case, was compared using D{sub 1}%, Dmean, and V{sub 5} Gy. Dose to optic chiasm, optic nerves, globes, and lenses was also compared. The use of unconventional collimator angles (90 Degree-Sign on both arcs) substantially reduced dose to normal brain. All plans achieved acceptable target coverage. Homogeneity was similar for RapidArc and 9-field IMRT plans. However, heterogeneity increased with decreasing number of IMRT fields, resulting in unacceptable hotspots within the brain. Conformality was marginally better with RapidArc relative to IMRT. Low dose to brain, as indicated by V5Gy, was comparable in all plans. Doses to organs at risk (OARs) showed no clinically meaningful differences. The number of monitor units was lower and delivery time was reduced with RapidArc. The case-individualized RapidArc plan compared favorably with the 9-field conventional IMRT plan. In view of lower monitor unit requirements and shorter delivery time, RapidArc was selected as the optimal solution. Individualized collimator angle solutions should be considered by RapidArc dosimetrists for OARs dose reduction. RapidArc should be considered as a treatment modality for tumors that extensively involve in the skull, dura, or scalp.

61 RADIATION PROTECTION AND DOSIMETRY↗

Larynx-sparing techniques using intensity-modulated radiation therapy for oropharyngeal cancer

The purpose of the current study was to explore whether the laryngeal dose can be reduced by using 2 intensity-modulated radiation therapy (IMRT) techniques: whole-neck field IMRT technique (WF-IMRT) vs. junctioned IMRT (J-IMRT). The effect on planning target volumes (PTVs) coverage and laryngeal sparing was evaluated. WF-IMRT technique consisted of a single IMRT plan, including the primary tumor and the superior and inferior neck to the level of the clavicular heads. The larynx was defined as an organ at risk extending superiorly to cover the arytenoid cartilages and inferiorly to include the cricoid cartilage. The J-IMRT technique consisted of an IMRT plan for the primary tumor and the superior neck, matched to conventional antero-posterior opposing lower neck fields at the level of the thyroid notch. A central block was used for the anterior lower neck field at the level of the larynx to restrict the dose to the larynx. Ten oropharyngeal cancer cases were analyzed. Both the primary site and bilateral regional lymphatics were included in the radiotherapy targets. The averaged V95 for the PTV57.6 was 99.2% for the WF-IMRT technique compared with 97.4% (p = 0.02) for J-IMRT. The averaged V95 for the PTV64 was 99.9% for the WF-IMRT technique compared with 98.9% (p = 0.02) for J-IMRT and the averaged V95 for the PT70 was 100.0% for WF-IMRT technique compared with 99.5% (p = 0.04) for J-IMRT. The averaged mean laryngeal dose was 18 Gy with both techniques. The averaged mean doses within the matchline volumes were 69.3 Gy for WF-MRT and 66.2 Gy for J-IMRT (p = 0.03). The WF-IMRT technique appears to offer an optimal coverage of the target volumes and a mean dose to the larynx similar with J-IMRT and should be further evaluated in clinical trials.

61 RADIATION PROTECTION AND DOSIMETRY↗

Static jaw collimation settings to minimize radiation dose to normal brain tissue during stereotactic radiosurgery

At University of Arkansas for Medical Sciences (UAMS) intracranial stereotactic radiosurgery (SRS) is performed by using a linear accelerator with an add-on micromultileaf collimator (mMLC). In our clinical setting, static jaws are automatically adapted to the furthest edge of the mMLC-defined segments with 2-mm (X jaw) and 5-mm (Y jaw) margin and the same jaw values are applied for all beam angles in the treatment planning system. This additional field gap between the static jaws and the mMLC allows additional radiation dose to normal brain tissue. Because a radiosurgery procedure consists of a single high dose to the planning target volume (PTV), reduction of unnecessary dose to normal brain tissue near the PTV is important, particularly for pediatric patients whose brains are still developing or when a critical organ, such as the optic chiasm, is near the PTV. The purpose of this study was to minimize dose to normal brain tissue by allowing minimal static jaw margin around the mMLC-defined fields and different static jaw values for each beam angle or arc. Dose output factors were measured with various static jaw margins and the results were compared with calculated doses in the treatment planning system. Ten patient plans were randomly selected and recalculated with zero static jaw margins without changing other parameters. Changes of PTV coverage, mean dose to predefined normal brain tissue volume adjacent to PTV, and monitor units were compared. It was found that the dose output percentage difference varied from 4.9-1.3% for the maximum static jaw opening vs. static jaw with zero margins. The mean dose to normal brain tissue at risk adjacent to the PTV was reduced by an average of 1.9%, with negligible PTV coverage loss. This dose reduction strategy may be meaningful in terms of late effects of radiation, particularly in pediatric patients. This study generated clinical knowledge and tools to consistently minimize dose to normal brain tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗