Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Waveguide cooling system

An improved system is described for cooling high power waveguides by the use of cooling ducts extending along the waveguide, which minimizes hot spots at the flanges where waveguide sections are connected together. The cooling duct extends along substantially the full length of the waveguide section, and each flange at the end of the section has a through hole with an inner end connected to the duct and an opposite end that can be aligned with a flange hole in another waveguide section. Earth flange is formed with a drainage groove in its face, between the through hole and the waveguide conduit to prevent leakage of cooling fluid into the waveguide. The ducts have narrowed sections immediately adjacent to the flanges to provide room for the installation of fasteners closely around the waveguide channel.

Chen, B. C. J.↗

Cool luminous stars

The consequences of magnetic fields for the atmospheres of cool stars are addressed based on IUE and Einstein Observatory observations. Gross atmospheric structure data for cool luminous stars are discussed, and the relevance of the observations for the energy balance and nonradiative heating rates is considered. Data from X-ray fluxes, low dispersion UV spectra, and high dispersion spectra in the region of the Mg II resonance lines are presented. New results on cool star atmospheres provided by high dispersion UV spectra are considered, including those pertaining to spectral line identification, identification of emission components in close binary systems, densities and atmospheric extension, emission line widths, properties of stellar winds as derived from IUE data, and systematic flows of transition region plasma. An explanation for the observed spectra of cool giants and supergiants is proposed in terms of active, quiet, and hybrid stars.

Linsky, J. L.↗

Correlation of thermophoretically-modified small particle diffusional deposition rates in forced convection systems with variable properties, transpiration cooling and/or viscous dissipation

A cooled object (heat exchanger tube or turbine blade) is considered to be immersed in a hot fluid stream containing trace amounts of suspended vapors and/or small particles. Numerical prediction calculations were done for self-similar laminar boundary layers and law-of-the-wall turbulent boundary layers. Correlations are presented for the effect of thermophoresis in the absence of transpiration cooling and viscous dissipation; the effect of real suction and blowing in the absence of thermophoresis; the effect of viscous dissipation on thermophoresis in the absence of transpiration cooling; and the combined effect of viscous dissipation and transpiration cooling on thermophoresis. The final correlation, St/St-sub-zero, is insensitive to particle properties, Euler number, and local mainstream temperature.

Gokoglu, S. A.↗

Thermal investigation of an electrical high-current arc with porous gas-cooled anode

The following guantities were measured on a high-intensity electric arc with tungsten cathode and transpiration-cooled graphite anode burning in argon: electric current and voltage, cooling gas flow rate (argon), surface temperature of the anode and of the anode holder, and temperature profile in three cross-sections of the arc are column. The last mentioned values were obtained from spectroscopic photographs. From the measured quantities, the following values were calculated: the heat flux into the anode surface, the heat loss of the anode by radiation and conduction, and the heat which was regeneratively transported by the cooling gas back into the arc space. Heat balances for the anode were also obtained. The anode losses (which are approximately 80% of the total arc power for free burning arcs) were reduced by transpiration cooling to 20%. The physical processes of the energy transfer from the arc to the anode are discussed qualitatively.

Eckert, E. R. G.↗

Mineralogical comparison and cooling history of lunar and chondritic vesicular melt breccias

Lunar sample 77135, an impact melt breccia full of vesicles, has been reinvestigated by electron microprobe and X-ray diffraction techniques and compared with a vesicular melt LL chondrite, Yamato 790964, in an attempt to understand their impact heating processes and subsequent cooling history. Notable similarities between the lunar and chondritic melt breccias include: abundant vesicles, similar pyroxene chemical zoning trends, the presence of variable amounts of clastic material, and similar chemical compositions except for K and Na contents of glass and mesostasis. Some constraints on the cooling history are estimated from Mg-Fe diffusion profiles in olivine and pyroxene. The burial depth of lunar sample 77135 during cooling was 0.2-100 m; the depth for the chondrite was probably smaller. Impact melts were probably produced and a layer of regolith retained on the parent body sufficiently thick to allow the olivines to homogenize during slow cooling.

Miyamoto, M.↗

Computing Cooling Flows in Turbines

Algorithm developed for calculating both quantity of compressor bleed flow required to cool turbine and resulting decrease in efficiency due to cooling air injected into gas stream. Program intended for use with axial-flow, air-breathing, jet-propulsion engines with variety of airfoil-cooling configurations. Algorithm results compared extremely well with figures given by major engine manufacturers for given bulk-metal temperatures and cooling configurations. Program written in FORTRAN IV for batch execution.

Gauntner, J.↗

Film cooling on a convex wall: Heat transfer and hydrodynamic measurements for full and partial coverage

Turbine-blade cooling is an important issue for high-efficiency turbine engines, and discrete-hole injection is widely used as a cooling method. In the present study, detailed measurements were made of the heat transfer and hydrodynamics of a film-cooled flow on a convex wall, both for full and partial coverage. Two important parameters were altered: the blowing ratio, m, and the number of rows of injection holes. Three values of m were tested: m = 0.2, 0.4, and 0.6. In the blown region, m = 0.4 results in the lowest Stanton numbers of the three blowing ratios tested. This indicates that the value of m = 0.4 is near optimum on the convex wall from the point of view of cooling effect by injection. In the recovery region, Stanton numbers gradually approach the no injection values. Although the heat-transfer behavior during recovery from injection looks relatively complicated, the behavior of Stanton number can be explained in terms of two mechanisms: recovery from the thermal effect of injection and recovery from the turbulence augmentation. This interpretation of the data is supported by the hydrodynamic and temperture-profile measurements. For partial blowing cases, the data follow the full-coverage values inside the blown region. In the unblown region, both in the curved and in the flat plate, the effect of the number of blown rows is clearly seen. Hydrodynamic boundary-layer profiles were measured with the aid of a triple hot-water probe. Three mean-velocity components and six turbulence quantities were simultaneously measured, and inside the blown region strong three-dimensionality was observed.

Furuhama, K.↗

A small helium liquifier which provides continuous cooling based on cycled isentropic expansion

This simple cryocooler provides a small reservoir of liquid helium at a stable temperature of 4.2K. It uses a novel adaptation of the Simon expansion cryocooler to provide continuous cooling. Operation is in a four stage cycle: (1) A closed vessel of helium under high pressure is cooled to 12K using a conventional Gifford-McMahon closed-cycle cryocooler. (2) The pressure is released adiabatically providing cooling to 4.2K. (3) Liquid helium is collected in a second, well insulated, vessel. (4) The first vessel is repressurized. The cycle time is 15-30 minutes. In this manner, a pool of liquid helium is continuously maintained in the second vessel, with a temperature stability of 0.03 degrees. The continuous cooling power available is 3mW. This design provides simplicity and reliability through the absence of any orifices or moving parts at cryogenic temperatures except for the conventional Gifford-McMahon cryocooler.

Winter, C.↗

Radio continuum emission from winds, chromospheres, and coronae of cool giants and supergiants

The results of a sensitive VLA radio survey of the single cool-wind giants and super giants stars, having spectral types in the range (G0-M5), are presented. The survey was carried out at 6 cm using the NRAO VLA. The results of the observations are discussed in the context of the various mechanisms which might be producing radio emission in the cool stars. One coronal giant was detected as well as six cool-wind giants in the range 2-6 cm at levels of 0.1-2 mJy. The six-cm emission of the coronal giant alpha Aurigae is shown to be optically thin having free-free emission from the corona of energy 10 to the 7th K. The 2-cm emission from alpha Aur also contains contribution of about 65 percent from the stellar disk of one or both stars. The radio emission from all other sources is explained as optically thick emission from stellar winds. The inferred ionized mass-los rates for the cool wind stars was about 10 to the 10th solar mass per year for MK III-type stars and 10 to the -9th solar mass per year for MK II type stars.

Drake, S. A.↗

Cooling rate calculations for silicate glasses

The effects of thermal properties, sample size, and quench medium on cooling rates achieved during quenching are evaluated for a variety of samples with different thermal properties. It is found that, depending on the composition and the property being observed, quench rate may or may not be fast enough to preserve a high-temperature property. If the cooling rate dependence of a property in a given system is unknown, then the cooling rate must be specified so that others may duplicate specific conditions. The effect of cooling rate can be experimentally tested by manipulation of sample size and quench medium. These results should add to understanding of glass-forming phenomena on the moon.

Birnie, D. P., III↗

The detection of distant cooling flows and the formation of dark matter

Cooling flows involving substantial mass inflow rates appear to be common in many nearby rich and poor clusters and in isolated galaxies. The extensive optical and ultraviolet filaments produced by the thermal instability of large flows are detectable out to redshifts greater than 1. It is proposed that this may explain the extended optical line emission reported in, and around, many distant radio galaxies, narrow-line quasars, and even nearby normal and active galaxies. An important diagnostic to distinguish cooling flows from other possible origins of emission line filaments is the presence of extensive regions at high thermal pressure. Other evidence for distant cooling flows and the resultant star formation is further discussed, together with the implications of cooling flow initial-mass functions for galaxy formation and the nature of 'dark' matter.

Fabian, A. C.↗

Vibrational and rotational cooling of electrons by water vapor

The cooling of electrons by vibrational and rotational excitation of water molecules plays an important role in the thermal balance of electrons in cometary ionospheres. The energy-loss function for rotational excitation and deexcitation of H2O by electron impact is calculated theoretically. The rotational cooling rate is calculated using this loss function for a wide range of electron and neutral temperatures. The vibrational cooling rate is calculated using measured values of electron-impact vibrational excitation cross sections. Analytical formulas are provided for some of the cooling rates. The interaction of ions with H2O molecules is also discussed, and a formula is suggested for the momentum-transfer collision frequency.

Cravens, T. E.↗

Radiative heating and cooling rates in the middle atmosphere

One of the limitations to the accurate calculation of radiative heating and cooling rates in the stratosphere and mesosphere has been the lack of accurate data on the atmospheric temperature and composition. Data from the LIMS experiment on Nimbus-7 has been extended to the South Pole with the aid of other observations. The data have been used as input to codes developed by Ramanathan and Dickinson to calculate the individual components and the net radiative heating rates from 100-0.1 mb. Solar heating due to ozone, nitrogen dioxide, carbon dioxide, water vapor and oxygen is shown to be nearly balanced by cooling in the thermal infrared spectral region due to carbon dioxide, ozone and water vapor. In the lower stratosphere, infrared transfer by ozone leads to heating that is sensitive to the distribution of tropospheric ozone, clouds and water vapor. The heating and cooling rates are adjusted slightly in order to satisfy the global mass balance. The results are in qualitative agreement with earlier calculations, but show additional detail. There is as strong temporal and vertical variation of cooling in the tropics. Radiative relaxation times are as short as 7 days or less at the stratopause.

Gille, John C.↗

Transient radiative cooling of a droplet-filled layer

A proposed lightweight radiator system for waste heat dissipation in space would eject streams of coolant in the form of small, hot liquid droplets. The droplets would lose radiative energy by direct exposure to the very low-temperature environment of space, and would then be collected for reuse. The cooling behavior of a layer composed of many small droplets was studied by numerical solution of the radiative integral equations. Since there is mutual interference for radiative energy dissipation, an array droplet will cool more slowly than if each drop is exposed individually. Since liquid metal droplets may be used, the study includes results for conditions with high scattering. For optically thin regions, especially with high scattering, the temperature distribution is sufficiently uniform that the cooling can be computed using the approximation of a constant layer emittance. For optically thick layers starting at uniform temperature, the temperature distributions become nonuniform with time. It was found that the cooling process goes through a starting transient; a constant emittance condition is then achieved where the emittance is lower than that for a layer at uniform temperature.

Siegel, R.↗

Star formation in X-ray cluster cooling flows

The basic equations for X-ray cluster cooling flows, including the effects of star formation, are derived. It is confirmed that cooling flows are thermally unstable, and it is found that the fastest-growing linear perturbations in the flow are radial, comoving, and isobaric. A local approximation for the star formation rate is developed which allows analytic solutions to be found for both isobaric and gravity-dominated cooling flows. These solutions are used to show how star formation reduces the gas density, thereby lowering the cooling rate, which raises the gas temperature relative to the non-star-forming case. The analytic solutions are also used to estimate the spatial distribution of newly formed stars. It is found that star formation must proceed at a nearly maximal rate if isothermal mass profiles are to result.

White, Raymond E., III↗

The growth of thermal instabilities in cooling flows

Numerical hydrodynamic simulations are used to determine the evolution of the condensation modes for thermal instabilities in 10 to the 6th to 10 to the 8th K gas. These simulations properly take into account the effects of nonequilibrium cooling below 10 to the 6th K. It is found that only perturbations greater than about 3 kpc develop shocks in the hot environment of cooling flows. These large perturbations evolve through three distinct phases: (1) the formation of a cold core, (2) a supersonic accretion phase onto the cold core which lasts for 10 to the 5th to 10 to the 6th yr with peak shock velocities about 120 km/s, and (3) a subsonic accretion phase. The X-ray emissivity and the optical-ultraviolet line emission associated with thermal instabilities are calculated. These calculations demonstrate that the optical emission from cooling flows probably does not arise from shocked condensations. The calculated optical emission lines are of a higher ionization level and a lower luminosity than the observations. Ultraviolet lines produced in the shocks may be detectable. The core must cool significantly after the shock has dissipated before star formation can commence.

David, Laurence P.↗

An adiabatic demagnetization cooled bolometer system

An adiabatic demagnetization refrigeration (ADR) system suitable for cooling bolometers for use at infrared and submillimeter wavelengths is constructed. Because it does not rely on a gravitational field for operation, this refrigeration method has been proposed to cool bolometers intended for NASA's Space Infrared Telescope Facility. To explore the use of ADR in this manner, a portable instrument that has been used successfully for ground-based astronomical observations was constructed. By employing chromic potassium sulfate as a paramagnetic cooling material, bolometers were cooled to temperatures of 0.1 K with a cryogenic hold time of greater than nine hours.

Lesyna, L.↗