Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Consequence Analysis of Residual Water in a Storage Canister (Preliminary Report)

The objective of this work is to examine the consequences of a residual water on change in condition of cladding and SNF during dry storage. Small amounts of residual water may remain in SNF dry storage canisters after the fuel assemblies are transferred to the canister in the spent fuel pool (SFP), the canister is removed from the SFP and drained or pumped, vacuum dried in several pressure reducing steps, and backfilled with helium. This residual water from incomplete drying could degrade fuel rod cladding, oxidize exposed fuel pellets, and cause cladding failure resulting in SNF fines’ release in canister cavity. If residual water content is high enough, it could corrode internal components inside the canister, e.g., fuel basket, and neutron absorber plates, but CNWRA work indicated that corrosion of the internal component is expected to be negligible even with 55 moles of residual water. Considering this, focus of this work to determine partitioning of residual water towards fuel and cladding oxidation. Residual water will decompose by radiolysis and create reactive oxygen species, which, at sufficient high temperatures will oxidize cladding, and UO 2 exposed by clad breaches. If a significant fraction of UO 2 in a fuel rod is oxidized to U 3 O 8 , swelling of the fuel pellets will rupture the cladding and release fuel particles, contaminating the inside of the canister and complicating retrieval of fuel assemblies, transport and ultimate disposal. The report describes an evaluation of the potential cladding and exposed SNF pellets due to residual water. An integrated quantitative approach was used to estimate the effects. The approach consisted of (i) the evolution of environmental conditions, i.e., temperature and radiation field, in the cask, (ii) the physicochemical processes that affect degradation of the materials within the cask, and (iii) the potential damage states that may result from these conditions and processes. The assessment considers the following set of cask environmental conditions: (i) the quantity of residual water after drying, (ii) internal temperature fields and their intensity decrease over time, and (iii) the strength of the internal radiation field. The quantity of residual water will affect the mass of cladding, SNF, and other components that are degraded by oxidation. Temperature controls the rate of the oxidation reactions, the phase composition of water, and, to a lesser extent, the rate at which water vapor is radiolyzed. The strength of the radiation field controls the radiolysis rate of residual water. These processes, i.e., time evolution of temperature fields and their effects on radiolysis of residual water, fuel and cladding oxidations, were modeled using the integrated approach.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Opportunities for Using the Industrial Assessment Center Database for Industrial Water Use Analysis

The manufacturing sector accounted for approximately 5–6% of total U.S. water use in 2015. Of that amount, 75–80% is self supplied withdrawal from surface-water and groundwater sources and the remainder is from public water supplies. Although manufacturing facilities commonly locate in water-scarce areas, water scarcity still poses a great risk to the manufacturing sector. Reliable water is necessary for any facility that relies on it for process and comfort cooling, cleaning, employee use, and steam generation. One of these barriers to water efficiency is the lack of reliable data on overall U.S. industrial water use—how it is used and the quantities required for each sector. If a facility cannot be easily compared with a facility of similar size and sector, knowing if it is effectively using water conservation best practices is difficult. One potential source of industrial water use data is the U.S. Department of Energy (DOE)–sponsored Industrial Assessment Centers (IACs). IACs are university-based organizations that provide free audits to small- and medium-sized manufacturing facilities to identify productivity improvement and waste and energy reduction opportunities. The IACs also maintain a database of all the audits conducted, which currently holds more than 19,267 assessments and 145,000 recommendations (as of July 24, 2020). This database also contains energy utility (electricity, natural gas, and other fuels) and water utility data, making it a potential data source for industrial water use. This report attempts to create regression models to predict a small- or medium-sized industrial facility’s annual water use or cost based on its industrial subsector and several possible relevant variables. Using data collected by IAC assessments, models for several industrial subsectors were generated via stepwise regression techniques to determine which variables (annual sales, number of employees, facility/plant area, annual production hours, and a water stress metric) are relevant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Microgrids: A Primer for Facility Managers

A water microgrid is similar in concept to an energy microgrid, which the U.S. Department of Energy defines as “a local energy grid with control capability, which means it can disconnect from the traditional grid and operate autonomously.” Similarly, a water microgrid is a local water system that supplies, treats, and distributes water, with the primary objective to meet mission critical water demands during a disruption of the primary supply. A water microgrid has the capability to operate independently of an existing primary water system and includes a layer of sensing capability that provides the necessary monitoring and controls to operate the water microgrid. A water microgrid may offer a viable solution for a site to address resilience gaps identified through the resilience planning process. For example, a site may not have adequate and redundant water supply to meet mission critical demands with vulnerabilities in the operating systems. A water microgrid provides the ability to island the water system from the primary water supply to satisfy water demand requirements throughout an outage or disruption.

42 ENGINEERING↗

Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition

This report builds on the 2016 Water and Wastewater Annual Price Escalation Rates for Selected Cities across the United States report prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP). The 2017 report examined annual water and wastewater price escalation rate trends across the U.S. Annual water and wastewater price escalation rates are an important factor when conducting life-cycle cost analyses (LCCA) of water efficiency measures, which is required for Federal agencies. Following the framework of the 2017 report, PNNL used the American Water Works Association (AWWA) water and wastewater rate surveys to gather historical rate data for water and wastewater utilities in the US, which were used to calculate a sample set of water and wastewater annual price escalation rates (Figure E.1). An annual price escalation rate was calculated for 113 water utilities and 76 wastewater utilities that reported at least two AWWA surveys across the past 13 years (i.e., 2008 to 2021) and at least a five-year range between those two surveys. Statistical trends in the annual price escalation rates are also provided by the seven regions identified in Figure E.1. In the 2017 report, the average annual price escalation for the surveyed sample of water and wastewater rates were 3.0% and 3.2%, respectively. This report also calculated aggregate average annual price escalation rates for the surveyed sample of water and wastewater utilities to be 3.1% and 2.7%, respectively. These escalation rates were based on 87 water utilities and 46 wastewater utilities that reported data in at least two AWWA surveys with at least a five-year range between those two surveys and reported at least one AWWA survey in 2019 or 2021. Among water utilities, the highest average annual price escalation rate was 8.8%, and the highest average annual water de-escalation rate was -2.0%. And for wastewater utilities, the highest average annual wastewater price escalation rate was 10.2%, and the highest average annual wastewater de-escalation rate was -2.3%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sustainable Water Management: Understanding the Socioeconomic and Cultural Dimensions

With the pressing challenges of water scarcity and pollution, achieving sustainable water management is imperative for promoting long-term development. Therefore, this paper aims to examine the socio-economic and cultural factors that shape the sustainability of water management strategies in Brazil and Portugal. This study highlights various factors that influence water management, including robust legal frameworks, socio-economic disparities, cultural practices, agricultural water usage, knowledge sharing, public participation, climate change resilience, water scarcity risks, industrial water consumption, and urbanization. By conducting a SWOT analysis of water management strategies, this research synthesizes information through an extensive literature review, encompassing the legal frameworks, policies, and implemented strategies in both countries. Additionally, it investigates comparative studies among Brazil, Portugal, and other European nations to facilitate the exchange of knowledge and experiences in water management practices. The findings of this study offer valuable insights into the strengths, weaknesses, opportunities, and threats associated with water management strategies in Brazil and Portugal, thereby guiding the development of tailored policies and strategies that foster sustainability in water resource management. Additionally, the research highlights the role of digital transformation in optimizing water management practices. By integrating socio-economic, cultural, and digital factors, this study contributes to effective and sustainable water management in Brazil and Portugal, ensuring responsible utilization and preservation of water resources.

Santos, Eleonora↗

Colloquium on Water in Planetary Regoliths, Hanover, N.H., October 5-7, 1976, Proceedings

The papers abstracted in this volume deal with the occurrence, detection, and measurement of water on planetary bodies in the solar system; relevant aspects of the terrestrial water balance; the most probable status of water on other planetary bodies; and the methods of water detection and measurement available for consideration in designing planetary exploration missions. Topics include the water inventory for earth, high-energy protons as an early source of regolith water, the evolution of water on Mars, the chemical evolution of the Martian atmosphere by surface weathering, some geochemical aspects of excess volatiles on Mars, fluvial erosion on Mars, water in the outer solar system, and the stability of water on the Galilean satellites. Other papers discuss gamma-ray attenuation methods for determining the water content of soil, Viking biology-experiment results relevant to water on Mars, IR detection of water ice on satellite surfaces during the Mariner Jupiter/Saturn mission, electrical sounding of the lunar regolith, the detection of water on the moon and Mars by orbital gamma-ray spectroscopy, and the Viking Martian soil-water analyzer.

Bowen, S.L.↗

A Study of Flame Propagation on Water-Mist Laden Gas Mixtures in Microgravity

The use of water mists (very fine water sprays) for fire suppression is currently receiving increased attention as a replacement technology for halogen-based chemical agents-such as Halon 1301 (CF3Br)--the manufacturing of which has been banned by the Montreal Protocol due to their high ozone depletion potential. Water mist technology has been found effective for a wide range of applications such as Class B pool fires, shipboard machinery, aircraft cabins, computers, and electronic equipment. There are five distinct mechanisms by which water droplets may interact with a flame. First, the high enthalpy of vaporization of water (2450 kJ/kg) leads to heat removal from the flame front as the liquid droplets turn to steam. Second, as water vaporizes its volume increases approximately three orders of magnitude, which leads to the dilution of the oxygen and vaporized fuel required to maintain the flame. The third effect is the recombination of H-atoms and other radicals on the droplet surface. A fourth effect of water mists in fires is the retardation of surface propagation rates due to the wetting of walls and surfaces. The last potential impact of fine water mists affects the radiative propagation of the fire by forming an optically thick barrier to infrared radiation which prevents ignition of the unburned regions. Unfortunately, little fundamental information exists on the interaction of a flame with a water mist. To date, there is no widely accepted interpretation of the critical concentration of droplets required to suppress a flame or of the fundamental mechanisms involved in flame extinguishment by water mists. One of the main obstacles to obtaining such understanding is the difficulty of providing a simple, well-defined experimental setup for the flame front/water mist interaction. Some of the difficulty stems from the problem of generating, distributing and maintaining a homogeneous concentration of droplets throughout a chamber while gravity depletes the concentration and alters the droplet size by coalescence and agglomeration mechanisms. Experiments conducted in the absence of gravity provide an ideal environment to study the interaction of water mists and flames by eliminating these distorting effects. In addition, microgravity eliminates the complex flow patterns induced between the flame front and the water droplets. The long duration and quality of microgravity in space flights provide the required conditions to perform the setup and monitoring of flame suppression experiments. Consequently, a series of experiments have been identified to be performed on the Combustion Module (CM-2) in the Space Shuttle. These consist of measuring the extinguishing capability of a water mist on a premixed flame propagating along a tube. These experiments should provide the necessary data to obtain further understanding of the water mist suppression phenomena that can be later used to design and manufacture appropriate fire suppression systems. In preparation for the orbital flights, experiments have been conducted on low-gravity ground facilities to obtain the preliminary data necessary to define the scientific objectives and technical issues of the spacecraft experiments.

Abbud-Madrid, A.↗

Water Vapor Tracers as Diagnostics of the Regional Hydrologic Cycle

Numerous studies suggest that local feedback of evaporation on precipitation, or recycling, is a significant source of water for precipitation. Quantitative results on the exact amount of recycling have been difficult to obtain in view of the inherent limitations of diagnostic recycling calculations. The current study describes a calculation of the amount of local and remote sources of water for precipitation, based on the implementation of passive constituent tracers of water vapor (termed water vapor tracers, WVT) in a general circulation model. In this case, the major limitation on the accuracy of the recycling estimates is the veracity of the numerically simulated hydrological cycle, though we note that this approach can also be implemented within the context of a data assimilation system. In this approach, each WVT is associated with an evaporative source region, and tracks the water until it precipitates from the atmosphere. By assuming that the regional water is well mixed with water from other sources, the physical processes that act on the WVT are determined in proportion to those that act on the model's prognostic water vapor. In this way, the local and remote sources of water for precipitation can be computed within the model simulation, and can be validated against the model's prognostic water vapor. Furthermore, estimates of precipitation recycling can be compared with bulk diagnostic approaches. As a demonstration of the method, the regional hydrologic cycles for North America and India are evaluated for six summers (June, July and August) of model simulation. More than 50% of the precipitation in the Midwestern United States came from continental regional tracers, and the local source was the largest of the regional tracers (14%). The Gulf of Mexico and Atlantic 2 regions contributed 18% of the water for Midwestern precipitation, but further analysis suggests that the greater region of the Tropical Atlantic Ocean may also contribute significantly. In general, most North American land regions showed a positive correlation between evaporation and recycling ratio (except the Southeast United States) and negative correlations of recycling ratio with precipitation and moisture transport (except the Southwestern United States). The Midwestern local source is positively correlated with local evaporation, but it is not correlated with water vapor transport. This is contrary to bulk diagnostic estimates of precipitation recycling. In India, the local source of precipitation is a small percentage of the precipitation owing to the dominance of the atmospheric transport of oceanic water. The southern Indian Ocean provides a key source of water for both the Indian continent and the Sahelian region.

Bosilovich, Michael G.↗

Carbon Nanotubes in Water: MD Simulations of Internal and External Flow, Self Organization

We have developed computational tools, based on particle codes, for molecular dynamics (MD) simulation of carbon nanotubes (CNT) in aqueous environments. The interaction of CNTs with water is envisioned as a prototype for the design of engineering nano-devices, such as artificial sterocillia and molecular biosensors. Large scale simulations involving thousands of water molecules are possible due to our efficient parallel MD code that takes long range electrostatic interactions into account. Since CNTs can be considered as rolled up sheets of graphite, we expect the CNT-water interaction to be similar to the interaction of graphite with water. However, there are fundamental differences between considering graphite and CNTs, since the curvature of CNTs affects their chemical activity and also since capillary effects play an important role for both dynamic and static behaviour of materials inside CNTs. In recent studies Gordillo and Marti described the hydrogen bond structure as well as time dependent properties of water confined in CNTs. We are presenting results from the development of force fields describing the interaction of CNTs and water based on ab-initio quantum mechanical calculations. Furthermore, our results include both water flows external to CNTs and the behaviour of water nanodroplets inside heated CNTs. In the first case (external flows) the hydrophobic behaviour of CNTs is quantified and we analyze structural properties of water in the vicinity of CNTs with diagnostics such as hydrogen bond distribution, water dipole orientation and radial distribution functions. The presence of water leads to attractive forces between CNTs as a result of their hydrophobicity. Through extensive simulations we quantify these attractive forces in terms of the number and separation of the CNT. Results of our simulations involving arrays of CNTs indicate that these exhibit a hydrophobic behaviour that leads to self-organising structures capable of trapping water clusters. In the second case (internal flows) we study the behaviour of water droplets confined inside CNTs. Constant temperature simulations allow us to capture structural properties such as the contact angles and density profiles of the equilibrated drops. By heating and subsequently cooling of the CNT, we are able to measure the evaporation and the condensation rate of the entrapped water.

Jaffe, Richard L.↗

Body water handling in response to hypertonic-saline induced diuresis in fasting northern elephant seal pups (Mirounga angustirostris)

During natural fasting conditions in postweaned northern elephant seal (NES) (Mirounga angustirostris) pups, urinary water loss is minimized and percent total body water (TBW) is maintained constant. However, following infusion of hypertonic saline, glomerular filtration rate (GFR) and urine output increased in fasting pups. Therefore, we quantified the magnitude of the hypernatremia-induced diuresis relative to the animal's total body water (TBW) pool and the percentage of filtered water reabsorbed. Following a 24 h control period, naturally fasting NES pups (n=7) were infused (4 ml min(-1)) with hypertonic saline (16.7%) at a dose of 3 mmol NaCl kg(-1) body mass. Total body water was estimated prior to infusion by tritium dilution, GFR was estimated by standard creatinine clearance, and urine output (V) was measured for 24 h during the control and post infusion periods. Percentage of filtered water reabsorbed was calculated as (1-(V/GFR))x100. Twenty-four hours following the infusion, GFR (control: 69+/-12 ml min(-1) and post-infusion: 118+/-19 ml min(-1); mean+/-S.E.) increased 77+/-28% above control and the percentage of filtered water reabsorbed was decreased 0.4+/-0.1%. The increase in urine output (control: 218+/-47 ml d(-1) and post-infusion: 883+/-92 ml d(-1)) accounted for 1.7+/-0.2% of the pups' TBW. The hypernatremia-induced diuresis was accompanied by the loss of body water indicating the lack of water retention. Although the 77% increase in GFR was only associated with a 0.4% decrease in the percentage of filtered water reabsorbed, this decrease was significant enough to result in a 4-fold increase in urine output. Despite the observed diuresis, fasting NES pups appear to possess an efficient water recycling mechanism requiring only a small percentage of body water to excrete an excess salt load. This water recycling mechanism may allow pups to avoid negative perturbations in body water as they initiate feeding in a marine environment following the fast.

Non-NASA Center↗

Water in the Oceanic Lithosphere: Salt Lake Crater Xenoliths, Oahu, Hawaii

Water can be present in nominally anhydrous minerals of peridotites in the form of hydrogen bonded to structural oxygen. Such water in the oceanic upper mantle could have a significant effect on its physical and chemical properties. However, the water content of the MORB source has been inferred indirectly from the compositions of basalts. Direct determinations on abyssal peridotites are scarce because they have been heavily hydrothermally altered. Here we present the first water analyses of minerals from spinel peridotite xenoliths of Salt Lake Crater, Oahu, Hawaii, which are exceptionally fresh. These peridotites are thought to represent fragments of the Pacific oceanic lithosphere that was refertilized by alkalic Hawaiian melts. A few have unradiogenic Os and radiogenic Hf isotopes and may be fragments of an ancient (~2 Ga) depleted and recycled lithosphere. Water contents in olivine (Ol), orthopyroxene (Opx), and clinopyroxene (Cpx) were determined by FTIR spectrometry. Preliminary H_{2}O contents show ranges of 8-10 ppm for Ol, 151-277 ppm for Opx, and 337-603 ppm for Cpx. Reconstructed bulk rock H_{2}O contents range from 88-131 ppm overlapping estimates for the MORB source. Water contents between Ol minerals of the same xenolith are heterogeneous and individual OH infrared bands vary within a mineral with lower 3230 cm^{-1} and higher 3650-3400 cm^{-1} band heights from core to edge. This observation suggests disturbance of the hydrogen in Ol likely occurring during xenolith entrainment to the surface. Pyroxene water contents are higher than most water contents in pyroxenes from continental peridotite xenoliths and higher than those of abyssal peridotites. Cpx water contents decrease with increasing degree of depletion (e.g. increasing Fo in Ol and Cr# in spinel) consistent with an incompatible behavior of water. However Cpx water contents also show a positive correlation with LREE/HREE ratios and LREE concentrations consistent with refertilization. Opx water contents increase with increasing degree of depletion and decrease with LREE/HREE ratios which is inconsistent with the incompatible behavior of H. Calculated water contents of melts in equilibrium with Cpx or Opx range from 1.4 to 3.8 wt % which is higher than that of all Hawaiian lavas. Calculated melts in equilibrium with Cpx and Opx have variable but mostly high H_{2}O/Ce ratios (194 to 1146) consistent with those of rejuvenated stage lavas from Niihau and the South Arch volcanic field, but unlike the drier shield building stage tholeiites. Whether the high water contents recorded in Salt Lake Crater xenoliths were acquired before and/or during interaction of the oceanic lithosphere with the Hawaiian plume will be discussed.

Peslier, Anne H.↗

FTIR Analysis of Water in Pyroxene and Plagioclase in ALH 84001 and Nakhlites

Determining the volatile budget of the interior of Mars is crucial for our understanding of that planet's formation, geodynamics, cooling history and the origin of its volcanism and atmosphere as well as its potential for life. Surficial water is evident from spacecraft and rover data in polar caps and the atmosphere, in the presence of river channels, and in the detection of water-bearing minerals. Meteorites, however, are our best candidates for estimating the amount of water present at depth, even if all are crustal samples. The last 10 years have seen a blooming of studies measuring water and halogens in Martian meteorites. The bulk of these studies target phosphate, a typically late-stage phase in the igneous Martian meteorites that potentially would concentrate incompatible element hydrogen (H quantified traditionally as "water", i.e., H2O concentrations in weight) near the end of the crystallization sequence. However, determining the amount of water, F, and Cl in the magma from which a phosphate crystallized from is not straightforward and in most instances not possible. On the other hand, phosphates have turned out to be very useful in identifying hydrothermal processes that could have added water while or after the magma flowed and crystallized. Another caveat of analyzing Martian meteorite phases for water is that shocked phases such as maskelynite and impact melts appear to have incorporated water from the Martian atmosphere, as evidenced by high H isotope ((delta)D) signatures, and therefore their water concentrations cannot be interpreted in terms of deep planetary processes. The best candidates for estimating the water content of the Martian interior have been melt inclusions (glass or amphibole-bearing) which the enclosing mineral (usually olivine) would have prevented from exchanging volatiles with the surroundings after crystallization. Even some of these, however, have high (delta)D, meaning they were affected by H exchange via impact events or with crustal reservoirs or hydrothermal fluids. Here, nominally anhydrous minerals (pyroxene, olivine, plagioclase, or maskelynite) in orthopyroxenite ALH 84001 and selected nakhlites are analyzed for water and major elements, in order to determine 1) whether they contain any water; 2) if they do, what controls its distribution (crystallization, degassing, hydrothermal or impact processes); and 3) if any of these measurements can be used to infer the water contents of the parent magma and their mantle sources. A shock-reverberation experiment was also performed on terrestrial orthopyroxenes (opx) to simulate the heavily shocked conditions of ALH 84001 (> 31 GPa [17]).

Peslier, A. H.↗

Developing Mass Spectrometry for Water Quantitation and Volatiles Analysis from In-Situ Regolith

With a revived focus to create a sustainable hu-man presence on the moon, and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential [1]. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable in-dependent operation of missions while reducing the dependence on the complex supply chain created between the Earth, the moon and Mars. One of the most critical resources that has been identified for ISRU on the lunar surface is water [2]. Water is a versatile resource that can be used in various space operations, such as ra-diation shielding and conversion to oxygen (O2) for propellant [3,4]. One of the most water rich resources is thought to be within the regolith lo-cated in the permanently shadowed regions (PSR) of the Moon; several upcoming missions, such as PRIME-1 and VIPER, are already sched-uled to confirm this hypothesis [5,6]. However, there are currently no missions planned to quanti-fy the abudance of water at these regions. The quantity of water contained in the ice will inform and help the development of future ISRU plants and operation. Water and other volatile gases can be detect-ed upon controlled heating of icy lunar regolith for an accurate quantification of water. This method is similar to thermogravimetric analysis, which was used to analyze Apollo lunar regolith sam-ples. However, losses via sublimation/evaporation or contamination may have occurred with the samples due to the transit and exposure to the terrestrial environment. Furthermore, water would not be expected for these samples since they were not collected from a PSR. Thus, for more accurate results, icy lunar regolith should be ana-lyzed in situ to provide the most representative composition of both water and other volatile gas-es. The Light Water Analysis and Volatile Extract (LightWAVE) project aims to address this knowledge gap. A system has been developed to collect, heat and analyze evolved gases from lu-nar regolith on the lunar surface. The gases will be analyzed by a modified commercial off the shelf (COTS) residual gas analyzer (RGA) quad-rupole mass spectrometer. Evolved gases from heated regolith samples can be identified by the observed mass-to-charge (m/z) ratios, and the peak intensities correlate to the abundances of the observed gases for quantitation. Therefore, our group is developing a calibration methodology utilizing a COTS RGA to quantitate water from in-situ regolith samples on the lunar surface. The partial pressure of water and ideal gas law will be used to quantify the total water evolved from a regolith sample. Here we present our methodol-ogy for the design and calibration for water quan-titation using a COTS RGA.

Nilab Azim↗

Energy Savings from Industrial Water Reductions

Although it is widely recognized that reducing freshwater consumption is of critical importance, generating interest in industrial water reduction programs can be hindered for a variety of reasons. These include the low cost of water, greater focus on water use in other sectors such as the agriculture and residential sectors, high levels of unbilled and/or unregulated self-supplied water use in industry, and lack of water metering and tracking capabilities at industrial facilities. However, there are many additional components to the resource savings associated with reducing site water use beyond the water savings alone, such as reductions in energy consumption, greenhouse gas emissions, treatment chemicals, and impact on the local watershed. Understanding and quantifying these additional resource savings can expand the community of businesses, NGOs, government agencies, and researchers with a vested interest in water reduction. This paper will develop a methodology for evaluating the embedded energy consumption associated with water use at an industrial facility. The methodology developed will use available data and references to evaluate the energy consumption associated with water supply and wastewater treatment outside of a facility’s fence line for various water sources. It will also include a framework for evaluating the energy consumption associated with water use within a facility’s fence line. The methodology will develop a more complete picture of the total resource savings associated with water reduction efforts and allow industrial water reduction programs to assess the energy and CO2 savings associated with their efforts.

Rao, Prakash↗

Effect of Initial Water Saturation on The Performance of Fracturing Fluids With and Without Polyallylamine under Simulated EGS Conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO2-reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO2, can be used as a less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO2 fracturing fluids outperformed other fluids such as water, CO2, and CO2/water in generating large fractures with less fluid consumed. The objective of this work is to study the effect of initial water saturation of rock on the performance of StimuFrac fluid in ½ foot cubic rock samples and under representative EGS pressure/temperature conditions using cyclic and constant flow rate injection strategies. The fracturing results are compared with results using different fracturing fluids in terms of controlling fracture propagation rates, fracture hydraulic conductivity, breakdown pressures and volumes of fluids required. Methods/Procedures/Process: In all tests, water was initially injected into the rock to increase the water saturation before the fracturing processes to simulate actual geothermal reservoir conditions. For the cyclic injection, one complete cycle consisted of (1) a PAA slug (or water slug) injection followed by (2) CO2 injection to initiate the fracture. In the second step of the first cycle, the pressure of CO2 is increased until a maximum pressure is reached (fracture is initiated at this moment), and then the injection of CO2 is allowed for another 30 seconds to propagate the fracture. Then, the two-step cycle of PAA followed by CO2 injection (up to 2-4 mL/min) was continued. For the constant flow rate injection strategies, the initial water saturation was increased by injecting water at 1000 psi and 200°C for three days. After that, an initial slug of water, CO2, or PAA was injected and then fracturing was initiated and propagated by injecting CO2 at a constant flow rate. Applications/Significance/Novelty: The results of this study suggest that water saturation, especially near the wellbore region, will significantly affect the fracturing fluid transmission into the rock porous media by changing the relative permeability of CO2 or water, thus affecting the fracture initiation and propagation. In this study, fracturing with cyclic injection or constant flow rate injection methods were performed using three different kinds of fluids systems. These fluids are water, CO2, or CO2 with PAA. Splitting the rock samples in half after fracturing reveals that the fracture propagation is significantly limited under these high water saturated conditions compared to dry initial conditions: The fractures propagate less than 1/3 length of the distance from the wellbore to rock surface, and in some cases no fracture is generated. This may be caused by the fact that leak-off is dominating the fracturing process and the injected fluid flow rate is not high enough to overcome the leak-off even under high flow rate injection conditions. Additionally, CO2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate pressure gradients away from the near-wellbore region.

Jian, Guoqing↗

Subsecond Morphological Changes in Nafion during Water Uptake Detected by Small-Angle X-ray Scattering

The ability of the Nafion membrane to absorb water rapidly and create a network of hydrated interconnected water domains provides this material with an unmatched ability to conduct ions through a chemically and mechanically robust membrane. The morphology and composition of these hydrated membranes significantly affects their transport properties and performance. This research demonstrates that differences in interfacial interactions between the membranes exposed to vapor or liquid water can cause significant changes in kinetics of water uptake. In situ small-angle X-ray scattering (SAXS) experiments captured the rapid swelling of the membrane in liquid water with a nanostructure rearrangement on the order of seconds. For membranes in contact with water vapor, morphological changes are four orders-of-magnitude slower than in liquid water, suggesting that interfacial resistance limits the penetration of water into the membrane. Furthermore, upon water absorption from liquid water, a structural rearrangement from a distribution of spherical and cylindrical domains to exclusively cylindrical-like domains is suggested. These differences in water-uptake kinetics and morphology provide a new perspective into Schroeder's paradox, which dictates a different water content for vapor- and liquid-equilibrated ionomers at unit activity. Lastly, the findings of this work provide critical insights into the fast kinetics of water absorption of the Nafion membrane, which can aid in the design of energy conversion devices that operate under frequent changes in environmental conditions.

30 DIRECT ENERGY CONVERSION↗

Detecting forest response to droughts with global observations of vegetation water content

Droughts in a warming climate have become more common and more extreme, making understanding forest responses to water stress increasingly pressing. Analysis of water stress in trees has long focused on water potential in xylem and leaves, which influences stomatal closure and water flow through the soil-plant-atmosphere continuum. At the same time, changes of vegetation water content (VWC) are linked to a range of tree responses, including fluxes of water and carbon, mortality, flammability, and more. Unlike water potential, which requires demanding in situ measurements, VWC can be retrieved from remote sensing measurements, particularly at microwave frequencies using radar and radiometry. Here, we highlight key frontiers through which VWC has the potential to significantly increase our understanding of forest responses to water stress. To validate remote sensing observations of VWC at landscape scale and to better relate them to data assimilation model parameters, we introduce an ecosystem-scale analogue of the pressure-volume curve, the non-linear relationship between 44 average leaf or branch water potential and water content commonly used in plant hydraulics. The 45 sources of variability in these ecosystem-scale pressure-volume curves and their relationship to 46 forest response to water stress are discussed. We further show to what extent diel, seasonal, and 47 decadal dynamics of VWC reflect variations in different processes relating the tree response to 48 water stress. VWC can also be used for inferring belowground conditions – which are difficult to 49 impossible to observe directly. Lastly, we discuss how a dedicated geostationary spaceborne 50 observational system for VWC, when combined with existing datasets, can capture diel and 51 seasonal water dynamics to advance the science and applications of global forest vulnerability to 52 future droughts.

54 ENVIRONMENTAL SCIENCES↗

Advanced, Energy-Efficient Hybrid Membrane System for Industrial Water Reuse

In the U.S. manufacturing sector, current industrial water use practices are energy-intensive and utilize and discharge high volumes of waters, rendering them not sustainable especially in light of the growing scarcity of suitable water supplies. To help address this problem, the goal of this project was to develop an advanced, cost-effective, hybrid membrane-based water treatment system that can improve the energy efficiency of industrial wastewater treatment while allowing at least 50% water reuse efficiency. This hybrid process would combine emerging Forward Osmosis (FO) and Membrane Distillation (MD) technology components into an integrated FO-MD system that can beneficially utilize low-grade waste heat (i.e., T < 450 °F) in industrial facilities to produce distilled-quality product water for reuse. In this project, laboratory-, bench-, and pilot-scale experiments on the hybrid FO-MD system were conducted for industrial wastewater treatment. It was demonstrated at laboratory, bench, and pilot scales that FO-MD membrane technology can concentrate brine to very high total dissolved solids (TDS) levels (>200,000 ppm) that are at least 2.5 times higher than the TDS level to which RO can achieve. In laboratory testing, currently available FO and MD membranes were tested to select for high-performing membranes with high salt rejection and high water flux. Multiple FO membrane/draw-salt solution combinations that gave high water flux with higher than 98% salt rejection were also identified. Reverse draw-salt fluxes were observed to be much lower for divalent salts than for monovalent salts. MD membranes were identified that had 99.9+% salt rejection and water flux as high as 50-90 L/(m 2 ·h) for flat-sheet membranes and >20 L/(m 2 ·h) for hollow fibers. In bench-scale testing, a single unit of commercially available FO and MD membrane modules were evaluated for continuous, integrated operation. Using the laboratory- and bench-scale test data, numerical modeling was performed on the FO and MD processes to estimate engineering parameters for a larger-scale pilot unit. Based on the experimental studies and modeling results, a pilot-scale, integrated FO-MD prototype unit was designed and built for trailer-mounted operation. This prototype system was fed real industrial wastewater, which could not be further treated by conventional technologies, from an oil production facility and was successfully operated for over 15 weeks without major stoppage. About 90% water recovery was possible, while concentrating the TDS from 12,000 ppm up to 190,500 ppm. The FO-MD prototype rejected most wastewater contaminants while producing water with <300 ppm TDS, even when the feed TDS was higher than 150,000 ppm. No chemical cleaning was necessary during the pilot testing period. Flushing the system with dechlorinated tap water was sufficient to reset the membranes for the next set of test conditions. Pilot performance and membrane autopsy showed that, even though the feed was concentrated more than 10 times, membrane fouling was unnoticeable and no defects were detected on the FO and MD membrane surfaces. This project demonstrated the technical feasibility of the hybrid FO-MD process by taking water already treated to the limit with the highest level of current technologies and further concentrating it 10-fold by using mostly low-cost materials. Because no membranes suitable for full-scale plant applications are available at present, economical feasibility of the hybrid technology is still uncertain, but it is expected that broader industry participation can further reduce FO-MD process costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗