Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Impact of the High Flux Isotope Reactor HEU to LEU Fuel Conversion on Cold Source Nuclear Heat Generation Rates

Under the sponsorship of the US Department of Energy National Nuclear Security Administration, staff members at the Oak Ridge National Laboratory have been conducting studies to determine whether the High Flux Isotope Reactor (HFIR) can be converted from high enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. As part of these ongoing studies, an assessment of the impact that the HEU to LEU fuel conversion has on the nuclear heat generation rates in regions of the HFIR cold source system and its moderator vessel was performed and is documented in this report. Silicon production rates in the cold source aluminum regions and few-group neutron fluxes in the cold source moderator were also estimated. Neutronics calculations were performed with the Monte Carlo N-Particle code to determine the nuclear heat generation rates in regions of the HFIR cold source and its vessel for the HEU core operating at a full reactor power (FP) of 85 MW(t) and the reference LEU core operating at an FP of 100 MW(t). Calculations were performed with beginning-of-cycle (BOC) and end-of-cycle (EOC) conditions to bound typical irradiation conditions. Average specific BOC heat generation rates of 12.76 and 12.92 W/g, respectively, were calculated for the hemispherical region of the cold source liquid hydrogen (LH2) for the HEU and LEU cores, and EOC heat generation rates of 13.25 and 12.86 W/g, respectively, were calculated for the HEU and LEU cores. Thus, the greatest heat generation rates were calculated for the EOC HEU core, and it is concluded that the conversion from HEU to LEU fuel and the resulting increase of FP from 85 MW to 100 MW will not impact the ability of the heat removal equipment to remove the heat deposited in the cold source system. Silicon production rates in the cold source aluminum regions are estimated to be about 12.0% greater at BOC and 2.7% greater at EOC for the LEU core in comparison to the HEU core. Silicon is aluminum s major transmutation product and affects mechanical properties of aluminum including density, neutron irradiation hardening, swelling, and loss of ductility. Because slightly greater quantities of silicon will be produced in the cold source moderator vessel for the LEU core, these effects will be slightly greater for the LEU core than for the HEU core. Three-group (thermal, epithermal, and fast) neutron flux results tallied in the cold source LH2 hemisphere show greater values for the LEU core under both BOC and EOC conditions. The thermal neutron flux in the LH2 hemisphere for the LEU core is about 12.4% greater at BOC and 2.7% greater at EOC than for the HEU core. Therefore, cold neutron scattering will not be adversely affected and the 4 12 neutrons conveyed to the cold neutron guide hall for research applications will be enhanced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulating the Value of Concentrating Solar Power with Thermal Energy Storage in a Production Cost Model

Concentrating solar power (CSP) deployed with thermal energy storage (TES) provides a dispatchable source of renewable energy. The value of CSP with TES, as with other potential generation resources, needs to be established using traditional utility planning tools. Production cost models, which simulate the operation of grid, are often used to estimate the operational value of different generation mixes. CSP with TES has historically had limited analysis in commercial production simulations. This document describes the implementation of CSP with TES in a commercial production cost model. It also describes the simulation of grid operations with CSP in a test system consisting of two balancing areas located primarily in Colorado.

14 SOLAR ENERGY↗

Low-Cost Sulfur Thermal Storage for Solar Industrial Process Heat Applications

Industrial process heat (IPH) is one of the largest energy demands in U.S., representing about 10% of all domestic energy consumption. Fuel costs to generate this industrial process heat are generally a top three cost for industry, a major component in American manufacturing competitiveness. Roughly 60% of US IPH demand (about 6,500 TBtu annually) falls in the medium-temperature range of 100–250 °C. While concentrated solar thermal (CST) technologies can provide a cost-effective source of heat in this temperature range, solar intermittency limits their adoption in industries that operate 24/7. Element 16 Technologies, Inc. developed a low-cost sulfur thermal energy storage (TES) technology to bridge this gap by capturing excess solar heat during the day and dispatching it reliably during non-solar hours. The core innovation is the use of sulfur, an abundant, industrial waste byproduct that costs ten times less than molten salt used in commercial TES systems. The overall goal of the project was to advance the design and development of molten sulfur TES to a manufacturing-relevant prototype stage for solar industrial process heat applications, while establishing and validating a realistic pathway to commercial success. Key tasks included corrosion and mechanical durability testing to identify cost-effective materials, design investigations using physics-based simulation tools, techno-economic evaluations of system lifetime costs, and pilot-scale testing for performance verification. Corrosion testing of steel alloys under cyclic molten sulfur conditions showed that austenitic stainless steels in the 300 series performed particularly well, with no structural degradation of welds or joints. Thermal cyclic testing of pilot sulfur TES units up to 1.5 MWh quantified charge/discharge rates, heat losses, round-trip efficiency and validated the system's capability to operate effectively under intermittent charging conditions. A techno-economic model, informed by sulfur TES performance model validated using pilot test data, showed that hybrid solar+sulfur TES+NG boiler systems are economically competitive with incumbent natural gas boilers for multiple locations in the southwest US. In summary, this project established molten sulfur TES as a technically viable pathway to improve economic competitiveness of American manufacturing by lowering the cost of solar industrial process heat.

14 SOLAR ENERGY↗

Simulations of a PSD Plastic Neutron Collar for Assaying Fresh Fuel

The potential performance of a notional active coincidence collar for assaying uranium fuel based on segmented detectors constructed from the new PSD plastic fast organic scintillator with pulse shape discrimination capability was investigated in simulation. Like the International Atomic Energy Agency's present Uranium Neutron Collar for LEU (UNCL), the PSD plastic collar would also function by stimulating fission in the 235 U content of the fuel with a moderated 241 Am/Li neutron source and detecting instances of induced fission via neutron coincidence counting. In contrast to the moderated detectors of the UNCL, the fast time scale of detection in the scintillator eliminates statistical errors due to accidental coincidences that limit the performance of the UNCL. However, the potential to detect a single neutron multiple times historically has been one of the properties of organic scintillator detectors that has prevented their adoption for international safeguards applications. Consequently, as part of the analysis of simulated data, a method was developed by which true neutron-neutron coincidences can be distinguished from inter-detector scatter that takes advantage of the position and timing resolution of segmented detectors. Then, the performance of the notional simulated coincidence collar was evaluated for assaying a variety of fresh fuels, including some containing burnable poisons and partial defects. In these simulations, particular attention was paid to the analysis of fast mode measurements. In fast mode, a Cd liner is placed inside the collar to shield the fuel from the interrogating source and detector moderators, thereby eliminating the thermal neutron flux that is most sensitive to the presence of burnable poisons that are ubiquitous in modern nuclear fuels. The simulations indicate that the predicted precision of fast mode measurements is similar to what can be achieved by the present UNCL in thermal mode. For example, the statistical accuracy of a ten-minute measurement of fission coincidences collected in fast mode will be approximately 1% for most fuels of interest, yielding a ~1.4% error after subtraction of a five minute measurement of the spontaneous fissions from 238 U in the fuel, a ~2% error in analyzed linear density after accounting for the slope of the calibration curve, and a ~2.9% total error after addition of an assumed systematic error of 2%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hybrid Solar Heat Generation Modelling and Cases: Preprint

Renewable thermal energy systems (RTES) harness renewable energy sources to provide services for space heating and cooling, district heating, domestic hot water, and industrial process heat (IPH). The use of low-pressure steam generated by the combustion of fossil fuels is common today to provide process heat for industrial facilities. Solar IPH (SIPH) technologies could economically replace the steam or heat needs at many industrial sites by providing high-temperature pressurized hot water, a heat transfer fluid (HTF) such as synthetic-oil, or direct steam (Kurup and Turchi, 2015). RTES could be hybridized with technology options or combined with the existing heat supply (e.g. fuels), to give options for targeted IPH application and the reduction of fuel consumption. This work has tested hybrid system modelling approaches. Initial results show when a natural gas (NG) burner that feeds an IPH application of 300°C, has both air and NG streams pre-heated with a solar field/RTES exit temperature of 180°C (via an HTF), a 13% NG offset is possible. NG offsets reach up to 26%, when the RTES exit temperatures are at 300°C for a given annual capacity factor of 24%. This can be even higher with addition of thermal energy storage (TES).

43 PARTICLE ACCELERATORS↗

Summary of: Simulating the Value of Concentrating Solar Power with Thermal Energy Storage in a Production Cost Model (Presentation)

Concentrating solar power (CSP) deployed with thermal energy storage (TES) provides a dispatchable source of renewable energy. The value of CSP with TES, as with other potential generation resources, needs to be established using traditional utility planning tools. Production cost models, which simulate the operation of grid, are often used to estimate the operational value of different generation mixes. CSP with TES has historically had limited analysis in commercial production simulations. This document describes the implementation of CSP with TES in a commercial production cost model. It also describes the simulation of grid operations with CSP in a test system consisting of two balancing areas located primarily in Colorado.

14 SOLAR ENERGY↗

Charge-Control Unit for Testing Lithium-Ion Cells

A charge-control unit was developed as part of a program to validate Li-ion cells packaged together in batteries for aerospace use. The lithium-ion cell charge-control unit will be useful to anyone who performs testing of battery cells for aerospace and non-aerospace uses and to anyone who manufacturers battery test equipment. This technology reduces the quantity of costly power supplies and independent channels that are needed for test programs in which multiple cells are tested. Battery test equipment manufacturers can integrate the technology into their battery test equipment as a method to manage charging of multiple cells in series. The unit manages a complex scheme that is required for charging Li-ion cells electrically connected in series. The unit makes it possible to evaluate cells together as a pack using a single primary test channel, while also making it possible to charge each cell individually. Hence, inherent cell-to-cell variations in a series string of cells can be addressed, and yet the cost of testing is reduced substantially below the cost of testing each cell as a separate entity. The unit consists of electronic circuits and thermal-management devices housed in a common package. It also includes isolated annunciators to signal when the cells are being actively bypassed. These annunciators can be used by external charge managers or can be connected in series to signal that all cells have reached maximum charge. The charge-control circuitry for each cell amounts to regulator circuitry and is powered by that cell, eliminating the need for an external power source or controller. A 110-VAC source of electricity is required to power the thermal-management portion of the unit. A small direct-current source can be used to supply power for an annunciator signal, if desired.

Reid, Concha M.↗

X-RAY EMISSION FROM HESS J1731-347/SNR G353.6-0.7 AND CENTRAL COMPACT SOURCE XMMS J173203-344518

We present new results of the HESS J1731-347/SNR G353.6-0.7 system from XMM-Newton and Suzaku X-ray observations and Delinha CO observations. We discover extended hard X-rays coincident with the bright, extended TeV source HESS J1731-347 and the shell of the radio supernova remnant (SNR). We find that spatially resolved X-ray spectra can generally be characterized by an absorbed power-law model, with a photon index of {approx}2, typical of non-thermal emission. A bright X-ray compact source, XMMS J173203-344518, is also detected near the center of the SNR. We find no evidence of a radio counterpart or an extended X-ray morphology for this source, making it unlikely to be a pulsar wind nebular (PWN). The spectrum of the source can be well fitted by an absorbed blackbody with a temperature of {approx}0.5 keV plus a power-law tail with a photon index of {approx}5, reminiscent of the X-ray emission of a magnetar. CO observations toward the inner part of the High Energy Stereoscopic System (HESS) source reveal a bright cloud component at -20 +- 4 km s{sup -1}, which is likely located at the same distance of {approx}3.2 kpc as the SNR. Based on the probable association between the X-ray and gamma-ray emissions and likely association between the CO cloud and the SNR, we argue that the extended TeV emission originates from the interaction between the SNR shock and the adjacent CO clouds rather than from a PWN.

79 ASTRONOMY AND ASTROPHYSICS↗

Study on release and transport of aerial radioactive materials in reprocessing plants

The release and transport characteristics of radioactive materials at a boiling accident of the high active liquid waste (HALW) in a reprocessing plant have been studied for improving experimental data of source terms of the boiling accident. In the study, a heating test and a thermogravimetry and differential thermal analysis (TG-DTA) test were conducted. In the heating test using a simulated HALW, it was found that ruthenium was mainly released into the air in the form of gas and that non-volatile elements were released into the air in the form of mist. In the TG-DTA test, the rate constants and reaction heat of thermal decomposition of ruthenium nitrosyl nitrate were obtained from TG and DTA curves. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiple X-ray emission components in low-power radio galaxies

We report x-ray observations of the first six sources observed with ROSAT in our study of low-power radio galaxies. Spatial and spectral measurements show that both resolved (thermal) and unresolved X-ray emission in a single source are typical, although the relative strength and size of the resolved component varies between objects. The unresolved X-ray component correlates well with the core radio emission and may be dominated by nonthermal emission associated with an inner radio jet.

Worrall, D. M.↗

Reactive Nitrogen and its Correlation with O3 and CO Over the Pacific in Winter and Early Spring

Measurements of NO, NO(y), O3, and CO were made during NASA's Global Tropospheric Experiment/Pacific Exploratory Mission-West B (GTE/PEM-West B) carried out over the western Pacific in February and March 1994. NO(x) was calculated from NO using a photostationary state model ((NO(x)(sub mc)). Correlations between these species are presented, and some insights into the sources of NO(x) and NO(y) are described. The boundaries between the lower, middle, and upper troposphere have been defined at potential temperatures of 311 K and 328 K, which correspond to the geometric altitudes of about 5 and 9 km at 30degN. Enhancements in the mixing ratios of NO(y) and CO were observed in the lower and middle troposphere. A positive correlation was found between these two species suggesting that the high NO(y) values were due to anthropogenic emissions over the continental surface. On the other hand, O3 increased little with increase in CO. As a result, NO(y)/O3 ratios were higher in air more influenced by pollution. NO(y), values in 55 and 28% of the air masses sampled in the lower and middle troposphere, respectively, were higher than the clean free tropospheric NO(y)-O3 range when O3 values simultaneously observed were used. High (NOx)mc/NOy ratios between 0.15 and 0.3 were found in the boundary layer with relatively low mixing ratios of CO and NOy during the three flights. These air masses were transported from a higher altitude (approximately 5 km) and a higher latitude (approximately 50degN) within a few days. The peroxyacetyl nitrate (PAN)/NO(y) ratios were generally high (approximately 0.4) in these air masses, and the thermal decomposition of PAN was a probable source of NO(x). In the middle troposphere the (NO(x))mc mixing ratio did not generally increase with NO(y) or CO, suggesting that the transport of air masses affected by anthropogenic emissions did not increase the NO(x) level significantly. In the upper troposphere, very minor effects from the continental surface sources were seen in the CO mixing ratio. By contrast, NO(y) values in 33% of the air masses were higher than those expected when stratospheric air intrusion is assumed to be a single source of NO(y) based on NO(y)-O3 correlation analyses. This result suggests significant free tropospheric NO(y) sources, namely exhaust from the aircraft and NO production by lightning activity. In fact, spikes in the (NO(x))(sub m)c mixing ratios were observed near the aircraft corridor south of Tokyo at an altitude of 10 km. These two free tropospheric NO(x) sources were considered to be important in determining the levels of the upper tropospheric NO(x) and NO(y) during PEM-West B.

Koike, M.↗

Bypassing Energy Barriers in Fiber-Polymer Torrefaction

The amount of waste generation has been increasing with a significant amount being landfilled. These non-recyclable wastes contain large number of fiber and plastic wastes which can be treated with thermal processes to turn them into energy sources since they have high calorific values, are abundant and usually tipping fees are paid to handle them. This paper studied the torrefaction of non-recyclable paper (fiber) wastes, mixed plastic wastes (MPW) and their blends at different ratios in the temperature range of 250–400°C through thermogravimetric analysis (TGA). The solid residues after the experiments were analyzed by nuclear magnetic resonance (NMR) spectroscopy. Significant synergy between fiber and MPW were observed at the range 250–300°C, showing both increase in the reaction rate as well as the overall mass loss. At 250°C, the maximum mass loss rate was more than two times higher and the mass loss at the end of the experiments were also much higher compared to the expected results. In addition, synergy was weakened with an increase of temperature, disappearing at 400°C. The existence of such interactions between fiber and plastic wastes indicates that the natural energy barriers during the individual torrefaction in paper waste or plastic waste could be bypassed, and the torrefaction of fiber and plastic blend can be achieved at lower temperatures and/or shorter residence times. The MPW and fiber wastes were also compounded by extrusion (to produce pellets) at 220°C with different blend ratios. The fiber-MPW pellets from extrusion were characterized by IR spectroscopy, rheology, thermal analysis and flexural properties and showed significant chemical changes from the non-extruded blends at the same ratios. From IR characterization, it was found that there was significant increase in hydroxyl (OH) group on account of the carbonyl (C = O) and etheric (C-O-C) groups. The interaction between paper and MPW can be attributed to the plastic polymers acting as a hydrogen donor during the reactive extrusion process. Synergistic effects were also found from mechanical and rheological properties.

09 BIOMASS FUELS↗

Demonstration of thermal limit mean transverse energy from cesium antimonide photocathodes

The mean transverse energy (MTE) of electrons emitted from cathodes is a critical parameter that determines the brightness of electron beams for applications, such as x-ray free electron lasers, particle colliders, and ultrafast electron scattering experiments. Achieving a MTE close to the thermal limit is a key step toward realizing the full potential of electron sources in these applications. Cesium antimonide (Cs 3 Sb) is a technologically important material with a long history of use in photon detection and electron sources. The smallest MTE of electrons photoemitted from Cs 3 Sb has always been appreciably greater than the thermal limit and was attributed to surface non-uniformities. In this work, we present comprehensive measurements of the photoemission electron energy spectra (PEES), quantum efficiency, and MTE from Cs 3 Sb in a wide photoexcitation energy range from 1.5 to 2.3 eV. Our PEES measurements demonstrate a notably low photoemission threshold of around 1.5 eV, which is in contrast with the previously perceived threshold of 1.8–2.0 eV. Moreover, we show that the MTE at this threshold of 1.5 eV nearly converges to the thermal limit at 300 K. At 1.8 eV, the MTE measured is 40 meV, which is comparable to the previously reported value. Here, we conclude that this MTE value at 1.8 eV photon energy is not due to surface roughness effects as previously believed, but is a direct consequence of the excess energy.

43 PARTICLE ACCELERATORS↗

MNSR transient analyses and thermal-hydraulic safety margins for HEU and LEU cores using PARET

Thermal-hydraulic performance characteristics of Miniature Neutron Source Reactors under long-term steady-state and transient conditions are investigated. Safety margins and limiting conditions attained during these events are determined. Modeling extensions are presented that enable the PARET/ANL code to realistically track primary loop heatup, heat exchange to the pool, and heat loss from the pool to air over the pool. Comparisons are made of temperature predictions for HEU and LEU fueled cores under transient conditions. Results are obtained using three different natural convection heat transfer correlations: the original (PARET/ANL version 5), Churchill-Chu, and an experiment- based correlation from the China Institute of Atomic Energy (CIAE). The MNSR, either fueled by HEU or by LEU, satisfies the design limits for long-term transient operation. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Energy Delivery System Design Basis Report

Nuclear power plants operate most efficiently and economically when they are operating at some constant power output. However, with the current dynamics of the grid, including the introduction and growth of renewable energy sources such as wind and solar, nuclear generation facilities across the U.S. are finding it difficult to keep their power supply constant and provide for baseload generation capacities. As a result, most nuclear plants are finding it hard to compete with other generation fuel sources, most notably, natural gas. Finding a solution to this intermittent power supply dynamic could help U.S. nuclear power plants economically compete with other generation fuel sources such as natural gas, wind, and solar. The Thermal Energy Delivery System (TEDS) at the INL aims to investigate alternative solutions to this dilemma. The TEDS design focuses on the delivery of thermal energy to different systems throughout the Dynamic Energy Transport and Integration laboratory (DETAIL). Its strategy revolves around allowing the system to operate at full generation output while storing any surplus energy for later use and/or additional function.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Radiation Analyzer

Thermal Radiation Analyzer System TRASYS II solves radiation related aspects of thermal analysis problems. TRASYS II provides for calculation of internode radiation interchange data and for calculation of incident and absorbed heat rate data originating from environmental radiant heat sources. When TRASYS II used in conjunction with generalized thermal analysis program such as Systems Improved Numerical Differencing Analyzer (SINDA), any thermal problem expressed in terms of lumped parameter RC thermal network solved.

Vogt, R. A.↗

High-resolution emission-line imaging of Seyfert galaxies. I - Observations. II - Evidence for anisotropic ionizing radiation

A CCD direct imaging survey of 11 Seyfert galaxies with a mean seeing of 1.3 arcsec FWHM is presented. It is found that the major axes and spatial scales of the circumnuclear emission-line gas are very similar to those of the radio continuum sources. In the second part, this close connection between thermal and relativistic gases is examined. A scenario is proposed in which the radio jets and plasmoids shock, accelerate, and compress ambient and entrained gas, with the dominant source of ionization being the nonstellar nuclear UV continuum.

Haniff, Christopher A.↗