Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Simulations of the new DARHT Axis-II bucking coil magnetic field and effects

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. The Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos was developed for flash radiography of large hydrodynamic experiments. Two linear induction accelerators (LIAs) produce the bremsstrahlung radiographic source spots for orthogonal views of each experiment (“hydrotest”). The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. For time resolution of the hydrotest dynamics, the 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by slicing them out of a longer pulse that has a 1.6-µs flattop. Both axes now routinely produce radiographic source spot sizes having full-width at half-maximum (FWHM) less than 1 mm.

43 PARTICLE ACCELERATORS↗

Impacts of Variability and Uncertainty in Solar Photovoltaic Generation at Multiple Timescales

The characteristics of variability and uncertainty of PV solar power have been studied extensively. These characteristics can create challenges for system operators who must ensure a balance between generation and demand while obeying power system constraints at the lowest possible cost. A number of studies have looked at the impact of wind power plants, and some recent studies have also included solar PV. The simulations that are used in these studies, however, are typically fixed to one time resolution. This makes it difficult to analyze the variability across several timescales. In this study, we use a simulation tool that has the ability to evaluate both the economic and reliability impacts of PV variability and uncertainty at multiple timescales. This information should help system operators better prepare for increases of PV on their systems and develop improved mitigation strategies to better integrate PV with enhanced reliability. Another goal of this study is to understand how different mitigation strategies and methods can improve the integration of solar power more reliably and efficiently.

14 SOLAR ENERGY↗

Dynamic temperature measurements with embedded optical sensors.

This report summarizes LDRD project number 151365, \Dynamic Temperature Measurements with Embedded Optical Sensors". The purpose of this project was to develop an optical sensor capable of detecting modest temperature states (<1000 K) with nanosecond time resolution, a recurring diagnostic need in dynamic compression experiments at the Sandia Z machine. Gold sensors were selected because the visible re ectance spectrum of gold varies strongly with temperature. A variety of static and dynamic measurements were performed to assess re ectance changes at di erent temperatures and pressures. Using a minimal optical model for gold, a plausible connection between static calibrations and dynamic measurements was found. With re nements to the model and diagnostic upgrades, embedded gold sensors seem capable of detecting minor (<50 K) temperature changes under dynamic compression.

Seagle, Christopher T↗

Evaluation of Clear Sky Models for Satellite-Based Irradiance Estimates

This report describes an intercomparison of three popular broadband clear sky solar irradiance model results with measured data, as well as satellite-based model clear sky results compared to measured clear sky data. The authors conclude that one of the popular clear sky models (the Bird clear sky model developed by Richard Bird and Roland Hulstrom) could serve as a more accurate replacement for current satellite-model clear sky estimations. Additionally, the analysis of the model results with respect to model input parameters indicates that rather than climatological, annual, or monthly mean input data, higher-time-resolution input parameters improve the general clear sky model performance.

14 SOLAR ENERGY↗

Ultrafast Thermal Transport at Interfaces

Our research program on Ultrafast Thermal Transport at Interfaces advanced understanding of the mesoscale science of heat conduction. At the length and time scales of atoms and atomic motions, energy is transported by interactions between single-particle and collective excitations. At macroscopic scales, entropy, temperature, and heat are the governing concepts. Key gaps in fundamental knowledge appear at the transitions between these two regimes. The transport of thermal energy at interfaces plays a pivotal role in these scientific issues. Measurements of heat transport with ultrafast time resolution are needed because picoseconds are the fundamental scales where the lack of equilibrium between various thermal excitations becomes a important factor in the transport physics. A critical aspect of our work has been the development of experimental methods and model systems that enabled more precise and sensitive investigations of nanoscale thermal transport.

36 MATERIALS SCIENCE↗

Velocimetry from details to the big picture and back

Slides used by Matthew Briggs for a talk given at the Colorado School of Mines. Points in this talk are summarized as follows: 1) Because velocity is one of the fundamental quantities in the physical description of shock physics, and because it can now be measured with nanosecond time resolution, <1% accuracy, for 100s of channels in a small confined space, optical velocimetry is growing dramatically in applications to shock physics. 2) Velocimetry is one of many critical pieces in the weapons labs mission to certify our nations stockpile. 3) The breadth of this mission means a very wide array of opportunities at LANL and other weapons labs.

47 OTHER INSTRUMENTATION↗

Target and orbit feedback simulations of a muSR beam line at BNL

Well-polarized positive surface muons are a tool to measure the magnetic properties of materials since the precession rate of the spin can be determined from the observation of the positron directions when the muons decay. For a dc beam an ideal µSR flux for surface µ + should be about 40 kHz/mm 2 . In this report we show how this flux could be achieved in a beam line using the AGS complex at BNL for a source of protons. We also determined that an orbit feedback system with a pair of thin silicon position monitors and kickers would miss the desired flux by at least an order of magnitude, even with perfect time resolution and no multiple scattering.

43 PARTICLE ACCELERATORS↗

Shift Register Clock Rate Effects on Coincidence Collection 50MHz versus 4MHz Comparison Tests

The following report identifies and quantifies the timing differences between the older slower Shift Register Coincidence/Multiplicity modules and today’s modern higher speed devices. Modern high speed Shift Register Coincidence/Multiplicity instruments employ high speed internal clocks that run at frequencies more than ten times the older units, typically 50MHz. These higher speed clocks allow for a finer time resolution when recording input pulses.

Nuclear Disarmament, Safeguards, & Physical Protec↗

2D Gridded Surface Data Value-Added Product

This report describes the Atmospheric Radiation Measurement (ARM) Best Estimate (ARMBE) 2-dimensional (2D) gridded surface data (ARMBE2DGRID) value-added product. Spatial variability is critically important to many scientific studies, especially those that involve processes of great spatial variations at high temporal frequency (e.g., precipitation, clouds, radiation, etc.). High-density ARM sites deployed at the Southern Great Plains (SGP) allow us to observe the spatial patterns of variables of scientific interests. The upcoming megasite at SGP with its enhanced spatial density will facilitate the studies at even finer scales. Currently, however, data are reported only at individual site locations at different time resolutions for different datastreams. It is difficult for users to locate all the data they need and requires extra effort to synchronize the data. To address these problems, the ARMBE2DGRID value-added product merges key surface measurements at the ARM SGP sites and interpolates the data to a regular 2D grid to facilitate the data application.

47 OTHER INSTRUMENTATION↗

Simulations of a PSD Plastic Neutron Collar for Assaying Fresh Fuel

The potential performance of a notional active coincidence collar for assaying uranium fuel based on segmented detectors constructed from the new PSD plastic fast organic scintillator with pulse shape discrimination capability was investigated in simulation. Like the International Atomic Energy Agency's present Uranium Neutron Collar for LEU (UNCL), the PSD plastic collar would also function by stimulating fission in the 235 U content of the fuel with a moderated 241 Am/Li neutron source and detecting instances of induced fission via neutron coincidence counting. In contrast to the moderated detectors of the UNCL, the fast time scale of detection in the scintillator eliminates statistical errors due to accidental coincidences that limit the performance of the UNCL. However, the potential to detect a single neutron multiple times historically has been one of the properties of organic scintillator detectors that has prevented their adoption for international safeguards applications. Consequently, as part of the analysis of simulated data, a method was developed by which true neutron-neutron coincidences can be distinguished from inter-detector scatter that takes advantage of the position and timing resolution of segmented detectors. Then, the performance of the notional simulated coincidence collar was evaluated for assaying a variety of fresh fuels, including some containing burnable poisons and partial defects. In these simulations, particular attention was paid to the analysis of fast mode measurements. In fast mode, a Cd liner is placed inside the collar to shield the fuel from the interrogating source and detector moderators, thereby eliminating the thermal neutron flux that is most sensitive to the presence of burnable poisons that are ubiquitous in modern nuclear fuels. The simulations indicate that the predicted precision of fast mode measurements is similar to what can be achieved by the present UNCL in thermal mode. For example, the statistical accuracy of a ten-minute measurement of fission coincidences collected in fast mode will be approximately 1% for most fuels of interest, yielding a ~1.4% error after subtraction of a five minute measurement of the spontaneous fissions from 238 U in the fuel, a ~2% error in analyzed linear density after accounting for the slope of the calibration curve, and a ~2.9% total error after addition of an assumed systematic error of 2%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved Estimates of Moments and Winds from Radar Wind Profiler

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) operates nine radar wind profilers (RWP) across its sites. These RWPs operate at 915 MHz or 1290 MHz frequency and report the first three moments of the Doppler spectrum. The operational settings of the RWP were modified in summer, 2015 to have single pulse length setting for the wind mode and two pulse length settings for the precipitation mode. The moments data collected during the wind mode are used to retrieve horizontal winds. The vendor-reported winds are available at variable time resolution (10 mins, 60 mins, etc.) and contain a significant amount of contamination due to noise and clutter. In this data product we have recalculated the moments and the winds from the raw radar Doppler spectrum and have made efforts to mitigate the contamination due to instrument noise in the wind estimates. Additionally, the moments and wind data has been reported in a harmonized layout identical for all locations and sites.

47 OTHER INSTRUMENTATION↗

Mixing and CP violation in the B$0\atop{s}$ meson system at CDF; Mélange et violation de CP dans le système des mésons B$0\atop{s}$ à CDF

The two analyses presented in the thesis, the B$0\atop{s}$ mixing analysis and the B$0\atop{s}$ → J/ψφ angular analysis, share most of the technical implementations and features. Thus, my choice was to pursue in parallel the common aspects of the analyses, avoiding, whenever possible, repetitions. Each Chapter is split in two parts, the first one dedicated to the B$0\atop{s}$ mixing analysis and the second one describing the angular analysis on the B$0\atop{s}$ → J/ψφ decay mode. They are organized as follows. In Chapter 1 we present the theoretical framework of the B$0\atop{s}$ neutral mesons system. After a general introduction on the Standard Model, we focus on the quantities which are relevant to the Δms measurement and the CP violation phenomena, underlying the details concerning the study of pseudo-scalar to vector vector decays, P → VV, which allow to carry out an angular analysis. A discussion on the implication of the measurements performed in the search of physics beyond the Standard Model is presented. The accelerator facilities and the CDF-II detector are reported in Chapter 2. While describing the detector, more emphasis is given to the components fundamental to perform B physics analyses at CDF. The Chapter 3 is focused on the reconstruction and selection of the data samples. The Chapter starts with a description of the on-line trigger requirements, according to the B$0\atop{s}$ sample considered, followed by the offline selection criteria implemented to reconstruct B$0\atop{s}$ semileptonic and hadronic decays, fully and partially reconstructed, for the B$0\atop{s}$ mixing analysis, as well as the B$0\atop{s}$ → J/ψφ decay mode for the angular analysis. The subsequent Chapter 4 is dedicated to the revision of the technical ingredients needed in the final analyses. The B$0\atop{s}$ mixing elements are firstly described. The methodology historically used in the oscillation searches, the 'amplitude scan', is here introduced together with the calibration of the proper-decay-time resolution and the flavor tagging algorithms, in particular a closer examination of the same-side tagger performances is given. The B$0\atop{s}$ → J/ψφ angular analysis elements description then follows, focusing on the performances and the eventual differences with respect to the B$0\atop{s}$ oscillation search. The final results of the analyses are obtained with the use of an un-binned likelihood fitting framework: Chapter 5 presents the general principles behind this methodology and a description of both the maximum likelihood fitters employed. Chapter 6 contains the conclusive results on the B$0\atop{s}$ analyses. They are presented in an historical fashion: the measurement of the B$0\atop{s}$ oscillation frequency is followed by the first flavor tagged ΔΓs and βs measurements. The impact and the constraints on the parameters of the flavor model is part of the discussion in the Chapter. As cross-check of the B$0\atop{s}$ angular analysis, the B$0\atop{s}$ → J/ψK*0 decay mode has been additionally studied. Its angular analysis shows a competitive sensitivity with the B factories in measuring the parameters which define the decay. Not only this contributes to enforce the reliability of the entire framework, but it constitutes an excellent result by itself. Thus, we devote the entire Chapter 7 to the sole discussion of the angular analysis of the B$0\atop{s}$ → J/ψK*0 decay mode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Scientific Report: DE-SC0002194

We provide the final scientific report for DE-SC0002194. During the term of this grant, 28 publications spanning a variety of topics were addressed under the rubric of advanced x-ray methods and their application to extreme conditions of time-resolution or x-ray intensities. Notable accomplishments include a new observation of XANES features associated with f-shell reconfiguration in lanthanides, size-dependent x-ray heating effects under XFEL illumination conditions, theoretical development of improved treatments of inelastic x-ray scattering for 'warm dense matter' conditions, and several new instrument develop efforts for atomic, molecular, and condensed phase studies in the lab and at major facility lightsources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GlueX Start Counter and Beam Asymmetry$\Sigma$ in Single $\pi^{0}$ Photoproduction

The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H 2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 10 8 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\vec{p}$→ π 0 p, where π 0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Timing with Silicon Photomultipliers

• CMS MTD is important for an expanded physics reach : we expect 20- 25% effective luminosity increase in crucial precision Higgs measurements. • Our project is significantly advanced – the sensor performance is close to specification. • We are heavily involved in efforts to ensure 30 ps time resolution for sensors throughout the HL-LHC run.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stilbene Scintillator Detector Array and Data-Acquisition System for Active Interrogation

A large area Stilbene crystal detector array has been assembled and calibrated for use in active interrogation measurements. The array consists of 10 high-efficiency 4”x2” stilbene cells. The cells were grown by Inrad Optics using LLNL developed technology. The array can be used to detect multiple signatures of SNM items, both actively and passively. Prompt and delayed gamma rays as well as prompt and delay neutrons can be detected and counted separately. The array is coupled to the Mesytec MDPP-16 VME-based digitizer module for data acquisition. This module performs on-board pulse-shape discrimination of signals from the Stilbene crystal detectors. This data-acquisition module allows separation of neutron and gamma-ray events with a low demand on data transfer rates. In addition, the high-resolution timing (<100 ps) is suitable for correlated gamma-ray and neutron multiplicity counting. This report describes the construction and calibration of the system. We also discuss applications of the system as well as how the system is currently being utilized by end users.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Final Technical Report for DE-SC0008502

This work led to the development of an algorithm to retrieve cloud microphysical properties (optical depth and effective particle size) form shortwave spectral radiometric irradiance measured at the earth surface in the wavelength interval 1000-1600 nm. Recent instruments such as the ARM Program’s Shortwave Array Spectrometer (SAS) can record irradiance spectra in cadences as short as one minute, providing valuable information about time evolution of cloud properties involved with formation, precipitation and dissipation. A primary advantage of shortwave spectral measurements over the middle-infrared is that cloud properties can be retrieved over a much larger range in liquid water path (LWP), as the instrument is measuring irradiance transmitted through cloud. In the middle infrared, a cloud behaves as a blackbody for optical depths larger than approximately five, and for larger LWP surface longwave spectral measurements are insensitive to cloud microphysics. Research supported by this award has demonstrated the viability of the retrieval technique and the utility of high time resolution spectral measurements (Lubin et al. 2018a; Wilson et al. 2018).

47 OTHER INSTRUMENTATION↗

Wavelength Conversion Arrays for Optical and X-Ray Diagnostics at Z

Optical diagnostics play a central role in dynamic compression research. Currently, streak cameras are employed to record temporal and spectroscopic information in single-event experiments, yet are limited in several ways; the tradeoff between time resolution and total record duration is one such limitation. This project solves the limitations that streak cameras impose on dynamic compression experiments while reducing both cost and risk (equipment and labor) by utilizing standard high-speed digitizers and commercial telecommunications equipment. The missing link is the capability to convert the set of experimental (visible/x-ray) wavelengths to the infrared wavelengths used in telecommunications. In this report, we describe the problem we are solving, our approach, our results, and describe the system that was delivered to the customer. The system consists of an 8-channel visible-to-infrared converter with > 2 GHz 3-dB bandwidth.

42 ENGINEERING↗