Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Simulation of PV Variability as a Function of PV Generation and Plant Size

The deployment of photovoltaic (PV) systems continues to show significant expansion; however, this growth has brought added attention to issues around the variability of the solar resource. Both spatial and temporal variability exist. Temporal scales can range from the sub-second to multiyear, whereas spatial scales can range from a few meters to tens of kilometers. There are multiple methods described in the literature to quantify PV variability at various spatial and temporal scales. This study focuses on short-term temporal variability and uses similar approaches with the addition of PV plant size a parameter to quantify variability. The method employed here incorporates the normalization of clear-and cloudy-sky conditions and PV plant size to quantify nominal variability metrics. The distribution and fluctuations of these metrics provide relevant information that is useful for system operations. The National Solar Radiation Database (NSRDB) is used to simulate PV variability as a function of PV generation and plant size. Hypothetical but realistic system information at 33 locations is used to model PV generation by feeding NSRDB solar irradiance data to the National Renewable Energy Laboratory’s System Advisor Model (SAM). Over the selected region, it is found that the aggregated ramp rates for the 1-minute data are associated with standard deviations ranging from 0.002–0.055 on a daily basis; however, hourly intervals induce higher aggregated ramp rates than the other timescales. Even though minute-to-minute variations are significant for the 1-minute time-scale, the standard deviation aggregated into a daily metric is smaller because of the cancellation of values.

irradiance↗

Preparation and Magnetic Properties of Sub-Micrometer Sized Sm-Co Powders Prepared From Nanostructured Precursor Oxides

Submicrometer-sized Sm-Co powders have been prepared by the calciothermic reduction and subsequent solid-state diffusion of a nanostructured Sm-Co-O/Co-O precursor. The Sm and Co containing precursor was prepared by an autocombustion process. X-ray diffraction identified the product as a mixture of SmCoO3 and Co-3 O-4. This powder was mixed in a 1:2 mass ratio with CaO (which served as a thermal ballast and aggregation inhibitor) and milled to reduce the particle size below 1 micrometer. Ca metal was added to the mixed powder in amounts between 2 and 6 times those required to reduce the Sm and Co oxides, and sealed in Nb tubes for heat treatment at 900 degrees C for various lengths of time. After cooling to room temperature, metallic Sm-Co particles were isolated from the undesired reaction products by a series of washing steps in acetic acid and ethyl alcohol. The Sm-Co particles were characterized by scanning electron microscopy, vibrating sample magnetometry, and x-ray diffraction. These measurements demonstrated that smaller particle sizes were associated with shorter reaction times and smaller quantities of reducing agent. The formation of hard SmCo5 was systematically associated with either long diffusion times with small amounts of reducing agent, or short diffusion times with large amounts of reducing agent.

Kelly, BG↗

Traditional plant functional groups explain variation in economic but not size-related traits across the tundra biome

Aim: Plant functional groups are widely used in community ecology and earth system modelling to describe trait variation within and across plant communities. However, this approach rests on the assumption that functional groups explain a large proportion of trait variation among species. We test whether four commonly used plant functional groups represent variation in six ecologically important plant traits. Location: Tundra biome. Time period: Data collected between 1964 and 2016. Major taxa studied: 295 tundra vascular plant species. Methods: We compiled a database of six plant traits (plant height, leaf area, specific leaf area, leaf dry matter content, leaf nitrogen, seed mass) for tundra species. We examined the variation in species-level trait expression explained by four traditional functional groups (evergreen shrubs, deciduous shrubs, graminoids, forbs), and whether variation explained was dependent upon the traits included in analysis. We further compared the explanatory power and species composition of functional groups to alternative classifications generated using post-hoc clustering of species-level traits. Results: Traditional functional groups explained significant differences in trait expression, particularly among traits associated with resource economics, which were consistent across sites and at the biome scale. However, functional groups explained 19% of overall trait variation and poorly represented differences in traits associated with plant size. Post-hoc classification of species did not correspond well with traditional functional groups, and explained twice as much variation in species-level trait expression. Main conclusion: Traditional functional groups only coarsely represent variation in well-measured traits within tundra plant communities, and better explain resource economic traits than size-related traits. We recommend caution when using functional group approaches to predict tundra ecosystem change, or ecosystem functions relating to plant size, such as albedo or carbon storage. We argue that alternative classifications or direct use of specific plant traits could provide new insight for ecological prediction and modelling.

59 BASIC BIOLOGICAL SCIENCES↗

Size effects in 3D–printed polymer–derived, zirconium diboride–reinforced ceramic composites

Preceramic polymers are of interest for use in many manufacturing techniques such as injection molding, ceramic fiber infiltration, and additive manufacturing. However, off-gassing of low molecular weight oligomers occurs when these polymers cure, potentially leading to porosity in the cured part. Here to study how porosity and strength are affected by the size of the printed part, and the presence of a high surface area nano-scale filler, polycarbosilane (PCS) microrods of varying diameter were fabricated via direct ink writing (DIW), an additive manufacturing technique, with two ink formulations containing either zirconium diboride (ZrB 2 ) alone, or ZrB 2 and fumed alumina (FA). Sets of microrods were printed in a range of sizes by using print nozzles of 450, 634, 979, 1 346, or 1 702 μm in diameter, which were thermally cured, pyrolyzed to form ceramic composite microrods, and tested in 3-pt flexure. Porosity increased with increasing diameter, while failure strength decreased. For a given nozzle size, the microrods containing FA displayed lower porosity and higher strength (up to ~500 MPa) compared to the microrods containing only ZrB 2 . Weibull strength analysis was performed on each group of microrods and shows that the addition of FA increased Weibull modulus from 4.63 ± 1.56 to 9.35 ± 0.601. In conjunction with optical microscopy, this analysis indicates two distinct flaw populations in the printed materials, porosity which arises during the curing step and cracking which arises during pyrolysis of the larger specimens.

36 MATERIALS SCIENCE↗

Size-related decline in dryland shrubs is related to reductions in hydraulic efficiency and carbon assimilation and not nonstructural carbohydrate depletion

Plant growth and survival are fundamentally constrained by water transport from roots to leaves, impacting carbon assimilation and associated labile carbon pools. However, physiological constraints on growth and survival vary with plant age, due to changes in metabolic sinks, and increases in hydraulic path length from rhizosphere to canopy. We investigated crown dieback, growth, hydraulics, carbon assimilation and carbohydrate storage in relation to increasing basal diameter of two dominant shrub species (Caragana korshinskii and Artemisia ordosica) at the southeastern edge of the Tengger Desert, China. The aim was to identify mechanisms of decreased performance with plant size in dryland shrubs. Clear contrasts in stomatal regulation of leaf water potentials were detected between species. Despite these contrasts, radial growth, hydraulic transport efficiency (Ks), and photosynthetic efficiency similarly declined in both species with increasing plant size, while non-structural carbohydrate (NSC) reserves remained unchanged. Xylem embolism (PLC) increased with plant size, resulting in significant reductions in carbon assimilation in both species. Results indicate that hydraulic, and potentially carbon assimilation constraints, rather than reductions in carbohydrate storage, govern growth-related dryland shrub decline. These findings improve our understanding of how population demography impacts dryland forest response to climate change.

Zhang, Hongxia↗

Light regulation of light-harvesting antenna size substantially enhances photosynthetic efficiency and biomass yield in green algae

One of the major factors limiting biomass productivity in algae is the low thermodynamic efficiency of photosynthesis. The greatest thermodynamic inefficiencies in photosynthesis occur during the conversion of light into chemical energy. At full sunlight the light-harvesting antenna captures photons at a rate nearly 10 times faster than the rate-limiting step in photosynthetic electron transport. Excess captured energy is dissipated by non-productive pathways including the production of reactive oxygen species. Substantial improvements in photosynthetic efficiency have been achieved by reducing the optical cross-section of the light-harvesting antenna by selectively reducing chlorophyll b levels and peripheral light-harvesting complex subunits. Smaller light-harvesting antenna, however, may not exhibit optimal photosynthetic performance in low or fluctuating light environments. Additionally, we describe a translational control system to dynamically adjust light-harvesting antenna sizes for enhanced photosynthetic performance. Furthermore, by expressing a chlorophyllide a oxygenase (CAO) gene having a 5' mRNA extension encoding a Nab1 translational repressor binding site in a CAO knockout line it was possible to continuously alter chlorophyll b levels and correspondingly light-harvesting antenna sizes by light-activated Nab1 repression of CAO expression as a function of growth light intensity. Significantly, algae having light-regulated antenna sizes had substantially higher photosynthetic rates and two-fold greater biomass productivity than the parental wild-type strains as well as near wild-type ability to carry out state transitions and non-photochemical quenching. These results have broad implications for enhanced algae and plant biomass productivity.

09 BIOMASS FUELS↗

The effect of nanoparticle enhanced sizing on the structural health monitoring sensitivity and mechanical properties of carbon fiber composites

With current carbon composites being introduced into new commercial market sectors, there is an opportunity to develop multifunctional composites, which are poised to be the next generation of composites that will see future commercial applications. This multifunctional attribute can be achieved via integrated nanomaterials, which are currently under-utilized in real-world applications despite significant research efforts focused on their synthesis. This research utilizes a simple, scalable approach to integrate various nanomaterials into carbon fiber composites by embedding the nanomaterials in the epoxy fiber sizing. Illustrated in this work is the effect of silicon carbide nanoparticle concentrations and dimensions on the structural health monitoring sensitivity of unidirectional carbon fiber composites. Additionally, the nanoparticles contribute to the overall damping property of the composites thus enabling tunable damping through simple variations in nanoparticle concentration and size. Not only does this nanoparticle sizing offer enhanced sensitivity and tunable damping, but it also maintains the mechanical integrity and performance of the composites, which demonstrates a truly multifunctional composite. Therefore, this research establishes an efficient route for combining nanomaterials research with real-world multifunctional composite applications using a technique that is easily scalable to the commercial level and is compatible with a wide range of fibers and nanomaterials.

Bowland, Christopher↗

Examination of a Size-Change Test for Photovoltaic Encapsulation Materials: Preprint

We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International ElectrotechnicalCommission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sandsubstrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/- 5C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). Thetest procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/- 5% between laboratories.

14 SOLAR ENERGY↗

Is there a single spot size and grid for intensity modulated proton therapy? Simulation of head and neck, prostate and mesothelioma cases

Purpose: To assess the quality of dose distributions in real clinical cases for different dimensions of scanned proton pencil beams. The distance between spots (i.e., the grid of delivery) is optimized for each dimension of the pencil beam. Methods: The authors vary the {sigma} of the initial Gaussian size of the spot, from {sigma}{sub x} = {sigma}{sub y} = 3 mm to {sigma}{sub x} = {sigma}{sub y} = 8 mm, to evaluate the impact of the proton beam size on the quality of intensity modulated proton therapy (IMPT) plans. The distance between spots, {Delta}x and {Delta}y, is optimized on the spot plane, ranging from 4 to 12 mm (i.e., each spot size is coupled with the best spot grid resolution). In our Hyperion treatment planning system (TPS), constrained optimization is applied with respect to the organs at risk (OARs), i.e., the optimization tries to satisfy the dose objectives in the planning target volume (PTV) as long as all planning objectives for the OARs are met. Three-field plans for a nasopharynx case, two-field plans for a prostate case, and two-field plans for a malignant pleural mesothelioma case are considered in our analysis. Results: For the head and neck tumor, the best grids (i.e., distance between spots) are 5, 4, 6, 6, and 8 mm for {sigma} = 3, 4, 5, 6, and 8 mm, respectively. {sigma} {<=} 5 mm is required for tumor volumes with low dose and {sigma}{<=} 4 mm for tumor volumes with high dose. For the prostate patient, the best grid is 4, 4, 5, 5, and 5 mm for {sigma} = 3, 4, 5, 6, and 8 mm, respectively. Beams with {sigma} > 3 mm did not satisfy our first clinical requirement that 95% of the prescribed dose is delivered to more than 95% of prostate and proximal seminal vesicles PTV. Our second clinical requirement, to cover the distal seminal vesicles PTV, is satisfied for beams as wide as {sigma} = 6 mm. For the mesothelioma case, the low dose PTV prescription is well respected for all values of {sigma}, while there is loss of high dose PTV coverage for {sigma} > 5 mm. The best grids have a spacing of 6, 7, 8, 9, and 12 mm for {sigma} = 3, 4, 5, 6, and 8 mm, respectively. Conclusions: The maximum acceptable proton pencil beam {sigma} depends on the volume treated, the protocol of delivery, and optimization of the plan. For the clinical cases, protocol and optimization used in this analysis, acceptable {sigma}s are {<=} 4 mm for the head and neck tumor, {<=} 3 mm for the prostate tumor and {<=} 6 mm for the malignant pleural mesothelioma. One can apply the same procedure used in this analysis when given a ''class'' of patients, a {sigma} and a clinical protocol to determine the optimal grid spacing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibrating page sized Gafchromic EBT3 films

Purpose: The purpose is the development of a novel calibration method for dosimetry with Gafchromic EBT3 films. The method should be applicable for pretreatment verification of volumetric modulated arc, and intensity modulated radiotherapy. Because the exposed area on film can be large for such treatments, lateral scan errors must be taken into account. The correction for the lateral scan effect is obtained from the calibration data itself. Methods: In this work, the film measurements were modeled using their relative scan values (Transmittance, T). Inside the transmittance domain a linear combination and a parabolic lateral scan correction described the observed transmittance values. The linear combination model, combined a monomer transmittance state (T{sub 0}) and a polymer transmittance state (T{sub {infinity}}) of the film. The dose domain was associated with the observed effects in the transmittance domain through a rational calibration function. On the calibration film only simple static fields were applied and page sized films were used for calibration and measurements (treatment verification). Four different calibration setups were considered and compared with respect to dose estimation accuracy. The first (I) used a calibration table from 32 regions of interest (ROIs) spread on 4 calibration films, the second (II) used 16 ROIs spread on 2 calibration films, the third (III), and fourth (IV) used 8 ROIs spread on a single calibration film. The calibration tables of the setups I, II, and IV contained eight dose levels delivered to different positions on the films, while for setup III only four dose levels were applied. Validation was performed by irradiating film strips with known doses at two different time points over the course of a week. Accuracy of the dose response and the lateral effect correction was estimated using the dose difference and the root mean squared error (RMSE), respectively. Results: A calibration based on two films was the optimal balance between cost effectiveness and dosimetric accuracy. The validation resulted in dose errors of 1%-2% for the two different time points, with a maximal absolute dose error around 0.05 Gy. The lateral correction reduced the RMSE values on the sides of the film to the RMSE values at the center of the film. Conclusions: EBT3 Gafchromic films were calibrated for large field dosimetry with a limited number of page sized films and simple static calibration fields. The transmittance was modeled as a linear combination of two transmittance states, and associated with dose using a rational calibration function. Additionally, the lateral scan effect was resolved in the calibration function itself. This allows the use of page sized films. Only two calibration films were required to estimate both the dose and the lateral response. The calibration films were used over the course of a week, with residual dose errors Less-Than-Or-Slanted-Equal-To 2% or Less-Than-Or-Slanted-Equal-To 0.05 Gy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-07: A Comparison of SSD and Field Size Dependence of Output for Megavoltage Electron Beams for Different Manufacturers

Purpose: The purpose of this study was to compare the electron beam in-air output factor (H) for Varian and Siemens accelerators. Methods: Measurements were performed among four accelerators: Varian CL2300ix, Varian TrueBeam, Siemens Oncor, and Siemens Primus. The nominal electron energy measured ranges from 6 to 21 MeV. Measurements were made in air using a diode detector for different square cone sizes (6 – 25cm) with circular field inserts with radius r between 1 cm and 8 cm and for different SSD (100 – 120 cm). H is defined asH(r,SSD){sup =} X(r,SSD)/X(open,SSD), where X is the charge measured by the diode detector without buildup cap in air. Results: For the same nominal energy, cone size, radius of circular cutout, and SSD, H agreed within a maximum deviation of 2.3% and standard deviation of 1% among Varian accelerators but can be as much as 8.7% different between the Varian and the Siemens accelerators. H is a function of electron energy and cutout radius only when the field radius for H measured at different SSD is renormalized as r = r0*5/(SSD-95), where r{sub 0} is the physical field radius at the end of the cone. The radius dependence of H for five cone sizes (6×6, 10×10, 15×15, 20×20 and 25×25cm{sup 2}) and three SSD(100, 110 and 120cm) for three energies was measured. Conclusion: The in air output factor (H) measured for the same manufacturer can be treated as identical to within 1.1% for Varian machines and to within 1.6% for Siemens machines, but the difference in H measured for the different manufacturers is large enough (>2%) to require machine specific data set.

43 PARTICLE ACCELERATORS↗

SU-E-T-141: Effect of a Single Gold Nanoparticle with Different Sizes Inside a Small Water Phantom

Purpose: This study is to investigate the effects of the gold nanoparticles (GNP), a series of micrometre scale simulations have been constructed with Geant4 to track particles and simulate the effects of those particles as they pass through water phantom. Methods: The simulations were used to calculate the number of secondary electrons which are emitted from the particle tracks and the amount of energy which is deposited in the cell tissue. More electrons means that more water molecules can undergo hydrolysis and create potentially dangerous free radical molecules, therefore breaking up DNA and killing off cells or causing damaging mutations. Results: For the 20nm GNP, all three proton energies saw a small increase of electrons above the control, while the X-rays nearly tripled the number of electrons in the phantom. For the 50 nm GNP, the 3 and 2 MeV protons saw a small increase again, however the 1 MeV protons saw a decrease in electrons, the X-rays saw a large increase of nearly 4 times the number of electrons. For the 110nm GNP, all three proton energies saw a decrease in the total number of electrons in the phantom, while the X-rays saw an increase of 8 times as many electrons. Conclusion: From the range of GNP sizes used, it was found that the X-rays have a larger dose enhancement effect as the GNP size increases, the relation between electron emissions and GNP size was linear. This is because the majority of the dose from the X-rays is delivered to the cell tissue through the initial high energy secondary electrons, any dose lost from the Augerelectrons being trapped inside the GNP volume is small compared to the dose that escapes with the high energy electrons.

60 APPLIED LIFE SCIENCES↗

SU-E-T-299: Small Fields Profiles Correction Through Detectors Spatial Response Functions and Field Size Dependence Analysis

Purpose: To calculate the spatial response function of various radiation detectors, to evaluate the dependence on the field size and to analyze the small fields profiles corrections by deconvolution techniques. Methods: Crossline profiles were measured on a Novalis Tx 6MV beam with a HDMLC. The configuration setup was SSD=100cm and depth=5cm. Five fields were studied (200×200mm2,100×100mm2, 20×20mm2, 10×10mm2and 5×5mm2) and measured were made with passive detectors (EBT3 radiochromic films and TLD700 thermoluminescent detectors), ionization chambers (PTW30013, PTW31003, CC04 and PTW31016) and diodes (PTW60012 and IBA SFD). The results of passive detectors were adopted as the actual beam profile. To calculate the detectors kernels, modeled by Gaussian functions, an iterative process based on a least squares criterion was used. The deconvolutions of the measured profiles were calculated with the Richardson-Lucy method. Results: The profiles of the passive detectors corresponded with a difference in the penumbra less than 0.1mm. Both diodes resolve the profiles with an overestimation of the penumbra smaller than 0.2mm. For the other detectors, response functions were calculated and resulted in Gaussian functions with a standard deviation approximate to the radius of the detector in study (with a variation less than 3%). The corrected profiles resolve the penumbra with less than 1% error. Major discrepancies were observed for cases in extreme conditions (PTW31003 and 5×5mm2 field size). Conclusion: This work concludes that the response function of a radiation detector is independent on the field size, even for small radiation beams. The profiles correction, using deconvolution techniques and response functions of standard deviation equal to the radius of the detector, gives penumbra values with less than 1% difference to the real profile. The implementation of this technique allows estimating the real profile, freeing from the effects of the detector used for the acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, and B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-51: Investigating the Effect of Eye Size and Eccentricity On Normal Tissue Doses From Eye Plaque Brachytherapy

Purpose: This study investigates the effect of eye size and eccentricity on doses to critical tissues by simulating doses in the Plaque Simulator (v. 6.3.1) software. Present OHSU plaque brachytherapy treatment focuses on delivering radiation to the tumor measured with ocular ultrasound plus a small margin and assumes the orbit has the dimensions of a “standard eye.” Accurately modeling the dimensions of the orbit requires a high resolution ocular CT. This study quantifies how standard differences in equatorial diameters and eccentricity affect calculated doses to critical structures in order to query the justification of the additional CT scan to the treatment planning process. Methods: Tumors of 10 mm × 10 mm × 5 mm were modeled at the 12:00:00 hour with a latitude of 45 degrees. Right eyes were modeled at a number of equatorial diameters from 17.5 to 28 mm for each of the standard non-notched COMS plaques with silastic inserts. The COMS plaques were fully loaded with uniform activity, centered on the tumor, and prescribed to a common tumor dose (85 Gy/100 hours). Variations in the calculated doses to normal structures were examined to see if the changes were significant. Results: The calculated dose to normal structures show a marked dependence on eye geometry. This is exemplified by fovea dose which more than doubled in the smaller eyes and nearly halved in the larger model. Additional significant dependence was found in plaque size on the calculated dose in spite of all plaques giving the same dose to the prescription point. Conclusion: The variation in dose with eye dimension fully justifies the addition of a high resolution ocular CT to the planning technique. Additional attention must be made to plaque size beyond simply covering the tumor when considering normal tissue dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-161: The Effect of Pencil Beam Scanning Gantry Angle Dependent Spot Size Variations On Plan Quality

Purpose: To investigate the effect of spot size variation as function of gantry angle on the quality of treatment plans for pencil beam scanning proton plans. Method: Three homogeneous 26×26×7cm dose volumes with different ranges and SOBPs were delivered on the matrixxPT 2D array at gantry angles of 0 and 270 degrees. The spot size sigma varies by 1.8, 7.8, and 1.4%, for nominal energies of 215, 183, and 103 MeV (Range 29, 22, and 8cm, respectively). The resulting dose planes are compared and evaluated with the gamma index for 2%/2mm and 1%/1mm criteria. Results: Patient specific QA is performed at a gantry angle of 0 degrees. However, beam sigmas vary as function of gantry angle because of the beam optics for each gantry. This will cause differences between the delivered and planned treatment plans. Delivered plans were compared and a gamma pass rate of 96.5% for criteria of 2%/2mm and 91.4% for 1%/1mm were seen for plans with a nominal energy of 183 MeV. For plans with a nominal energy of 103 MeV, gamma pass rates of 97.3% for 2%/2mm and 91.5% for 1%/1mm were seen. For plans with a nominal energy of 215 MeV the pass rate was 99.8% for 1%/1mm between the two gantry angles. Conclusion: Differences in beam sigma of up to 7.8% do not cause significant differences in the dose distribution of different spot size gammas.

60 APPLIED LIFE SCIENCES↗

SU-F-T-574: MLC Based SRS Beam Commissioning - Minimum Target Size Investigation

Purpose: To implement a MLC accelerator based SRS program using small fields down to 1 cm × 1 cm and to determine the smallest target size safe for clinical treatment. Methods: Computerized beam scanning was performed in water using a diode detector and a linac-head attached transmission ion chamber to characterize the small field dosimetric aspects of a 6 MV photon beam (Trilogy-Varian Medical Systems, Inc.). The output factors, PDD and profiles of field sizes 1, 2, 3, 4, and 10 cm{sup 2} were measured and utilized to create a new treatment planning system (TPS) model (AAA ver 11021). Static MLC SRS treatment plans were created and delivered to a homogeneous phantom (Cube 20, CIRS, Inc.) for a 1.0 cm and 1.5 cm “PTV” target. A 12 field DMLC plan was created for a 2.1 cm target. Radiochromic film (EBT3, Ashland Inc.) was used to measure the planar dose in the axial, coronal and sagittal planes. A micro ion chamber (0.007 cc) was used to measure the dose at isocenter for each treatment delivery. Results: The new TPS model was validated by using a tolerance criteria of 2% dose and 2 mm distance to agreement. For fields ≤ 3 cm{sup 2}, the max PDD, Profile and OF difference was 0.9%, 2%/2mm and 1.4% respectively. The measured radiochromic film planar dose distributions had gamma scores of 95.3% or higher using a 3%/2mm criteria. Ion chamber measurements for all 3 test plans effectively met our goal of delivering the dose accurately to within 5% when compared to the expected dose reported by the TPS (1 cm plan Δ= −5.2%, 1.5 cm plan Δ= −2.0%, 2 cm plan Δ= 1.5%). Conclusion: End to end testing confirmed that MLC defined SRS for target sizes ≥ 1.0 cm can be safely planned and delivered.

07 ISOTOPE AND RADIATION SOURCES↗

WE-FG-207B-09: Experimental Assessment of Noise and Spatial Resolution in Virtual Non-Contrast Dual-Energy CT Images Across Multiple Patient Sizes and CT Systems

Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150 and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗