Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Sample Handling in Extreme Environments

Harsh environments, such as that on Venus, preclude the use of existing equipment for functions that involve interaction with the environment. The operating limitations of current high temperature electronics are well below the actual temperature and pressure found on Venus (460 deg C and 92 atm), so proposed lander configurations typically include a pressure vessel where the science instruments are kept at Earth-like temperature and pressure (25 deg C and 1 atm). The purpose of this project was to develop and demonstrate a method for sample transfer from an external drill to internal science instruments for a lander on Venus. The initial concepts were string and pneumatically driven systems; and the latter system was selected for its ability to deliver samples at very high speed. The pneumatic system was conceived to be driven by the pressure difference between the Venusian atmosphere and the inside of the lander. The pneumatic transfer of a small capsule was demonstrated, and velocity data was collected from the lab experiment. The sample transfer system was modeled using CAD software and prototyped using 3D printing. General structural and thermal analyses were performed to approximate the proposed system's mass and effects on the temperature and pressure inside of the lander. Additionally, a sampler breadboard for use on Titan was tested and functionality problems were resolved.

sample handling↗

On‐Demand Ambient Ionization of Picoliter Samples Using Charge Pulses

Abstract Relay electrospray ionization (rESI) from a capillary containing a sample solution (or from an array of such capillaries) is triggered by charge deposition onto the capillary. Suitable sources of primary ions, besides electrosprays, are plasma ion and piezoelectric discharge plasma sources. With no requirement for physical contact, high‐throughput sample screening is enabled by rapidly addressing individual secondary (sample) capillaries. Sub‐pL sample volumes can be loaded and sprayed. Polar analytes, including neurotransmitters, phosphopeptides, oligonucleotides, illicit drugs, and pharmaceutical compounds are successfully ionized by rESI with concentration sensitivities (0.1 ppb for acetylcholine) which are similar to nanoESI but absolute sensitivities are orders of magnitude better. Nonpolar analytes (steroids, alkynes) are ionized by rESI using an open‐tube secondary capillary and injecting electrolytically generated metal cations from the primary electrospray.

Li, Anyin↗

On‐Demand Ambient Ionization of Picoliter Samples Using Charge Pulses

Abstract Relay electrospray ionization (rESI) from a capillary containing a sample solution (or from an array of such capillaries) is triggered by charge deposition onto the capillary. Suitable sources of primary ions, besides electrosprays, are plasma ion and piezoelectric discharge plasma sources. With no requirement for physical contact, high‐throughput sample screening is enabled by rapidly addressing individual secondary (sample) capillaries. Sub‐pL sample volumes can be loaded and sprayed. Polar analytes, including neurotransmitters, phosphopeptides, oligonucleotides, illicit drugs, and pharmaceutical compounds are successfully ionized by rESI with concentration sensitivities (0.1 ppb for acetylcholine) which are similar to nanoESI but absolute sensitivities are orders of magnitude better. Nonpolar analytes (steroids, alkynes) are ionized by rESI using an open‐tube secondary capillary and injecting electrolytically generated metal cations from the primary electrospray.

Li, Anyin↗

Effect of Sample Mass, Confinement, and Preheating Time on the Thermal Response of LLM‐105: Experiments and Kinetic Analysis

Various small-scale experiments were performed to provide data for developing a model to predict the thermal response of LLM-105 over a wide range of conditions. The thermal decomposition of LLM-105 was studied as a function of sample mass, confinement of volatile products, and preheating time in both isothermal and ramped heating experiments. The thermal decomposition of LLM-105 is a two-step process, as shown by the two exothermic peaks in the heat flow profiles, which were fitted to two nth-order autocatalytic reaction models with a similar activation energy of ∼289 kJ/mol. The magnitude and shape of these peaks varied with sample mass and confinement. Increasing sample mass enhanced the second exotherm with respect to the first one, while increasing the level of confinement promoted a transition from a sublimation-dominated regime towards thermal decomposition. The effect of LLM-105 particle size on the rate of weight loss was evident for open-pan experiments, where bigger particles sublimed at lower temperatures than smaller particles. Thermal response and solid residue composition of LLM-105 samples were analyzed following preheating for different durations. Longer preheating times caused a shift of the second exotherm to lower temperatures and a decrease in the reaction enthalpy, confirming that LLM-105 decay is a consecutive reaction mechanism, probably autocatalytic. In conclusion, the kinetic model derived from ramped experiments was validated against the measured LLM-105 fraction remaining and the enthalpy remaining of the solid residue as a function of preheating times and showed good agreement.

Chemistry - Chemical explosives↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Image Reconstruction from Under sampled Fourier Data Using the Polynomial Annihilation Transform

Fourier samples are collected in a variety of applications including magnetic resonance imaging and synthetic aperture radar. The data are typically under-sampled and noisy. In recent years, l 1 regularization has received considerable attention in designing image reconstruction algorithms from under-sampled and noisy Fourier data. The underlying image is assumed to have some sparsity features, that is, some measurable features of the image have sparse representation. The reconstruction algorithm is typically designed to solve a convex optimization problem, which consists of a fidelity term penalized by one or more l 1 regularization terms. The Split Bregman Algorithm provides a fast explicit solution for the case when TV is used for the l1l1 regularization terms. Due to its numerical efficiency, it has been widely adopted for a variety of applications. A well known drawback in using TV as an l 1 regularization term is that the reconstructed image will tend to default to a piecewise constant image. This issue has been addressed in several ways. Recently, the polynomial annihilation edge detection method was used to generate a higher order sparsifying transform, and was coined the “polynomial annihilation (PA) transform.” This paper adapts the Split Bregman Algorithm for the case when the PA transform is used as the l 1 regularization term. In so doing, we achieve a more accurate image reconstruction method from under-sampled and noisy Fourier data. Our new method compares favorably to the TV Split Bregman Algorithm, as well as to the popular TGV combined with shearlet approach.

97 MATHEMATICS AND COMPUTING↗

Synthesis and Characterization of Er-Doped Nano ZnO Samples

Pure and erbium-doped ZnO nanoparticles (Zn{sub 1−x}Er{sub x}O), (0.00 ≤ x ≤ 0.10), were synthesized by wet chemical co-precipitation method. The structural, optical, and magnetic properties of the prepared samples were investigated using x-ray powder diffraction (XRD), transmission electron microscopy (TEM), ultraviolet-visible spectroscopy (UV), Fourier transform infrared spectroscopy (FTIR), M-H magnetic hysteresis, and electron paramagnetic resonance (EPR). XRD studies exhibit the presence of a single ZnO wurtzite hexagonal crystal structure for 0.00 ≤ x ≤ 0.06. A secondary phase of Er{sub 2}O{sub 3} appears for x > 0.06. This means that the solubility limit for doping Zn{sup 2+} ions by Er{sup 3+} ions is about x = 0.06 under our preparations condition. The lattice parameter a is not affected by the Erbium doping. On the other hand, the lattice parameter c and the unit cell volume V increase with the increase of x up to x = 0.06. This is attributed to the larger ionic size of Er{sup 3+} ions (0.88 Å) compared to Zn{sup 2+} ions (0.74 Å). Both c and V decrease for x > 0.06. TEM micrographs indicate that the shape and the size of the ZnO nanoparticles are modified by changing the doping level of Er. The UV measurements point out that band gap energy E{sub g} decreases with the increase of x up to x = 0.06. Then, it increases for both x = 0.08 and 0.10. FTIR spectra confirm the presence of O–H and Zn–O stretching modes at 3451.963 and 428.901 cm{sup − 1}, respectively, in pure and doped ZnO samples. The Zn–O stretching mode shifts toward a lower wavenumber for x = 0.06 and toward a higher wavenumber for x = 0.10. M-H hysteresis analysis, at room temperature, reveals that the pure ZnO has a ferromagnetic signal combined with diamagnetic and paramagnetic contributions. This ferromagnetism is reduced for the doped samples up to x = 0.02, and an antiferromagnetic alignment appears for 0.04 ≤ x ≤ 0.10. The saturation magnetization (M{sub s}), the coercivity (H{sub c}), the retentivity (M{sub r}), the anisotropy constant (K{sub a}), and the magnetic moment (μ{sub m}) were estimated and discussed in terms of erbium doping for the different samples. EPR spectra for Zn{sub 1−x}Er{sub x}O were measured at room temperature in order to study the effect of Er substitution on the g value, resonance field (H{sub r}), peak to peak line width (ΔH{sub pp}) and spin–spin relaxation time constant (T{sub 2}).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

A new method that rapidly preconcentrates and measures 226 Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226 Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226 Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226 Ra sample preparation takes < 2 hours.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid method to determine 89 Sr/ 90 Sr in large concrete samples

Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90 Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g -1 . The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90 Sr from 5-10 g concrete samples. When, the 89 Sr/ 90 Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90 Sr measured, and then 90Sr determined via 90 Y separated after a period of ingrowth. Another approach allows the immediate determination of 90 Sr in 10 g concrete aliquots without waiting for 90 Y ingrowth, in instances where the shorter lived 89 Sr is unlikely to be encountered.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

A Feature-Based Stochastic Permeability of Shale: Part 1—Validation and Two-Phase Permeability in a Utica Shale Sample

Estimate of permeability plays a crucial role in flow-based studies of fractured tight-rocks. It is well known that most of the flow through tight-rocks (e.g., shales) is controlled by permeable features (e.g., fractures, laminations, etc.), and there is negligible flow through the matrix. However, current approaches in the literature to model permeability of tight-rocks do not account for such features present within the rock ranging from micro-scale to field-scale. Current permeability modeling approach assumes a single continuum without considering the presence of permeable features within the matrix (e.g., micro-fractures) or outside the matrix (e.g., natural fractures). Although the laboratory-measured permeability implicitly captures discrete features present in that sample (e.g., fractures, laminations, micro-fractures), most of the permeability models proposed for shale do not account for these features. Fracture permeability in the literature is typically modeled using an ideal slit assumption; however, this highly overestimates its permeability because fractures in real medium are non-ideal in terms of their porosity and tortuosity, which affect their permeability. Additionally, the transition zone between fracture and matrix also affects the permeability of fracture. Here in this study, part of a two-part series, a new method to predict permeability of fractured shale by discretizing the medium into matrix (inorganic and organic) and fractures is presented. New analytical expressions of permeability are derived to account for non-ideal nature of porous medium and two-phase flow in fractures. Rock feature in each cell of the grid is identified as one of the three elements (organic matter, inorganic matter, or fracture), and permeability of that cell is estimated using a suitable analytical expression. This method allows estimating permeability at any scale of interest and more robustly than by a pure analytical approach. The proposed method is validated against local and global-scale measurements on three fractured samples from laboratory. Finally, the method is used to predict two-phase flow permeability of supercritical CO 2 displacing water within a fracture in a Utica shale sample. The proposed two-phase flow permeability equations can be used as a quick analytical tool to predict relative permeability estimates of two-phase flow in fractured shale samples. In Part 2, the proposed method is used to estimate field-scale permeability through an optimization process that uses field-scale production and other readily available information.

58 GEOSCIENCES↗

Effects of Coatings on the High-Cycle Fatigue Life of Threaded Steel Samples

In this work, high-cycle fatigue is studied for threaded cylindrical high-strength steel samples coated using three different industrial processes: black oxidation, normal-temperature galvanization and high-temperature galvanization. The fatigue performance in air is compared with that of uncoated samples. Microstructural characterization revealed the abundant presence of small cracks in the zinc coating partially penetrating into the steel. This is consistent with the observation of multiple crack initiation sites along the thread in the galvanized samples, which led to crescent type fracture surfaces governed by circumferential growth. In contrast, the black oxidized and uncoated samples exhibited a semicircular segment type fracture surface governed by single-sided growth with a significantly longer fatigue life. Numerical fatigue life prediction based on an extended Paris-law formulation has been conducted on two different fracture cases: 2D axisymmetric multisided crack growth and 3D single-sided crack growth. The results of this upper-bound and lower-bound approach are in good agreement with experimental data and can potentially be used to predict the lifetime of bolted components.

36 MATERIALS SCIENCE↗

Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source

A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O – 3H]{sup +} was observed in the case of individual alkanes (C{sub 5}–C{sub 19}) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sample-based synthesis of two-scale structures with anisotropy

A vast majority of natural or synthetic materials are characterized by their anisotropic properties, such as stiffness. Such anisotropy is effected by the spatial distribution of the fine-scale structure and/or anisotropy of the constituent phases at a finer scale. In design, proper control of the anisotropy may greatly enhance the efficiency and performance of synthesized structures. In this paper, we propose a sample-based two-scale structure synthesis approach that explicitly controls anisotropic effective material properties of the structure on the coarse scale by orienting sampled material neighborhoods at the fine scale. We first characterize the non-uniform orientations distribution of the sample structure by showing that the principal axes of an orthotropic material may be determined by the eigenvalue decomposition of its effective stiffness tensor. Such effective stiffness tensors can be efficiently estimated based on the two-point correlation functions of the fine-scale structures. Then we synthesize the two-scale structure by rotating fine-scale structures from the sample to follow a given target orientation field. Finally, the effectiveness of the proposed approach is demonstrated through examples in both 2D and 3D.

42 ENGINEERING↗

Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites was studied. Major organs (brain, lung, liver, kidney, muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. Furthermore, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.

59 BASIC BIOLOGICAL SCIENCES↗

2D-imaging of sampling-probe perturbations in laminar premixed flames using Kr X-ray fluorescence

The perturbation of the temperature field caused by a quartz sampling probe has been investigated in a fuel-rich low-pressure premixed ethylene/oxygen/argon/krypton flame using X-ray fluorescence. The experiments were performed at the 7-BM beamline at the Advanced Photon Source (APS) at the Argonne National Laboratory where a continuous beam of X-rays at 15 keV was used to excite krypton atoms that were added to the unburnt flame gases in a concentration of 5% (by volume). The resulting krypton X-ray fluorescence at 12.65 keV was collected and the spatially resolved signal was subsequently converted into the local temperature of the imaged spot. One and two dimensional scans of the temperature field were obtained by translating the entire flame chamber through a pre-programmed sequence of positions on high precision translation stages and measuring the X-ray fluorescence at each location. Multiple measurements were performed at various separations between the burner surface and probe tip, representing sampling positions from the preheat, reaction, and postflame zones of the low-pressure flame. Distortions of up to 1000 K of the burner-probe centerline flame temperature were found with the tip of the probe in the preheat zone and distortions of up to 500 K were observed with it in the reaction and postflame zones. Furthermore, perturbations of the temperature field have been revealed that radially reach as far as 20 mm from the burner-probe centerline and about 3 mm in front of the probe tip. Finally, these results clearly reveal the limitations of one-dimensional models for predicting flame-sampling experiments and comments are made with regard to model developments and validations based on quantitative speciation data from low-pressure flames obtained via intrusive sampling techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of sample size on the maximum value distribution of fatigue driving forces in metals and alloys

An analytical framework is presented to predict the effects of sample size on the maximum value distribution (MVD) of the driving forces for fatigue crack formation in metals and alloys. The distribution of the maximum driving force for fatigue crack formation over the domain follows the generalized extreme value theory in the limit as the domain size increases to infinity. Here, a simulation-based analysis of microstructure influences on fatigue resistance for polycrystalline metals and alloys is very costly, and reaching those limits is intractable. This work models the MVD of Fatigue Indicator Parameters (FIPs), which serve as surrogate measures for the driving force for fatigue crack formation, at finite sample sizes prior to their convergence to a limiting extreme value distribution. Large-scale crystal plasticity finite element (CPFE) simulations of FCC Al 7075-T6 with microstructure realizations of various sizes are incorporated to calibrate and evaluate the developed framework, and a total of ∼6.5 million grains of Al 7075-T6 are examined. The calibrated analytical solution agrees well with the brute force Monte Carlo simulation results extracted from the CPFE simulations. Furthermore, the developed formulation can predict the MVD of FIPs for different sample sizes using a size-dependent parameter, and it is capable of accurately extrapolating the MVD of FIPs for much larger microstructure sample sizes than the size used for its calibration.

Crystal plasticity↗

Measured CO 2 sorption isotherms with 25 Bakken Petroleum System rock samples from the Lower and Upper Shales, Middle Bakken, and Three Forks formations

Isotherms were measured with 25 Bakken Petroleum System (BPS) rock samples using a magnetic suspension balance at reservoir conditions of 110 °C and pressures up to 345 bar. Samples from four wells represented the Middle Bakken (MB) and Three Forks (TF) production zones, and the Upper Bakken Shale (UBS) and Lower Bakken Shale (LBS) source shales. UBS and LBS CO 2 sorption capacities at 345 bar averaged 12–14 g/kg rock compared to 1.3 to 2.5 g/kg rock for MB and TF. Increasing pressure from 150 to 345 bar resulted in only small increases in CO 2 sorption for all lithofacies. For the UBS and LBS source shales, the higher average total organic carbon (TOC) values (14.7 and 11.4 wt.%) and clay values (25 and 28 wt.%) corresponded to their higher CO 2 sorption values while for the MB and TF samples, lower TOCs (0.3 and 0.5 wt.%) and clay values (8.2 and 18.2 wt.%) corresponded to lower CO 2 sorption values. Here, when all 25 samples (from all lithofacies) were evaluated as a group, sorption capacities were highly correlated with TOC (Spearman's rho values +0.84 to +0.85), with rock density (rho values -0.75 to -0.76), and clay content (rho values +0.66). However, correlations with porosity and thermal maturity (Tmax) were weak. Measured sorption capacities and rock porosities showed that sorption accounted for about 10-times as much CO 2 storage as the available pore space for the UBS and LBS lithofacies. In contrast, the pore space dominated the storage resource of the TF and MB lithofacies.

54 ENVIRONMENTAL SCIENCES↗