Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SERVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Assessment of grid-friendly collective optimization framework for distributed energy resources

Distributed energy resources have the potential to provide services to facilities and buildings at lower cost and environmental impact in comparison to traditional electric-gridonly services. The reduced cost could result from a combination of higher system efficiency and exploitation of electricity tariff structures. Traditionally, electricity tariffs are designed to encourage the use of ‘off peak’ power and discourage the use of ‘onpeak’ power, although recent developments in renewable energy resources and distributed generation systems (such as their increasing levels of penetration and their increased controllability) are resulting in pressures to adopt tariffs of increasing complexity. Independently of the tariff structure, more or less sophisticated methods exist that allow distributed energy resources to take advantage of such tariffs, ranging from simple pre-planned schedules to Software-as-a-Service schedule optimization tools. However, as the penetration of distributed energy resources increases, there is an increasing chance of a ‘tragedy of the commons’ mechanism taking place, where taking advantage of tariffs for local benefit can ultimately result in degradation of service and higher energy costs for all. In this work, we use a scheduling optimization tool, in combination with a power distribution system simulator, to investigate techniques that could mitigate the deleterious effect of ‘selfish’ optimization, so that the high-penetration use of distributed energy resources to reduce operating costs remains advantageous while the quality of service and overall energy cost to the community is not affected.

Pensini, Alessandro↗

Fast DR: Controlling Small Loads over the Internet

Current state-of-the-art demand response systems are expensive due to extreme reliability constraints in telemetry, control, and metering. The typical cost of enabling a site for regulation services is between $50k and $80k. These costs are orders of magnitude too high for small loads to participate in high-value grid services. Traditional demand response (DR) schedules events in advance and provides basic on/off control. We developed fast DR measurement and communication technologies, which are scalable cost-effective demand response systems with sufficient reliability for real-time control and monitoring of loads over the internet, and we demonstrated an example system for under $100. We installed FastDR systems for lighting, motor, and thermostat control along with power metering at a total of 10 sites, including 6 commercial buildings and 4 residential buildings. This demonstration addressed the following important methodological questions: 1) Can we reliably control loads simultaneously and with low latency across multiple sites within a specified response time; 2) How reliable is using the internet or 4G cellular network as the mode of control and metering; and 3) Can existing Smart Meters provide data for real-time telemetry services. Testing shows fast DR is capable of control to response in 4 seconds and loads complete transition in seconds to less than one minute depending on load type. We demonstrated 4s regulation services and synchronized load control, and we successfully met specifications for ancillary services across the US. Telemetry via the 4G cellular network demonstrated 94.5% success rate, and residential Internet demonstrated a 98% success rate.

Kiliccote, Sila↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Long term performance of vacuum insulation panels integrated into building components

Vacuum insulation panels provide much greater resistance to heat transfer than conventional insulation materials, making them ideal for building applications, especially where space is a constraint. Of particular interest is energy retrofits where high insulation values are required with very little or no modifications to existing building envelope elements such as fenestrations and service penetrations. To facilitate the use of vacuum insulation panels (VIPs) in residential and commercial construction, this study investigates the performance of VIPs integrated into polyisocyanurate foam board and vinyl siding after several years of service. Vacuum insulation panels integrated with polyisocyanurate boards were studied in mixed humid and cold climates. The integration of VIPs with vinyl siding was investigated in a mixed humid climate. Periods of service were between two and five years. In all cases, the integrated building components outperformed conventional materials by almost 40 percent during heating and cooling periods. However, the percent reduction in heat gains and losses of the integrated building components decreased with time at a rate between approximately 4% and 10% per year during the service period. In some cases, the rate seems to converge to a steady -state value. Measurements are ongoing to determine if a steady-state value is attained or the panel's insulation value continues to decrease with time. This study is critical in addressing the service life and durability of the building envelope with VIP integrated building components. The effect of these changes will be reviewed in the context of an exterior retrofit.

Aldykiewicz Jr, Antonio↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation and the results have proved the effectiveness of this method.

AMI↗

Commercialization of a DOE Laboratory

On April 1, 1998, Materials and Chemistry Laboratory, Inc. (MCLinc) began business as an employee-owned, commercial, applied research laboratory offering services to both government and commercial clients. The laboratory had previously been a support laboratory to DoE's gaseous diffusion plant in Oak Ridge (K-25). When uranium enrichment was halted at the site, the laboratory was expanded to as an environmental demonstration center and served from 1992 until 1997 as a DOE Environmental User Facility. In 1997, after the laboratory was declared surplus, it was made available to the employee group who operated the laboratory for DOE as a government-owned, contractor-operated facility. This paper describes briefly the process of establishing the business. Attributes that contributed to the success of MCLinc are described. Some attention is given to lessons learned and to changes that could facilitate future attempts to make similar transitions. Lessons learnt: as with any business venture, operation over time has revealed that some actions taken by the laboratory founders have contributed to its successful operation while others were not so successful. Observations are offered in hopes that lessons learned may suggest actions that will facilitate future attempts to make similar transitions. First, the decision to vest significant ownership of the business in the core group of professionals operating the business is key to its success. Employee-owners of the laboratory have consistently provided a high level of service to its customers while conducting business in a cost-efficient manner. Secondly, an early decision to provide business support services in-house rather than purchasing them from support contractors on site have proven cost-effective. Laboratory employees do multiple tasks and perform overhead tasks in addition to their chargeable technical responsibilities. Thirdly, assessment of technical capabilities in view of market needs and a decision to offer these capabilities as a niche market play to success. The niche was further defined by preservation of the ability to handle samples contaminated with radiological materials and those with classification concerns. These decisions enabled early marketing plans to be built on existing clientele and provided an identifiable group to which future marketing could be expanded. Finally, recruitment of key players with commercial laboratory experience proved to be a key factor for success. This experience base was valuable in avoiding early mistakes in the laboratory startup phase and provided some connection to a commercial client base. As the business has grown, professionals with commercial laboratory experience have been recruited and offered ownership in the business as an incentive for joining the group. If the process were to be repeated, early involvement of an individual with commercial sales experience would be helpful in broadening the base of commercial clients. An increased emphasis on research funding such as funding received from Small Business Innovative Research (SBIR) sources would be used to form a portion of the economic base for the business. More partnerships with businesses whose services compliment those of the laboratory would expand available client base. More flexible staffing arrangements would be negotiated early on as a cost-control measure. In conclusion, the re-industrialization concept can be successful. Candidates for re-industrialization must be chosen by matching services to be offered to market needs. Implementation is best accomplished by entrepreneurs who personally profit from a successful operation of the business.

99 GENERAL AND MISCELLANEOUS↗

Safe and Effective Deactivation of Metallic Sodium Filled Scrap and Cold Traps From Sodium-cooled Nuclear Reactor D and D - 12176

As part of the Plateau Remediation Project at US Department of Energy's Hanford, Washington site, CH2M Hill Plateau Remediation Company (CHPRC) contracted with IMPACT Services, LLC to receive and deactivate approximately 28 cubic meters of sodium metal contaminated debris from two sodium-cooled research reactors (Enrico Fermi Unit 1 and the Fast Flux Test Facility) which had been stored at Hanford for over 25 years. CHPRC found an off-site team composed of IMPACT Services and Commodore Advanced Sciences, Inc., with the facilities and technological capabilities to safely and effectively perform deactivation of this sodium metal contaminated debris. IMPACT Services provided the licensed fixed facility and the logistical support required to receive, store, and manage the waste materials before treatment, and the characterization, manifesting, and return shipping of the cleaned material after treatment. They also provided a recycle outlet for the liquid sodium hydroxide byproduct resulting from removal of the sodium from reactor parts. Commodore Advanced Sciences, Inc. mobilized their patented AMANDA unit to the IMPACT Services site and operated the unit to perform the sodium removal process. Approximately 816 Kg of metallic sodium were removed and converted to sodium hydroxide, and the project was accomplished in 107 days, from receipt of the first shipment at the IMPACT Services facility to the last outgoing shipment of deactivated scrap metal. There were no safety incidents of any kind during the performance of this project. The AMANDA process has been demonstrated in this project to be both safe and effective for deactivation of sodium and NaK. It has also been used in other venues to treat other highly reactive alkali metals, such as lithium (Li), potassium (K), NaK and Cesium (Cs). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benefits of a Full Waste Cost Recovery Program - 16322

A full waste cost recovery program has been established at the INL in order to fund disposition of all newly-generated hazardous, radioactive, and mixed waste at the INL. Significant improvements have resulted from implementation of this program at the INL, and it is anticipated that others could benefit from using a similar approach. The INL Waste Management Program (WMP) administers two site-wide service centers that collect revenue from programs and projects in order to pay waste disposition costs. These service centers are administered separately due to their unique scope and functions. The combination of these service centers provides the INL with a fully functional cost recovery program for all newly generated waste. This cost recovery program ensures that funding is available for disposition of all waste types and that waste costs are paid for by the generating programs or facilities. The implementation of these service centers in Fiscal Year 2014 has resulting in several significant improvements in waste disposition, including a substantial increase in awareness and emphasis on waste minimization and segregation. The service centers have virtually eliminated funding shortfalls from projects that end and have not budgeted for dispositioning waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Results from the High Fluence UCSB ATR-2 Irradiation

A primary focus of the Department of Energy, Office of Nuclear Energy Light Water Reactor Sustainability Program (LWRSP) is the safe operation of nuclear reactors to extended lifetimes of up to 80 years. One of the primary reactor components of concern is the reactor pressure vessel (RPV), which is increasingly embrittled over time due to damage from high energy neutrons created in the reactor core. Radiation damage leads to the formation of nm-scale precipitates and solute-defect clusters, which result in an increase in the steel's ductile to brittle transition temperature. Transition temperature shifts (TTS) are used to quantify and regulate embrittlement. Extended life operation will subject some RPVs to higher neutron fluences than previously experienced by in-service vessels. Thus, robust prediction methods must be developed that ensure the safety of our nation's fleet of reactors. Current models underpredict embrittlement data from high flux test reactor irradiations at extended life fluences. It has been hypothesized that one reason for this underprediction is the formation of so-called 'Late- Blooming Phase' Mn-Ni-Si precipitates, which form and grow only at high fluence and that are currently not included in regulatory models. Recent research has demonstrated the existence of high volume fractions of intermetallic Mn-Ni-Si precipitate (MNSP) phases at high fluence and have generated significant insight into their character. However, a number of questions remain regarding MNSPs, such as: 1) what alloys are most susceptible to MNSP formation; 2) how is MNSP formation affected by flux (φ), fluence (φt) and irradiation temperature (T{sub irr}); and, 3) how to accurately predict TTS under extended life low flux service conditions? The fact that no two RPVs are exactly the same, both in terms of the steel composition and vessel service conditions, makes these questions particularly difficult to answer. Further, understanding the effect of flux differences between test reactor irradiations and in-vessel service is absolutely critical. Hence, physical models must be developed that predict TTS as a function of alloy solute content and vessel service conditions. A large-scale irradiation designed to develop and validate an extended life embrittlement prediction model was recently completed in the Advanced Test Reactor (ATR) at the Idaho National Laboratory as part of the DOE sponsored Nuclear Scientific User Facilities. This experiment, called the UCSB ATR-2 irradiation, is a collaboration between Oak Ridge National Lab (ORNL) and the University of California, Santa Barbara (UCSB) and is now primarily supported by the DOE Light Water Reactor Sustainability Program. The experiment is designed to investigate the single and combined effects of neutron φ, φt, T{sub irr} and alloy chemistry on precipitate formation, hardening and embrittlement. While postirradiation examinations (PIE) is ongoing, and is expected to take several years to complete, the first preliminary results are presented below. It should also be noted that Rolls-Royce has been a collaborator in UCSB ATR-2 from the start, and there are several other national and international institutions supporting the PIE. (authors)

36 MATERIALS SCIENCE↗

Oxide Growth and Validation for Aluminum Research Reactor Fuel - 19422

Aluminum fuel cladding will undergo general corrosion with resulting formation of adherent oxide films during in-reactor and post-discharge exposures under various water conditions and temperatures. These oxides include chemically-bound water that can pose challenges for extended dry storage. This paper describes laboratory experiments performed to produce hydroxide (oxide) films on aluminum 1100, 6061 and 5052 series alloy substrates immersed in water at controlled temperatures. The results are compared to the oxide film present on a spent fuel assembly irradiated in research reactor. This work is part of a broad investigation to address knowledge gaps and technical data needs for dry storage of aluminum-clad spent nuclear fuel (SNF). To adequately assess the risks posed by chemically-bound water on SNF in dry storage and strategies for removing chemically bound water, it is necessary to understand the expected composition and loading of oxide films on SNF of different service histories and to investigate the response of such oxides to irradiation and potential drying methods. These efforts require both the growth of films under controlled conditions and the production of non-radioactive surrogates for testing. The current work comprises experimental investigation of oxide growth via (1) laboratory experiments to produce hydroxide films on aluminum alloy substrates immersed in water at controlled temperatures and (2) characterization and comparison of laboratory-grown oxides to oxides on service-exposed aluminum alloys. The important factors affecting oxide growth and characteristics typical of oxide films formed by aqueous corrosion under conditions similar to in-reactor are reviewed. Aluminum oxide films were grown under a variety of controlled temperature conditions and durations to serve as surrogates for oxides found on aluminum-clad spent nuclear fuel due to aqueous corrosion. The chemically-bound water found in oxides formed by aqueous corrosion poses challenges for extended dry storage, requiring investigation of how the oxide loading and characteristics vary with exposure history and to provide the initial condition for investigation of drying methods. Characteristics including chemical composition, oxide morphology, and film thickness were measured to assess whether the surrogate films were representative of in-service-produced oxides on SNF. Tests were conducted in liquid water at atmospheric pressure in the temperature range 50-100 deg. C, with and without heat flux through the corroding surface, to replicate in-service conditions, and at 185 deg. C inside pressure vessels to replicate pre-filming procedures. Three different alloys commonly used in aluminum clad research reactor fuel were considered: Al-1100, Al-6061, and Al-5052. Specimens were characterized by weighing before and after exposure to measure oxide mass loading, X-ray diffraction to identify oxide composition, and scanning electron microscopy to examine the oxide morphology and film thickness. The oxide type and the morphological characteristics of the film on a fuel element from the Uruguay RU1 research reactor were determined and compared to the laboratory surrogates. The results show some differences compared to the 50 deg. C laboratory specimen that are rationalized with the service storage history of the element. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Digital-Threat Bias and Psychological Distance: Barriers to Foundational Digital-Security Improvement

Modern life is held together by a web of digital dependencies that enable and provide delivery of critical services and functions—think the provision of utilities such as electricity and water, as well as our dependency on digital services for social and economic services (internet, communication, etc.). As this dependency grows, the complexity related to the delivery of these critical services increases as well. As complexity increases, the understanding of the risk and impact associated with potential disruption, degradation, or destruction—due to either malicious or non-malicious events of those digitally enabled functions—decreases. One potential explanation for the difficulty to 1) understand the risks faced and 2) address them appropriately and effectively is the abstractness and psychological distance assigned to “digital threat.” The complexity of these digitally enabled services creates a perceived complicatedness; as a result, digital threats are treated differently than similarly devasting (but more easily understood) kinetic or physical threats. How we categorize these threats also matters. Acts of cyber-enabled sabotage to critical infrastructure need to be defined as irregular warfare. By inadequately defining the threat, we compound the problem. Acknowledging this digital-threat bias is foundational to improving the ability to protect critical infrastructure. Using construal-level theory and psychological-distance concepts provides an intriguing starting point to address these issues, to reframe the challenges faced, and pursue more effective critical infrastructure security and defense policy.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Positive water linkages of producing short rotation poplars and willows for bioenergy and phytotechnologies

The production of short rotation woody crops (SRWCs) such as poplars and willows is a promising component of global bioenergy and phytotechnology portfolios. In addition to the provision of biomass feedstocks and pollution remediation, these trees and shrubs have been sustainably grown to conserve or utilize water in a variety of applications. Growing these woody plants for multiple uses supports many of the United Nation's Sustainable Development Goals (SDGs), especially Clean Water and Sanitation (SDG6) and Affordable and Clean Energy (SDG7). As a result, focusing on ecosystem services such as freshwater and biomass has become an important aspect of deploying these production systems across variable landscapes. The current review consists of an introduction of ecosystem services and the SDGs, as well as SRWCs and their applications. The middle section of the review contains case studies highlighting the positive water linkages of producing short rotation poplars and willows for bioenergy and phytotechnologies. The review concludes with a section that combines the common themes that are consistent among the case studies to address options for integrating new bioenergy feedstock production systems into rural and urban landscapes to promote environmental, social and economic sustainability. This article is categorized under: Bioenergy > Economics and Policy Bioenergy > Climate and Environment

biomass production↗

Examining the Potential for Agricultural Benefits from Pollinator Habitat at Solar Facilities in the United States

Of the many roles insects serve for ecosystem function, plant pollination is possibly the most important service directly linked to human well-being. However, global land uses have contributed to the decline of pollinators and their habitats. In agricultural landscapes that also support renewable energy developments (such as utility-scale solar energy [USSE] facilities), opportunities may exist to conserve insect pollinators and locally restore their ecosystem services through the implementation of vegetation management approaches that aim to provide and maintain pollinator habitat at USSE facilities. As a first step towards understanding the potential agricultural benefits of solar-pollinator habitat, we identified areas of overlap between USSE facilities in the United States and surrounding pollinator-dependent crop types. We identified over 3,500 km2 of agricultural land near existing and planned USSE facilities that may benefit from increased pollination services through the creation of pollinator habitat at the USSE facilities. The following five pollinator-dependent crop types accounted for over 90% of the agriculture near USSE facilities, and these could benefit most from the creation of pollinator habitat at existing and planned USSE facilities: soybeans, alfalfa, cotton, almonds, and citrus. We discuss how our results may be used to understand potential agro-economic implications of solar-pollinator habitat. Our results show that ecosystem service restoration through the creation of pollinator habitat could improve the compatibility of large-scale renewable energy developments in agricultural landscapes.

Agriculture↗

Adaptive primal–dual control for distributed energy resource management

With the increased adoption of distributed energy resources (DERs) in distribution networks, their coordinated control with a DER management system (DERMS) that provides grid services (e.g., voltage regulation, virtual power plant) is becoming more necessary. One particular type of DERMS using primal–dual control has recently been found to be very effective at providing multiple grid services among an aggregation of DERs; however, the main parameter, the primal–dual step size, must be manually tuned for the DERMS to be effective, which can take a considerable amount of engineering time and labor. To this end, we design a simple method that self-tunes the step size(s) and adapts it to changing system conditions. Additionally, it gives the DER management operator the ability to prioritize among possibly competing grid services. Here we evaluate the automatic tuning method on a simulation model of a real-world feeder in Colorado with data obtained from an electric utility. Through a variety of scenarios, we demonstrate that the DERMS with automatically and adaptively tuned step sizes provides higher-quality grid services than a DERMS with a manually tuned step size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmental effect of structural solutions and building materials to a building

The field of building environmental assessment tools has become a popular research area over the past decade. However, how the service life of a building affects the results of the environmental assessment of a building has not been emphasised previously. The aim of this study is to analyse how different structural solutions and building materials affect the results of the environmental assessment of a whole building over the building's life cycle. Furthermore, how the length of the building's service life affects the results is analysed. The environmental assessments of 78 single-family houses were calculated for this study. The buildings have different wall insulations, claddings, window frames, and roof materials, and the length of the service life varies from 60 years up to 160 years. The current situation and the future of the environmental assessment of buildings are discussed. In addition, topics for further research are suggested; for example, how workmanship affects the service life and the environmental impact of a building should be studied.

54 ENVIRONMENTAL SCIENCES↗

Influence of restored mussel reefs on denitrification in marine sediments

Globally we have lost the majority of shellfish reefs, with the concomitant loss of ecosystem services. Restoration provides opportunities to regain lost services and engage society in the wider ecosystem benefits of restoration. Previous research has demonstrated that the functional role of shellfish can be context dependent, and we therefore measured fluxes of nutrients and dissolved gases from four restored mussel reefs along a grain size gradient in New Zealand as a metric of success in ecosystem function. This globally novel research found that restored mussel reefs were successful in enhancing denitrification. Mussel reefs can therefore be important in reducing the risk of future eutrophication, but the importance of nutrient remineralisation varies in response to site conditions. These data show that mussel reef creation can quickly restore ecosystem function, but site selection to enhance specific services is important. Furthermore, this study provides evidence of a poorly realised ecosystem service provided by restored mussel beds that allows future restoration efforts to better target areas in order to have the largest impact on the removal of anthropogenic nitrogen.

54 ENVIRONMENTAL SCIENCES↗

Aging behavior of polymeric solar absorber materials: Aging on the component level

Within this study, the aging behavior of a PPE + PS absorber material was investigated on the absorber component level. To indicate aging, characteristic mechanical values were determined by indentation tests of specimens taken from components and exposed to laboratory aging (140 C in air, 80 C in water) and service near outdoor aging conditions (stagnation in northern climate). In addition to the mechanical tests, the unaged and aged specimens were also characterized thermo-analytically via differential scanning calorimetry (DSC). The results indicate that reductions in both characteristic mechanical values of the indentation tests, i.e., load of the first transition and ultimate indentation, reflect at least some physical aging although chemical aging may also be of importance based on previous analytical investigations of laboratory aged polymer films. While laboratory aging in air at 140 C and service exposure at a test facility in Oslo (N) under stagnation conditions led to a significant reduction in the mechanical indentation resistance, no influence of laboratory aging in water at 80 C on the mechanical behavior of the absorber sheet was found. Depending on the ultimate failure criterion applied (reduction of characteristic mechanical values to 80% and 50%, respectively), the technical service life found for hot air laboratory and stagnation service conditions was found to be less than 51 and 159 h, respectively. As these durations are significantly below the estimated stagnation conditions accumulated in the desired operation lifetime for such a collector, the PPE + PS type investigated does not seem to be a proper material candidate for solar thermal absorbers. Finally, based on the results obtained, a relation between laboratory aging time in air at 140 C and cumulated irradiation energy during exposure on the test facility in Oslo was established. (author)

14 SOLAR ENERGY↗

Thermoelectric powered wireless sensors for spent fuel monitoring

This paper describes using thermoelectric generators to power wireless sensors to monitor spent nuclear fuel during dry-cask storage. OrigenArp was used to determine the decay heat of the spent fuel at different times during the service life of the dry-cask. The Engineering Equation Solver computer program modeled the temperatures inside the spent fuel storage facility during its service life. The temperature distribution in a thermoelectric generator and heat sink was calculated using the computer program Finite Element Heat Transfer. From these temperature distributions the power produced by the thermoelectric generator was determined as a function of the service life of the dry-cask. In addition, an estimation of the path loss experienced by the wireless signal can be made based on materials and thickness of the structure. Once the path loss is known, the transmission power and thermoelectric generator power requirements can be determined. This analysis estimates that a thermoelectric generator can produce enough power for a sensor to function and transmit data from inside the dry-cask throughout its service life. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗