Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Correlating whisker growth and grain structure on Sn-Cu samples by real-time scanning electron microscopy and backscattering diffraction characterization

Whiskers/hillocks grow out of Pb-free Sn coatings used in electronics manufacturing. To determine which grains form whiskers/hillocks, we use scanning electron microscopy and backscattering diffraction to simultaneously monitor the surface morphology and grain structure. To reduce surface roughness, we developed a ''peel-off'' method to prepare ultra-flat samples that were measured repeatedly while whiskers/hillocks formed. We find grains that form into whiskers/hillocks are present in the as-deposited film (i.e., not re-nucleated) and many have horizontal grain boundaries beneath them. Grain rotation during whisker/hillock formation means that measurements performed after the features grow do not indicate their initial grain orientations.

36 MATERIALS SCIENCE↗

Hard x-ray scanning microscopy with coherent radiation: Beyond the resolution of conventional x-ray microscopes

We demonstrate x-ray scanning coherent diffraction microscopy (ptychography) with 10 nm spatial resolution, clearly exceeding the resolution limits of conventional hard x-ray microscopy. The spatial resolution in a ptychogram is shown to depend on the shape (structure factor) of a feature and can vary for different features in the object. In addition, the resolution and contrast are shown to increase with increasing coherent fluence. For an optimal ptychographic x-ray microscope, this implies a source with highest possible brilliance and an x-ray optic with a large numerical aperture to generate the optimal probe beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular beam epitaxy of bilayer Bi(111) films on topological insulator Bi{sub 2}Te{sub 3}: A scanning tunneling microscopy study

We report on molecular beam epitaxy growth of bilayer Bi(111) films on topological insulator Bi{sub 2}Te{sub 3}. In situ scanning tunneling microscopy/spectroscopy shows that Bi growth mode changes from quasi bilayer-by-bilayer to step-flow with increasing substrate temperature. Bilayer Bi(111) exhibits an electron donor behavior, causing an 80 meV downshift of the Dirac point of Bi{sub 2}Te{sub 3}. Local work function difference between the bilayer films and Bi{sub 2}Te{sub 3} films is measured to be 390 meV. Based on the observations, we propose a schematic energy-band diagram which reveals band bending effect at the Bi/Bi{sub 2}Te{sub 3} interface. Our work paves a way to explore the exotic topological properties of bilayer islands and thin films of Bi.

36 MATERIALS SCIENCE↗

In situ investigation of ion-induced dewetting of a thin iron-oxide film on silicon by high resolution scanning electron microscopy

Using our new in situ high resolution scanning electron microscope, which is integrated into the UNILAC ion beamline at the Helmholtzzentrum fuer Schwerionenforschung (GSI) in Darmstadt, Germany, we investigated the swift heavy ion induced dewetting of a thin iron oxide layer on Si. Besides heterogeneous hole nucleation at defects and spontaneous (homogeneous) hole nucleation, we could clearly identify a dewetting mechanism, which is similar to the spinodal dewetting observed for liquid films. Instead of being due to capillary waves, it is based on a stress induced surface instability. The latter results in the formation of a wavy surface with constant dominant wave-length and increasing amplitude during ion irradiation. Dewetting sets in as soon as the wave-troughs reach the film-substrate interface. Inspection of the hole radii and rim shapes indicates that removal of the material from the hole area occurs mainly by plastic deformation at the inner boundary and ion induced viscous flow in the peripheral zone due to surface tension.

36 MATERIALS SCIENCE↗

End station for nanoscale magnetic materials study: Combination of scanning tunneling microscopy and soft X-ray magnetic circular dichroism spectroscopy

We have constructed an end station for nanoscale magnetic materials study at the soft X-ray beamline HiSOR BL-14 at Hiroshima Synchrotron Radiation Center. An ultrahigh-vacuum scanning tunneling microscope (STM) was installed for an in situ characterization of nanoscale magnetic materials in combination with soft X-ray magnetic circular dichroism (XMCD) spectroscopy experiment. The STM was connected to the XMCD experimental station via damper bellows to isolate it from environmental vibrations, thus achieving efficient spatial resolution for observing Si(111) surface at atomic resolution. We performed an in situ experiment with STM and XMCD spectroscopy on Co nanoclusters on an Au(111) surface and explored its practical application to investigate magnetic properties for well-characterized nanoscale magnetic materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of residual chips on the material removal process of the bulk metallic glass studied by in situ scratch testing inside the scanning electron microscope

Research on material removal mechanism is meaningful for precision and ultra-precision manufacturing. In this paper, a novel scratch device was proposed by integrating the parasitic motion principle linear actuator. The device has a compact structure and it can be installed on the stage of the scanning electron microscope (SEM) to carry out in situ scratch testing. Effect of residual chips on the material removal process of the bulk metallic glass (BMG) was studied by in situ scratch testing inside the SEM. The whole removal process of the BMG during the scratch was captured in real time. Formation and growth of lamellar chips on the rake face of the Cube-Corner indenter were observed dynamically. Experimental results indicate that when lots of chips are accumulated on the rake face of the indenter and obstruct forward flow of materials, materials will flow laterally and downward to find new location and direction for formation of new chips. Due to similar material removal processes, in situ scratch testing is potential to be a powerful research tool for studying material removal mechanism of single point diamond turning, single grit grinding, mechanical polishing and grating fabrication.

36 MATERIALS SCIENCE↗

Three-dimensional imaging of copper pillars using x-ray tomography within a scanning electron microscope: A simulation study based on synchrotron data

While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron radiation based cross-sectional scanning photoelectron microscopy and spectroscopy of n-ZnO:Al/p-GaN:Mg heterojunction

Al-doped ZnO (AZO) deposited by radio frequency co-sputtering is formed on epitaxial Mg-doped GaN template at room temperature to achieve n-AZO/p-GaN heterojunction. Alignment of AZO and GaN bands is investigated using synchrotron radiation based cross-sectional scanning photoelectron microscopy and spectroscopy on the nonpolar side-facet of a vertically c-axis aligned heterostructure. It shows type-II band configuration with valence band offset of 1.63 {+-} 0.1 eV and conduction band offset of 1.61 {+-} 0.1 eV, respectively. Rectification behavior is clearly observed, with a ratio of forward-to-reverse current up to six orders of magnitude when the bias is applied across the p-n junction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The study of in situ scanning tunnelling microscope characterization on GaN thin film grown by plasma assisted molecular beam epitaxy

The epitaxial growth of GaN by Plasma Assisted Molecular Beam Epitaxy was investigated by Scanning Tunnelling Microscope (STM). The GaN film was grown on initial GaN (0001) and monitored by in situ Reflection High Energy Electron Diffraction and STM during the growth. The STM characterization was carried out on different sub-films with increased thickness. The growth of GaN was achieved in 3D mode, and the hexagonal edge of GaN layers and growth gradient were observed. The final GaN was of Ga polarity and kept as (0001) orientation, without excess Ga adlayers or droplets formed on the surface.

36 MATERIALS SCIENCE↗

Elevated temperature, nano-mechanical testing in situ in the scanning electron microscope

A general nano-mechanical test platform capable of performing variable temperature and variable strain rate testing in situ in the scanning electron microscope is described. A variety of test geometries are possible in combination with focused ion beam machining or other fabrication techniques: indentation, micro-compression, cantilever bending, and scratch testing. The system is intrinsically displacement-controlled, which allows it to function directly as a micro-scale thermomechanical test frame. Stable, elevated temperature indentation/micro-compression requires the indenter tip and the sample to be in thermal equilibrium to prevent thermal displacement drift due to thermal expansion. This is achieved through independent heating and temperature monitoring of both the indenter tip and sample. Furthermore, the apex temperature of the indenter tip is calibrated, which allows it to act as a referenced surface temperature probe during contact. A full description of the system is provided, and the effects of indenter geometry and of radiation on imaging conditions are discussed. The stabilization time and temperature distribution throughout the system as a function of temperature is characterized. The advantages of temperature monitoring and thermal calibration of the indenter tip are illustrated, which include the possibility of local thermal conductivity measurement. Finally, validation results using nanoindentation on fused silica and micro-compression of <100> silicon micro-pillars as a function of temperature up to 500 Degree-Sign C are presented, and procedures and considerations taken for these measurements are discussed. A brittle to ductile transition from fracture to splitting then plastic deformation is directly observed in the SEM for silicon as a function of temperature.

36 MATERIALS SCIENCE↗

Observation of two-dimensional p-type dopant diffusion across a p{sup +}-InP/n{sup -}-InGaAs interface using scanning electron microscopy

Scanning electron microscopy (SEM) with potential calculations has been shown to be effective for the detection of p-type dopant diffusion, even across a Zn doped p{sup +}-InP/non-doped n{sup -}-InGaAs/n{sup +}-InP heterojunction. Heterojunction samples were observed using SEM and the electrostatic potential was calculated from Zn concentration profiles obtained by secondary ion mass spectrometry. The sensitivity of SEM for the potential was derived from the SEM observations and potential calculation results. The results were then used to investigate the dependence of the SEM contrast on the Zn diffusion length across the p{sup +}-InP/non-doped n{sup -}-InGaAs interface. Accurate dopant mapping was difficult when the Zn diffusion length was shorter than 30 nm, because the heterojunction affects the potential at the interface. However, accurate dopant mapping was possible when the Zn diffusion length was longer than 30 nm, because the factor dominating the potential variation was not the heterojunction, but rather Zn diffusion 30 nm distant from the interface. Thus, Zn diffusion further than 30 nm from a Zn-doped p{sup +}-InP/non-doped n{sup -}-InGaAs interface can be effectively detected by secondary electron (SE) imaging. SE imaging with potential calculations can be widely used for accurate dopant mapping, even at heterojunctions, and is, therefore, expected to be of significant assistance to the compound semiconductor industry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron channeling contrast imaging studies of nonpolar nitrides using a scanning electron microscope

Threading dislocations, stacking faults, and associated partial dislocations significantly degrade the optical and electrical properties of materials such as non-polar III-nitride semiconductor thin films. Stacking faults are generally difficult to detect and quantify with existing characterization techniques. We demonstrate the use of electron channeling contrast imaging in the scanning electron microscope to non-destructively reveal basal plane stacking faults terminated by partial dislocations in m-plane GaN and InGaN/GaN multiple quantum well structures grown on {gamma}-LiAlO{sub 2} by metal organic vapor phase epitaxy.

36 MATERIALS SCIENCE↗

An easy-to-implement filter for separating photo-excited signals from topography in scanning tunneling microscopy

In order to achieve elemental and chemical sensitivity in scanning tunneling microscopy (STM), synchrotron x-rays have been applied to excite core-level electrons during tunneling. The x-ray photo-excitations result in tip currents that are superimposed onto conventional tunneling currents. While carrying important physical information, the varying x-ray induced currents can destabilize the feedback loop causing it to be unable to maintain a constant tunneling current, sometimes even causing the tip to retract fully or crash. In this paper, we report on an easy-to-implement filter circuit that can separate the x-ray induced currents from conventional tunneling currents, thereby allowing simultaneous measurements of topography and chemical contrasts. The filter and the schematic presented here can also be applied to other variants of light-assisted STM such as laser STM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra low-K shrinkage behavior when under electron beam in a scanning electron microscope

In this paper, we investigate the tendency of porous low-K dielectrics (also named Ultra Low-K, ULK) behavior to shrink when exposed to the electron beam of a scanning electron microscope. Various experimental electron beam conditions have been used for irradiating ULK thin films, and the resulting shrinkage has been measured through use of an atomic force microscope tool. We report the shrinkage to be a fast, cumulative, and dose dependent effect. Correlation of the shrinkage with incident electron beam energy loss has also been evidenced. The chemical modification of the ULK films within the interaction volume has been demonstrated, with a densification of the layer and a loss of carbon and hydrogen elements being observed.

36 MATERIALS SCIENCE↗

Reliable strain measurement in transistor arrays by robust scanning transmission electron microscopy

Accurate measurement of the strain field in the channels of transistor arrays is critical for strain engineering in modern electronic devices. We applied atomic-resolution high-angle annular dark-field scanning transmission electron microscopy to quantitative measurement of the strain field in transistor arrays. The quantitative strain profile over 20 transistors was obtained with high reliability and a precision of 0.1%. The strain field was found to form homogeneously in the channels of the transistor arrays. Furthermore, strain relaxation due to the thin foil effect was quantitatively investigated for thicknesses of 35 to 275 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning tunneling microscopy study of the superconducting properties of three-atomic-layer Pb films

Ultrathin Pb films with a thickness of three monolayers (ML) were prepared on α-√(3)×√(3)Pb/Si(111) (Pb-SIC) substrate by molecular beam epitaxy. Despite significant defect scattering, low temperature scanning tunneling microscopy reveals a high superconducting transition temperature T{sub c} of 6.9 K, compared with the bulk T{sub c} (7.2 K). By applying external magnetic field, magnetic vortices were directly imaged, which demonstrates the robustness of superconductivity. By comparing to nearly free-standing Pb films on graphitized SiC (0001) substrate, we suggest that the higher T{sub c} of 3 ML Pb films on Pb-SIC originates from the combined effects of quantum confinement and substrate-enhanced electron-phonon coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-temperature scanning tunneling microscopy and transport measurements on adsorbate-induced two-dimensional electron systems

We have performed not only magnetotransport measurements on two-dimensional electron systems (2DESs) formed at the cleaved surfaces of p-InAs but also observations of the surface morphology of the adsorbate atoms, which induced the 2DES at the surfaces of narrow band-gap semiconductors, with use of a scanning tunneling microscopy. The electron density of the 2DESs is compared to the atomic density of the isolated Ag adatoms on InAs surfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Epitaxial growth of CeO{sub 2}(111) film on Ru(0001): Scanning tunneling microscopy (STM) and x-ray photoemission spectroscopy (XPS) study

We formed an epitaxial film of CeO{sub 2}(111) by sublimating Ce atoms on Ru(0001) surface kept at elevated temperature in an oxygen ambient. X-ray photoemission spectroscopy measurement revealed a decrease of Ce{sup 4+}/Ce{sup 3+} ratio in a small temperature window of the growth temperature between 1070 and 1096 K, which corresponds to the reduction of the CeO{sub 2}(111). Scanning tunneling microscope image showed that a film with a wide terrace and a sharp step edge was obtained when the film was grown at the temperatures close to the reduction temperature, and the terrace width observed on the sample grown at 1060 K was more than twice of that grown at 1040 K. On the surface grown above the reduction temperature, the surface with a wide terrace and a sharp step was confirmed, but small dots were also seen in the terrace part, which are considerably Ce atoms adsorbed at the oxygen vacancies on the reduced surface. This experiment demonstrated that it is required to use the substrate temperature close to the reduction temperature to obtain CeO{sub 2}(111) with wide terrace width and sharp step edges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗